1.
BMC Musculoskelet Disord ; 24(1): 51, 2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36670400

RESUMO

BACKGROUND: The majority of knee endoprostheses are cemented. In an earlier study the effects of different cementing techniques on cement penetration were evaluated using a Sawbone model. In this study we used a human cadaver model to study the effect of different cementing techniques on relative motion between the implant and the femoral shaft component under dynamic loading. METHODS: Two different cementing techniques were tested in a group of 15 pairs of human fresh frozen legs. In one group a conventional cementation technique was used and, in another group, cementation was done using a pressurizing technique. Under dynamic loading that simulated real life conditions relative motion at the bone-implant interface were studied at 20 degrees and 50 degrees flexion. RESULTS: In both scenarios, the relative motion anterior was significantly increased by pressure application. Distally, it was the same with higher loads. No significant difference could be measured posteriorly at 20°. At 50° flexion, however, pressurization reduced the posterior relative motion significantly at each load level. CONCLUSION: The use of the pressurizer does not improve the overall fixation compared to an adequate manual cement application. The change depends on the loading, flexion angle and varies in its proportion in between the interface zones.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Cimentos Ósseos , Próteses e Implantes
2.
Medicina (Kaunas) ; 57(11)2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34833405

RESUMO

Background and Objectives: Femoral head and liner exchange is an established treatment for polyethylene wear but has had a more limited role in the treatment of other conditions including dislocation, because of concerns about an increased postoperative dislocation rate. Some authors have considered dislocation associated with polyethylene wear to be a contraindication for this procedure. Materials and Methods: Our retrospective review evaluated the outcome of head and liner exchange in a small consecutively operated heterogeneous cohort of 20 patients who presented with dislocation unrelated to trauma, component malposition or component loosening. Of this group, 12 had prior primary total hip arthroplasty, and 8 had prior revision total hip arthroplasty, and included 4 patients with prior revision for dislocation. Mean follow-up was 6 ± 3.5 years (range 1-145 months). Results: Kaplan-Meier analysis revealed a revision-free implant survival from any cause of 80% (confidence interval 95%:64.3-99.6%) at 5 years after head and liner exchange (index surgery). At final follow-up, 83.3% of patients (n = 10) with prior primary total hip arthroplasty and 62.5% of patients (n = 5) with prior revision total hip arthroplasty, had not required subsequent revision for any cause. None (0%) of the primary total hip arthroplasty group and 3 (38%) of the revision arthroplasty group had required revision for further dislocation. Of the eight revision arthroplasty patients, four had a prior revision for dislocation and three of these four patients required further revision for dislocation after index surgery. The fourth patient had no dislocation after index surgery. One additional patient who had prior revision surgery for femoral component fracture suffered dislocation after index surgery, but was successfully treated with closed reduction. Conclusions: In our study population, femoral head and liner exchange was an effective treatment option for patients with prior primary total hip arthroplasty and also for a highly select group of revision total arthroplasty patients with no prior history of dislocation. Femoral head and liner exchange does not appear to be a viable treatment option for patients who have had revision total arthroplasty after prior dislocations.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco
3.
J Arthroplasty ; 33(6): 1838-1843, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29510951

RESUMO

BACKGROUND: Revision total hip arthroplasty frequently faces challenges associated with deficient bone stock. Porous metal implants were developed to meet the challenge, but require rapid osseointegration for ultimate success. This study aims to assess relative motion as an indicator for primary stability and osseointegration of two different titanium cups each combined with a titanium augment. METHODS: In 14 cadaver hemipelvises, 2 types of titanium acetabular cups, a traditional sintered-bead cup (POROCOAT Acetabular Cup [PAC]) and a newer porous-coated cup (GRIPTION Acetabular Cup [GAC]) each associated with a porous augment, were subjected to 3-dimensional varying loads, replicating 30% of loads experienced during normal gait. Relative motion was measured at the cup/bone, augment/bone, and cup/augment interfaces. RESULTS: Only at the cup/bone interface was there a statistically significant difference in relative motion between the traditional PAC and the newer GAC, with PAC showing less relative motion (P = .0037). Bone mineral density (BMD) had a significant effect on relative motion (P = .0019) at the cup/bone interface of both cup types, with low BMD specimens showing more relative motion. CONCLUSION: Both cup types combined with augments displayed minimal relative motion that was within the accepted range thought to allow osseointegration, although the traditional surface proved superior to the newer surface. This difference was more pronounced at low BMD, with the well-established PAC cup displaying less relative motion than the more porous GAC cup, consistent with better osseointegration than the more porous cup. This suggests that the more porous implant may be less advantageous than traditional PAC cups, particularly in cases with poorer bone stock.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Osseointegração , Desenho de Prótese , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Humanos , Metais , Pessoa de Meia-Idade , Porosidade , Reoperação , Titânio
4.
J Arthroplasty ; 33(11): 3524-3530, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30060906

RESUMO

BACKGROUND: Our study examines the long-term results of acetabular reconstruction using the Ganz acetabular reinforcement ring (GRR) in total hip arthroplasty. METHODS: Between 1998 and 2001, 135 hips (119 revision and 16 primary arthroplasties) were consecutively implanted with a GRR at our hospital. The average age was 65 years (range, 26-90). Clinical and radiographic evaluations were carried out. Long-term survivorship was estimated using a competing risks analysis, and multivariate survivorship using Cox regression model was used to identify risk factors for implant failure. RESULTS: At a mean follow-up of 16 years (range, 15-18), 3 patients were lost to follow-up and 19 had implant failure: 4 aseptic loosenings without re-revision, 4 septic, and 11 aseptic re-revisions. Survival was estimated at 86% after 16 years (95% confidence interval [CI], 78.5%-90.9%) using radiographic loosening or revision for any reason as the end point. Using aseptic loosening as the end point, the survival was estimated at 91.2% after 16 years (95% CI, 84.5%-95.0%). Multivariate analysis revealed that age at surgery was a significant risk factor for failure of the GRR. With acetabular revision or loosening as the end point, patients ≤60 years had 71.6% (95% CI, 53%-82.8%) and older patients had 92.2% (95% CI, 84%-96.2%) probability of implant survival after a mean 16-year follow-up. The median Harris Hip Scores and Western Ontario and McMaster Universities Osteoarthritis Index scores were 77 and 64.5, respectively, and mean Numerical Pain Rating Scale score was 1.6 at final follow-up. CONCLUSION: Our long-term study showed acceptable survival and functional results using the GRR in older patients, while young patients had less favorable survival.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Reoperação/estatística & dados numéricos , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Fatores de Risco
5.
J Arthroplasty ; 33(2): 580-585, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29108792

RESUMO

BACKGROUND: The number of revision hip arthroplasty procedures has been increasing substantially, with the acetabular component requiring component revision in over half of the cases. New porous implant designs attempt to improve outcomes due to improved osseointegration; however, sufficient primary stability is paramount for good osseointegration. METHODS: We compared 2 revision cups of the same geometry, yet different surface properties in an in vitro scenario: a porous titanium surface and a conventional sintered-bead titanium surface. These were tested in 10 cadaveric pelvises under a physiologic cyclic partial weight-bearing scenario. Each side was randomly implanted with one of the implants. Relative motion between the bone and cup was measured using an optical measuring device. Statistical evaluation was carried out descriptively using a covariance analysis with repeated measures and a test of fixed effects, with significance determined as P < .05. RESULTS: The conventional cup displayed an average relative motion of 28.02 µm; and the porous implant displayed an average relative motion of 33.42 µm. There was no statistically significant difference between the two with regard to the resultant relative motion (P = .2649). The bone mineral density does have a significant influence on resultant relative motion (P = .0406), with higher bone mineral density correlating with less relative motion in both implants. CONCLUSION: The porous implant provides similar primary stability to the conventional implant in the tested scenario; the motion of both implants relative to the bone was within safe limits for osseointegration. Bone stock must be considered when choosing implant type and postoperative care.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Instabilidade Articular/cirurgia , Osseointegração , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Densidade Óssea , Cadáver , Prótese de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Porosidade , Falha de Prótese , Reoperação
6.
Orthopade ; 47(4): 288-295, 2018 04.
Artigo em Alemão | MEDLINE | ID: mdl-29556679

RESUMO

BASICS: Postoperative surgical site infections of the spine have been described in up to 20% of patients and can result in serious consequences for the patient and substantial treatment costs. Typical bacteria often arise from skin or fecal flora. Various risk factors for infection have been described, including obesity, diabetes, high ASA scores, as well as intraoperative factors such as heavy blood loss, dural tears, or several revision procedures. Consequently, the prophylaxis with pre- and postoperative risk minimization is of particular importance. TREATMENT: When an infection has developed, it is important to carry out early operative revision involving tissue debridement, lavage and acquiring microbiological samples for culture. If the infection presents early, the instrumentation can often be retained. Adjuvant measures such as negative pressure wound treatment may improve the outcome. In late-onset infections, due to the biofilm production on the instrument surface or in cases of implant loosening, one should attempt to remove the instrumentation, and in cases of instability replace it. This article deals with the current literature on the subject and provides an overview of the data with regard to peri- and postoperative infections.


Assuntos
Procedimentos de Cirurgia Plástica , Coluna Vertebral , Infecção da Ferida Cirúrgica , Desbridamento , Humanos , Estudos Retrospectivos , Fatores de Risco , Coluna Vertebral/cirurgia , Infecção da Ferida Cirúrgica/tratamento farmacológico , Infecção da Ferida Cirúrgica/prevenção & controle , Irrigação Terapêutica
7.
Arch Orthop Trauma Surg ; 136(8): 1099-106, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27236584

RESUMO

INTRODUCTION: Geriatric hip fracture patients are a highly heterogeneous collective, what distinctly aggravates the best possible treatment. Consequently, it is becoming more important to identify selection criteria that can distinguish those patients who can benefit the most from treatment in a geriatric fracture center. In our pilot study, we assessed the 2007 published Penrod score for its utility as a useful selection tool by prospectively comparing our own patient's outcome with the Penrod study. METHODS: 77 patients treated for geriatric hip fracture were preoperatively classified according to the Penrod score. Patients were divided into three clusters by age (1: <75 years, 2: 75-84 years, 3: ≥85 years). Clusters 2 and 3 were then classified according to their ability to perform activities of daily living (ADL's) and cognitive status (presence or absence of dementia). In 51 out of these 77 patients, the ability to perform ADLs could be assessed 6 months postoperatively and was compared with the Penrod scores. RESULTS: 58 % of cluster 1 patients were able to perform 4 ADLs independently 6 months postoperatively (52.9 % Penrod study). In clusters 2A and 3A, 48 and 50 %, respectively, were able to perform 4 ADLs independently, compared with 40.6 and 31.5 % (Penrod collective). 22 % of our patients in 2B performed all ADLs independently (3.6 % Penrod) and 25 % in cluster 3B (9.4 % Penrod). CONCLUSION: Our preliminary results support the prognostic value of the Penrod score in the treatment of geriatric hip fracture patients. With the help of the Penrod score, it may be possible to identify patients, who are expected to significantly profit from an intensified treatment in a geriatric fracture center (clusters 2B, 3A, and 3B). By utilizing this score, improved outcomes and simultaneously a more effective utilization of valuable health care resources could be achieved.


Assuntos
Tomada de Decisão Clínica , Avaliação da Deficiência , Avaliação Geriátrica , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Feminino , Fixação Interna de Fraturas , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Suíça
8.
BMC Musculoskelet Disord ; 16: 249, 2015 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-26363981

RESUMO

BACKGROUND: The optimal type of bearing for hip arthroplasty remains a matter of debate. Ceramic-on-polyethylene (CoP) bearings are frequently used in younger and more active patients to reduce wear and increase biocompatibility compared to Metal-on-Polyethylene (MoP) bearings. However, in comparison to metal heads, the fracture risk of ceramic heads is higher. In addition, ceramic head fractures pose a serious complication which often necessitates major revision surgery. To date, there are no long-term data (>20 years of follow-up) reporting fracture rates of the ceramic femoral heads in CoP bearings. The purpose of this research was to investigate long-term CoP fracture rate. METHODS: We evaluated the clinical and radiographic results of 348 cementless THAs treated with 2nd generation Biolox Al2O3 Ceramic-on-Polyethylene (CoP) bearings consecutively implanted between January 1985 and December 1989. The mean age at implantation was 57 years. The patients were followed for a minimum of 20 years. At the final 111 had died, and 5 were lost to follow-up. The cumulative incidence of ceramic head fractures in the long-term was estimated using a competing risk analysis. RESULTS: The cumulative incidence of ceramic head fracture after 22-years was estimated with a competing risk analysis at 0.29% after 22-years (SE = 2.09%; 95% - CI: 0.03-1.5%). The radiographic analysis revealed no impending failures at final follow-up. DISCUSSION/CONCLUSION: The fracture rate of second-generation ceramic heads using a CoP articulation remains very low into the third decade after cementless THA.


Assuntos
Óxido de Alumínio/administração & dosagem , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/tendências , Prótese de Quadril/tendências , Desenho de Prótese/tendências , Falha de Prótese/tendências , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Prótese de Quadril/normas , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/normas , Fatores de Tempo , Adulto Jovem
9.
Knee Surg Sports Traumatol Arthrosc ; 23(8): 2151-2158, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24696004

RESUMO

PURPOSE: Detailed biomechanical analysis including isokinetic muscle strength measurements after autologous chondrocyte implantation (ACI) are still rare, but might be of crucial importance for long-term outcomes. The present prospective study was performed to evaluate whether defect location had any influence on clinical and biomechanical outcomes 4 years after ACI. METHODS: Forty-four patients with full-thickness cartilage defects ICRS grade III B and C underwent ACI and were assigned to two groups, the femoral condyle group or the patellofemoral joint group. Clinical scores were gathered preoperatively and 6, 12 and 48 months after implantation using the International Knee Documentation Committee (IKDC) score and the International Cartilage Repair Society (ICRS) form. Isokinetic strength measurements were performed 48 months postoperatively comparing healthy and operated knee joint of each patient. RESULTS: Clinical scores (ICRS, IKDC) showed continuous significant (p < 0.05) improvement over the study period for both groups. Isokinetic muscle strength measurements showed significantly reduced maximum strength capacities for the operated knee joint compared to the healthy knee in both groups (p < 0.05). Hamstring-quadriceps ratios of the operated extremity revealed a significant change in physiological muscle balancing (ratios >1.0) based on significantly impaired extensor muscle strength in the patellofemoral joint group. CONCLUSION: All patients showed significant strength deficits on the operated extremity 4 years after ACI. Furthermore, the patellofemoral compartment in particular showed significantly worse hamstring-quadriceps ratios compared to condylar defects. Consequently, more efforts should be made to restore muscular strength especially of the quadriceps and the rehabilitation protocol should be adjusted accordingly. LEVEL OF EVIDENCE: II.


Assuntos
Cartilagem Articular/lesões , Cartilagem Articular/cirurgia , Condrócitos/transplante , Fêmur/cirurgia , Força Muscular , Articulação Patelofemoral/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Transplante Autólogo , Adulto Jovem
10.
J Arthroplasty ; 30(2): 249-53, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25445853

RESUMO

Aseptic loosening and focal osteolysis are the most common reasons for knee arthroplasty failure. The best treatment remains unclear. We reviewed the literature on the treatment of revision knee arthroplasty using bony structural allografts (476 cases) and porous metal cones (223 cases) to determine if a difference in the revision failure rates was discernable. The failure rates were compared using a logistic regression model with adjustment for discrepancies in FU time and number of grafts used (femoral, tibial, or both). In this analysis, the porous implant shows a significantly decreased loosening rate in AORI 2 and 3 defects. The overall failure rate was also substantially lower in the porous metal group than the structural allograft group; little difference in the infection rates was noted.


Assuntos
Artroplastia do Joelho , Osteólise/cirurgia , Materiais Biocompatíveis , Transplante Ósseo , Humanos , Prótese do Joelho , Metais , Desenho de Prótese , Falha de Prótese , Reoperação , Transplante Homólogo
11.
J Arthroplasty ; 29(1): 229-35, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23719095

RESUMO

The best method of revision acetabular arthroplasty remains unclear. Consequently, we reviewed the literature on the treatment of revision acetabular arthroplasty using revision rings (1541 cases; mean follow-up (FU) 5.7 years) and Trabecular Metal, or TM, implants (1959 cases; mean FU 3.7 years) to determine if a difference with regard to revision failure could be determined. Failure rates of the respective implants were compared statistically using a logistic regression model with adjustment for discrepancies in FU time. In our study, TM shows statistically significant decreased loosening rates relative to revision rings for all grades including severe acetabular defects and pelvic discontinuity. The severe defects appear to benefit the most from TM.


Assuntos
Acetábulo/cirurgia , Prótese de Quadril , Falha de Prótese , Idoso , Artroplastia de Quadril , Humanos , Pessoa de Meia-Idade , Reoperação
12.
Int Orthop ; 38(11): 2237-43, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24968787

RESUMO

PURPOSE: Neurogenic hip dislocation is frequently observed in patients with cerebral palsy (CP). If the hip is not centred but not dislocated, the hip joint can be recentered with minor operative effort. Reconstructive procedures are indicated if the femoral head is subluxated or dislocated. There are no data as to when destruction of the femoral head requires a salvage procedure or whether hip reconstruction surgery is successful in restoring joint congruity in patients with CP. Our aim was to investigate femoral head plasticity after hip reconstruction surgery in a long-term outcome study. METHODS: We studied a large cohort of patients with CP and high hip dislocation (Tönnis grade IV) before surgery. Sixty-eight patients were assessed, of whom 23 presented with bilateral high hip dislocation, and 91 complex hip reconstructions were conducted. Standardised radiographic examination was performed before and directly after surgery and at the long-term follow-up examination. RESULTS: Pain was the most frequent reason for complex hip-joint reconstruction (49 patients, 72%). An impressive improvement in pain was demonstrated postoperatively. Forty-five hip joints presented aspheric incongruity postoperatively, which improved on average 7.7 years after surgery and 59 hip joints showed congruency. Only 15% of patients experienced pain at the time of final follow-up, and that was of low intensity. CONCLUSIONS: Early conservative treatment for hip dislocation is helpful, and operative reconstruction should also be scheduled early. Continued surveillance is necessary, and Reimers index is useful for monitoring the development of hip centering. In case of hip pain and femoral head deformity, our long-term study indicates that hip reconstruction surgery as a part of multilevel surgery improves pain and function in patients with CP and Tönnis IV hip dislocation, even if the hip joint is incongruent after operation. This incongruity improves over the long-term. If possible, a reconstruction procedure should be performed before the femoral head becomes deformed. High plasticity of the hip joint suggest that even if the femoral head is deformed, hip reconstruction can be recommended.


Assuntos
Paralisia Cerebral/cirurgia , Luxação do Quadril/cirurgia , Articulação do Quadril/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Cabeça do Fêmur/cirurgia , Humanos , Estudos Longitudinais , Masculino , Osteotomia/métodos , Resultado do Tratamento , Adulto Jovem
13.
Acta Orthop ; 85(5): 531-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24798109

RESUMO

BACKGROUND: Revision arthroplasty often requires anchoring of prostheses to poor-quality or deficient bone stock. Recently, newer porous materials have been introduced onto the market as additional, and perhaps better, treatment options for revision arthroplasty. To date, there is no information on how these porous metals interface with bone cement. This is of clinical importance, since these components may require cementing to other prosthesis components and occasionally to bone. METHODS: We created porous metal and bone cylinders of the same size and geometry and cemented them in a well-established standardized setting. These were then placed under tensile loading and torsional loading until failure was achieved. This permitted comparison of the porous metal/cement interface (group A) with the well-studied bone/cement interface (group B). RESULTS: The group A interface was statistically significantly stronger than the group B interface, despite having significantly reduced depth of cement penetration: it showed a larger maximum tensile force (effect size 2.7), superior maximum tensile strength (effect size 2.6), greater maximum torsional force (effect size 2.2), and higher rotational stiffness (effect size 1.5). INTERPRETATION: The newer porous implants showed good interface properties when cemented using medium-viscosity bone cement. The axial and rotational mechanical strength of a porous metal/cement interface appeared to be greater than the strength of the standard bone/cement interface. These results indicate that cementing of porous implants can provide great stability in situations where it is needed.


Assuntos
Cimentos Ósseos/uso terapêutico , Cimentação/métodos , Prótese Articular , Humanos , Prótese Articular/normas , Próteses Articulares Metal-Metal/normas , Falha de Prótese , Estresse Mecânico , Resistência à Tração , Torção Mecânica , Suporte de Carga
14.
J Clin Med ; 11(9)2022 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-35566682

RESUMO

A variety of gait pathologies is seen in cerebral palsy. Movement patterns between different levels of functional impairment may differ. The objective of this work was the evaluation of Gross Motor Function Classification System (GMFCS) level-specific movement disorders. A total of 89 individuals with unilateral cerebral palsy and no history of prior treatment were included and classified according to their functional impairment. GMFCS level-specific differences, kinematics and joint moments, exclusively of the involved side, were analyzed for all planes for all lower limb joints, including pelvic and trunk movements. GMFCS level I and level II individuals most relevantly showed equinus/reduced dorsiflexion moments, knee flexion/reduced knee extension moments, reduced hip extension moments with pronounced flexion, internal hip rotation and reduced hip abduction. Anterior pelvic tilt, obliquity and retraction were found. Individuals with GMFCS level II were characterized by an additional pronounced reduction in all extensor moments, pronounced rotational malalignment and reduced hip abduction. The most striking characteristics of GMFCS level II were excessive anterior pelvic/trunk tilt and excessive trunk obliquity. Pronounced reduction in extensor moments and excessive trunk lean are distinguishing features of GMFCS level II. These patients would benefit particularly from surgical treatment restoring pelvic symmetry and improving hip abductor leverage. Future studies exploring GMFCS level-specific compensation of the sound limb and GMFCS level-specific malalignment are of interest.

15.
J Clin Med ; 11(16)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36013051

RESUMO

Classification of gait disorders in cerebral palsy (CP) remains challenging. The Winters, Gage, and Hicks (WGH) is a commonly used classification system for unilateral CP regarding the gait patterns (lower limb kinematics) solely in the sagittal plane. Due to the high number of unclassified patients, this classification system might fail to depict all gait disorders accurately. As the information on trunk/pelvic movements, frontal and transverse planes, and kinetics are disregarded in WGH, 3D instrumented gait analysis (IGA) for further characterization is necessary. The objective of this study was a detailed analysis of patients with unilateral CP using IGA taking all planes/degrees of freedom into account including pelvic and trunk movements. A total of 89 individuals with unilateral CP matched the inclusion criteria and were classified by WGH. Subtype-specific differences were analyzed. The most remarkable findings, in addition to the established WGH subtype-specific deviations, were pelvic obliquity and pelvic retraction in all WGH types. Furthermore, the unclassified individuals showed altered hip rotation moments and pelvic retraction almost throughout the whole gait cycle. Transversal malalignment and proximal involvement are relevant in all individuals with unilateral CP. Further studies should focus on WGH type-specific rotational malalignment assessment (static vs. dynamic, femoral vs. tibial) including therapeutic effects and potential subtype-specific compensation mechanisms and/or tertiary deviations of the sound limb.

16.
J Clin Med ; 10(15)2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-34362030

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) can be devastating for the patient and demanding for the surgeon. In acute PJI, attempts are made to retain the prosthesis by debridement of the infected tissue, targeted antibiotic therapy and an exchange of modular components with implant retention (DAIR). There has been sparse research with adjunctive negative pressure wound treatment with wound irrigation (NPWTI) on the treatment outcome. QUESTIONS/PURPOSES: The goal was to assess the efficacy of our protocol of DAIR with adjunctive NPWTI in acute PJI and to reduce the need for later additional DAIR and Irrigation and Debridement (I and D). PATIENTS AND METHODS: Our cohort of 30 patients (31 hips) with acute PJI was divided into two groups based on symptom presentation up to 6 weeks or >6 weeks from prior (index) surgery (acute early or acute late groups, respectively). All received DAIR with an exchange of modular components and NPWTI with polyhexanide instillation, with the goal of bacterial elimination and biofilm elimination. Postoperatively, the patients were followed up clinically and radiographically for a mean of 4.3 years. RESULTS: Of the 31 PJI hips, 19 were early acute and 12 were late acute. In total, 21 hips had no evidence of residual infection, 10 required further surgical revision: 1 due to dislocation and 9 due to infection. Of these nine, seven had a removal of all the components and two were treated with irrigation and debridement (I and D), with the demise of one patient from pneumonia shortly after the procedure. The Kaplan-Meier 60-month revision free implant survival from infection was 73.2% (CI: 58.9-91.0%) and at the final follow up, the mean Harris Hip Score (HHS) was 81.1 ± 11.8 and the mean WOMAC score was 33.3 ± 20.1. CONCLUSIONS: Our results are in line with those reported in prior studies. However, the utility of our protocol is inconclusive and needs further evaluation based on our small cohort and the lack of a control group. LEVEL OF EVIDENCE: IV.

17.
J Clin Med ; 10(17)2021 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-34501450

RESUMO

The goal of this study is to evaluate the primary stability of a cementless augment-and-modular-cage system with and without the addition of cranial straps in a standardized in vitro setting. As the surrogate parameter for the evaluation of primary stability, the measurement of relative motion between the implant components themselves and the bone will be used. Acetabular revision components with a trabecular titanium augment in combination with a large fourth-generation composite left hemipelvis were assembled. These constructs were divided into two groups with (S) and without cranial straps (nS). A total of 1000 cycles was applied at each of three load levels. Relative movements (RM) between the components were measured. Load levels display a significant effect on the amount of RM at all interfaces except between shell/augment. The group assignment appears to have an effect on RM due to significantly differing means at all interfaces. Between bone/shell RM increased as load increased. NS displayed significantly more RM than S. Between shell/augment RM remained constant as load increased. Between shell/cup S showed more RM than nS while both groups' RM increased with load. We conclude a significant increase of primary stability between the shell and the bone through the addition of cranial straps. Relative motion between components (shell/cup) increases through the addition of cranial straps. A clinical impact of this finding is uncertain and requires further investigation. Finally, the cementless fixation of the augment against the rim-portion of the shell appears stable and compares favorably to prior investigation of different fixation techniques.

18.
Laryngoscope ; 131(7): 1474-1481, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33141438

RESUMO

OBJECTIVES/HYPOTHESIS: This study is a systematic review of the literature which seeks to estimate the expected treatment outcomes of a patient with Sjogren's syndrome (SS) undergoing therapeutic sialendoscopy. STUDY DESIGN: Systematic Review. METHODS: PubMed, Scopus, and Cochrane library databases were used to search for studies published as of August 2020 regarding the treatment outcomes of SS with sialendoscopy. The key search terms included "Sjogren's syndrome" and "sialendoscopy." Only studies in the English language involving more than one human patient were included. PRISMA guidelines were followed in study inclusion and data extraction. The primary outcome assessed was improvement in patient symptoms. RESULTS: Six studies met criteria and were analyzed in this review, including 125 patients undergoing sialendoscopy of parotid and/or submandibular glands as well as 25 controls. Of these patients, 90% were female with an age range of 18 to 79 years. There was significant diversity in outcome reporting tools. The outcomes of symptom improvement were pooled qualitatively based on improvement noted in each study. Outcomes were defined as partial improvement if the measured outcomes improved and complete improvement if measured outcomes resolved entirely. Despite the limited number of studies on this topic, this meta-analysis suggests that a similar study of therapeutic sialendoscopy could expect to provide at least temporary improvement of symptoms 90% to 99% of the time. CONCLUSIONS: This review provides support for the application of sialendoscopy in the treatment of SS salivary disease. Larger studies with consistent outcome reporting tools and control groups are needed to validate these results and provide a consistent therapy protocol. Laryngoscope, 131:1474-1481, 2021.


Assuntos
Endoscopia/métodos , Glândulas Salivares/cirurgia , Sialadenite/cirurgia , Síndrome de Sjogren/cirurgia , Estudos de Casos e Controles , Humanos , Glândulas Salivares/imunologia , Índice de Gravidade de Doença , Sialadenite/diagnóstico , Sialadenite/imunologia , Síndrome de Sjogren/complicações , Síndrome de Sjogren/diagnóstico , Síndrome de Sjogren/imunologia , Resultado do Tratamento
20.
Materials (Basel) ; 13(6)2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-32204382

RESUMO

The resulting inflammatory reaction to polyethylene (PE) wear debris, which may result in osteolysis, is still considered to be a main reason for aseptic loosening. In addition to the primary wear in hip joint replacements caused by head-insert articulation, relative motions between the PE liner and the metal cup may cause additional wear. In order to limit this motion, various locking mechanisms were used. We investigated three different locking mechanisms (Aesculap, DePuy, and Zimmer Biomet) to address the resulting relative motion between the acetabular cup and PE liner and the maximum disassembly force. A standardized setting with increasing load levels was used in combination with optically based three-dimensional measurements. In addition the maximum disassembly forces were evaluated according to the ASTM F1820-13 standard. Our data showed significant differences between the groups, with a maximum relative motion at the maximum load level (3.5 kN) of 86.5 ± 32.7 µm. The maximum axial disassembly force was 473.8 ± 94.6 N. The in vitro study showed that various locking mechanisms may influence cup-inlay stability.