Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Gut ; 72(10): 1904-1918, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37463757

RESUMO

OBJECTIVE: New screening tests for colorectal cancer (CRC) are rapidly emerging. Conducting trials with mortality reduction as the end point supporting their adoption is challenging. We re-examined the principles underlying evaluation of new non-invasive tests in view of technological developments and identification of new biomarkers. DESIGN: A formal consensus approach involving a multidisciplinary expert panel revised eight previously established principles. RESULTS: Twelve newly stated principles emerged. Effectiveness of a new test can be evaluated by comparison with a proven comparator non-invasive test. The faecal immunochemical test is now considered the appropriate comparator, while colonoscopy remains the diagnostic standard. For a new test to be able to meet differing screening goals and regulatory requirements, flexibility to adjust its positivity threshold is desirable. A rigorous and efficient four-phased approach is proposed, commencing with small studies assessing the test's ability to discriminate between CRC and non-cancer states (phase I), followed by prospective estimation of accuracy across the continuum of neoplastic lesions in neoplasia-enriched populations (phase II). If these show promise, a provisional test positivity threshold is set before evaluation in typical screening populations. Phase III prospective studies determine single round intention-to-screen programme outcomes and confirm the test positivity threshold. Phase IV studies involve evaluation over repeated screening rounds with monitoring for missed lesions. Phases III and IV findings will provide the real-world data required to model test impact on CRC mortality and incidence. CONCLUSION: New non-invasive tests can be efficiently evaluated by a rigorous phased comparative approach, generating data from unbiased populations that inform predictions of their health impact.


Assuntos
Neoplasias Colorretais , Programas de Rastreamento , Humanos , Estudos Prospectivos , Detecção Precoce de Câncer , Neoplasias Colorretais/epidemiologia , Colonoscopia , Sangue Oculto , Fezes
2.
Gut ; 2022 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-35820780

RESUMO

Faecal immunochemical testing (FIT) has a high sensitivity for the detection of colorectal cancer (CRC). In a symptomatic population FIT may identify those patients who require colorectal investigation with the highest priority. FIT offers considerable advantages over the use of symptoms alone, as an objective measure of risk with a vastly superior positive predictive value for CRC, while conversely identifying a truly low risk cohort of patients. The aim of this guideline was to provide a clear strategy for the use of FIT in the diagnostic pathway of people with signs or symptoms of a suspected diagnosis of CRC. The guideline was jointly developed by the Association of Coloproctology of Great Britain and Ireland/British Society of Gastroenterology, specifically by a 21-member multidisciplinary guideline development group (GDG). A systematic review of 13 535 publications was undertaken to develop 23 evidence and expert opinion-based recommendations for the triage of people with symptoms of a suspected CRC diagnosis in primary care. In order to achieve consensus among a broad group of key stakeholders, we completed an extended Delphi of the GDG, and also 61 other individuals across the UK and Ireland, including by members of the public, charities and primary and secondary care. Seventeen research recommendations were also prioritised to inform clinical management.

3.
Br J Cancer ; 127(8): 1525-1533, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35974099

RESUMO

INTRODUCTION: The NHS Bowel Cancer Screening Programme (BCSP) faces endoscopy capacity challenges from the COVID-19 pandemic and plans to lower the screening starting age. This may necessitate modifying the interscreening interval or threshold. METHODS: We analysed data from the English Faecal Immunochemical Testing (FIT) pilot, comprising 27,238 individuals aged 59-75, screened for colorectal cancer (CRC) using FIT. We estimated screening sensitivity to CRC, adenomas, advanced adenomas (AA) and mean sojourn time of each pathology by faecal haemoglobin (f-Hb) thresholds, then predicted the detection of these abnormalities by interscreening interval and f-Hb threshold. RESULTS: Current 2-yearly screening with a f-Hb threshold of 120 µg/g was estimated to generate 16,092 colonoscopies, prevent 186 CRCs, detect 1142 CRCs, 7086 adenomas and 4259 AAs per 100,000 screened over 15 years. A higher threshold at 180 µg/g would reduce required colonoscopies to 11,500, prevent 131 CRCs, detect 1077 CRCs, 4961 adenomas and 3184 AAs. A longer interscreening interval of 3 years would reduce required colonoscopies to 10,283, prevent 126 and detect 909 CRCs, 4796 adenomas and 2986 AAs. CONCLUSION: Increasing the f-Hb threshold was estimated to be more efficient than increasing the interscreening interval regarding overall colonoscopies per screen-benefited cancer. Increasing the interval was more efficient regarding colonoscopies per cancer prevented.


Assuntos
Adenoma , COVID-19 , Neoplasias Colorretais , Adenoma/diagnóstico , Adenoma/epidemiologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Detecção Precoce de Câncer/métodos , Inglaterra , Hemoglobinas/análise , Humanos , Pandemias , Projetos Piloto
4.
BMC Cancer ; 22(1): 1144, 2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36344941

RESUMO

BACKGROUND: Lynch Syndrome (LS) is an inherited cancer predisposition syndrome defined by pathogenic variants in the mismatch repair (MMR) or EPCAM genes. In the United Kingdom, people with LS are advised to undergo biennial colonoscopy from as early as 25 until 75 years of age to mitigate a high lifetime colorectal cancer (CRC) risk, though the consideration of additional surveillance intervention(s) through the application of non-invasive diagnostic devices has yet to be longitudinally observed in LS patients. In this study, we will examine the role of annual faecal immunochemical testing (FIT) alongside biennial colonoscopy for CRC surveillance in people with LS. METHODS/DESIGN: In this single-arm, prospective, non-randomised study, 400 LS patients will be recruited across 11 National Health Service (NHS) Trusts throughout the United Kingdom. Study inclusion requires a LS diagnosis, between 25 and 73 years old, and a routine surveillance colonoscopy scheduled during the recruitment period. Eligible patients will receive a baseline OC-Sensor™ FIT kit ahead of their colonoscopy, and annually for 3 years thereafter. A pre-paid envelope addressed to the central lab will be included within all patient mailings for the return of FIT kits and relevant study documents. A questionnaire assessing attitudes and perception of FIT will also be included at baseline. All study samples received by the central lab will be assayed on an OC-Sensor™ PLEDIA Analyser. Patients with FIT results of ≥6 µg of Haemoglobin per gram of faeces (f-Hb) at Years 1 and/or 3 will be referred for colonoscopy via an urgent colonoscopy triage pathway. 16S rRNA gene V4 amplicon sequencing will be carried out on residual faecal DNA of eligible archived FIT samples to characterise the faecal microbiome. DISCUSSION: FIT may have clinical utility alongside colonoscopic surveillance in people with LS. We have designed a longitudinal study to examine the efficacy of FIT as a non-invasive modality. Potential limitations of this method will be assessed, including false negative or false positive FIT results related to specific morphological features of LS neoplasia or the presence of post-resection anastomotic inflammation. The potential for additional colonoscopies in a subset of participants may also impact on colonoscopic resources and patient acceptability. TRIAL REGISTRATION: Trial Registration: ISRCTN, ISRCTN15740250 . Registered 13 July 2021.


Assuntos
Neoplasias Colorretais Hereditárias sem Polipose , Neoplasias Colorretais , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Neoplasias Colorretais Hereditárias sem Polipose/diagnóstico , Neoplasias Colorretais Hereditárias sem Polipose/genética , Estudos Longitudinais , Estudos Prospectivos , Medicina Estatal , RNA Ribossômico 16S , Sangue Oculto , Colonoscopia , Hemoglobinas/análise , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/genética , Detecção Precoce de Câncer/métodos
5.
Clin Chem Lab Med ; 60(6): 901-906, 2022 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-35285587

RESUMO

OBJECTIVES: The National Institute for Health and Care Excellence recommends faecal calprotectin (f-cal) to help differentiate inflammatory bowel diseases from irritable bowel syndrome. Faecal samples for calprotectin have historically been collected at home by patients into screw-top pots and sent to laboratories where calprotectin is extracted and analysed. Faecal haemoglobin (f-Hb) samples are collected at home into specific collection devices containing stabilising buffer. We evaluated the OC-FCa method for f-cal, developed by Eiken Chemical Co., Ltd. (Japan) that uses the same collection device and analyser as f-Hb. METHODS: OC-FCa was assessed for limit of blank (LOB), limit of detection (LOD), limit of quantification (LOQ), within and between-run imprecision, linearity, prozone, recovery and carryover. A method comparison against the BÜHLMANN fCAL® turbo (BÜHLMANN Laboratories AG, Switzerland) was performed using patient samples and EQA. RESULTS: The LOB was 3 µg calprotectin/g faeces (µg/g), LOD 8 µg/g and LOQ 20 µg/g. Within and between-run imprecision was <5%; linearity was good (R2 > 0.99); prozone was appropriately detected; recovery was 99.6%; no observed carryover. OC-FCa showed a strong positive bias compared with BÜHLMANN fCAL® turbo (Z=-5.3587, p < 0.001). When categorised using our local pathway, which interprets calprotectin concentrations and need for further investigation, Cohen's Kappa demonstrates substantial agreement at <50 µg/g (κ=0.80) and >150 µg/g (κ=0.63) and fair agreement (κ=0.22) in the borderline category 50-150 µg/g. CONCLUSIONS: The OC-FCa method performed well in the evaluation. With the lack of standardisation for f-cal a clinical study is required to evaluate the positive bias and establish suitable cut-off levels.


Assuntos
Doenças Inflamatórias Intestinais , Complexo Antígeno L1 Leucocitário , Biomarcadores/análise , Fezes/química , Hemoglobinas/análise , Humanos , Doenças Inflamatórias Intestinais/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Limite de Detecção
6.
Clin Chem Lab Med ; 60(8): 1278-1286, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35637625

RESUMO

OBJECTIVES: Faecal immunochemical tests for haemoglobin (FIT) are used in colorectal cancer (CRC) screening programmes and to triage patients presenting with symptoms suggestive of CRC for further bowel investigations. There are a number of quantitative FIT analytical systems available. Currently, there is no harmonisation or standardisation of FIT methods. The aim of the study was to assess the comparability of numerical faecal haemoglobin concentrations (f-Hb) obtained with four quantitative FIT systems and the diagnostic accuracy at different f-Hb thresholds. METHODS: A subgroup of the National Institute for Health and Care Excellence (NICE) FIT study, a multicentre, prospective diagnostic accuracy study were sent four FIT specimen collection devices from four different FIT systems or two FIT devices for one FIT system. Faecal samples were examined and analysis of results carried out to assess difference between methods at thresholds of limit of detection (LoD), 10 µg haemoglobin/g faeces (µg/g) and 100 µg/g. RESULTS: 233 patients returned specimen collection devices for examination on four different systems; 189 patients returned two FIT kits for one system. At a threshold of 100 µg/g the sensitivity is the same for all methods. At lower thresholds of LoD and 10 µg/g differences were observed between systems in terms of patients who would be referred and diagnostic accuracies. CONCLUSIONS: The lack of standardisation or harmonisation of FIT means that differences are observed in f-Hb generated on different systems. Further work is required to understand the clinical impact of these differences and to minimise them.


Assuntos
Neoplasias Colorretais , Enteropatias , Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Fezes/química , Hemoglobinas/análise , Humanos , Sangue Oculto , Estudos Prospectivos , Sensibilidade e Especificidade
7.
Clin Chem Lab Med ; 60(1): 101-108, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-34679264

RESUMO

OBJECTIVES: Faecal immunochemical testing for haemoglobin (FIT) is used to triage patients for colonic investigations. Point-of-care (POC) FIT devices on the market have limited data for their diagnostic accuracy for colorectal cancer (CRC). Here, a POC FIT device is compared with a laboratory-based FIT system using patient collected samples from the urgent referral pathway for suspected CRC. METHODS: A prospective, observational cohort study. Patients collected two samples from the same stool. These were measured by POC QuikRead go® (Aidian Oy, Espoo, Finland) and laboratory-based FOB Gold Wide® (Sentinel Diagnostics, Italy). Faecal haemoglobin <10 µg haemoglobin/g of faeces was considered as negative. At this threshold, comparisons between the two systems were made by calculating percentage agreement and Cohen's kappa coefficient. Proportion of negative results were compared with Chi squared testing. Sensitivities for CRC were calculated. RESULTS: A total of 629 included patients provided paired samples for FIT to compare the QuikRead go® and FOB Gold Wide®. The agreement around the negative threshold was 83.0% and Cohen's kappa coefficient was 0.54. The QuikRead go® reported 440/629 (70.0% of samples) as negative compared to 523/629 (83.1%) for the FOB Gold Wide®, this difference was significant (p-value<0.001). Sensitivities for CRC detection by the QuikRead go® and FOB Gold Wide® were 92.9% (95% confidence interval (CI): 68.5-98.7%) and 100% (CI: 78.5-100%) respectively. CONCLUSIONS: Both systems were accurate in their ability to detect CRC. Whilst good agreement around the negative threshold was identified, more patients would be triaged to further colonic investigation if using the QuikRead go®.


Assuntos
Neoplasias Colorretais , Sistemas Automatizados de Assistência Junto ao Leito , Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Fezes/química , Hemoglobinas/análise , Humanos , Laboratórios , Sangue Oculto , Estudos Prospectivos , Sensibilidade e Especificidade
8.
Gut ; 70(6): 1130-1138, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33087488

RESUMO

OBJECTIVE: To assess whether a faecal immunochemical test (FIT) could be used to select patients with suspected colorectal cancer (CRC) symptoms for urgent investigation. DESIGN: Multicentre, double-blinded diagnostic accuracy study in 50 National Health Service (NHS) hospitals across England between October 2017 and December 2019. Patients referred to secondary care with suspected CRC symptoms meeting NHS England criteria for urgent 2 weeks wait referral and triaged to investigation with colonoscopy were invited to perform a quantitative FIT. The sensitivity of FIT for CRC, and effect of relevant variables on its diagnostic accuracy was assessed. RESULTS: 9822 patients were included in the final analysis. The prevalence of CRC at colonoscopy was 3.3%. The FIT positivity decreased from 37.2% to 19.0% and 7.6%, respectively, at cut-offs of 2, 10 and 150 µg haemoglobin/g faeces (µg/g). The positive predictive values of FIT for CRC at these cut-offs were 8.7% (95% CI, 7.8% to 9.7%), 16.1% (95% CI 14.4% to 17.8%) and 31.1% (95% CI 27.8% to 34.6%), respectively, and the negative predictive values were 99.8% (95% CI 99.7% to 99.9%), 99.6% (95% CI 99.5% to 99.7%) and 98.9% (95% CI 98.7% to 99.1%), respectively. The sensitivity of FIT for CRC decreased at the same cut-offs from 97.0% (95% CI 94.5% to 98.5%) to 90.9% (95% CI 87.2% to 93.8%) and 70.8% (95% CI 65.6% to 75.7%), respectively, while the specificity increased from 64.9% (95% CI 63.9% to 65.8%) to 83.5% (95% CI 82.8% to 84.3%) and 94.6% (95% CI 94.1% to 95.0%), respectively. The area under the receiver operating characteristic curve was 0.93 (95% CI 0.92 to 0.95). CONCLUSION: FIT sensitivity is maximised to 97.0% at the lowest cut-off (2 µg/g); a negative FIT result at this cut-off can effectively rule out CRC and a positive FIT result is better than symptoms to select patients for urgent investigations. TRIAL REGISTRATION NUMBER: ISRCTN49676259.


Assuntos
Neoplasias Colorretais/diagnóstico , Sangue Oculto , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Colonoscopia , Método Duplo-Cego , Fezes/química , Feminino , Hemoglobinas/análise , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Encaminhamento e Consulta , Avaliação de Sintomas , Fatores de Tempo , Adulto Jovem
9.
Colorectal Dis ; 23(10): 2539-2549, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34240526

RESUMO

AIM: Detection of early onset colorectal cancer is challenging, and remains a rare diagnosis amongst younger people with gastrointestinal symptoms. We investigated whether faecal immunochemical testing (FIT) could identify younger patients at higher risk of colorectal cancer or serious bowel disease including colorectal cancer, inflammatory bowel disease or advanced adenomas. METHODS: A subgroup analysis was performed of symptomatic patients under 50 years of age (<50) from the NICE FIT study, a multicentre, prospective diagnostic accuracy study of FIT conducted between October 2017 and December 2019. The diagnostic accuracy of FIT for colorectal cancer and serious bowel disease was investigated in younger patients at different faecal haemoglobin (f-Hb) cut-offs of 2, 10 and 150 µg blood/g faeces (µg/g). RESULTS: Early onset colorectal cancer was diagnosed in 1.5% (16/1103) of younger symptomatic patients. The sensitivity of FIT for younger patients aged <50 was 87.5% (95% CI 61.7%-98.4%), 81.3% (54.4%-96.0%) and 68.8% (41.3%-89.0%) at f-Hb cut-offs of 2, 10 and 150 µg/g, respectively. The positive predictive value for colorectal cancer increased from 4.2% (2.3%-6.9%) to 11.5% (5.9%-19.6%) at cut-offs of 2 and 150 µg/g, while the positive predictive value for serious bowel disease increased from 31.3% (26.3%-36.5%) to 65.6% (55.2%-75.0%) at the same cut-offs. The negative predictive value of FIT for colorectal cancer remained above 99.5% at all cut-offs. CONCLUSION: Detectable f-Hb on FIT in symptomatic younger patients may indicate referral for investigation of colorectal cancer and serious bowel disease.


Assuntos
Neoplasias Colorretais , Detecção Precoce de Câncer , Colonoscopia , Neoplasias Colorretais/diagnóstico , Fezes/química , Hemoglobinas/análise , Humanos , Sangue Oculto , Estudos Prospectivos , Sensibilidade e Especificidade
10.
Colorectal Dis ; 23(7): 1622-1629, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33068489

RESUMO

AIM: The COVID-19 pandemic has resulted in the near-complete loss of routine endoscopy services. We describe a major reorganization of service at a regional referral centre (Royal Surrey NHS Foundation Trust) to manage the crisis. Faecal immunochemical testing (FIT) was implemented for triage to make optimum use of limited diagnostic resources. Consultations were switched from face-to-face to telephone. Our aim was to evaluate the impact FIT had on resource allocation and patient diagnoses in the first 3 months of use. METHOD: All colorectal 2-week-wait patient referrals were posted a pack requesting FIT and notification of telephone consultation. A prepaid envelope was included for return of the samples. At consultation, FIT was incorporated with the presenting symptoms to guide the choice of investigation and triage urgency. FIT ≥10 µg/g was interpreted as positive. Outcome data were collected prospectively and compared with retrospective audit data from prepandemic levels across 3 months. RESULTS: From 26 March 2020 to 2 July 381 patients were referred who were invited to provide FIT samples and underwent telephone consultations. Three hundred and fifty eight FIT samples were returned (94%). Onward referral for colonoscopy reduced from 62% to 34% (P < 0.001). There were 14 colorectal cancers (CRC) (3.7%) diagnosed, which was not statistically different from the prepandemic level of 3.9% (P = 0.995). Twelve of the 14 patients with a CRC diagnosis had provided samples; all 12 had FIT ≥10 µg/g and were offered fast-track investigations. CONCLUSIONS: The incorporation of FIT optimized the allocation of limited resources to triage those who required urgent colonic investigation for detecting CRC.


Assuntos
COVID-19 , Neoplasias Colorretais , Estudos de Coortes , Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer , Humanos , Sangue Oculto , Pandemias , Encaminhamento e Consulta , Estudos Retrospectivos , SARS-CoV-2 , Telefone
11.
Colorectal Dis ; 23(7): 1630-1638, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33605522

RESUMO

AIM: The aim of this work was to investigate whether the faecal immunochemical test (FIT) could safely rule out colorectal cancer (CRC) in patients with rectal bleeding (RB). METHOD: This was a multicentre, double-blinded diagnostic accuracy study in 50 National Health Service hospitals. Patients referred from primary care with suspected CRC on an urgent 2-week-wait pathway were asked to perform a FIT prior to colonoscopy. The primary outcome measure was the sensitivity of the FIT for CRC in patients with RB versus nonrectal bleeding symptoms (NRB). The secondary outcome measures included the diagnostic accuracy of the FIT for CRC and other serious bowel disease. RESULTS: Of 9822 patients included in the study, 3143 (32.0%) were referred with RB. CRC was present in 4.7% of patients with RB versus 2.7% of patients with NRB (p < 0.05). Faecal haemoglobin (f-Hb) was detectable (>2 µg/g) in 44.1% of patients with RB and 33.9% with NRB (p < 0.05). In RB patients, CRC was present in 10.4% when f-Hb was >2 µg/g compared with 0.1% when f-Hb was not detected. Flexible sigmoidoscopy in this group would further reduce the risk of CRC to 0.03%. The sensitivity of the FIT for CRC in RB versus NRB groups was 98.6% (95% CI 95.2%-99.8%) vs 95.6% (91.5%-98.1%) for f-Hb >2 µg/g and 96.6% (92.2%-98.9%) vs 86.3 (80.4%-90.9%) for f-Hb >10 µg/g. CONCLUSION: Faecal haemoglobin is not always detectable in patients with RB; 56% of patients had undetectable f-Hb (<2 µg/g) and CRC was present in 0.1%. The high sensitivity of the FIT can be used to rule out CRC in patients with RB and triage them more appropriately for investigation.


Assuntos
Neoplasias Colorretais , Medicina Estatal , Colonoscopia , Neoplasias Colorretais/complicações , Neoplasias Colorretais/diagnóstico , Método Duplo-Cego , Detecção Precoce de Câncer , Fezes/química , Hemoglobinas/análise , Humanos , Sangue Oculto , Sensibilidade e Especificidade
12.
Colorectal Dis ; 23(9): 2376-2386, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34157205

RESUMO

AIM: Laboratory-based faecal immunochemical testing (FIT) is the gold standard for detecting the presence of blood in the stool. The aim was to perform a diagnostic accuracy study to confirm if a point of care (POC) analyser for FIT could be safely used as an adjunct in the triage and management of 2-week wait (TWW) colorectal patients. METHODS: The Point of Care Faecal Immunochemical Testing (POC FIT) prospective observational cohort study was designed for TWW patients at a regional referral centre. Between July 2019 and March 2020, patients were invited to perform and bring a FIT sample to clinic. FIT was completed within the clinic appointment using a POC quantitative analyser that has a 2-min processing time (QuikRead go®). Patients and clinicians were blinded to results within the clinic appointment. The results were compared with subsequent diagnostic outcomes. Faecal haemoglobin of <10 µg haemoglobin/g of faeces was considered a negative result. Sensitivities for colorectal cancer (CRC) and combined serious bowel disease (SBD) were calculated using this pre-determined cut-off. RESULTS: A total of 553 patients were included for analytical comparison with diagnostic outcomes. There were 14 (2.5%) patients with CRC and 52 (9.4%) with SBD. The sensitivities for CRC and SBD were 92.9% (95% CI 68.5%-98.7%) and 76.9% (95% CI 63.9%-86.3%) respectively. 379 (68.5%) patients had a negative FIT result (negative predictive value for CRC was 99.7%). CONCLUSIONS: This POC FIT device is a useful adjunct to better manage TWW patients. The high observed sensitivity for CRC offers opportunities, within a single consultation, for improved triage and rationalization of investigation for those with bowel symptoms.


Assuntos
Neoplasias Colorretais , Sistemas Automatizados de Assistência Junto ao Leito , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer , Fezes/química , Hemoglobinas/análise , Humanos , Sangue Oculto , Estudos Prospectivos , Sensibilidade e Especificidade
13.
Clin Chem Lab Med ; 59(2): 307-313, 2020 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-32772000

RESUMO

Objectives: External quality assessment schemes (EQAS) are being established worldwide to support the faecal immunochemical test (FIT) for haemoglobin (Hb). FIT is widely used as a screening test for colorectal cancer and increasingly in assessment of patients presenting with symptoms. EQA for FIT is provided in several matrices, each unique to the individual scheme. These include Hb suspended in a faecal-like matrix, lyophilised samples and liquid samples. The aim of this study was to evaluate commercially available EQAS and assess their suitability for use. Methods: Ten EQAS provided material for the study. EQA samples were analysed on four quantitative FIT systems. 15 faecal-like matrix samples were loaded per concentration per FIT system. Reconstituted lyophilised samples were examined five times on three separate occasions and liquid samples were examined 10 times per concentration per FIT system. The coefficient of variation (CV) was calculated per concentration of EQA for each FIT system. Results: Results from faecal-like matrix schemes had a higher median CV (12.4-19.0%) when compared to those from schemes providing liquid matrices (0.8-2.3%). The spread of CV values was also higher for results from faecal-like matrix schemes with an interquartile range (IQR) 4.4-24.0% vs. liquid IQR range of 0.3-2.5%. Conclusions: Hb results from faecal-like matrices, whilst more aligned to a patient or participant sample, are prone to pre-examination variation so do not assess the analytical accuracy of a FIT system. Liquid matrices are not prone to pre-examination variation and are better able to assess the accuracy of a FIT system.


Assuntos
Fezes/química , Hemoglobinas/análise , Sangue Oculto , Garantia da Qualidade dos Cuidados de Saúde/métodos , Técnicas e Procedimentos Diagnósticos , Humanos , Imunoensaio , Laboratórios/normas , Padrões de Referência
14.
Clin Chem Lab Med ; 59(1): 173-178, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32692692

RESUMO

Objectives: Faecal immunochemical tests (FIT) for haemoglobin (Hb) are being used in the investigation of colorectal cancer. These tests use antibodies raised to the globin moiety of human Hb. Here, four automated quantitative FIT systems (HM-JACKarc, NS-Prime, OC-Sensor PLEDIA and SENTiFIT 270) are evaluated analytically to confirm whether the performance of the systems meet the manufacturers' claims. Methods: Assessment of the analytical performance of the FIT systems was undertaken using Hb lysates, real patient samples and external quality assessment (EQA) samples. This analytical assessment focused on detection characteristics, imprecision, linearity, prozone effect, recovery and carryover. Results: All four methods demonstrated good analytical performance, with acceptable within- and between-run imprecision, good recovery of f-Hb and limited carryover of samples. They also all show good linearity across the range of concentrations tested. The results of EQA samples showed different variations from the target values (-52 to 45%), due to the absence of standardisation across the different methods. Conclusions: All four systems are fit for purpose and have an analytical performance as documented by their manufacturers.


Assuntos
Neoplasias Colorretais/diagnóstico , Fezes/química , Hemoglobinas/análise , Detecção Precoce de Câncer/métodos , Humanos , Imunoensaio/métodos
15.
Clin Chem Lab Med ; 58(6): 1010-1017, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-31851610

RESUMO

Background Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantages over immunoassay due to its increased specificity and ability to multiplex metabolites within a single run. Wide scale adoption of LC-MS/MS in routine clinical laboratories is restricted in part due to the high level of technical expertise required. The Thermo Scientific™ Cascadion™ SM Clinical Analyzer is the first fully automated, random access clinical analyser that utilises LC-MS/MS technology. We report an analytical validation of the 25-hydroxy vitamin D2 and D3 assays on the Cascadion Analyzer and an assessment of its performance within a routine clinical laboratory. Methods Analyser usability was assessed by staff with no previous experience of LC-MS/MS. An analytical validation included analysis of 154 patient samples on two different Cascadion Analyzers and a four-way method comparison of 146 patient samples on Roche and Siemens immunoassays and an in-house LC-MS/MS method. Accuracy was assessed using external quality assurance and reference materials. Seven third party IQC materials were tested on Cascadion. Results Cascadion proved easy to use by scientific and non-scientific staff. The assay passed all validation criteria. Excellent agreement was demonstrated between two different Cascadions (y = 0.97x + 3.9 nmol/L, r2 > 0.99). A method comparison demonstrated no significant difference (p > 0.05) between the Cascadion and the Roche immunoassay. A significant difference (p < 0.0001) was observed between the Cascadion and an LC-MS/MS and Siemens methods. Results obtained from EQA and reference material showed a mean bias of +3.09% and all samples were within ±10% of assigned concentrations. All third party IQC samples tested were compatible for use with Cascadion. Conclusions The Cascadion Analyzer is a fully automated LC-MS/MS system that requires no prior LC-MS/MS expertise. The vitamin D assays demonstrated excellent performance with high levels of accuracy.


Assuntos
Análise Química do Sangue/métodos , Cromatografia Líquida , Laboratórios , Espectrometria de Massas em Tandem , Vitamina D/análogos & derivados , Automação , Humanos , Vitamina D/sangue
16.
Clin Chem Lab Med ; 57(5): 611-616, 2019 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-29995629

RESUMO

Faecal immunochemical tests for haemoglobin (FIT) are widely used in asymptomatic population screening for colorectal (bowel) cancer. FIT are also used to assist with the assessment of patients presenting with lower abdominal symptoms. Quantitative FIT allow the generation of numerical estimates of faecal haemoglobin (f-Hb) concentrations. There is now great interest in "low" f-Hb concentrations in these clinical settings: in consequence, knowledge of the detection capability is very important for f-Hb concentration examinations. There are a number of current problems associated with the reporting of low f-Hb concentrations and wide misunderstanding of the metrological aspects of examinations of f-Hb at low concentrations. These would be solved if the detectability characteristics of f-Hb concentration examinations, namely, the limit of blank (LoB), limit of detection (LoD) and limit of quantitation (LoQ), were generated, validated and used in reporting systems exactly as recommended in the EP17-A2 guideline of the Clinical Laboratory Standards Institute. LoB and LoD are statistical concepts, but the LoQ depends on definition of analytical performance specifications (APS). In this Opinion Paper proposals for interim APS are made, based on the current state of the art achieved with examinations of faecal samples. It is proposed that LoQ is determined at an examination imprecision of CV≤10% using faecal samples naturally positive for Hb rather than faeces spiked with haemolysate. Detailed proposals for reporting f-Hb data at low concentrations are also made.


Assuntos
Fezes/química , Hemoglobinas/análise , Imunoquímica/normas , Humanos , Imunoquímica/métodos , Limite de Detecção
17.
Br J Cancer ; 116(12): 1551-1557, 2017 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-28524157

RESUMO

BACKGROUND: The NHS Bowel Cancer Screening Programme (BCSP) in England does not involve general practitioners (GPs). Uptake is ∼58%. The Practice Endorsed Additional Reminder Letter (PEARL) study piloted a GP-endorsed reminder letter. METHODS: General practices in Wessex with uptake <55% (prevalent invitations) were invited to participate. Subjects who had been invited for screening, sent a standard 28-day BCSP reminder letter but had not returned a test kit within 30 days of the standard reminder were sent a second reminder letter bearing the GP's letterhead and signature. Uptake was compared between PEARL and non-PEARL practices by standardised uptake ratio (standardised for prior prevalent uptake and other confounders). In addition, 25 non-PEARL practices were matched with PEARL practices for prior prevalent uptake and number of invitees. RESULTS: Twenty-five practices agreed to participate. A total of 3149 GP-endorsed reminders were sent. Uptake in the PEARL practices was 54% compared with 51% in the matched-control practices. The adjusted RR for uptake was 1.08 (95% CI: 1.05, 1.11, P<0.001) for all invitees and 2.18 (1.79, 2.66, P<0.001) for invitees who had not returned a kit following the standard reminder. CONCLUSIONS: The GP-endorsed reminder was associated with significantly increased uptake among subjects not responding to the standard reminder letter.


Assuntos
Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/estatística & dados numéricos , Medicina Geral/estatística & dados numéricos , Sangue Oculto , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Papel do Médico , Idoso , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Sistemas de Alerta
20.
Curr Gastroenterol Rep ; 17(2): 428, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25673567

RESUMO

Screening for colorectal cancer (CRC) reduces CRC mortality; many countries have implemented population-based CRC screening programmes and many more are poised to do so. Whilst several different CRC screening modalities are available, choice will be influenced by cost, available resources (e.g. high-quality colonoscopy) and acceptability of the test by the invited population. For CRC screening, no screening test has so far surpassed the practicality, affordability and effectiveness of tests for the presence of blood in faeces (faecal occult blood tests, FOBt). The results of several large FOBt-based randomised controlled trials provide the best clinical evidence to support their use in population-based CRC screening. This review considers the current options for CRC screening and the future for FOBt.


Assuntos
Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Sangue Oculto , Biomarcadores/análise , Colonoscopia , DNA de Neoplasias/análise , Fezes/química , Guaiaco , Hemoglobinas/análise , Humanos , Imunoquímica , Indicadores e Reagentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA