Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Prenat Diagn ; 38(4): 293-297, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29417606

RESUMO

OBJECTIVES: The objective of our study was to determine the impact of laser therapy for twin-to-twin transfusion syndrome (TTTs) on subsequent pregnancies. METHODS: This was a monocentric retrospective observational study. Women treated by laser fetoscopy for TTTs were asked to answer a postal questionnaire about subsequent pregnancies. The primary outcome was fecundity (number of pregnancies and time to pregnancy). We also assessed pregnancy complications, birth weight, and gestational age at delivery. Pregnancy complications included the following: threatened preterm labor, preeclampsia, placenta accreta, postpartum hemorrhage, and psychological disorders. Our study population was compared with an external control group made up of mothers of monochorionic twins without TTTs. RESULTS: We included 122 cases managed at the Necker Hospital between 2008 and 2012 and 39 controls. The median conception time was longer in the TTTs group (6.4 ± 11.1 versus 2 ± 1.6 months, P = .03). The numbers of live childbirths at the end of those pregnancies were equivalent (77.6% versus 66.7%, P = .56). Birth weight (3317 ± 726 versus 3240 ± 382 g, P = .81) and gestational age at delivery (38.2 ± 6.8 WG versus 39.5 ± 1.2 WG, P = .64) were similar, with no increase of obstetrical complications compared with the control group. DISCUSSION: Twin-to-twin transfusion syndrome and its treatment do not seem to impact subsequent pregnancies.


Assuntos
Transfusão Feto-Fetal/cirurgia , Complicações Pós-Operatórias/epidemiologia , Adulto , Feminino , Fetoscopia , França/epidemiologia , Humanos , Fotocoagulação a Laser , Gravidez , Estudos Retrospectivos
2.
J Ultrasound Med ; 36(11): 2279-2285, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28600890

RESUMO

OBJECTIVES: To evaluate the feasibility and impact of using a software-supported protocol for routine second-trimester ultrasound scanning. METHODS: We conducted a comparative observational study of 2 sets of 25 randomly selected normal routine second-trimester examinations performed by the same expert sonographer before and 1 year after the introduction of a software-supported protocol. The scanning protocol was identical during both periods and conformed to International Society of Ultrasound in Obstetrics and Gynecology guidelines. Two independent expert sonographers reviewed the temporal sequences of fetal anatomic visualization. The examination duration, number of images, time per stored image, and number of recorded anatomic features according to the International Society of Ultrasound in Obstetrics and Gynecology guidelines were compared between the periods. RESULTS: The mean examination duration and the number of images stored ± SD were both significantly higher during the period with the software-supported protocol than during the previous period (18.9 ± 5.3 versus 15.3 ± 2.8 minutes, respectively; P = .005; and 52.0 ± 2.4 versus 35.2 ± 3.4; P < .001). The mean time per image was also shorter with the software-supported protocol (19 ± 7 versus 26 ± 4 seconds; P < .001). Recording of the placental location, amniotic fluid quantification, cavum septi pellucidi, thoracic shape, both kidneys, both arms, and genitalia was significantly more consistent with the software-supported protocol (P < .001; P = .001; P = .022; P = .050; P = .022; P < .001; and P = .048). CONCLUSIONS: This pilot study suggests that a software-supported protocol standardizing image acquisition may improve operator efficiency during second-trimester ultrasound scans.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Segundo Trimestre da Gravidez , Ultrassonografia Pré-Natal/métodos , Estudos de Viabilidade , Feminino , Humanos , Projetos Piloto , Gravidez
3.
Am J Hum Genet ; 91(6): 1135-43, 2012 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-23217329

RESUMO

Cobblestone lissencephaly is a peculiar brain malformation with characteristic radiological anomalies. It is defined as cortical dysplasia that results when neuroglial overmigration into the arachnoid space forms an extracortical layer that produces agyria and/or a "cobblestone" brain surface and ventricular enlargement. Cobblestone lissencephaly is pathognomonic of a continuum of autosomal-recessive diseases characterized by cerebral, ocular, and muscular deficits. These include Walker-Warburg syndrome, muscle-eye-brain disease, and Fukuyama muscular dystrophy. Mutations in POMT1, POMT2, POMGNT1, LARGE, FKTN, and FKRP identified these diseases as alpha-dystroglycanopathies. Our exhaustive screening of these six genes, in a cohort of 90 fetal cases, led to the identification of a mutation in only 53% of the families, suggesting that other genes might also be involved. We therefore decided to perform a genome-wide study in two multiplex families. This allowed us to identify two additional genes: TMEM5 and ISPD. Because TMEM has a glycosyltransferase domain and ISPD has an isoprenoid synthase domain characteristic of nucleotide diP-sugar transferases, these two proteins are thought to be involved in the glycosylation of dystroglycan. Further screening of 40 families with cobblestone lissencephaly identified nonsense and frameshift mutations in another four unrelated cases for each gene, increasing the mutational rate to 64% in our cohort. All these cases displayed a severe phenotype of cobblestone lissencephaly A. TMEM5 mutations were frequently associated with gonadal dysgenesis and neural tube defects, and ISPD mutations were frequently associated with brain vascular anomalies.


Assuntos
Lissencefalia Cobblestone/genética , Proteínas de Membrana/genética , Mutação , Nucleotidiltransferases/genética , Alelos , Lissencefalia Cobblestone/diagnóstico , Consanguinidade , Éxons , Família , Feto/metabolismo , Feto/patologia , Ordem dos Genes , Genótipo , Humanos , Íntrons , Pentosiltransferases
4.
Cytogenet Genome Res ; 147(2-3): 103-10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26735902

RESUMO

Cytogenetic microarray analysis is now the first-tier genetic test used in a postnatal clinical setting to explore genomic imbalances in individuals with developmental disability and/or birth defects. However, in a prenatal setting, this technique is not widely implemented, largely because the clinical impact of some copy number variants (CNVs) remains difficult to assess. This limitation is especially true in France where termination of pregnancy for medical reasons may be performed at any stage of gestation. During a period of 15 months, we investigated 382 fetuses presenting with ultrasound anomalies, using a customized microarray designed to avoid the detection of CNVs raising challenges for genetic counseling. After excluding common aneuploidies, 20/374 (5.3%) fetuses had a pathogenic CNV, among which 12/374 (3.2%) could have been detected by karyotyping, whereas 8/374 (2.1%) were cryptic. Within these 374 cases, 300 were ongoing pregnancies at the time of array comparative genomic hybridization (aCGH) testing. For these pregnancies, we detected 18/300 (6%) pathogenic CNVs, among which 6/300 (2%) were cryptic. Using this approach, only 2/300 (0.6%) of the detected CNVs raised difficulties for genetic counseling. This study confirms the added value of this strategy in a prenatal clinical setting to minimize ethical issues for genetic counseling while enhancing the detection of genomic imbalances.


Assuntos
Variações do Número de Cópias de DNA , Feto/metabolismo , Testes Genéticos/métodos , Análise em Microsséries/métodos , Ultrassonografia Pré-Natal/métodos , Aberrações Cromossômicas/embriologia , Hibridização Genômica Comparativa , Feminino , Doenças Fetais/diagnóstico , Doenças Fetais/diagnóstico por imagem , Doenças Fetais/genética , França , Aconselhamento Genético , Humanos , Cariotipagem , Gravidez , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Clin Oral Implants Res ; 25(5): 539-45, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23413956

RESUMO

OBJECTIVE: The aim of this review was to test the hypothesis that 6 mm micro-rough short Straumann(®) implants provide predictable survival rates and verify that most failures occurring are early failures. MATERIALS AND METHODS: A PubMed and hand search was performed to identify studies involving micro-rough 6-mm-short implants published between January 1987 and August 2011. Studies were included that (i) involve Straumann(®) 6 mm implants placed in the human jaws, (ii) provide data on the survival rate, (iii) mention the time of failure, and (iv) report a minimum follow-up period of 12 months following placement. A meta-analysis was performed on the extracted data. RESULTS: From a total of 842 publications that were screened, 12 methodologically sound articles qualified to be included for the statistical evaluation based on our inclusion criteria. A total of 690 Straumann(®) 6-mm-short implants were evaluated in the reviewed studies (Total: placed-690, failed-25; maxilla: placed-266, failed-14; mandible: placed-364, failed-5; follow-up period: 1-8 years). A meta-analysis was performed on the calculated early cumulative survival rates (CSR%). The pooled early CSR% calculated in this meta-analysis was 93.7%, whereas the overall survival rates in the maxilla and mandible were 94.7% and 98.6% respectively. Implant failures observed were predominantly early failures (76%). CONCLUSION: This meta-analysis provides robust evidence that micro-rough 6-mm-short dental implants are a predictable treatment option, providing favorable survival rates. The failures encountered with 6-mm-short implants were predominantly early and their survival in the mandible was slightly superior.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Humanos , Propriedades de Superfície
6.
Hum Reprod ; 28(4): 1110-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23340057

RESUMO

STUDY QUESTION: When, within the female cycle, does conception occur in spontaneously fertile cycles? SUMMARY ANSWER: This study provides reference values of day-specific probabilities of date of conception in ongoing pregnancies. The maximum probability of being within a 5-day fertile window was reached on Day 12 following the last menstrual period (LMP). WHAT IS KNOWN ALREADY: The true date of conception is not observable and may only be estimated. Accuracy of these estimates impacts on obstetric management of ongoing pregnancies. Timing of ovulation and fertility has been extensively studied in prospective studies of non-pregnant fertile women using error-prone proxies, such as hormonal changes, body-basal temperature and ultrasound, yielding day-specific probabilities of conception and fertile windows. In pregnant women, date of conception may be retrospectively estimated from early pregnancy fetal measurement by ultrasound. STUDY DESIGN, SIZE, DURATION: Retrospective analysis of consecutive pregnancies in women referred for routine first-trimester screening, over a 3-year period (2009-2011) in a single ultrasound center (n = 6323). PARTICIPANTS/MATERIALS, SETTING, METHODS: Within the overall population, 5830 cases with a certain date of last menses were selected for analysis. The date of conception was estimated using a crown-rump length biometry and an equation derived from IVF/ICSI pregnancies. Day-specific probabilities of conception were estimated across several covariates, including age, cycle characteristics and ethnicity, using deconvolution methods to account for measurement error. MAIN RESULTS AND THE ROLE OF CHANCE: Overall, the day-specific probability of conception sharply rises at 7 days after the LMP, reaching its maximum at 15 days and returning to zero by 25 days. Older women tend to conceive earlier within their cycle, as did women with regular cycles and white and black women compared with Asian ethnicity. The probability of being within the fertile window was 2% probability at Day 4, a maximum probability of 58% at Day 12 and a 5% probability by Day 21 of the cycle. LIMITATIONS, REASONS FOR CAUTION: Although conception is believed to occur within hours following ovulation, a discrepancy is theoretically possible. However, when comparing our results to those of prospective studies, no such difference was found. The equation used for estimating the date of pregnancy was estimated in IVF/ICSI pregnancies, which could lead to potential bias in spontaneous pregnancies. However, in our population, the observed bias was negligible. Non-fertile cycles and early pregnancy losses are necessarily overlooked because of the nature of our data. WIDER IMPLICATIONS OF THE FINDINGS: Because of the wider access to retrospective data and the potential bias in prospective studies of ovulation monitoring, this study should broaden the perspectives of future epidemiologic research in fertility and pregnancy monitoring. STUDY FUNDING/COMPETING INTERESTS: None.


Assuntos
Fertilização , Ciclo Menstrual , Gravidez/fisiologia , Probabilidade , Adulto , Fatores Etários , Estatura Cabeça-Cóccix , Feminino , Humanos , Gravidez/etnologia , Estudos Retrospectivos , Fatores de Tempo
7.
Am J Obstet Gynecol ; 209(3): 223.e1-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23673229

RESUMO

OBJECTIVE: Screening at 11-13 weeks with ultrasound biparietal diameter (BPD) can detect half of open spina bifida cases. Maternal serum α-fetoprotein (AFP) levels at 15-19 weeks are increased 3- to 4-fold, in open spina bifida. We assessed whether combined screening using BPD, AFP, and other serum markers at 11-13 weeks would increase detection. STUDY DESIGN: Maternal AFP levels were measured on serum stored at 11-13 weeks in 44 open spina bifida and 182 unaffected pregnancies, and results were expressed in multiples of the median (MoM) for gestational age. All samples had been measured for free ß-human chorionic gonadotropin (ß-hCG) and pregnancy-associated plasma protein (PAPP)-A. A multivariate Gaussian model was used to predict screening performance from the serum data and BPD measurements on 80 cases, including 36 previously published. RESULTS: The median AFP level in cases was 1.201 MoM, significantly higher than in unaffected pregnancies (P < .01, 1 tail). The median free ß-hCG was significantly reduced to 0.820 MoM (P < .02), but the median PAPP-A was similar in cases and controls. Modeling predicted the following: BPD alone would detect 50% of cases for a 5% false-positive rate or 63% for 10%; adding AFP increases detection by 2%; and a combined test with BPD, AFP, and free ß-hCG detects 58% for 5% or 70% for 10%. CONCLUSION: Combining AFP and BPD with free ß-hCG as part of first-trimester aneuploidy screening would also allow early detection about two-thirds of cases with open spina bifida.


Assuntos
Biomarcadores/sangue , Gonadotropina Coriônica Humana Subunidade beta/sangue , Espinha Bífida Cística/diagnóstico , Ultrassonografia Pré-Natal , alfa-Fetoproteínas/análise , Adulto , Reações Falso-Positivas , Feminino , Humanos , Gravidez , Proteína Plasmática A Associada à Gravidez/análise , Espinha Bífida Cística/diagnóstico por imagem
8.
Am J Obstet Gynecol ; 209(2): 148.e1-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23685001

RESUMO

OBJECTIVE: A combination of magnetic resonance imaging (MRI) images with real time high-resolution ultrasound known as fusion imaging may improve prenatal examination. This study was undertaken to evaluate the feasibility of using fusion of MRI and ultrasound (US) in prenatal imaging. STUDY DESIGN: This study was conducted in a tertiary referral center. All patients referred for prenatal MRI were offered to undergo fusion of MRI and US examination. All cases underwent 1.5 Tesla MRI protocol including at least 3 T2-weighted planes. The Digital Imaging and Communications in Medicine volume dataset was then loaded into the US system for manual registration of the live US image and fusion imaging examination. RESULTS: Over the study period, 24 patients underwent fusion imaging at a median gestational age of 31 (range, 24-35) weeks. Data registration, matching and then volume navigation was feasible in all cases. Fusion imaging allowed superimposing MRI and US images therefore providing with real time imaging capabilities and high tissue contrast. It also allowed adding a real time Doppler signal on MRI images. Significant fetal movement required repeat-registration in 15 (60%) cases. The average duration of the overall additional scan with fusion imaging was 10 ± 5 minutes. CONCLUSION: The combination of fetal real time MRI and US image fusion and navigation is feasible. Multimodality fusion imaging may enable easier and more extensive prenatal diagnosis.


Assuntos
Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Ultrassonografia Pré-Natal/métodos , Feminino , Idade Gestacional , Humanos , Gravidez , Estudos Prospectivos
9.
Clin Oral Implants Res ; 24(11): 1257-64, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22925088

RESUMO

OBJECTIVES: (1) To measure and compare endo-sinus bone levels around implants randomly placed with an osteotome sinus floor elevation (OSFE) procedure in grafted (control) and non-grafted (test) sinuses, (2) to evaluate the OSFE efficacy with short, tapered, and chemically modified hydrophilic surfaced implants in extremely atrophic maxillae, (3) to show that fused corticals may constitute a complication risk. MATERIAL AND METHODS: The TE(®) SLActive 8 mm-long implants (Straumann AG) were placed using an OSFE procedure in 4 mm or less of bone height. Healing time before prosthetic rehabilitation was 10 weeks. One year after implant placement, bone levels were measured on standardized periapical radiographs. RESULTS: Thirty-seven (17 tests, 20 controls) implants were placed in 12 patients with a mean maxillary residual bone height (RBH) of 2.4 ± 0.9 mm. Before loading, two control implants failed (RBH 1.4 and 1.2 mm); two others rotated at loading (one test, RBH 0.9 mm; one control, RBH 1.5 mm) but were uneventfully loaded after three additional months of healing. These adverse events and complications occurred when implants were placed in merged corticals. Endo-sinus bone gain was 3.9 ± 1.0 and 5.0 ± 1.3 mm for the test and control groups (P = 0.003). The 1-year success rate was 100% and 90%, respectively (P = 0.49). CONCLUSION: Although more bone is gained when grafting material is used, this may not be required to promote endo-sinus bone gain. The OSFE procedure with or without grafting material could be efficient when the RBH is ≤ 4 mm. However, when both corticals merged, the risk of complication could increase.


Assuntos
Perda do Osso Alveolar/cirurgia , Transplante Ósseo , Implantação Dentária Endóssea/métodos , Implantes Dentários , Maxila/cirurgia , Osteotomia/métodos , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/patologia , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Feminino , Humanos , Masculino , Maxila/diagnóstico por imagem , Maxila/patologia , Pessoa de Meia-Idade , Minerais/farmacologia , Radiografia , Retalhos Cirúrgicos , Resultado do Tratamento
10.
Implant Dent ; 22(3): 295-303, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23644909

RESUMO

OBJECTIVES: The aims were to investigate whether the use of platelet-rich fibrin membranes (PRF) for socket filling could improve microarchitecture and intrinsic bone tissue quality of the alveolar bone after premolar extraction and to assess the influence of the surgical procedure before implant placement. MATERIAL AND METHODS: Twenty-three patients requiring premolar extraction followed by implant placement were randomized to three groups: (1) simple extraction and socket filling with PRF, (2) extraction with mucosal flap and socket filling with PRF, and (3) controls with simple extraction without socket filling. Implant placement was performed at week 8, and a bone biopsy was obtained for histomorphometric analysis. RESULTS: Analysis by microcomputed tomography showed better bone healing with improvement of the microarchitecture (P < 0.05) in group 1. This treatment had also a significant effect (P < 0.05) on intrinsic bone tissue quality and preservation of the alveolar width. An invasive surgical procedure with a mucosal flap appeared to completely neutralize the advantages of the PRF. CONCLUSIONS: These results support the use of a minimally traumatic procedure for tooth extraction and socket filling with PRF to achieve preservation of hard tissue.


Assuntos
Plaquetas , Regeneração Óssea/efeitos dos fármacos , Fibrina/farmacologia , Membranas Artificiais , Extração Dentária , Alvéolo Dental/efeitos dos fármacos , Adulto , Idoso , Perda do Osso Alveolar/etiologia , Processo Alveolar/efeitos dos fármacos , Análise de Variância , Implantação Dentária Endóssea , Ingestão de Alimentos , Feminino , Testes de Dureza , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Inquéritos e Questionários , Extração Dentária/efeitos adversos , Extração Dentária/métodos , Alvéolo Dental/diagnóstico por imagem , Cicatrização/efeitos dos fármacos , Microtomografia por Raio-X , Adulto Jovem
11.
Am J Obstet Gynecol ; 207(4): 306.e1-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22683101

RESUMO

OBJECTIVE: Prenatal screening for aneuploidies is best achieved in the first trimester when there is no reliable screening test for spina bifida. Early ultrasound features may be too complex for routine screening. We assessed screening potential of simple and reproducible fetal biometric measurements at 11-14 weeks of gestation. STUDY DESIGN: A total of 34,951 unselected consecutive pregnancies included 18 with spina bifida. Another 28 cases were referred for assessment. Biometric measurements were expressed in multiples of the median for crown-rump length. RESULTS: Biparietal diameter (BPD) was smaller in spina bifida (P < .0001). In all, 22 of 44 (50%) cases with spina bifida aperta had a BPD <5th centile. BPD was independent of maternal adiposity and smoking status. CONCLUSION: Simple and reproducible BPD at 11-14 weeks of gestation could detect half the cases of open fetal spina bifida by identifying 5% of pregnancies for expert scanning in first- and second-trimester examinations of the fetal spine and cranium.


Assuntos
Cefalometria/métodos , Cabeça/diagnóstico por imagem , Disrafismo Espinal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Estatura Cabeça-Cóccix , Feminino , Humanos , Gravidez , Primeiro Trimestre da Gravidez
12.
Prenat Diagn ; 32(9): 869-74, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22692804

RESUMO

OBJECTIVE: We examined the outcomes of pregnancies in which the fetal head circumference (HC) was below the 5(th) centile at the routine second-trimester scan. MATERIALS AND METHODS: We retrospectively analysed outcomes of 18,377 women according to HC Z scores at second-trimester ultrasound examination between 2001 and 2008. We collected all major malformations, intrauterine deaths and other abnormal outcomes. RESULTS: Six hundred seventy-four fetuses (3.7%) had an HC below the 5(th) centile. Twenty-one major malformations were noted, consisting mainly of neurological abnormalities (3.1%). There were seven intra uterine fetal death (1.3%). Of all the fetuses, 26% were lost to follow-up. Outcome and neurological development was normal in 467 cases, based on neonatal examination and/or parent or general practitioner reports. Major abnormalities were noted in respectively 26.2%, 3.0% and 1.1% of fetuses with Z scores < -2.5, -2.5 to -2.0, and -2 to -1.645, compared with 0.3% of fetuses with normal HC (p < 10(-4)). CONCLUSION: A head circumference below the 5(th) centile at second-trimester scan is associated with various abnormalities, especially neurological disorders. The outcome was worse when the HC was smaller. An HC Z score below -2.5 was strongly associated with neurological and chromosomal abnormalities. Conversely, an HC Z score below -1.645 but above -2, excluding cases with prenatally diagnosed malformations, seems to be reassuring for favorable neonatal outcome.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Resultado da Gravidez/epidemiologia , Segundo Trimestre da Gravidez , Ultrassonografia Pré-Natal , Feminino , Retardo do Crescimento Fetal/epidemiologia , Feto/anatomia & histologia , Idade Gestacional , Cabeça/anatomia & histologia , Cabeça/embriologia , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Malformações do Sistema Nervoso/diagnóstico por imagem , Malformações do Sistema Nervoso/embriologia , Malformações do Sistema Nervoso/epidemiologia , Gravidez , Complicações na Gravidez/diagnóstico por imagem , Complicações na Gravidez/epidemiologia , Projetos de Pesquisa , Estudos Retrospectivos , Design de Software , Ultrassonografia Pré-Natal/estatística & dados numéricos
13.
Clin Oral Implants Res ; 23(5): 577-83, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22092337

RESUMO

OBJECTIVE: The aim of this study was to compare tactile sensitivity and maximum voluntary bite force (MBF) of edentulous patients with implant-supported fixed dental prostheses (IFDP/IFDPs) to those wearing complete dentures (CG-CC) and fully dentate subjects (CG-DD). METHODS: Seven edentulous subjects with IFDP/IFDPs, seven with CG-CC and seven CG-DD, matched for age and gender, participated in the pilot experiments. Three active tactile thresholds (absolute, 50% and 100%) were evaluated by means of copper foils of decreasing thickness (12 foils: 700-5 µm). The passive thresholds were measured in six different sites per quadrant using a custom-made computer-supported strain gauge. MBF was evaluated electronically using the central-bearing point method. RESULTS: Active tactile thresholds were different between all three groups of dental state (Kruskal-Wallis: absolute P = 0.0156; 50% P = 0.0019; 100% P = 0.0059). The active tactile sensitivity with IFDP/IFDPs was between those of the two other groups, except for the 100% threshold. The median passive tactile threshold was higher in patients with IFDP/IFDPs (5.7 N) than in CG-CC (1.7 N) and CG-DD (0.5 N) (Kruskal-Wallis P < 0.0005). MBF did not differ significantly between the dental states (ns). CONCLUSION: IFDP/IFDPs are a valuable treatment option for restoring edentulous patients. Limitations concerning their physiological integration into the orofacial system are mainly related to a poor passive rather than active tactile sensitivity or maximum bite force.


Assuntos
Força de Mordida , Prótese Dentária Fixada por Implante , Arcada Edêntula/reabilitação , Propriocepção/fisiologia , Tato/fisiologia , Idoso , Análise do Estresse Dentário , Prótese Total , Feminino , Humanos , Masculino , Maxila , Mecanorreceptores , Limiar Sensorial , Estatísticas não Paramétricas
14.
J Obstet Gynaecol Res ; 38(5): 832-40, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22413992

RESUMO

AIMS: The aim of this study was to assess the diagnostic performance of 3-D contrast-enhanced power Doppler ultrasonography (3-D CEPDUS) for differentiating benign and malignant adnexal masses. MATERIAL AND METHODS: Consecutive patients with adnexal masses were included prospectively and underwent 2-D ultrasonography and 3-D CEPDUS in a tertiary centre in Paris, France. The main outcome measure was the diagnostic accuracy of 3-D CEPDUS to diagnose malignant and borderline adnexal masses. The reference standard was the final histological examination. Two-dimensional ultrasonography and 3-D CEPDUS were compared using semiquantitative scores. Three-dimensional CEPDUS assessed vessel density, vessel pattern, and three vascular indexes in a 5-mL region of interest (vascularization index [VI], flow index [FI], and vascularization flow index [VFI]). The 2-D and 3-D examinations were done by different sonographers who were blinded to the other test. The pathologist was blinded to ultrasonography findings. RESULTS: Of 99 patients, 88 had benign tumors and were compared to the 11 patients with borderline (n = 5) or malignant (n = 6) tumors. The sensitivity of the subjective 2-D score was 55% (95% confidence interval [CI], 25-84) and specificity 94% (95%CI, 89-99). The sensitivity of the subjective 3-D score was 82% (95%CI, 58-100) and specificity 90% (95%CI, 83-96). Improvement of detection of malignant or borderline tumors by subjective 3-D score was 150%. Vessel density and patterns were not more efficient than the subjective 3-D score. The mean vascular index values were significantly different between benign and borderline/malignant groups: VI, 7.2 versus 35.5 (P < 0.0001); FI, 37.0 versus 48.2 (P = 0.003); and VFI, 2.9 versus 17.6 (P < 0.0001), respectively. CONCLUSIONS: 3-D CEPDUS improves detection of malignant and borderline adnexal masses.


Assuntos
Neovascularização Patológica/diagnóstico por imagem , Neoplasias Ovarianas/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Sensibilidade e Especificidade
15.
Implant Dent ; 21(3): 213-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22526141

RESUMO

OBJECTIVES: The aims of this study were (1) to evaluate the vertical shrinkage percentage of nanocrystalline hydroxyapatite embedded in silica gel used for maxillary sinus floor elevation (SFE) and (2) to determine the survival rate of the implants 1 year after placement in the healed grafted sinuses. MATERIALS AND METHODS: Eleven maxillary sinuses were augmented in eight patients with NanoBone. After a healing period averaging 14.42 months, 19 implants were placed and followed up with clinical and radiographic evaluation. Panoramic radiographs were taken immediately after SFE and at 12 months after grafting. Measurements of changes in height were made by a computerized measuring technique using an image editing software. RESULTS: The mean graft height shrinkage percentage at 12 months after surgery was 8.84% (±5.32). One implant was lost before loading. All the 18 remaining osseointegrated implants received the prosthetic rehabilitation and were controlled after 3 months of functional loading. The implant survival rate at the 1-year interval was 94.74%. CONCLUSIONS: A 100% NanoBone alloplastic graft used in lateral SFE procedures presented limited height shrinkage. Implants placed in these grafted sinuses showed survival rates similar to those found in published data. These results should be interpreted cautiously considering the study's reduced sample size.


Assuntos
Substitutos Ósseos , Implantação Dentária Endóssea , Durapatita , Dióxido de Silício , Levantamento do Assoalho do Seio Maxilar/métodos , Coroas , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Combinação de Medicamentos , Humanos , Processamento de Imagem Assistida por Computador , Estudos Prospectivos , Radiografia Panorâmica
16.
Implant Dent ; 21(5): 422-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22968571

RESUMO

OBJECTIVES: To evaluate the long-term survival rate of rough-surfaced implants placed in maxillary sinuses augmented with deproteinized bovine bone (Bio-Oss; Geistlich Pharma AG, Wolhusen, Switzerland). MATERIALS AND METHODS: Thirteen maxillary sinuses were augmented in 10 patients with Bio-Oss. After an average healing period of 13.8 months, 24 implants were placed. In 4 cases, biopsies were performed and submitted to histological analysis. Clinical and radiographic evaluation was performed 9 years after implant placement and minimum 8 years after functional loading. RESULTS: At the 9-year control, all the 24 implants were still functional. Thus, the implant survival rate was 100%. CONCLUSIONS: Bio-Oss is an acceptable substitute to the autogenous bone, and it can be used as a unique material for sinus floor elevation. Rough-surfaced implants placed in 100% Bio-Oss grafts showed a high survival rate (100%) on the long term. Larger clinical trials are necessary to confirm our results.


Assuntos
Substitutos Ósseos , Implantação Dentária Endóssea , Arcada Parcialmente Edêntula/reabilitação , Seio Maxilar/cirurgia , Minerais , Levantamento do Assoalho do Seio Maxilar/métodos , Adulto , Animais , Bovinos , Implantes Dentários , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Propriedades de Superfície , Titânio
17.
Am J Obstet Gynecol ; 205(6): 547.e1-6, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21907956

RESUMO

OBJECTIVE: We sought to describe the potential value of 11-14 weeks' screening for placenta accreta (PA). STUDY DESIGN: Patients with a history of lower segment cesarean section were prospectively included between 11-13+6 weeks over a 1.5-year period. The first 258 were offered standard screening whereas the following 105 underwent screening for PA. Women were considered high-risk when the trophoblast overlapped the scar visualized by transvaginal ultrasound and low-risk otherwise. RESULTS: The group screened for PA did not differ from the nonscreened group for demographic characteristics. In all, 6 of 105 (5.8%) women were considered high-risk. In the nonscreened group, 1 case of PA was discovered during an elective repeat cesarean. In the screened population, 1 case of PA occurred in a high-risk patient allowing a conservative planned management at 35 weeks. CONCLUSION: At 11-14 weeks, ultrasound may help risk stratification for PA with a specific follow-up. Early recognition of patients at risk might improve the perinatal outcome of PA.


Assuntos
Placenta Acreta/diagnóstico por imagem , Primeiro Trimestre da Gravidez , Ultrassonografia Pré-Natal , Adulto , Cesárea/efeitos adversos , Cesárea/estatística & dados numéricos , Cicatriz/diagnóstico por imagem , Cicatriz/epidemiologia , Feminino , Idade Gestacional , Humanos , Programas de Rastreamento , Placenta Acreta/epidemiologia , Gravidez , Estudos Prospectivos , Fatores de Risco , Trofoblastos/diagnóstico por imagem
18.
Am J Obstet Gynecol ; 205(6): 551.e1-6, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21893310

RESUMO

OBJECTIVE: The objective of the study was to describe the assessment of lower segment uterine scar (LSCS) by transvaginal ultrasound (TVUS) during a first-trimester scan. STUDY DESIGN: Patients with a history of LSCS were prospectively enrolled over a 6 month period. Four groups were defined: type 1A, thin scar within cervicoisthmic canal (CIC); type 1B, thin above the internal os (IO); type 2A, dehiscent within the CIC; type 2B, dehiscent above the IO. Accuracy of first-trimester TVUS was investigated by blind testing a panel of 14 operators over a web-based dataset. RESULTS: The scar was visualized in 122 of 123 patients enrolled. Types 1A, 1B, 2A, and 2B occurred in 49.2%, 3.3%, 38.3%, and 9.2%, respectively. When blind tested, fetal medicine specialists achieved a median sensitivity of 82% and specificity of 100% for the detection of a scar. These were 83% and 87% for nonspecialists. CONCLUSION: First-trimester uterine scar assessment may become a valuable tool in early recognition of patients at risk of subsequent perinatal complications.


Assuntos
Cicatriz/diagnóstico por imagem , Primeiro Trimestre da Gravidez , Ultrassonografia Pré-Natal/métodos , Doenças Uterinas/diagnóstico por imagem , Útero/diagnóstico por imagem , Adulto , Cesárea/estatística & dados numéricos , Cicatriz/epidemiologia , Diagnóstico Precoce , Feminino , Humanos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia Pré-Natal/normas , Doenças Uterinas/epidemiologia , Vagina
19.
Clin Oral Implants Res ; 22(12): 1420-5, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21435009

RESUMO

OBJECTIVES: Panoramic radiographs allow evaluation of the available bone height for implant treatment planning while imparting a low radiation dose. As panoramic radiography produces image distortion, reference objects are required to determine the exact magnification. This study aims to estimate a panoramic unit's vertical magnification factor (MF) by measuring the length of dental implants used as radiopaque reference objects on postoperative panoramic radiographs. We compared our findings to the vertical MF listed by the panoramic unit manufacturer, and studied the reproducibility and accuracy of our measuring method by analyzing the inter- and intraobserver agreements. MATERIAL AND METHODS: Using a digital calliper, we measured the length of 32 implants on 17 postoperative panoramic radiographs taken with a Scanora unit. The implants were 10mm-long standard Straumann implants placed in the posterior segments of mandibles. The MF was calculated by dividing the implant's radiological length by the implant's real length. RESULTS: The mean calculated vertical MF was 1.27 ± 0.01 (1.245-1.295) and was lower than the manufacturer's MF (1.3). The vertical MF was 1.28 ± 0.01 in the premolar and 1.27 ± 0.01 in the molar regions. There was an excellent intraobserver reliability (0.96 for observer 1; 0.93 for observer 2) and a good interobserver reliability (0.85 at measurement session 1; 0.8 at measurement session 2) CONCLUSIONS: The observed reliability of the MF confirms that a panoramic radiograph can be used for preoperative implant length evaluation in the posterior mandibular segments. MF stability should be verified with other panoramic units. In clinical practice, using the implant length as a reference object on postoperative panoramic radiographs is a simple and effective evaluation method to estimate a panoramic unit's MF.


Assuntos
Implantação Dentária , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Planejamento de Assistência ao Paciente , Ampliação Radiográfica/métodos , Radiografia Panorâmica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
20.
J Oral Implantol ; 37(5): 525-42, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21728785

RESUMO

Dental implants are commonly used in daily practice; however, most surgeons do not really know the characteristics of these biomedical devices they are placing in their patients. The objective of this work is to describe the chemical and morphological characteristics of 14 implant surfaces available on the market and to establish a simple and clear identification (ID) card for all of them, following the classification procedure developed in the Dohan Ehrenfest et al (2010) Codification (DEC) system. Fourteen implant surfaces were characterized: TiUnite (Nobel Biocare), Ospol (Ospol), Kohno HRPS (Sweden & Martina), Osseospeed (AstraTech), Ankylos (Dentsply Friadent), MTX (Zimmer), Promote (Camlog), BTI Interna (Biotechnology Institute), EVL Plus (SERF), Twinkon Ref (Tekka), Ossean (Intra-Lock), NanoTite (Biomet 3I), SLActive (ITI Straumann), Integra-CP/NanoTite (Bicon). Three samples of each implant were analyzed. Superficial chemical composition was analyzed using X-ray photoelectron spectroscopy/electron spectroscopy for chemical analysis, and the 100 nm in-depth profile was established using Auger electron spectroscopy. The microtopography was quantified using light interferometry. The general morphology and nanotopography were evaluated using a field emission-scanning electron microscope. Finally, the characterization code of each surface was established using the DEC system, and the main characteristics of each surface were summarized in a reader-friendly ID card. From a chemical standpoint, of the 14 different surfaces, 10 were based on a commercially pure titanium (grade 2 or 4), 3 on a titanium-aluminum alloy (grade 5 titanium), and one on a calcium phosphate core. Nine surfaces presented different forms of chemical impregnation or discontinuous coating of the titanium core, and 3 surfaces were covered with residual aluminablasting particles. Twelve surfaces presented different degrees of inorganic pollutions, and 2 presented a severe organic pollution overcoat. Only 2 surfaces presented no pollution (Osseospeed and Ossean). From a morphological standpoint, 2 surfaces were microporous (anodization) and 12 were microrough, with different microtopographical aspects and values. Ten surfaces were smooth on the nanoscale, and therefore presented no significant and repetitive nanostructures. Four implants were nanomodified: 2 implants were nanorough (Osseospeed and Ossean), and 2 were covered with nanoparticles (NanoTite and SLActive). TiUnite and Kohno HRPS were covered with extended cracks all over the surface. Only 8 surfaces could be considered homogeneous. This systematic approach allowed the main characteristics of these commercially available products to be gathered in a single ID card. It can be used as an experimental tool or a method for controlling industrial implant productions. The DEC system could be an interesting basis for the development of a clear and simple ISO standard for dental implant surfaces and other implantable devices.


Assuntos
Materiais Revestidos Biocompatíveis/química , Implantes Dentários , Planejamento de Prótese Dentária , Ligas/análise , Fosfatos de Cálcio/análise , Codificação Clínica/métodos , Ligas Dentárias/química , Controle de Formulários e Registros , Microquímica/métodos , Microscopia Eletrônica de Varredura/métodos , Nanopartículas/análise , Espectroscopia Fotoeletrônica , Porosidade , Propriedades de Superfície , Titânio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA