Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Spartan Med Res J ; 4(2): 11639, 2020 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-33655169

RESUMO

CONTEXT: Since the 1980s, the use of ultrasonography for suspected acute pediatric appendicitis has become increasingly common. Multiple studies have suggested that ultrasound of the appendix has consistently high sensitivity and specificity when the appendix can be clearly visualized. The authors' primary objective for this study was to retrospectively evaluate their community-based healthcare system's processes for detecting acute pediatric appendicitis using ultrasonography. METHODS: This was a retrospective medical chart review study of data over a five-year 2014-2018 period at Mercy Health Muskegon in Muskegon, Michigan. All patients aged 3-18 years who had received an appendix ultrasound during this period were identified using the McKesson Radiology (MS) PACS-Lite computer program. Pediatric appendix ultrasound cases were collected and analyzed for sensitivity, specificity, positive predictive value, negative predictive value with 95% confidence intervals. Acute appendicitis cases had been confirmed based on pathology reports. Secondary measures including white blood cell, body mass index, and body temperature were also included in analyses. RESULTS: In this sample, the overall sensitivity at detecting acute pediatric appendicitis using ultrasonography was relatively low at approximately 42% (95% CI: 21.1 - 66.0%). On the other hand, sample specificity was quite high at 97% (95% CI: 89.9 - 99.5%). The overall positive predictive value (PPV) was 80% (95% CI: 44.2-96.5%) and the negative predictive Value (NPV) was 86% (95% CI: 75.7-92.4%). The occurrence for false positives was 20% (95% CI: 3.5-55.8%). False negatives were 14% (95% CI: 7.6-24.3%). CONCLUSIONS: The use of ultrasonography at the authors' institution less often accurately identified cases of later-confirmed pediatric appendicitis compared to some earlier published studies. The authors concluded that this could be due to seeing a lower number of more complex/ambiguous cases of pediatric appendicitis or lack of hospital personnel's pediatric-specific training and/or experience compared to specialty children's hospitals. It is possible that imaging improvements could be achieved by either or a combination of: offering training sessions for general ultrasound technicians, offering training session for radiologists, and visiting pediatric physicians and ultrasound technicians. A valuable follow-up study would be to track anticipated improvements and lead to formulation of an acute pediatric appendicitis care protocol within the authors' healthcare system.

2.
Crit Ultrasound J ; 10(1): 10, 2018 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-29797105

RESUMO

BACKGROUND: This study aims to compare the increased time needed to perform advanced focused cardiac measurements in the emergency department, including diastolic heart failure evaluation via E/E', and cardiac output with LVOT/VTI. Patients with pertinent cardiopulmonary symptoms in the emergency department had a focused cardiac ultrasound performed by the emergency department ultrasound team. The ability to obtain basic cardiac windows, evaluate for effusion, systolic ejection fraction, and right-sided heart pressures were recorded. Advanced measurements, along with time to obtain all images and the training level of the provider, were recorded. RESULTS: Fifty-three patients were enrolled. Basic focused cardiac windows were able to be obtained in 80% of patients. The average 4-window focused cardiac ultrasound took 4 min and 49 s to perform. Diastolic measurements were able to be obtained in 51% of patients, taking an average of 3 min and 17 s. Cardiac output measurements were able to be obtained in 53% of patients, taking an average of 3 min and 8 s. CONCLUSION: The ability to obtain these images improved with increasing level of training. Performing both cardiac output and diastolic measurements increased the time with bedside ultrasound by 6 min and 25 s, and were able to be obtained in slightly over half of all ED patients.

3.
Crit Ultrasound J ; 10(1): 20, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-30109460
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA