Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Circulation ; 143(15): 1484-1498, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33472397

RESUMO

BACKGROUND: Right heart catheterization using exercise stress is the reference standard for the diagnosis of heart failure with preserved ejection fraction (HFpEF) but carries the risk of the invasive procedure. We hypothesized that real-time cardiac magnetic resonance (RT-CMR) exercise imaging with pathophysiologic data at excellent temporal and spatial resolution may represent a contemporary noninvasive alternative for diagnosing HFpEF. METHODS: The HFpEF-Stress trial (CMR Exercise Stress Testing in HFpEF; URL: https://www.clinicaltrials.gov; Unique identifier: NCT03260621. URL: https://dzhk.de/; Unique identifier: DZHK-17) prospectively recruited 75 patients with echocardiographic signs of diastolic dysfunction and dyspnea on exertion (E/e'>8, New York Heart Association class ≥II) to undergo echocardiography, right heart catheterization, and RT-CMR at rest and during exercise stress. HFpEF was defined according to pulmonary capillary wedge pressure (≥15 mm Hg at rest or ≥25 mm Hg during exercise stress). RT-CMR functional assessments included time-volume curves for total and early (1/3) diastolic left ventricular filling, left atrial (LA) emptying, and left ventricular/LA long axis strain. RESULTS: Patients with HFpEF (n=34; median pulmonary capillary wedge pressure at rest, 13 mm Hg; at stress, 27 mm Hg) had higher E/e' (12.5 versus 9.15), NT-proBNP (N-terminal pro-B-type natriuretic peptide; 255 versus 75 ng/L), and LA volume index (43.8 versus 36.2 mL/m2) compared with patients with noncardiac dyspnea (n=34; rest, 8 mm Hg; stress, 18 mm Hg; P≤0.001 for all). Seven patients were excluded because of the presence of non-HFpEF cardiac disease causing dyspnea on imaging. There were no differences in RT-CMR left ventricular total and early diastolic filling at rest and during exercise stress (P≥0.164) between patients with HFpEF and noncardiac dyspnea. RT-CMR revealed significantly impaired LA total and early (P<0.001) diastolic emptying in patients with HFpEF during exercise stress. RT-CMR exercise stress LA long axis strain was independently associated with HFpEF (adjusted odds ratio, 0.657 [95% CI, 0.516-0.838]; P=0.001) after adjustment for clinical and imaging measures and emerged as the best predictor for HFpEF (area under the curve at rest 0.82 versus exercise stress 0.93; P=0.029). CONCLUSIONS: RT-CMR allows highly accurate identification of HFpEF during physiologic exercise and qualifies as a suitable noninvasive diagnostic alternative. These results will need to be confirmed in multicenter prospective research studies to establish widespread routine clinical use. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03260621. URL: https://dzhk.de/; Unique identifier: DZHK-17.


Assuntos
Teste de Esforço/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico , Imageamento por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Cardiovasc Magn Reson ; 23(1): 60, 2021 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-34001175

RESUMO

BACKGROUND: Myocardial deformation analyses using cardiovascular magnetic resonance (CMR) feature tracking (CMR-FT) have incremental value in the assessment of cardiac function beyond volumetric analyses. Since guidelines do not recommend specific imaging parameters, we aimed to define optimal spatial and temporal resolutions for CMR cine images to enable reliable post-processing. METHODS: Intra- and inter-observer reproducibility was assessed in 12 healthy subjects and 9 heart failure (HF) patients. Cine images were acquired with different temporal (20, 30, 40 and 50 frames/cardiac cycle) and spatial resolutions (high in-plane 1.5 × 1.5 mm through-plane 5 mm, standard 1.8 × 1.8 x 8mm and low 3.0 × 3.0 x 10mm). CMR-FT comprised left ventricular (LV) global and segmental longitudinal/circumferential strain (GLS/GCS) and associated systolic strain rates (SR), and right ventricular (RV) GLS. RESULTS: Temporal but not spatial resolution did impact absolute strain and SR. Maximum absolute changes between lowest and highest temporal resolution were as follows: 1.8% and 0.3%/s for LV GLS and SR, 2.5% and 0.6%/s for GCS and SR as well as 1.4% for RV GLS. Changes of strain values occurred comparing 20 and 30 frames/cardiac cycle including LV and RV GLS and GCS (p < 0.001-0.046). In contrast, SR values (LV GLS/GCS SR) changed significantly comparing all successive temporal resolutions (p < 0.001-0.013). LV strain and SR reproducibility was not affected by either temporal or spatial resolution, whilst RV strain variability decreased with augmentation of temporal resolution. CONCLUSION: Temporal but not spatial resolution significantly affects strain and SR in CMR-FT deformation analyses. Strain analyses require lower temporal resolution and 30 frames/cardiac cycle offer consistent strain assessments, whilst SR measurements gain from further increases in temporal resolution.


Assuntos
Ventrículos do Coração , Imagem Cinética por Ressonância Magnética , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Função Ventricular Esquerda
3.
Sci Rep ; 11(1): 11648, 2021 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-34078942

RESUMO

Cardiovascular magnetic resonance (CMR) imaging provides reliable assessments of biventricular morphology and function. Since manual post-processing is time-consuming and prone to observer variability, efforts have been directed towards novel artificial intelligence-based fully automated analyses. Hence, we sought to investigate the impact of artificial intelligence-based fully automated assessments on the inter-study variability of biventricular volumes and function. Eighteen participants (11 with normal, 3 with heart failure and preserved and 4 with reduced ejection fraction (EF)) underwent serial CMR imaging at in median 63 days (range 49-87) interval. Short axis cine stacks were acquired for the evaluation of left ventricular (LV) mass, LV and right ventricular (RV) end-diastolic, end-systolic and stroke volumes as well as EF. Assessments were performed manually (QMass, Medis Medical Imaging Systems, Leiden, Netherlands) by an experienced (3 years) and inexperienced reader (no active reporting, 45 min of training with five cases from the SCMR consensus data) as well as fully automated (suiteHEART, Neosoft, Pewaukee, WI, USA) without any manual corrections. Inter-study reproducibility was overall excellent with respect to LV volumetric indices, best for the experienced observer (intraclass correlation coefficient (ICC) > 0.98, coefficient of variation (CoV, < 9.6%) closely followed by automated analyses (ICC > 0.93, CoV < 12.4%) and lowest for the inexperienced observer (ICC > 0.86, CoV < 18.8%). Inter-study reproducibility of RV volumes was excellent for the experienced observer (ICC > 0.88, CoV < 10.7%) but considerably lower for automated and inexperienced manual analyses (ICC > 0.69 and > 0.46, CoV < 22.8% and < 28.7% respectively). In this cohort, fully automated analyses allowed reliable serial investigations of LV volumes with comparable inter-study reproducibility to manual analyses performed by an experienced CMR observer. In contrast, RV automated quantification with current algorithms still relied on manual post-processing for reliability.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Algoritmos , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia
4.
PLoS One ; 14(1): e0210127, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30682045

RESUMO

BACKGROUND: Cardiovascular magnetic resonance feature tracking (CMR-FT) is increasingly used for myocardial deformation assessment including ventricular strain, showing prognostic value beyond established risk markers if used in experienced centres. Little is known about the impact of appropriate training on CMR-FT performance. Consequently, this study aimed to evaluate the impact of training on observer variance using different commercially available CMR-FT software. METHODS: Intra- and inter-observer reproducibility was assessed prior to and after dedicated one-hour observer training. Employed FT software included 3 different commercially available platforms (TomTec, Medis, Circle). Left (LV) and right (RV) ventricular global longitudinal as well as LV circumferential and radial strains (GLS, GCS and GRS) were studied in 12 heart failure patients and 12 healthy volunteers. RESULTS: Training improved intra- and inter-observer reproducibility. GCS and LV GLS showed the highest reproducibility before (ICC >0.86 and >0.81) and after training (ICC >0.91 and >0.92). RV GLS and GRS were more susceptible to tracking inaccuracies and reproducibility was lower. Inter-observer reproducibility was lower than intra-observer reproducibility prior to training with more pronounced improvements after training. Before training, LV strain reproducibility was lower in healthy volunteers as compared to patients with no differences after training. Whilst LV strain reproducibility was sufficient within individual software solutions inter-software comparisons revealed considerable software related variance. CONCLUSION: Observer experience is an important source of variance in CMR-FT derived strain assessment. Dedicated observer training significantly improves reproducibility with most profound benefits in states of high myocardial contractility and potential to facilitate widespread clinical implementation due to optimized robustness and diagnostic performance.


Assuntos
Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular/diagnóstico , Adulto , Idoso , Feminino , Voluntários Saudáveis , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Software , Disfunção Ventricular/complicações , Disfunção Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA