Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 155(3): 2025-2036, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38470185

RESUMO

Quantitative, accurate, and standardized metrics are important for reliable shear wave elastography (SWE)-based biomarkers. For over two decades, the linear-elastic material assumption has been employed in SWE modes. In recent years, viscoelasticity estimation methods have been adopted in a few clinical systems. The current study aims to systematically quantify differences in SWE estimates obtained using linear-elastic and viscoelastic material assumptions. An acousto-mechanical simulation framework of acoustic radiation force impulse-based SWE was created to elucidate the effect of material viscosity and shear modulus on SWE estimates. Shear modulus estimates exhibited errors up to 72% when a numerical viscoelastic phantom was assessed as linearly elastic. Shear modulus estimates of polyvinyl alcohol phantoms between rheometry and SWE following the Kelvin-Voigt viscoelastic model assumptions were not significantly different. However, the percentage difference in shear modulus estimates between rheometry and SWE using the linear-elastic assumption was 50.1%-62.1%. In ex vivo liver, the percentage difference in shear modulus estimates between linear-elastic and viscoelastic methods was 76.1%. These findings provide a direct and systematic quantification of the potential error introduced when viscoelastic tissues are imaged with SWE following the linear-elastic assumption. This work emphasizes the need to utilize viscoelasticity estimation methods for developing robust quantitative imaging biomarkers.


Assuntos
Técnicas de Imagem por Elasticidade , Simulação por Computador , Fígado , Imagens de Fantasmas , Biomarcadores
2.
ACS Omega ; 9(7): 8352-8361, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38405437

RESUMO

Ultrasound elastography enables noninvasive characterization of the tissue mechanical properties. Phantoms are widely used in ultrasound elastography for developing, testing, and validating imaging techniques. Creating phantoms with a range of viscoelastic properties relevant to human organs and pathological conditions remains an active area of research. Poly(vinyl alcohol) (PVA) cryogel phantoms offer a long shelf life, robustness, and convenient handling and storage. The goal of this study was to develop tunable phantoms using PVA with a clinically relevant range of viscoelastic properties. We combined low- and high-viscosity PVA to tune the viscoelastic properties of the phantom. Further, phantoms were created with an ethylene glycol-based cryoprotectant to determine whether it reduces the variability in the viscoelastic properties. Scanning electron microscopy (SEM) was performed to evaluate the differences in microstructure between phantoms. The density, longitudinal sound speed, and acoustic attenuation spectra (5-20 MHz) of the phantoms were measured. The phantoms were characterized using a shear wave viscoelastography approach assuming the Kelvin-Voigt model. Microstructural differences were revealed by SEM between phantoms with and without a cryoprotectant and with different PVA mixtures. The longitudinal sound speed and attenuation power-law fit exponent of the phantoms were within the clinical range (1510-1571 m/s and 1.23-1.38, respectively). The measured shear modulus (G) ranged from 3.3 to 17.7 kPa, and the viscosity (η) ranged from 2.6 to 7.3 Pa·s. The phantoms with the cryoprotectant were more homogeneous and had lower shear modulus and viscosity (G = 2.17 ± 0.2 kPa; η = 2.0 ± 0.05 Pa·s) than those without a cryoprotectant (G = 3.93 ± 0.7 kPa; η = 2.6 ± 0.14 Pa·s). Notably, phantoms with relatively constant viscosities and varying shear moduli were achieved by this method. These findings advance the development of well-characterized viscoelastic phantoms for use in elastography.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA