Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Plant Biotechnol J ; 14(4): 1139-50, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26427614

RESUMO

Coeliac disease is a well-defined condition that is estimated to affect approximately 1% of the population worldwide. Noncoeliac gluten sensitivity is a condition that is less well defined, but is estimated to affect up to 10% of the population, and is often self-diagnosed. At present, the only remedy for both conditions is a lifelong gluten-free diet. A gluten-free diet is often expensive, high in fat and low in fibre, which in themselves can lead to adverse health outcomes. Thus, there is an opportunity to use novel plant breeding strategies to develop alternative gluten-free grains. In this work, we describe the breeding and characterization of a novel ultra-low gluten (ULG) barley variety in which the hordein (gluten) content was reduced to below 5 ppm. This was achieved using traditional breeding strategies to combine three recessive alleles, which act independently of each other to lower the hordein content in the parental varieties. The grain of the initial variety was shrunken compared to wild-type barleys. We implemented a breeding strategy to improve the grain size to near wild-type levels and demonstrated that the grains can be malted and brewed successfully. The ULG barley has the potential to provide novel healthy foods and beverages for those who require a gluten-free diet.


Assuntos
Farinha/análise , Glutens/genética , Hordeum/genética , Acrilamida/química , Aminoácidos/análise , Amilases/metabolismo , Doença Celíaca , Dieta Livre de Glúten , Ensaio de Imunoadsorção Enzimática , Glutens/análise , Glutens/metabolismo , Hordeum/fisiologia , Humanos , Espectrometria de Massas/métodos , Melhoramento Vegetal/métodos , Sementes/fisiologia
2.
J Agric Food Chem ; 68(20): 5763-5775, 2020 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-32374605

RESUMO

Hordeins are the major barley seed storage proteins and are elicitors of celiac disease. Attempts to reduce the hordein level in barley have been made; however, the resultant pleiotropic effects are less understood. Here, data-independent acquisition mass spectrometry was used to measure proteome-wide abundance differences between wild-type and single hordein-null barley lines. Using comparative quantitative proteomics, we detected proteome-wide changes (∼59%) as a result of the specific reduction in hordein proteins. The comparative analysis and functional annotation revealed an increase in non-gluten storage proteins, such as globulins and lipid transfer proteins, and proteins rich in essential amino acids in the null lines. This study yields an informative molecular portrait of the hordein-null lines and the underlying mechanisms of storage protein biosynthesis. This study indicates the extent to which protein content can be manipulated without biological consequence, and we envision its wide-scale application for studying modified crops.


Assuntos
Glutens/genética , Hordeum/química , Proteínas de Plantas/metabolismo , Plantas Geneticamente Modificadas/química , Proteoma/metabolismo , Antígenos de Plantas/análise , Antígenos de Plantas/genética , Antígenos de Plantas/metabolismo , Proteínas de Transporte/análise , Proteínas de Transporte/genética , Proteínas de Transporte/metabolismo , Técnicas de Inativação de Genes , Globulinas/análise , Globulinas/genética , Globulinas/metabolismo , Glutens/química , Glutens/metabolismo , Hordeum/genética , Hordeum/metabolismo , Espectrometria de Massas , Proteínas de Plantas/análise , Proteínas de Plantas/genética , Plantas Geneticamente Modificadas/genética , Plantas Geneticamente Modificadas/metabolismo , Proteoma/química , Proteoma/genética , Proteômica
3.
Front Plant Sci ; 10: 649, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31156692

RESUMO

The temporal pattern of accumulation of hordein storage proteins in developing barley grains was studied by enzyme-linked immunosorbent assay (ELISA), western blot and liquid chromatography tandem mass spectrometry (LC-MS/MS). Hordein accumulation was compared to the pattern seen for two abundant control proteins, serpin Z4 (an early accumulator) and lipid transferase protein (LTP1, a late accumulator). Hordeins were detected from 6 days post-anthesis (DPA) and peaked at 30 DPA. Changes in fresh weight indicate that desiccation begins at 20 DPA and by 37 DPA fresh weight had decreased by 35%. ELISA analysis of hordein content, expressed on a protein basis, increased to a maximum at 30 DPA followed by a 17% decrease by 37 DPA. The accumulation of 39 tryptic and 29 chymotryptic hordein peptides representing all classes of hordein was studied by LC-MS/MS. Most peptides increased to a maximum at 30 DPA, and either remained at the maximum or did not decrease significantly. Only five tryptic peptides, members of the related B1- and γ1-hordeins decreased significantly by 21-51% at 37 DPA. Thus, the concentration of some specific peptides was reduced while remaining members of the same family were not affected. The N-terminal signal region was removed by proteolysis during co-translation. In addition to a suite of previously characterized hordeins, two novel barley B-hordein isoforms mapping to wheat low molecular weight glutenins (LMW-GS-like B-hordeins), and two avenin-like proteins (ALPs) sharing homology with wheat ALPs, were identified. These identified isoforms have not previously been mapped in the barley genome. Cereal storage proteins provide significant nutritional content for human consumption and seed germination. In barley, the bulk of the storage proteins comprise the hordein family and the final hordein concentration affects the quality of baked and brewed products. It is therefore important to study the accumulation of hordeins as this knowledge may assist plant breeding for improved health outcomes (by minimizing triggering of detrimental immune responses), nutrition and food processing properties.

4.
PLoS One ; 8(2): e56452, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23509606

RESUMO

BACKGROUND: Subjects suffering from coeliac disease, gluten allergy/intolerance must adopt a lifelong avoidance of gluten. Beer contains trace levels of hordeins (gluten) which are too high to be safely consumed by most coeliacs. Accurate measurement of trace hordeins by ELISA is problematic. METHODS: We have compared hordein levels in sixty beers, by sandwich ELISA, with the level determined using multiple reaction monitoring mass spectrometry (MRM-MS). RESULTS: Hordein levels measured by ELISA varied by four orders of magnitude, from zero (for known gluten-free beers) to 47,000 µg/mL (ppm; for a wheat-based beer). Half the commercial gluten-free beers were free of hordein by MS and ELISA. Two gluten-free and two low-gluten beers had zero ELISA readings, but contained significant hordein levels (p<0.05), or near average (60-140%) hordein levels, by MS, respectively. Six beers gave false negatives, with zero ELISA readings but near average hordein content by MS. Approximately 20% of commercial beers had ELISA readings less than 1 ppm, but a near average hordein content by MS. Several barley beers also contained undeclared wheat proteins. CONCLUSIONS: ELISA results did not correlate with the relative content of hordein peptides determined by MS, with all barley based beers containing hordein. We suggest that mass spectrometry is more reliable than ELISA, as ELISA enumerates only the concentration of particular amino-acid epitopes; this may vary between different hordeins and may not be related to the absolute hordein concentration. MS quantification is undertaken using peptides that are specific and unique, enabling the quantification of individual hordein isoforms. This outlines the problem of relying solely on ELISA determination of gluten in beverages such as beer and highlights the need for the development of new sensitive and selective quantitative assay such as MS.


Assuntos
Cerveja/análise , Doença Celíaca/prevenção & controle , Técnicas de Química Analítica/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Glutens/análise , Espectrometria de Massas/métodos , Humanos , Corantes de Rosanilina
5.
PLoS One ; 8(2): e56456, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23509607

RESUMO

BACKGROUND: Coeliacs require a life-long gluten-free diet supported by accurate measurement of gluten (hordein) in gluten-free food. The gluten-free food industry, with a value in excess of $6 billion in 2011, currently depends on two ELISA protocols calibrated against standards that may not be representative of the sample being assayed. AIM: The factors affecting the accuracy of ELISA analysis of hordeins in beer were examined. RESULTS: A simple alcohol-dithiothreitol extraction protocol successfully extracts the majority of hordeins from barley flour and malt. Primary hordein standards were purified by FPLC. ELISA detected different classes of purified hordeins with vastly different sensitivity. The dissociation constant (Kd) for a given ELISA reaction with different hordeins varied by three orders of magnitude. The Kd of the same hordein determined by ELISA using different antibodies varied by up to two orders of magnitude. The choice of either ELISA kit or hordein standard may bias the results and confound interpretation. CONCLUSIONS: Accurate determination of hordein requires that the hordein standard used to calibrate the ELISA reaction be identical in composition to the hordeins present in the test substance. In practice it is not feasible to isolate a representative hordein standard from each test food. We suggest that mass spectrometry is more reliable than ELISA, as ELISA enumerates only the concentration of particular amino-acid epitopes which may vary between different hordeins and may not be related to the absolute hordein concentration. MS quantification is undertaken using peptides that are specific and unique enabling the quantification of individual hordein isoforms.


Assuntos
Doença Celíaca/prevenção & controle , Técnicas de Química Analítica/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Glutens/análise , Calibragem/normas , Cromatografia Líquida , Humanos , Espectrometria de Massas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA