Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Am Coll Cardiol ; 57(5): 538-45, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21272743

RESUMO

OBJECTIVES: The purpose of this randomized study was to compare sirolimus-eluting stenting with coronary artery bypass grafting (CABG) for patients with unprotected left main (ULM) coronary artery disease. BACKGROUND: CABG is considered the standard of care for treatment of ULM. Improvements in percutaneous coronary intervention (PCI) with use of drug-eluting stents might lead to similar results. The effectiveness of drug-eluting stenting versus surgery has not been established in a randomized trial. METHODS: In this prospective, multicenter, randomized trial, 201 patients with ULM disease were randomly assigned to undergo sirolimus-eluting stenting (n = 100) or CABG using predominantly arterial grafts (n = 101). The primary clinical end point was noninferiority in freedom from major adverse cardiac events, such as cardiac death, myocardial infarction, and the need for target vessel revascularization within 12 months. RESULTS: The combined primary end point was reached in 13.9% of patients after surgery, as opposed to 19.0% after PCI (p = 0.19 for noninferiority). The combined rates for death and myocardial infarction were comparable (surgery, 7.9% vs. stenting, 5.0%; noninferiority p < 0.001), but stenting was inferior to surgery for repeat revascularization (5.9% vs. 14.0%; noninferiority p = 0.35). Perioperative complications including 2 strokes were higher after surgery (4% vs. 30%; p < 0.001). Freedom from angina was similar between groups (p = 0.33). CONCLUSIONS: In patients with ULM stenosis, PCI with sirolimus-eluting stents did not show noninferiority [corrected] to CABG at 12-month follow-up with respect to freedom from major adverse cardiac events, which is mainly influenced by repeated revascularization, whereas for hard endpoints, [corrected] PCI results are favorable. A longer follow-up is warranted. [corrected]


Assuntos
Angioplastia Coronária com Balão/métodos , Ponte de Artéria Coronária/métodos , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Resultado do Tratamento
2.
Heart ; 93(3): 331-4, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16940392

RESUMO

OBJECTIVE: To define the clinical and angiographic follow-up results after implantation of paclitaxel-eluting stents (PESs) in stenotic saphenous vein grafts (SVGs). DESIGN: Prospective multicentre study. Comparison with a control group. METHODS: 60 consecutive patients with 65 lesions located in 65 SVGs (mean (SD) age of vein grafts 11.3 (5.7) years) treated with PES (V-Flex Plus, 2.7 microg/mm(2) paclitaxel, Cook) and 60 patients with 60 SVG lesions treated with bare metal stent (BMS) were included. Lesions had to be <20 mm in length and in grafts of 2.75-3.5 mm diameter. The 6 month angiographic follow-up was obtained on 51 lesions (79%) of the PES group and on 51 lesions (85%) of the BMS group. RESULTS: Baseline clinical and angiographic characteristics were comparable between both groups. At angiographic follow-up, three vein grafts in the PES group and five vein grafts in the BMS group were occluded. In-stent late lumen loss was lower in PES than in BMS (0.61 (0.81) vs 1.06 (0.72) mm, respectively; p = 0.021). In-stent binary restenosis rates were 12% vs 33%, respectively, (p = 0.012). Linear regression analysis showed BMS to be the only factor with an effect on late lumen loss (p = 0.011). Target-vessel failure rates were 18% in the PES group and 41% in the BMS group (p = 0.019), whereas major adverse cardiac event (MACE) rates at 180 days were 15% and 37%, respectively (p = 0.014). CONCLUSIONS: Implantation of non-polymer-based PES in SVG lesions is associated with a lower late lumen loss and restenosis rate than those of BMS. There remains a substantial target-vessel failure rate and MACE rate even at 6 months owing to graft occlusion or new lesions in the graft.


Assuntos
Reestenose Coronária/prevenção & controle , Oclusão de Enxerto Vascular/prevenção & controle , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Veia Safena , Idoso , Estudos de Casos e Controles , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Implantes de Medicamento , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA