Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
N Engl J Med ; 359(16): 1675-84, 2008 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-18832239

RESUMO

BACKGROUND: The sensitivity of screening mammography for the detection of small breast cancers is higher when the mammogram is read by two readers rather than by a single reader. We conducted a trial to determine whether the performance of a single reader using a computer-aided detection system would match the performance achieved by two readers. METHODS: The trial was designed as an equivalence trial, with matched-pair comparisons between the cancer-detection rates achieved by single reading with computer-aided detection and those achieved by double reading. We randomly assigned 31,057 women undergoing routine screening by film mammography at three centers in England to double reading, single reading with computer-aided detection, or both double reading and single reading with computer-aided detection, at a ratio of 1:1:28. The primary outcome measures were the proportion of cancers detected according to regimen and the recall rates within the group receiving both reading regimens. RESULTS: The proportion of cancers detected was 199 of 227 (87.7%) for double reading and 198 of 227 (87.2%) for single reading with computer-aided detection (P=0.89). The overall recall rates were 3.4% for double reading and 3.9% for single reading with computer-aided detection; the difference between the rates was small but significant (P<0.001). The estimated sensitivity, specificity, and positive predictive value for single reading with computer-aided detection were 87.2%, 96.9%, and 18.0%, respectively. The corresponding values for double reading were 87.7%, 97.4%, and 21.1%. There were no significant differences between the pathological attributes of tumors detected by single reading with computer-aided detection alone and those of tumors detected by double reading alone. CONCLUSIONS: Single reading with computer-aided detection could be an alternative to double reading and could improve the rate of detection of cancer from screening mammograms read by a single reader. (ClinicalTrials.gov number, NCT00450359.)


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Idoso , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radiologia , Sensibilidade e Especificidade
2.
Radiology ; 256(2): 379-86, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20656831

RESUMO

PURPOSE: To evaluate the mammographic features of breast cancer that favor lesion detection with single reading and computer-aided detection (CAD) or with double reading. MATERIALS AND METHODS: The Computer Aided Detection Evaluation Trial II study was approved by the ethics committee, and all participants provided written informed consent. A total of 31,057 women were recruited from three screening centers between September 2006 and August 2007. They were randomly allocated to the double reading group, the single reading with CAD group, or the double reading and single reading with CAD group at a ratio of 1:1:28, respectively. In this study, cancers in the women whose mammograms were read with both single reading with CAD and double reading were retrospectively reviewed. The original mammograms were obtained for each case and reviewed by two of three experienced breast radiologists in consensus. The method of detection was noted. The size and predominant mammographic feature of the cancer were recorded, as was the breast density. CAD marking data were reviewed to determine if the cancer had been correctly marked. RESULTS: A total of 227 cancers were detected in 28,204 women. A total of 170 cases were recalled with both reading regimens. Lesion types were masses (66%), microcalcifications (25%), parenchymal deformities (6%), and asymmetric densities (3%). The ability of the reading regimens to correctly prompt the reader to recall cases varied significantly by lesion type (P < .001). More parenchymal deformities were recalled with double reading, whereas more asymmetric densities were recalled with single reading with CAD. There was no difference in the ability of either reading regimen to prompt the reader to correctly recall masses or microcalcifications. CAD correctly prompted 100% of microcalcifications, 87% of mass lesions, 80% of asymmetric densities, and 50% of parenchymal deformities. CAD correctly marked 93% of spiculated masses compared with 80% of ill-defined masses (P = .054). There was a significant trend for cancers detected with double reading to occur only in women with a denser mammographic background pattern (P = .02). Size had no effect on lesion detection. CONCLUSION: Readers using either single reading with CAD or double reading need to be aware of the strengths and weaknesses of reading regimens to avoid missing the more challenging cancer cases.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Mamografia/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Inglaterra/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
3.
Breast Cancer Res ; 11(6): R80, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19903338

RESUMO

INTRODUCTION: Mammographic breast density is one of the strongest known risk factors for breast cancer. We present a novel technique for estimating breast density based on 3D T1-weighted Magnetic Resonance Imaging (MRI) and evaluate its performance, including for breast cancer risk prediction, relative to two standard mammographic density-estimation methods. METHODS: The analyses were based on MRI (n = 655) and mammography (n = 607) images obtained in the course of the UK multicentre magnetic resonance imaging breast screening (MARIBS) study of asymptomatic women aged 31 to 49 years who were at high genetic risk of breast cancer. The MRI percent and absolute dense volumes were estimated using our novel algorithm (MRIBview) while mammographic percent and absolute dense area were estimated using the Cumulus thresholding algorithm and also using a 21-point Visual Assessment scale for one medio-lateral oblique image per woman. We assessed the relationships of the MRI and mammographic measures to one another, to standard anthropometric and hormonal factors, to BRCA1/2 genetic status, and to breast cancer risk (60 cases) using linear and Poisson regression. RESULTS: MRI percent dense volume is well correlated with mammographic percent dense area (R = 0.76) but overall gives estimates 8.1 percentage points lower (P < 0.0001). Both show strong associations with established anthropometric and hormonal factors. Mammographic percent dense area, and to a lesser extent MRI percent dense volume were lower in BRCA1 carriers (P = 0.001, P = 0.010 respectively) but there was no association with BRCA2 carrier status. The study was underpowered to detect expected associations between percent density and breast cancer, but women with absolute MRI dense volume in the upper half of the distribution had double the risk of those in the lower half (P = 0.009). CONCLUSIONS: The MRIBview estimates of volumetric breast density are highly correlated with mammographic dense area but are not equivalent measures; the MRI absolute dense volume shows potential as a predictor of breast cancer risk that merits further investigation.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Mama/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Neoplasias da Mama/patologia , Estudos de Coortes , Feminino , Genes BRCA1 , Genes BRCA2 , Genes p53 , Predisposição Genética para Doença , Mutação em Linhagem Germinativa , Humanos , Mamografia , Pessoa de Meia-Idade
4.
Breast Cancer Res ; 10(4): R64, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18651965

RESUMO

INTRODUCTION: Mammographic density is known to be a strong risk factor for breast cancer. A particularly strong association with risk has been observed when density is measured using interactive threshold software. This, however, is a labour-intensive process for large-scale studies. METHODS: Our aim was to determine the performance of visually assessed percent breast density as an indicator of breast cancer risk. We compared the effect on risk of density as measured with the mediolateral oblique view only versus that estimated as the average density from the mediolateral oblique view and the craniocaudal view. Density was assessed using a visual analogue scale in 10,048 screening mammograms, including 311 breast cancer cases diagnosed at that screening episode or within the following 6 years. RESULTS: Where only the mediolateral oblique view was available, there was a modest effect of breast density on risk with an odds ratio for the 76% to 100% density relative to 0% to 25% of 1.51 (95% confidence interval 0.71 to 3.18). When two views were available, there was a considerably stronger association, with the corresponding odds ratio being 6.77 (95% confidence interval 2.75 to 16.67). CONCLUSION: This indicates that a substantial amount of information on risk from percentage breast density is contained in the second view. It also suggests that visually assessed breast density has predictive potential for breast cancer risk comparable to that of density measured using the interactive threshold software when two views are available. This observation needs to be confirmed by studies applying the different measurement methods to the same individuals.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Mama/patologia , Mamografia/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Programas de Rastreamento/métodos , Razão de Chances , Reprodutibilidade dos Testes , Risco , Medição de Risco/métodos , Fatores de Risco , Software
5.
Cancer Epidemiol Biomarkers Prev ; 17(9): 2268-74, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18768492

RESUMO

PURPOSE: A method and computer tool to estimate percentage magnetic resonance (MR) imaging (MRI) breast density using three-dimensional T(1)-weighted MRI is introduced, and compared with mammographic percentage density [X-ray mammography (XRM)]. MATERIALS AND METHODS: Ethical approval and informed consent were obtained. A method to assess MRI breast density as percentage volume occupied by water-containing tissue on three-dimensional T(1)-weighted MR images is described and applied in a pilot study to 138 subjects who were imaged by both MRI and XRM during the Magnetic Resonance Imaging in Breast Screening study. For comparison, percentage mammographic density was measured from matching XRMs as a ratio of dense to total projection areas scored visually using a 21-point score and measured by applying a two-dimensional interactive program (CUMULUS). The MRI and XRM percent methods were compared, including assessment of left-right and interreader consistency. RESULTS: Percent MRI density correlated strongly (r = 0.78; P < 0.0001) with percent mammographic density estimated using Cumulus. Comparison with visual assessment also showed a strong correlation. The mammographic methods overestimate density compared with MRI volumetric assessment by a factor approaching 2. DISCUSSION: MRI provides direct three-dimensional measurement of the proportion of water-based tissue in the breast. It correlates well with visual and computerized percent mammographic density measurements. This method may have direct application in women having breast cancer screening by breast MRI and may aid in determination of risk.


Assuntos
Neoplasias da Mama/patologia , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Adulto , Composição Corporal , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Mamografia , Pessoa de Meia-Idade , Projetos Piloto
6.
IEEE Trans Med Imaging ; 23(9): 1077-86, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15377116

RESUMO

We describe methods for detecting linear structures in mammograms, and for classifying them into anatomical types (vessels, spicules, ducts, etc). Several different detection methods are compared, using realistic synthetic images and receiver operating characteristic (ROC) analysis. There are significant differences (p < 0.001) between the methods, with the best giving an Az value for pixel-level detection of 0.943. We also investigate methods for classifying the detected linear structures into anatomical types, using their cross-sectional profiles, with particular emphasis on recognising the "spicules" and "ducts" associated with some of the more subtle abnormalities. Automatic classification results are compared with expert annotations using ROC analysis, demonstrating useful discrimination between anatomical classes (Az = 0.746). Some of this discrimination relies on simple attributes such as profile width and contrast, but important information is also carried by the shape of the profile (Az = 0.653). The methods presented have potentially wide application in improving the specificity of abnormality detection by exploiting additional anatomical information.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Mamografia/métodos , Reconhecimento Automatizado de Padrão , Doenças Mamárias/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Med Screen ; 16(4): 180-5, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20054092

RESUMO

OBJECTIVES: Multicentre randomized trials frequently encounter difficulties in meeting their recruitment targets, resulting in extension of the trial and delays in implementation of the findings. We report on recruitment strategies implemented in a randomized evaluation of computer-aided detection in women attending routine screening in the UK Breast Screening Programme. SETTING: The target population for the trial was identified from an existing NHS database of women aged 50-70 invited for routine mammography in Coventry, Manchester and Nottingham, UK. Women were asked to consent to their mammograms being randomly allocated (in a ratio of 28:1:1) to one of three film-reading protocols. Trial information was mailed to women, along with the invitation to attend screening, and informed consent was obtained at the mammography appointment. Several strategies were implemented to increase recruitment rates. RESULTS: Recruitment rate increased significantly over time in the study (P < 0.0010 in all centres) with an overall acceptance rate of 46% of those attending screening. Mailing of the trial information sheet separate from the screening invitation in Coventry and Nottingham increased the recruitment rate, even after adjustment for the trend over time and for socioeconomic status of the attendees (P < 0.001). Extension of recruitment to mobile screening units in Nottingham, and the presence of an additional member of staff also improved recruitment (P < 0.001). Simplification of the trial information sheet had little effect. Increases in recruitment rate were not attributable to socioeconomic status of the attendees. CONCLUSIONS: In multicentre trials, monitoring of local recruitment protocols is required to ensure that each centre can maximize accrual targets.


Assuntos
Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Idoso , Comportamento Cooperativo , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Seleção de Pacientes
8.
Radiology ; 241(1): 47-53, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16990670

RESUMO

PURPOSE: To retrospectively determine if the use of a computer-aided detection (CAD) system can improve the performance of single reading of screening mammograms to match that of double reading in the United Kingdom. MATERIALS AND METHODS: Local research ethics committee approval was obtained; informed consent was not required. This study included a sample of 10 267 mammograms obtained in women aged 50 years or older who underwent routine screening at one of two breast screening centers in 1996. Mammograms that were double read in 1996 were randomly allocated to be re-read by eight different radiologists using CAD. The cancer detection and recall rates from double reading and single reading with CAD were compared. Statistical significance and confidence intervals were calculated with the McNemar test to account for the matched nature of the data. RESULTS: Single reading with CAD led to a cancer detection rate that was significantly (P = .02) higher than that achieved with double reading: 6.5% more cancers were detected by means of single reading with CAD than by means of double reading. However, the recall rate was higher for single reading with CAD than for double reading (8.6% vs 6.5%, respectively; P < .001). This was equivalent to relative increases of 15% and 32% in the cancer detection and recall rates, respectively. CONCLUSION: Single reading with CAD leads to an improved cancer detection rate and an increased recall rate.


Assuntos
Processamento de Imagem Assistida por Computador , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Programas Governamentais , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA