Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 260(4): 1377-1386, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34655333

RESUMO

PURPOSE: To evaluate residual astigmatism following correction with toric implantable collamer lens (TICL) (group I) over a period of 4 years and compare with the change of astigmatism in spectacle wearers (group II). METHODS: Groups I (86 cases implanted with TICL [EVO + Visian ICL, Staar Surgical, Nidau, Switzeland], preop refractive error [sphere and cylinder] - 22.25 DS to - 1.00 DS and - 5.50 DC to - 1.00 DC) and II (80 cases initial refractive error [sphere and cylinder] - 18.00 DS to 0.00 DS and - 7.00 DC to - 1.00 DC) were reviewed annually. Refractive and tomography data were subjected to vector analysis to determine surgically induced astigmatism (SIA), angle of error [Δθ° = angle of target-induced astigmatism (TIA) - angle of SIA], and ΔC [TIA-SIA powers] and total corneal astigmatism (TCA) in group I and induced change in astigmatism (ICA) in group II. RESULTS: In group I, on all occasions, SIA correlated with TIA (p < 0.05); differences between SIA and TIA means were insignificant and changes in TCA were not correlated with ΔC. Mean (± sd, 95% CI) residual astigmatic powers (RA) in attending group I cases (1-4 years) were - 0.40 DC (0.58, - 0.52 to - 0.28), - 0.40 DC (0.59, - 0.52 to - 0.27), - 0.41 DC (0.58, - 0.54 to - 0.28), and - 0.61 DC (0.74, - 0.82 to - 0.40). In group II, the corresponding ICA powers were - 0.47 DC (0.53, - 0.61 to - 0.32), - 0.49 DC (0.48, - 0.69 to - 0.29), - 0.60 DC (0.40, - 0.76 to - 0.44), and - 0.86 DC (0.71, - 1.19 to - 0.52). Differences between RA and ICA were not significant. Of the group I cases presenting at 1-4 years postop, 23, 18, 16, and 28 had RA powers ≤ - 0.75 DC. Of these 12, 10, 6, and 16 were associated with Δθ° > 5° (ΔC - 0.50 to 0 DC) and 5, 1, 4, and 4 were related to ΔC (Δθ° < 5°). CONCLUSION: The development of astigmatism after TICL implantation is on par with the natural change in astigmatism in untreated cases. In about 50% of TICL cases presenting with astigmatism ≤ - 0.75 DC, the residual astigmatism could be neutralized by realigning the TICL.


Assuntos
Astigmatismo , Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Erros de Refração , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Progressão da Doença , Óculos , Humanos , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares Fácicas/efeitos adversos , Refração Ocular
2.
Int Ophthalmol ; 42(10): 3191-3198, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35538254

RESUMO

PURPOSE: To determine the prevalence of keratoconus (KC) in relation to ethnicity in a group of people who consulted an ophthalmological care institution seeking for refractive surgery in N. Macedonia. METHODS: This was a cross-sectional, interventional retrospective study. Chart reviews were performed for all new patients attending between January 2016 and January 2020 at the Sistina Ophthalmology Hospital in Skopje. All patients were screened; KC diagnosis and classification were based on the corneal topography. Ethnicity and gender classifications were according to patients' self-opinions. RESULTS: A total of 2812 patients charts reviewed. The mean age was 31.71 years (SD ± 9.73), and 1209 (43%) were male. A total of 2050 (72.9%) declared themselves as Macedonians, 649 (23.1%) Albanians, 76 (2.7%) Turks and 37 (1.3%) in other ethnicities. Differences in age between the ethnic groups were statistically significant (x2 = 90.225, p < 0.001). KC was diagnosed in 343 patients (12.2%), while 9 (0.7%) were KC suspects and 6(0.21%) presented pellucid marginal degeneration. KC was more frequent in males (n = 246, 71.7% of total) and skewed toward younger patients. Increasing patients' age decreased the odds of KC diagnosis by 3.7% (95% CI 1.8%-4.4%) per annum. Males were four times more likely to be diagnosed with KC (AOR = 4.01; 95% CI 3.12-5.16). In comparison with Macedonian patients, Turks were more likely to be diagnosed with KC (AOR = 4.09; 95% CI 2.47-6.78). There was no difference between Macedonians and Albanians (p = 0.08). CONCLUSION: The prevalence of KC at a refractive surgery practice in N. Macedonia is much higher compared with general population (6.8/100,000) and similar to the prevalence in Middle East Asia. Nationwide screening programs are needed to diagnose the disease earlier.


Assuntos
Ceratocone , Oftalmologia , Procedimentos Cirúrgicos Refrativos , Adulto , Córnea , Topografia da Córnea , Estudos Transversais , Feminino , Humanos , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Ceratocone/cirurgia , Masculino , Prevalência , República da Macedônia do Norte/epidemiologia , Estudos Retrospectivos
3.
Graefes Arch Clin Exp Ophthalmol ; 259(8): 2259-2268, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33885984

RESUMO

PURPOSE: To evaluate changes in corrected distance visual acuity (CDVA), ratio of anterior and posterior corneal radii over the thinnest region of the cornea (ARC/PRC), and astigmatism after cross-linking (CXL) in keratoconus. METHODS: Subjective refraction and ARC/PRC (using Pentacam™) were monitored over 1 year in (I) keratoconus treated with routine CXL (n = 53), (II) relatively stable keratoconus (n = 23), and (III) age/gender matched controls (n = 24). RESULTS: CDVA (median, mode, interquartile range) improved significantly in group I, compared with groups II and III (p < 0.05), from 0.45 (0.60, 0.20-0.63) to 0.80 (0.95, 0.60-0.95); change in CDVA was associated with preop CDVA (p < 0.01 at all times postop). ARC/PRC (mean ± sd, 95% CI) changed from 1.362 (± 0.048, 1.347-1.377) to 1.425 (± 0.073, 1.401-1.449). CDVA and ARC/PRC remained stable in II and III. Significant relationships were revealed between logCDVA and ARC/PRC in I and II (at 12 months, I rs = - 0.464, II rs - 0.449) and logCDVA at postop(y), log CDVA at preop(x1), and ARC/PRC at preop(x2) in I (at 12 months, y = 0.356x1 - 1.312x2 + 1.806, r21 = 0.494, r22 = 0.203). Astigmatic power (mean ± sd, 95% CI) improved from - 3.10DC (± 1.52, - 3.55 to - 2.66) to - 2.53DC (± 1.24, - 2.90 to - 2.17) in I, and worsened from - 1.27DC (± 1.32, - 1.81 to - 0.73) to - 1.61DC (± 1.28, - 2.13 to - 1.09) in II. Vector analysis revealed in group I (a) the power of the surgically induced astigmatism (SIA) was linked to astigmatic power at preop and (b) the difference between the axis of astigmatism at preop(ø) and the axis of the SIA was linked to ø. CONCLUSION: CXL improved CDVA, increased the ARC/PRC ratio, and modified the association between CDVA and ARC/PRC. The change in CDVA was linked to preop CDVA and ARC/PRC values. The association between SIA and preop astigmatism implies there is not a simple cause and effect relationship with CXL.


Assuntos
Astigmatismo , Ceratocone , Fotoquimioterapia , Astigmatismo/diagnóstico , Colágeno/uso terapêutico , Córnea , Substância Própria , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Humanos , Ceratocone/diagnóstico , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual
4.
Optom Vis Sci ; 95(11): 1064-1076, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30339639

RESUMO

SIGNIFICANCE: Small incision lenticule extraction (SMILE) is advanced as the most minimally invasive and least traumatic corneal procedure for correcting refractive errors using a single laser. Although SMILE obtains similar results to femtosecond laser in situ keratomileusis (LASIK) with spherical myopia, it has deficiencies in astigmatism correction. PURPOSE: The purpose of this study was to compare refractive outcomes and high-order aberrations (HOAs) between SMILE and femtosecond LASIK corneal procedures at 1 year post-operative. METHODS: Ninety-two patients (181 eyes) with myopia/myopic astigmatism underwent either SMILE (group 1) or femtosecond LASIK (group 2). The refractive target was to achieve emmetropia in all cases. Data were analyzed to determine significance of change in refraction and HOAs. Furthermore, astigmatism was subjected to vector analysis using the Thibos (calculation of change, Δ, in J0 and J45 values) and Alpins (calculation of difference, ΔC, between target-induced astigmatism [TIA] and surgically induced astigmatism) methods. RESULTS: Forty-five patients (89 eyes) from group 1 and 47 patients (92 eyes) from group 2 completed the study. The main significant (P ≤ .001) findings were as follows: (a) residual astigmatism was greater in group 1; (b) group 1, ΔJ0 = 1.015J0 + 0.040 (R = 0.861), ΔJ45 = 1.082J45 + 0.019 (R = 0.792), ΔC = 0.401TIA + 0.323 (R = 0.489), and mean spherical aberration increased from -0.003 (SD, ±0.059; 95% confidence interval [CI], -0.015 to 0.009) to 0.028 µm (SD, ±0.041; 95% CI, -0.037 to -0.020); and (c) group 2, ΔJ0 = 0.952J0 - 0.005 (R = 0.921), ΔJ45 = 0.962J45 - 0.002 (R = 0.923), ΔC = 0.187TIA + 0.101 (R = 0.272), mean coma reduced from 0.114 (SD, ±0.087; 95% CI, 0.096 to 0.132) to 0.077 µm (SD, ±0.059; 95% CI, 0.065 to 0.089), and trefoil from 0.089 (SD, ±0.049; 95% CI, 0.079 to 0.0990) to 0.056 µm (SD, ±0.047; 95% CI, 0.046 to 0.066). CONCLUSIONS: In comparison with SMILE, femtosecond LASIK offered better precision in the overall control of astigmatism and HOAs.


Assuntos
Astigmatismo/cirurgia , Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratoplastia Penetrante/métodos , Lasers de Excimer/uso terapêutico , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Astigmatismo/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Testes Visuais , Adulto Jovem
5.
Graefes Arch Clin Exp Ophthalmol ; 253(12): 2325-33, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26400154

RESUMO

PURPOSE: To compare the outcomes of astigmatic laser in-situ keratomileusis (LASIK) procedures between two different platforms using J0 and J45 vector analysis. METHODS: Patients were divided into four groups, depending on the type of astigmatism and laser platform on which they were treated. Astigmatism was between 2 and 7 diopters (D). One hundred and thirty-five patients with myopic astigmatism (246 eyes) and 102 patients with mixed astigmatism (172 eyes) underwent unremarkable LASIK correction on Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S laser platform. The preoperative and postoperative sphere, negative cylinder [C] and axis (ø) of manifest refractions were subjected to vector analysis by calculations of the standard J0 (cos [4π(ø-90)/360]xC/2) and J45 (sin[4π(ø-90)/360]xC/2). RESULTS: Reporting the key results, we found J0 significantly reduced after LASIK in both groups (p < 0.001) but not J45. There was no significant association between individual pairs of pre and postoperative J0 & J45 values. There was no significant difference between the outcomes of the two platforms. CONCLUSIONS: Wavelight Allegretto 400Hz and Schwind Amaris 750S showed excellent results for treating patients with astigmatism, regardless whether it is mixed or myopic astigmatism. The J45 did not reduce significantly possibly because of the low number of eyes with oblique astigmatism. There was no genuine difference post-operatively between groups treated on two different laser platforms according to the vector analyses.


Assuntos
Astigmatismo/cirurgia , Córnea/fisiopatologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adulto , Astigmatismo/fisiopatologia , Feminino , Humanos , Masculino , Miopia/fisiopatologia , Período Pós-Operatório , Período Pré-Operatório , Estudos Prospectivos , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia
6.
Graefes Arch Clin Exp Ophthalmol ; 252(10): 1679-86, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25150049

RESUMO

PURPOSE: To compare functional outcomes of Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S excimer laser for astigmatism between 2 and 7 diopters(D). METHODS: Prospective comparative non-randomized case series of 480 eyes assigned in two laser groups and further divided into myopic and mixed astigmatism subgroups. All treatments were centered on corneal vertex. One-year results were compared between the groups. Statistical analysis was performed using z-test. RESULTS: Both Allegretto and Amaris postoperative uncorrected distance visual acuity (UDVA) improved in comparison to preoperative corrected distance visual acuity (CDVA). The difference was significant in the Allegretto group for myopic astigmatism (p = 0.017). There was no difference in postoperative UDVA between lasers. Average sphere decreased in all groups for both lasers (p < 0.001) without difference in effectiveness of spherical correction between lasers for both groups. In Allegretto, average cylinder decreased from -3.30D to -0.55D in myopic astigmatism (p < 0.001) and from -3.84D to -0.85D in mixed astigmatism (p < 0.001). In Amaris average cylinder decreased from -3.21D to -0.43D in myopic astigmatism (p < 0.001) and from -3.66D to -0.58D in mixed astigmatism (p < 0.001). Amaris group had less residual astigmatism (myopic astigmatism p = 0.023, mixed astigmatism p < 0.001). Mean spherical aberration shifted from positive to negative in mixed astigmatism for both lasers. CONCLUSION: Both lasers are effective in terms of UDVA, CDVA, spherical correction, and preservation of high-order aberrations. However, Amaris was more effective in cylinder correction.


Assuntos
Astigmatismo/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/instrumentação , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Aberrometria , Adulto , Astigmatismo/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Estudos Prospectivos , Adulto Jovem
7.
Clin Ophthalmol ; 18: 1637-1650, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855012

RESUMO

Purpose: To determine if the changes in stereoacuity and aniseikonia, following bilateral implantation of presbyopia correcting intraocular lenses could be predicted from preoperative measurements of higher order aberrations (HOAs), axial lengths (AL), refractive errors (RE) and corrected visual acuities (CVAs). Patients and Methods: Stereoacuity (Randot tests, @6m & 40cm, in steps of 20 arcsecs") vertical and horizontal aniseikonia (Awaya test @6m, in steps of 1%) with best correction and HOAs (Shack-Hartmann aberrometer) were measured before, 3 and 6 months after uncomplicated bilateral phacoemulsification. Twenty patients (I) underwent a mix-and-match procedure (Tecnis MF, ZKB00 in one eye and ZLB00 in the other), 17 (II) were implanted with a trifocal (AT LISA 839 triMP) and 18 (III) with a one-piece diffractive (Synergy OU) intraocular lens. The resultant aniseikonia (AR) of vertical and horizontal pairs of aniseikonia measurements was calculated using the Pythagorean theorem. Twenty untreated age/gender matched cases were recruited as controls (IV). Results: The key results (p < 0.001) were a) stereoacuity at distance (SAD) and near (SAN) improved, AR reduced in groups I, II & III remaining unchanged in group IV; b) some significant intergroup differences in SAD, SAN & AR were detected at postop; c) at 6 months postop, changes (Δ=pre- minus postoperative value) correlated with preoperative values (x). Linear regression revealed, I ΔSAD=0.66x-57.47 [0.832, ±66.4], ΔSAN=0.96x-34.59 [0.821, ±16.9], ΔAR=0.93AR-2.12 [0.795, ±1.4] II ΔSAD=0.79x-62.91 [0.916, ±38.1], ΔSAN=0.96x-31.49 [0.892, ±8.0], ΔAR=0.91AR-0.91 [0.839, ±1.3] III ΔSAD=0.67x-35.50 [0.991, ±23.7], ΔSAN=0.88x-38.51[0.988, ±10.6], ΔAR=0.86AR-0.96 [0.900, ±1.3]. Figures in parentheses are the corresponding rs and ±limits of agreement between actual and estimated values. Definitive overarching associations connecting interocular differences in HOAs, AL, RE, and CVAs with SAD, SAN and AR were not found. Conclusion: Changes in stereoacuity and aniseikonia can be predicted using preoperative values. ΔSAN can be predicted within ±1, and ΔAR within ±2, scale divisions. In group III ΔSAD can be predicted within ±1, and in group I ±3, scale divisions.

8.
Eye (Lond) ; 37(18): 3768-3775, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37277614

RESUMO

BACKGROUND: To evaluate vision 3 months after SmartSight lenticule extraction treatments. DESIGN: Case series. METHODS: This case series of patients were treated at Specialty Eye Hospital Svjetlost in Zagreb, Croatia. Sixty eyes of 31 patients consecutively treated with SmartSight lenticule extraction were assessed. The mean age of the patients was 33 ± 6 years (range 23-45 years) at the time of treatment with a mean spherical equivalent refraction of -5.10 ± 1.35 D and mean astigmatism of 0.46 ± 0.36 D. Monocular corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA) were assessed pre- and post-operatively. Ocular and corneal wavefront aberrations have been postoperatively compared to the preoperative baseline values. Changes in ocular wavefront refraction, as well as changes in keratometric readings are reported. RESULTS: At 3 months post-operatively, mean UDVA was 20/20 ± 2. Spherical equivalent showed a low myopic residual refraction of -0.37 ± 0.58 D with refractive astigmatism of 0.46 ± 0.26 D postoperatively. There was a slight improvement of 0.1 Snellen lines at 3-months follow-up. Compared to the preoperative status, ocular aberrations (at 6 mm diameter) did not change at 3 months follow-up; whereas corneal aberrations increased (+0.22 ± 0.21 µm for coma; +0.17 ± 0.19 µm for spherical aberration; and +0.32 ± 0.26 µm for HOA-RMS). The same correction was determined using changes in ocular wavefront refraction, as well as changes in keratometric readings. CONCLUSION: Lenticule extraction after SmartSight is safe and efficacious in the first 3 months postoperatively. The post-operative outcomes indicate improvements in vision.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Astigmatismo/cirurgia , Topografia da Córnea , Resultado do Tratamento , Lasers de Excimer/uso terapêutico , Refração Ocular , Aberrações de Frente de Onda da Córnea/cirurgia , Substância Própria
9.
J Refract Surg ; 39(11): 728-735, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37937760

RESUMO

PURPOSE: To assess the predictability between the SCHWIND ATOS femtosecond laser (SCHWIND eye-tech-solutions) read-out and achieved lenticule thickness measured using MS-39 anterior segment optical coherence tomography (ASOCT; CSO) at the corneal vertex at postoperative 1 day and 1 and 3 months of follow-up. METHODS: This retrospective case series included 130 eyes of 65 consecutive patients who were treated with SmartSight (SCHWIND eye-tech-solutions) lenticule extraction. Sixty-four percent of patients were women with a mean spherical refraction of -4.98 ± 1.19 diopters (D) and mean astigmatism of 0.53 ± 0.64 D. The measurements were performed using AS-OCT with the Phoenix Software v 4.1.1.5. Lenticule thickness was obtained by the subtraction method between preoperative and postoperative total corneal thickness. RESULTS: A lower reduction in central corneal thickness (CCT) compared to the laser read-out for all three follow-up visits can be observed. Essentially, the reduction in CCT was identical at 3 months versus 1 month. The reduction in CCT was lowest at postoperative 1 day. Examining the 1- and 3-month data (essentially equivalent), one can see a best fit of y = 0.94 x -7 µm. CONCLUSIONS: The reduction in CCT was stable from 1 month of follow-up. The stable reduction in CCT was -6% (-1.5% after accounting for design decisions) and -7 µm lower than the respective laser read-out. The findings are predictable, showing a certain level of the lenticules becoming slightly thinner than their respective laser read-outs. [J Refract Surg. 2023;39(11):728-735.].


Assuntos
Cirurgia da Córnea a Laser , Miopia , Humanos , Feminino , Masculino , Acuidade Visual , Substância Própria/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Refração Ocular , Miopia/cirurgia , Cirurgia da Córnea a Laser/métodos
10.
Acta Inform Med ; 31(1): 62-67, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37038487

RESUMO

Background: Among various visual functions, stereoacuity, or the ability to perceive depth, is the most sophisticated binocular function. Many publications discuss the influence of retinal image formation by multifocal intraocular lenses on glare and contrast sensitivity, but only a few present results of testing binocular vision in patients with multifocal intraocular lenses. Objective: This article is designed to review the results of testing binocular vision in patients with multifocal intraocular lenses implanted in cataract surgery. Methods: This article was performed based on a literature review and Internet search through scientific databases such as PubMed, Scopus, Web of Science, and Google Scholar. Results: Some reports found that patients implanted with the monofocal lens, when measured with a near addition, presented statistically significant better stereoacuity scores than those implanted with any of the multifocal intraocular lens types. When the TNO test was used for measurement, statistically significant better stereoacuity was disclosed with the refractive multifocal intraocular lens than with the diffractive-based multifocal intraocular lens design. Stereoacuity scores, even within the same types of lenses, were significantly better with the Titmus test than with the TNO test. Conclusion: Stereoacuity is not affected by multifocality-induced retinal blur as it is by other causes of image degradation such as small residual refractive error very early opacification of ocular media or dry eye. Multifocal intraocular lenses do not cause more functional aniseikonia than would be expected with a monofocal intraocular lens. Since stereoacuity is compromised with unilateral multifocal intraocular lens implantation bilateral implantation should be attempted.

11.
Mater Sociomed ; 35(1): 73-78, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37095881

RESUMO

Background: Corneal ectasia is a sight-threatening complication of corneal refractive surgery characterized by progressive steepening and thinning of the cornea and subsequent loss of best-corrected visual acuity. Objective: To report the clinical outcomes following treatment of post-laser in situ keratomileusis (LASIK) induced ectasia. Methods: This is a retrospective case series of 7 patients (10 eyes) which developed post-LASIK ectasia. In these cases of postoperative ectasia, the presented clinical signs were either forme fruste keratoconus, thin cornea, posterior elevation map value > +15.0µm, or residual stromal bed < 300µm. All cases were treated with either collagen crosslinking (CXL) alone or combined with PRK or CXL and phakic intraocular implant using the Dresden protocol and a slight modification thereof. In all cases, the flap was created using the Moria M2 mechanical microkeratome (average flap thickness 118.15±12.88µm), and refractive error was corrected using the Wavelight Allegretto excimer laser. Results: Average preoperative corrected visual acuity (CDVA) was 0.75 (±0.26) Snellen. Postoperative CDVA significantly increased to 0.86 (±0.13) Snellen (p=0.04, paired t-test). One eye lost three lines of its baseline CDVA (before ectasia), while all other eyes regained lines of CDVA. All cases remained stable during the follow-up. Conclusion: Several surgical procedures are used for the management of corneal ectasia. However, the best surgical approach should be determined based on the state of progression of the disease. Although ectasia remains a potentially devastating complication after refractive surgery, most patients can regain functional visual acuity with appropriate management, and corneal transplantation is infrequently indicated.

12.
Eur J Ophthalmol ; 32(5): 2638-2645, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34761687

RESUMO

PURPOSE: To compare changes in astigmatism by refraction and total corneal astigmatism after tPRK, LASIK and FsLASIK. SETTING: Specialty Eye Hospital Svjetlost, Zagreb, Croatia. DESIGN: Partially masked, semi-randomized, prospective, case-by-case, interventional, clinical study. METHODS: Patients with a stable refraction (-0.75DS to -8.00DS, astigmatism ≤1.00DC) underwent tPRK, LASIK or FsLASIK without complication. Astigmatism was measured at both corneal surfaces over the central 3.2 mm zone (approximately using Pentacam HRTM) preoperatively and 3 months postoperatively. Pentacam and refraction data were subjected to vector analysis to calculate the surgically induced changes in i) total corneal astigmatism (SIATCA) ii) any astigmatism by refraction (SIAR) and the vectorial difference (DV) between SIATCA and SIAR. RESULTS: Reporting key findings (p < .01), there was a significant difference between mean SIATCA and SIAR powers after tPRK (75eyes) but not after LASIK (100eyes) or FsLASIK (100eyes). Mean (±sd,95% CIs) values for DV powers were, tPRK -1.13DC(±0.71, -1.29 to -0.97), LASIK -0.39DC(±0.23,-0.44 to -0.34), FsLASIK -0.55DC(±0.38,-0.62 to -0.47). The differences were significant. For the tPRK and FsLASIK cases, linear regression revealed significant associations between I) SIATCA (x) &DV (z) powers (tPRK z = 1.586x-0.179, r = 0.767, p < .01; FsLASIK z = 0.442x-0.303, r = .484,p < .01), II) sines of SIATCA (x1) &DV (z1) axes (tPRK, z1 = 0.523 × 1 + 0.394, r = .650,p < .01; FsLASIK z1 = 0.460 × 1-0.308, r = .465,p < .01). CONCLUSIONS: tPRK is more prone to unintended changes in astigmatism. The difference between SIATCA & SIAR after tPRK or FsLASIK is mediated by SIATCA. Photoablating deeper regions of the cornea reduces the gap between SIATCA & SIAR.


Assuntos
Astigmatismo , Doenças da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Astigmatismo/cirurgia , Córnea/cirurgia , Doenças da Córnea/cirurgia , Humanos , Estudos Prospectivos , Refração Ocular , Resultado do Tratamento
13.
Coll Antropol ; 35 Suppl 2: 161-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22220426

RESUMO

This study reports early outcomes of a cohort of presbyopic patients treated with Intracor. The study took place from December 2010 to May 2011 and was conducted in University Eye Hospital "Svjetlost", Zagreb, Croatia. 95 eyes were enrolled in this prospective clinical trial (49 patients with non dominant eye and 23 with bilateral treatment). All patients gave informed consent prior to enrollment. Follow up consisted of uncorrected and corrected distant and near visual acuity, record of topographic changes, visual disturbances and patient satisfaction at 1 week, 1 and 3 months after the surgery. In this study Intracor procedure presented as both safe and effective with all eyes gaining several lines of uncorrected near visual acuity (UNVA), and achieving good uncorrected distant visual acuity(UDVA) as well. UDVA was affected by a mild myopic shift, which was effective in reducing mild preexisting hyperopia in some patients but led to a mild myopic outcome in previously emmetropic patients. Statistically significant improvement in UDVA and UNVA was observed in all time points. At 3 months of postoperative follow up all patients gained several lines of UNVA with monocular UNVA Jaeger system 1.67 +/- 0.28. UDVA showed slight improvement over time and initial myopic shift showed tendency of slight decrease with all patients achieving 1.0. Overall patients satisfaction was very high (98%) with only a few (3 patients, 5 eyes) reporting mild halo and glare at 3 months postop.Intracor procedure has proven its short-term safety and efficacy in treating presbyopia. However, longer follow up period is needed.


Assuntos
Cirurgia da Córnea a Laser/métodos , Lasers , Presbiopia/terapia , Acuidade Visual , Estudos de Coortes , Cirurgia da Córnea a Laser/instrumentação , Croácia , Seguimentos , Humanos , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos
14.
Semin Ophthalmol ; 36(8): 832-838, 2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34010104

RESUMO

Purpose: To compare predicted and measured changes in astigmatism at the posterior corneal surface (PCS) after FsLASIK or LASIK.Methods: Astigmatism was measured at both corneal surfaces (PentacamTM) before and 3 months after unremarkable FFsLASIK (roup 1,n = 100) or LLASIK (roup 2,n = 100) for myopia (-7.25DS to -0.75DS) and low astigmatism (≤1.00DC). Photoablation was achieved using Schwind Amaris750STM laser (Aberration Free profile, centered on corneal vertex). Pre-and postop astigmatic data, according to subjective refraction and estimates for the corneal surfaces (over the central 3.2 mm zone), were subjected to vector analysis to calculate surgically induced astigmatism (SIA) by refraction (SIAR), at the anterior (SIAFact) and posterior corneal surfaces (SIABact). The difference vector between SIAR and SIAFact was regarded as the predicted SIA at the PCS (SIABest).Results: Reporting key findings. Mean(±sd,95%CI) SIABest and SIABact powers in group 1 were -0.52DC(±0.35,-0.56 to -0.45) and -0.11DC(±0.08,-0.13 to -0.10) in group 1, -0.35DC(0.20,-0.39 to -0.32) and -0.08DC(0.07,-0.09 to -0.06) in group 2. Differences between SIABest and SIABact were significant for powers but not axes. Significant correlations(p < .01) were revealed between (I) SIAR and SIAFact powers [Group 1, SIAR = 0.370.SIAFact-0.292,r = 0.299. Group 2, SIAR = 0.484.SIAFact-0.394,r = 0.519] but not the axes and (II) ΔC (difference between pre-[x1] and postop measured PCS astigmatic powers) and x1 [Group 1, ΔC = 0.384x1 + 0.119,r = 0.423. Group 2, ΔC = 0.135x1 + 0.047,r = 0.229,p = .022]. There was no correlation between SIABest and SIABact powers or axes.Conclusion: The changes in posterior corneal astigmatic powers according to Pentacam measurements are small and do not account for the deficit between SIAR and SIAFact after FsLASIK or LASIK.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Astigmatismo/etiologia , Astigmatismo/cirurgia , Córnea/cirurgia , Substância Própria , Topografia da Córnea , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Refração Ocular , Acuidade Visual
15.
Med Arch ; 75(3): 204-208, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34483451

RESUMO

BACKGROUND: The creation of corneal flap is considered to be the most critical part of laser in situ keratomileusis (LASIK) surgery. Currently, flaps can be created with mechanical micorkeratomes or femtosecond lasers. OBJECTIVE: To analyze and compare flap characteristics created with two different methods for flap creation in Laser in situ keratomileusis (LASIK). METHODS: This was a retrospective study. The thickness and morphology of the flap were compared between the two mechanical microkeratomes (group I - Moria M2, group II - Moria SBK One Use Plus) and femtosecond laser (group III - Ziemer Femto LDV). Central flap thickness was measured intraoperatively, while the flap profile was measured with anterior optical coherence tomography at two axes (90° and 180°) and 5 measuring points on the first day, the first week, and one month after the surgery. RESULTS: Central flap thickness was 110.91±15.79 micrometers (µm) (80-164 µm) in group I, 98.08±13.33 µm (65-136 µm) in group II and 103.52±13.89 µm (66-138 µm) in group III. Anterior optical coherence tomography revealed a meniscus-shaped flap in all three groups at both axes (90° and 180°). The least variability in flap thickness was observed in group III (±6 µm). CONCLUSION: All three methods of flap creation provide good shape and thickness reproducibility. Ziemer Femto LDV femtosecond laser had the least variable flap thickness in a single flap. Mechanical microkeratomes had slightly lower performance.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
J Refract Surg ; 37(4): 256-262, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34038663

RESUMO

PURPOSE: To evaluate the clinical outcomes including patient-reported outcome measures in a sample of eyes undergoing bilateral cataract surgery with implantation of a new model of presbyopia-correcting intraocular lens (IOL). METHODS: This non-randomized prospective case series enrolled 206 eyes of 103 patients undergoing phacoemulsification cataract surgery with bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Vision). High and low contrast visual acuity, refractive, defocus curve, and patient-reported visual performance (Catquest-9SF questionnaire) outcomes were evaluated during a 3-month follow-up. RESULTS: A total of 96.1% (99 of 103) and 91.3% (94 of 103) of patients achieved binocular postoperative uncorrected distance (UDVA) and near visual acuity (UNVA) of 0.00 logMAR (20/20), respectively. Mean postoperative mesopic UNVA for both eyes was 0.14 ± 0.03 logMAR. Likewise, mean binocular UDVA and UNVA were 0.00 ± 0.03 and 0.04 ± 0.02 logMAR. An almost flat mean defocus curve was obtained, with visual acuities between 0.00 and 0.10 logMAR for most defocus levels in both eyes. A reduction of contrast led to a limited but statistically significant change in UNVA in both eyes (P < .001). The Rasch calibrated scoring of item 2 and the Rasch calibrated mean score of the Catquest-9SF questionnaire increased significantly with surgery (P < .001). CONCLUSIONS: This new presbyopia-correcting IOL provides a continuous range of functional focus, with a limited deterioration under mesopic conditions, which is perceived as a satisfactory outcome by the patient if proper patient selection is performed. [J Refract Surg. 2021;37(4):256-262.].


Assuntos
Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Implante de Lente Intraocular , Satisfação do Paciente , Presbiopia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Refração Ocular , Visão Binocular
17.
Eur J Ophthalmol ; 31(4): 1725-1732, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32597207

RESUMO

PURPOSE: To determine if the manifest sphero-cylindrical residual refractive error, at various time points over a 12-month postop period after laser in situ keratomileusis (LASIK) was associated with patient age at time of surgery. METHODS: Patients with moderate to high hyperopia (3.00-7.00 DS) and astigmatism ⩽2 DC underwent LASIK using Wavelight Allegretto Eye Q (400 Hz). Treatments were centered on corneal vertex, flaps were made with Moria M2 mechanical microkeratome. Pre-and postoperative uncorrected and corrected distant visual acuity, best corrected spherical equivalent (SEQ) were measured. Measurements were taken at 1 week, 1, 3, 6, and 12 months after the surgery. Target refraction was emmetropia. Total of 161 patients were treated. In binocular cases, data from the right eyes were included for analysis. In this article, we report on refraction data only. Raw data were subjected to several permutations to elicit any links between refractive outcomes and patient age. RESULTS: The key findings were as follows y = postop SEQ (diopters), x = patient age (years), ln(x) = natural logarithm of patient age: At 1 month, y = x[0.049 -0.011.ln(x)] (R = -0.205, p = 0.001, n = 161). At 3 months, y = x[0.077 -0.017.ln(x)] (R = -0.355, p < 0.001, n = 161). At 6 months, y = x[0.088 -0.020.ln(x)] (R = -0.382, p < 0.001, n = 161). At 12 months, y = x[0.093 -0.021.ln(x)] (R = -0.409, p < 0.001, n = 161). There was no significant association between x and y at 1 week (p > 0.05). CONCLUSION: Residual postop refractive error after LASIK for hyperopia has a logarithmic association with patient age at time of surgery. In younger patients there is tendency toward undercorrection, the opposite occurs in older patients and this persists 1 year after treatment.


Assuntos
Astigmatismo , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Idoso , Astigmatismo/etiologia , Astigmatismo/cirurgia , Córnea , Humanos , Hiperopia/etiologia , Hiperopia/cirurgia , Lactente , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Lasers de Excimer/uso terapêutico , Refração Ocular , Resultado do Tratamento , Acuidade Visual
18.
Coll Antropol ; 34 Suppl 2: 275-7, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21302732

RESUMO

Secondary chronic open-angle glaucoma associated with pseudoexfoliation (PEX) syndrome accounts for approximately 25% of all glaucomas and represents the most common identifiable cause of glaucoma overall. Selective laser trabeculoplasty (SLT) is effective in reducing intraocular pressure (IOP) in glaucomatous patients and has the advantage of preserving surrounding structures. We report here SLT treatment of a 82 year old female with a secondary developed open-angle pseudoexfoliation glaucoma allergic to all anti glaucoma eye drops especially those which contain bensalconium chloridum as preservative. Since patient was allergic also to methyl-cellulose, we performed SLT with water as a mediator. Patient had PEX syndrome for 10 years, immature cataracts on both eyes, and best corrected visual acuity (BCVA) 0.7 on the right and 0.2 on the left eye. We have monitored intraocular pressure (IOP), the changes in the visual field and optic nerve. Preoperative IOP was 28 mmHg on the right and 30 mmHg on the left eye. The follow up period was 24 months with time points for measured parameters every 3 months. After 18 months IOP remained in the normal values (average 17 mmHg) on the right eye, but on the left eye it increased up to 28 mmHg. SLT re-treatment was carried out on the left eye and the IOP stabilized again on the values between 16-18mmHg. There were no significant change in the visual field and optic nerve configuration before and after SLT (C/D value for right eye: 0.3-0.4; C/D left eye: 0.5). Based on this case report, SLT seems to be very effective treatment for maintaining regular IOP in patient with PEX who is allergic to all types of medications.


Assuntos
Hipersensibilidade a Drogas , Síndrome de Exfoliação/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Terapia a Laser/métodos , Soluções Oftálmicas , Trabeculectomia/métodos , Idoso de 80 Anos ou mais , Contraindicações , Síndrome de Exfoliação/tratamento farmacológico , Feminino , Glaucoma de Ângulo Aberto/tratamento farmacológico , Humanos , Resultado do Tratamento
19.
Coll Antropol ; 34 Suppl 2: 95-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21302708

RESUMO

There are several methods for presbyopia treatment. Refractive lens exchange (RLE) followed by multifocal intraocular lens (MFIOL) implantation enables high rate of spectacle independence but have some visual disturbances. Laser in Situ Keratomileusis (LASIK) monovision gives patient ability to have good distant vision with dominant eye and good near vision with nondominant eye. In this prospective randomized study we wanted to compare clinical outcomes in patients who underwent either of the mentioned procedures. The first group included 50 patients (N = 100 eyes) who underwent RLE with MFIOL implantation and the second group included 50 patients (N = 100 eyes) who underwent LASIK monovision as presbyopia treatment. Uncorrected distant, near and intermediate visual acuity, patient's subjective satisfaction and visual disturbances were measured. Follow up was 6 months. Patients in RLE group had better near uncorrected visual acuity (UCVA) and patients in LASIK monovision group had better distant and intermediate vision. Patients in RLE group reported visual disturbances (halo, glare). Patients satisfaction and spectacle independence was high in both groups. Refractive lens exchange with multifocal intraocular lens implantation and LASIK monovision are effective methods for presbyopia treatment. LASIK monovision with -0.50D - 1.25D of residual dioptry at nondominant eye in patients under 50 years enables good vision at all distances without affecting stereovision. Patient selection and preoperative counseling are key to success.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Implante de Lente Intraocular/métodos , Presbiopia/cirurgia , Presbiopia/terapia , Acuidade Visual , Óculos , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
20.
Acta Inform Med ; 28(2): 98-102, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32742060

RESUMO

INTRODUCTION: Refractive surgery procedures, transepithelial photorefractive keratectomy (T-PRK), and femtosecond laser in situ keratomileusis (Fs-LASIK) are regarded as safe and efficacious methods for correcting myopia and myopic astigmatism. These two methods do not have many differences in results when treating spherical myopia while differences exist in the treatment of astigmatism correction. Vector analysis presents a powerful tool to show the real differences between these two methods regarding high ocular aberrations and central corneal thickness of treated eyes. AIM: The aim of the study is to investigate changes in higher order ocular aberrations (HOAs) and central corneal thickness (CCT) following treatment of myopia and myopic astigmatism above -5.00DS and up to -2.00DC after either T-PRK or Fs-LASIK. METHODS: Patients (30 eyes per group) underwent T-PRK (group I) or Fs-LASIK (group II) procedure using the Schwind Amaris 750S laser. HOAs (3mm&5mm pupil) and CCT were measured objectively at pre-, 1,3 & 6 months postop in each case. RESULTS: Key results at 6 months were: i) mean values of trefoil (5mm pupil) were 0.092µm (sd,0.055,95% CI 0.072 to 0.112) & 0.126µm (sd,0.078,95% CI 0.098 to 0.154) in group I, and 0.088µm (sd,0.058,95% CI 0.067 to 0.109) & 0.064µm (sd,0.034,95% CI 0.052 to 0.076) in group II (P=0.001 at 6 months); ii) Changes in CTT (ΔCTT) and best spherical equivalent correction (ΔBSE) was significant in group II (ΔCCT=-26.55[ΔBSE]-14.06,R=0.486,P=0.006) but not in group I (p=0.034). CONCLUSIONS: After T-PRK trefoil is worse than Fs-LASIK. The predictability of corneal changes is better following Fs-LASIK.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA