1.
J Cataract Refract Surg ; 44(9): 1140-1143, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30055953

RESUMO

PURPOSE: To evaluate the optimum on-time setting for the most efficient removal of lens fragments using micropulse ultrasound (US) and Ellips FX transversal US in the Whitestar Signature Pro phacoemulsification machine. SETTING: John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, USA. DESIGN: Experimental study. METHODS: Porcine lens nuclei were soaked in formalin for 2 hours and cut into 2.0 mm cubes. The US machine was used with a bent 0.9 mm phaco tip and a 30-degree bevel. The off time was set to 6 milliseconds (ms) and the on time varied from 4 to 10 ms in 1 ms increments. Efficiency (time for fragment removal) and chatter (number of times the fragment bounced from the tip) were measured. RESULTS: A linear incremental increase in efficiency was observed between 4 ms and 6 ms. The most statistically significant efficiency was achieved with an on time of 6 ms. On times shorter than 6 ms were significantly less efficient (P = .05). Greater on times (7 to 10 ms) did not result in a significant difference in efficiency (P = .72), but did appear to have more chatter events when comparing on-time settings of 7 to 10 ms with 4 to 6 ms (P = .02). CONCLUSIONS: With micropulse transversal US, 6 ms of on time was as efficient as longer on times. To maximize phacoemulsification efficiency and minimize chatter events, an on time of 6 ms is recommended.


Assuntos
Núcleo do Cristalino/cirurgia , Duração da Cirurgia , Facoemulsificação/instrumentação , Ultrassom/instrumentação , Animais , Ondas de Choque de Alta Energia , Suínos , Fatores de Tempo
2.
Am J Ophthalmol ; 183: 107-110, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28860045

RESUMO

PURPOSE: To evaluate the effects of micropulse, long pulse, and continuous ultrasound on transverse ultrasound using Abbott Medical Optics' (AMO) WhiteStar Signature Pro with the Ellips FX handpiece. DESIGN: In vitro laboratory study. METHODS: This study was conducted at the John A. Moran Eye Center Laboratory, University of Utah, Salt Lake City, Utah, USA. Porcine lenses were hardened in formalin for 2 hours and equilibrated in basic salt solution (BSS) over a 24-hour period. The lenses were then cubed in 2.0 × 2.0-mm pieces. These pieces were stored in BSS until the time of experimentation. The AMO WhiteStar Signature Pro machine (Abbott Medical Optics) with the Ellips FX handpiece and a 0.9-mm bent Dewey tip with a 30-degree bevel (Microsurgical Technology Inc) were used for phacoemulsification. Three runs of 20 lenses each were performed, measuring efficiency and chatter. Transverse ultrasound varied in the 3 runs and included continuous, 6 ms on/off micropulse, and 50 ms on/off long pulse. RESULTS: Micropulse was more efficient than long pulse by 43% (P = .00003) and continuous by 42% (P = .000387). There were also less chatter events with micropulse than with long-pulse and continuous ultrasound. However, this difference did not reach significance. CONCLUSION: The 6 ms on and 6 ms off micropulse transverse 3-dimensional ultrasound is more efficient and produces fewer chatter events than both long-pulse and continuous ultrasound.


Assuntos
Catarata/terapia , Ondas de Choque de Alta Energia/uso terapêutico , Cristalino , Facoemulsificação/métodos , Terapia por Ultrassom/métodos , Animais , Modelos Animais de Doenças , Suínos