Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Breast Cancer Res Treat ; 207(1): 223-232, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38769222

RESUMO

BACKGROUND AND OBJECTIVES: Sentinel lymph node (SLN) biopsy is a standard procedure for patients with breast cancer and normal axilla on imaging. Positive SLNs on histological examination can lead to a subsequent surgery for axillary lymph node clearance (ALNC). Here we report a non-destructive technique based on autofluorescence (AF) imaging and Raman spectroscopy for intra-operative assessment of SLNs excised in breast cancer surgery. METHODS: A microscope integrating AF imaging and Raman spectroscopy modules was built to allow scanning of lymph node biopsy samples. During AF-Raman measurements, AF imaging determined optimal sampling locations for Raman spectroscopy measurements. After optimisation of the AF image analysis and training of classification models based on data from 85 samples, the AF-Raman technique was tested on an independent set of 81 lymph nodes comprising 58 fixed and 23 fresh specimens. The sensitivity and specificity of AF-Raman were calculated using post-operative histology as a standard of reference. RESULTS: The independent test set contained 66 negative lymph nodes and 15 positive lymph nodes according to the reference standard, collected from 78 patients. For this set of specimens, the area under the receiver operating characteristic (ROC) curve for the AF-Raman technique was 0.93 [0.83-0.98]. AF-Raman was then operated in a regime that maximised detection specificity, producing a 94% detection accuracy: 80% sensitivity and 97% specificity. The main confounders for SLN metastasis were areas rich in histiocytes clusters, for which only few Raman spectra had been included in the training dataset. DISCUSSION: This preliminary study indicates that with further development and extension of the training dataset by inclusion of additional Raman spectra of histiocytes clusters and capsule, the AF-Raman may become a promising technique for intra-operative assessment of SLNs. Intra-operative detection of positive biopsies could avoid second surgery for axillary clearance.


Assuntos
Neoplasias da Mama , Biópsia de Linfonodo Sentinela , Linfonodo Sentinela , Análise Espectral Raman , Humanos , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Feminino , Análise Espectral Raman/métodos , Linfonodo Sentinela/patologia , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela/métodos , Pessoa de Meia-Idade , Metástase Linfática/patologia , Idoso , Curva ROC , Sensibilidade e Especificidade , Adulto , Imagem Óptica/métodos
2.
Br J Dermatol ; 191(3): 428-436, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-38736216

RESUMO

BACKGROUND: Autofluorescence (AF)-Raman microspectroscopy is a technology that can detect residual basal cell carcinoma (BCC) on the resection margin of fresh, surgically excised tissue specimens. The technology does not require tissue fixation, staining, labelling or sectioning, and provides quantitative diagnosis maps of the surgical margins in 30 min. OBJECTIVES: To determine the accuracy of the AF-Raman instrument in detecting incomplete BCC excisions during Mohs micrographic surgery (MMS), using histology as the reference standard. METHODS: Skin layers from 130 patients undergoing MMS at the Nottingham University Hospitals NHS Trust (September 2022-July 2023) were investigated with the AF-Raman instrument. The layers were measured when fresh, immediately after excision. The AF-Raman results and the intraoperative assessment by Mohs surgeons were compared with a postoperative consensus-derived reference produced by three dermatopathologists. The sensitivity, specificity, and positive and negative predictive values were calculated. The study was registered with ClinicalTrials.gov (NCT03482622). RESULTS: AF-Raman analysis was successfully completed for 125 of 130 layers and, on average, covered 91% of the specimen surface area, with the lowest surface area covered being 87% for the eyelid and the highest being 94% for forehead specimens. The AF-Raman instrument identified positive margins in 24 of 36 BCC-positive cases [67% sensitivity, 95% confidence interval (CI) 49-82] and negative margins in 65 of 89 BCC-negative cases (73% specificity, 95% CI 63-82). Only one of 12 false-negative cases was caused by misclassification by the AF-Raman algorithm. The other 11 false-negatives cases were a result of no valid Raman signal being recorded at the location of the residual BCC due to either occlusion by blood or poor contact between tissue and the cassette window. The intraoperative diagnosis by Mohs surgeons identified positive margins in 31 of 36 BCC-positive cases (86% sensitivity, 95% CI 70-95) and negative margins in 79 of 89 BCC-negative cases (89% specificity, 95% CI 81-95). CONCLUSIONS: The AF-Raman instrument has the potential to provide intraoperative microscopic assessment of surgical margins in BCC surgery. Further improvements are required for tissue processing, to ensure complete coverage of the surgical specimens.


Basal cell carcinoma (BCC) is one of the most common human cancers, occurring mostly on the face and neck. Most BCCs are treated by cutting them out under local anaesthetic. This is routinely done in a hospital by a dermatologist or plastic surgeon. Surgery aims to remove all the cancer leaving the smallest scar possible, but it is often difficult to know how much normal skin to remove. Results from the laboratory often take 1 to 2 weeks to show if the cancer is clear. A technique called 'Mohs' (micrographic surgery) is recommended for these 'high-risk' BCCs. Mohs surgery removes thin layers of skin and investigates them under a microscope while the patient is still in the hospital. This is repeated until all the layers are clear of cancer. Because of the patchy availability of Mohs surgery, many patients with high-risk BCCs are treated by traditional methods that may not be as good as Mohs. We have developed an instrument that scans layers of skin and can quickly detect BCC. The instrument allows surgeons to check each removed skin layer for cancer cells to decide if more layers need to be removed. In this study, the instrument was tested on skin tissue layers from 130 patients who had Mohs surgery at the Nottingham Treatment Centre. The results showed that the instrument can measure skin layers in approximately 30 minutes and identify BCC with a similar accuracy to a Mohs surgeon, but only when the skin layers are prepared properly. With future improvements, the technology might be used to guide Mohs surgery or help surgeons in centres that do not have access to Mohs surgery.


Assuntos
Carcinoma Basocelular , Margens de Excisão , Cirurgia de Mohs , Neoplasias Cutâneas , Feminino , Humanos , Masculino , Carcinoma Basocelular/cirurgia , Carcinoma Basocelular/patologia , Carcinoma Basocelular/diagnóstico , Neoplasia Residual/patologia , Imagem Óptica/métodos , Imagem Óptica/normas , Sensibilidade e Especificidade , Pele/patologia , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/diagnóstico , Análise Espectral Raman/métodos
3.
Sci Rep ; 6: 20811, 2016 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-26857158

RESUMO

This study investigates the temporal and spatial interchange of the aromatic amino acid phenylalanine (Phe) between human retinal pigment epithelial cell line (ARPE-19) and tachyzoites of the apicomplexan protozoan parasite Toxoplasma gondii (T. gondii). Stable isotope labelling by amino acids in cell culture (SILAC) is combined with Raman micro-spectroscopy to selectively monitor the incorporation of deuterium-labelled Phe into proteins in individual live tachyzoites. Our results show a very rapid uptake of l-Phe(D8) by the intracellular growing parasite. T. gondii tachyzoites are capable of extracting l-Phe(D8) from host cells as soon as it invades the cell. l-Phe(D8) from the host cell completely replaces the l-Phe within T. gondii tachyzoites 7-9 hours after infection. A quantitative model based on Raman spectra allowed an estimation of the exchange rate of Phe as 0.5-1.6 × 10(4) molecules/s. On the other hand, extracellular tachyzoites were not able to consume l-Phe(D8) after 24 hours of infection. These findings further our understanding of the amino acid trafficking between host cells and this strictly intracellular parasite. In particular, this study highlights new aspects of the metabolism of amino acid Phe operative during the interaction between T. gondii and its host cell.


Assuntos
Interações Hospedeiro-Patógeno/fisiologia , Marcação por Isótopo , Fenilalanina/metabolismo , Epitélio Pigmentado da Retina , Toxoplasma/fisiologia , Toxoplasmose/metabolismo , Linhagem Celular , Humanos , Epitélio Pigmentado da Retina/metabolismo , Epitélio Pigmentado da Retina/parasitologia , Análise Espectral Raman
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA