Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
ESC Heart Fail ; 7(6): 4377-4383, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32886455

RESUMO

AIMS: The aim of this study is to report heart failure hospitalization (HFH) rates and associated costs within 12 months following implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) device replacement or upgrade from ICD to CRT-D. METHODS AND RESULTS: The DEtect long-term COmplications after icD rEplacement (DECODE) was a prospective, single-arm, multicentre cohort study that explored complications in ICD/CRT-D recipients. All clinical and survival data at 12 months were prospectively analysed. For each adjudicated HFH, admission and discharge dates and ICD-9-CM diagnosis and procedure codes were recorded. The reimbursement for each HFH was calculated for each diagnosis-related group code. Between 2013 and 2015, 983 patients (mean age 71 years, male 76%, mean left ventricular ejection fraction 35%, and New York Heart Association Class I/II 75.6%) were enrolled. Patients underwent device replacement (900; 91.6%, 446 ICD/454 CRT-D) or ICD upgrade to CRT-D (83; 8.4%). Post-replacement hospitalizations occurred in 220 patients, with the primary discharge diagnosis identifying cardiovascular causes in 175 patients (80%). Fifty-five (5.6%) patients experienced at least one HFH. Overall, 91 HFH events occurred (9.6% event rate, 95% confidence interval: 7.7-11.7) in 70 patients; 66 (6.7%) patients died, 40 (60.6%) of cardiovascular causes. The HFH rate was significantly higher following upgrades, and the occurrence of HFH was associated with an 11-fold increased mortality risk (95% confidence interval: 5.9-20.5, P < 0.0001). Medical diagnosis-related group accounted for 91.2% of HFH; the mean cost per HFH was €5662 ± 9497, and the mean cost per patient was €9369 ± 12 687. On multivariate analysis, predictors of HFH were atrial fibrillation, chronic kidney disease, and all-cause hospitalization within 30 days prior to the procedure. CONCLUSIONS: In the DECODE registry, HFH and mortality rates in the year following ICD/CRT-D replacement or upgrade were low. In this particular subset, underlying cardiac disease was the main driver of HFH, mortality, and higher healthcare expenditures.

2.
G Ital Cardiol (Rome) ; 13(2): 132-5, 2012 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-22322554

RESUMO

Persistent left superior vena cava is a rare congenital abnormality. Cases of persistent left superior vena cava with an absent right superior vena cava or the presence of other congenital cardiovascular abnormalities have been rarely described. To the best of our knowledge, this is the first case of a patient with persistent left superior vena cava, absent right superior vena cava and tako-tsubo syndrome observed during an attempt of pacemaker implantation. Such a condition was confirmed by means of contrast echocardiography and coronary angiography.


Assuntos
Marca-Passo Artificial , Implantação de Prótese/efeitos adversos , Cardiomiopatia de Takotsubo/etiologia , Veia Cava Superior/anormalidades , Idoso , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA