1.
Circ J ; 88(7): 1127-1134, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38658350

RESUMO

BACKGROUND: The Micra leadless pacemaker was developed to fit inside the right ventricle, thereby reducing overall complications by 48% compared with a historical control group. The current labeling restricts implants to the femoral approach. In this article we used 3-dimensional computer models of human hearts to demonstrate why implants can be difficult in small patients and how using the jugular approach reduces these difficulties.Methods and Results: Cardiac computed tomography scans were made of 45 pacemaker patients, 26 in the US and 19 from a single center in Japan. Dimensional measurements were taken in all 45 hearts, and these dimensions were compared between patient cohorts and between the Micra delivery tool dimension and patient heart dimensions. Hearts were smaller among patients in the Japanese than US cohort. In addition, the tool dimension exceeded heart dimensions in a larger percentage of hearts from Japanese patients. Three dimensions were identified that most likely limit navigating across the tricuspid valve to the right ventricle in smaller hearts and for which the jugular approach improved navigation. CONCLUSIONS: Although the femoral procedure today maintains an excellent safety profile and procedure experience for most global implants, this study provides the rationale as to why the jugular approach may improve the ease of the Micra implant in small hearts, namely by reducing the tortuosity of the navigation across the tricuspid valve.


Assuntos
Veias Jugulares , Marca-Passo Artificial , Humanos , Veias Jugulares/diagnóstico por imagem , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Ventrículos do Coração , Japão
2.
Circ Res ; 123(11): 1208-1219, 2018 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-30571465

RESUMO

RATIONALE: Cardiac pacing is a critical technology for the treatment of arrhythmia and heart failure. The impact of specific pacing strategies on myocardial function is an area of intense research and high clinical significance. Mouse models have proven extremely useful for probing mechanisms of heart disease, but there is currently no reliable technology for long-term pacing in the mouse. OBJECTIVE: We sought to develop a device for long-term pacing studies in mice. We evaluated the device for (1) treating third-degree atrioventricular block after macrophage depletion, (2) ventricular pacing-induced cardiomyopathy, and (3) high-rate atrial pacing. METHODS AND RESULTS: We developed a mouse pacemaker by refashioning a 26 mm×6.7 mm clinical device powered by a miniaturized, highly efficient battery. The electrode was fitted with a single flexible lead, and custom software extended the pacing rate to up to 1200 bpm. The wirelessly programmable device was implanted in the dorsal subcutaneous space of 39 mice. The tunneled lead was passed through a left thoracotomy incision and attached to the epicardial surface of the apex (for ventricular pacing) or the left atrium (for atrial pacing). Mice tolerated the implantation and both long-term atrial and ventricular pacing over weeks. We then validated the pacemaker's suitability for the treatment of atrioventricular block after macrophage depletion in Cd11b DTR mice. Ventricular pacing increased the heart rate from 313±59 to 550 bpm ( P<0.05). In addition, we characterized tachypacing-induced cardiomyopathy in mice. Four weeks of ventricular pacing resulted in reduced left ventricular function, fibrosis, and an increased number of cardiac leukocytes and endothelial activation. Finally, we demonstrated the feasibility of chronic atrial pacing at 1200 bpm. CONCLUSIONS: Long-term pacing with a fully implantable, programmable, and battery-powered device enables previously impossible investigations of arrhythmia and heart failure in the mouse.


Assuntos
Arritmias Cardíacas/fisiopatologia , Marca-Passo Artificial , Telemetria/métodos , Animais , Eletrodos Implantados , Desenho de Equipamento , Feminino , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Miniaturização , Software , Tempo
3.
J Cardiovasc Electrophysiol ; 27(12): 1495-1501, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27600684

RESUMO

Two major studies have shown that leadless pacemakers are safe and effective for patients requiring right ventricular rate responsive pacing therapy. This positive result recently led to FDA approval of one of the available leadless pacing devices. While this new technology is promising, it requires a different skill set for safe implantation. In this article, we review in detail the different steps required for implantation of tine-based leadless pacemakers while providing tips and tricks to minimize complications.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Desenho de Equipamento , Humanos , Radiografia Intervencionista , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 39(4): 393-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26710918

RESUMO

BACKGROUND: The introduction of transcatheter pacemaker technology has the potential to significantly reduce if not eliminate a number of complications associated with a traditional leaded pacing system. However, this technology raises new questions regarding how to manage the device at end of service, the number of devices the right ventricle (RV) can accommodate, and what patient age is appropriate for this therapy. In this study, six human cadaver hearts and one reanimated human heart (not deemed viable for transplant) were each implanted with three Micra devices in traditional pacing locations via fluoroscopic imaging. METHODS: A total of six human cadaver hearts were obtained from the University of Minnesota Anatomy Bequest Program; the seventh heart was a heart not deemed viable for transplant obtained from LifeSource and then reanimated using Visible Heart(®) methodologies. Each heart was implanted with multiple Micras using imaging and proper delivery tools; in these, the right ventricular volumes were measured and recorded. The hearts were subsequently dissected to view the right ventricular anatomies and the positions and spacing between devices. RESULTS: Multiple Micra devices could be placed in each heart in traditional, clinically accepted pacing implant locations within the RV and in each case without physical device interactions. This was true even in a human heart considered to be relatively small. CONCLUSIONS: Although this technology is new, it was demonstrated here that within the human heart's RV, three Micra devices could be accommodated within traditional pacing locations: with the potential in some, for even more.


Assuntos
Cateteres Cardíacos , Eletrodos Implantados , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/cirurgia , Marca-Passo Artificial , Ajuste de Prótese/métodos , Idoso , Idoso de 80 Anos ou mais , Cadáver , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Desenho de Prótese
5.
Eur Heart J ; 36(37): 2510-9, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26045305

RESUMO

AIMS: Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker. METHODS AND RESULTS: Patients having Class I or II indication for VVI pacing underwent implantation of a Micra transcatheter pacing system, from the femoral vein and fixated in the right ventricle using four protractible nitinol tines. Prespecified objectives were >85% freedom from unanticipated serious adverse device events (safety) and <2 V 3-month mean pacing capture threshold at 0.24 ms pulse width (efficacy). Patients were implanted (n = 140) from 23 centres in 11 countries (61% male, age 77.0 ± 10.2 years) for atrioventricular block (66%) or sinus node dysfunction (29%) indications. During mean follow-up of 1.9 ± 1.8 months, the safety endpoint was met with no unanticipated serious adverse device events. Thirty adverse events related to the system or procedure occurred, mostly due to transient dysrhythmias or femoral access complications. One pericardial effusion without tamponade occurred after 18 device deployments. In 60 patients followed to 3 months, mean pacing threshold was 0.51 ± 0.22 V, and no threshold was ≥2 V, meeting the efficacy endpoint (P < 0.001). Average R-wave was 16.1 ± 5.2 mV and impedance was 650.7 ± 130 ohms. CONCLUSION: Early assessment shows the transcatheter pacemaker can safely and effectively be applied. Long-term safety and benefit of the pacemaker will further be evaluated in the trial. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov ID NCT02004873.


Assuntos
Bloqueio Atrioventricular/terapia , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Idoso , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Microeletrodos , Duração da Cirurgia , Segurança do Paciente , Estudos Prospectivos , Desenho de Prótese , Implantação de Prótese/métodos , Resultado do Tratamento
6.
IEEE Trans Biomed Eng ; 62(9): 2316-23, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26111389

RESUMO

GOAL: The purpose of this paper was to evaluate a nitinol tine fixation design for a transcatheter pacemaker in order to determine if the tines could be easily deployed and safely removed from the myocardium, enable low, stable pacing thresholds, and minimize the potential for dislodgment. METHODS: The penetration properties of 13 human hearts were compared to the deployment and fixation energy of the tines to determine if the tines could be easily deployed and removed from the myocardium. The safety factor for dislodgement was calculated by comparing the kinetic energy of the device to the fixation energy of the tines. The fixation stability was tested in 113 chronic implants across 89 animals via pacing threshold measurements or evidence of dislodgement at necropsy. RESULTS: Based on the tine fixation and tissue energy analysis, the tines can easily penetrate the heart. The tines can be safely removed from the myocardium based on the increased tine surface area during retraction. There were no dislodgements observed in the animals and the mean pacing threshold at implant was 0.59 +/- 0.21 V and at termination was 0.65 +/- 0.36 V. The safety factor for dislodgement was determined to be 15X during simulated exercise conditions. CONCLUSION: The nitinol tine fixation design enabled the implant of a self-contained pacemaker within the right ventricle and was effective in meeting the design requirements. SIGNIFICANCE: This fixation technology provides a novel solution to enable the attachment of a transcatheter pacemaker directly within the heart.


Assuntos
Marca-Passo Artificial , Idoso , Ligas/química , Animais , Humanos , Pessoa de Meia-Idade , Modelos Cardiovasculares , Desenho de Prótese , Ovinos , Suínos , Função Ventricular/fisiologia