Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Cell ; 166(4): 1028-1040, 2016 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-27397506

RESUMO

Fluorescence nanoscopy, or super-resolution microscopy, has become an important tool in cell biological research. However, because of its usually inferior resolution in the depth direction (50-80 nm) and rapidly deteriorating resolution in thick samples, its practical biological application has been effectively limited to two dimensions and thin samples. Here, we present the development of whole-cell 4Pi single-molecule switching nanoscopy (W-4PiSMSN), an optical nanoscope that allows imaging of three-dimensional (3D) structures at 10- to 20-nm resolution throughout entire mammalian cells. We demonstrate the wide applicability of W-4PiSMSN across diverse research fields by imaging complex molecular architectures ranging from bacteriophages to nuclear pores, cilia, and synaptonemal complexes in large 3D cellular volumes.


Assuntos
Técnicas Citológicas/métodos , Microscopia de Fluorescência/métodos , Imagem Individual de Molécula/métodos , Animais , Bacteriófagos/ultraestrutura , Vesículas Revestidas pelo Complexo de Proteína do Envoltório/ultraestrutura , Técnicas Citológicas/instrumentação , Complexo de Golgi/ultraestrutura , Masculino , Camundongos , Microscopia de Fluorescência/instrumentação , Imagem Individual de Molécula/instrumentação , Espermatócitos/ultraestrutura , Complexo Sinaptonêmico/ultraestrutura
2.
Nat Methods ; 18(6): 688-693, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34059828

RESUMO

Understanding cellular organization demands the best possible spatial resolution in all three dimensions. In fluorescence microscopy, this is achieved by 4Pi nanoscopy methods that combine the concepts of using two opposing objectives for optimal diffraction-limited 3D resolution with switching fluorescent molecules between bright and dark states to break the diffraction limit. However, optical aberrations have limited these nanoscopes to thin samples and prevented their application in thick specimens. Here we have developed an improved iso-stimulated emission depletion nanoscope, which uses an advanced adaptive optics strategy to achieve sub-50-nm isotropic resolution of structures such as neuronal synapses and ring canals previously inaccessible in tissue. The adaptive optics scheme presented in this work is generally applicable to any microscope with a similar beam path geometry involving two opposing objectives to optimize resolution when imaging deep in aberrating specimens.


Assuntos
Microscopia de Fluorescência/métodos , Nanotecnologia/métodos , Óptica e Fotônica/métodos , Imageamento Tridimensional , Razão Sinal-Ruído
3.
J Cell Sci ; 134(19)2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34448002

RESUMO

Custom-built microscopes often require control of multiple hardware devices and precise hardware coordination. It is also desirable to have a solution that is scalable to complex systems and that is translatable between components from different manufacturers. Here we report Python-Microscope, a free and open-source Python library for high-performance control of arbitrarily complex and scalable custom microscope systems. Python-Microscope offers simple to use Python-based tools, abstracting differences between physical devices by providing a defined interface for different device types. Concrete implementations are provided for a range of specific hardware, and a framework exists for further expansion. Python-Microscope supports the distribution of devices over multiple computers while maintaining synchronisation via highly precise hardware triggers. We discuss the architectural features of Python-Microscope that overcome the performance problems often raised against Python and demonstrate the different use cases that drove its design: integration with user-facing projects, namely the Microscope-Cockpit project; control of complex microscopes at high speed while using the Python programming language; and use as a microscope simulation tool for software development.


Assuntos
Software , Simulação por Computador , Biblioteca Gênica
4.
Opt Express ; 31(17): 28503-28514, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37710903

RESUMO

Adaptive optics (AO) techniques enhance the capability of optical microscopy through precise control of wavefront modulations to compensate phase aberrations and improves image quality. However, the aberration correction is often limited due to the lack of dynamic range in existing calibration methods, such as interferometry or Shack-Hartmann (SH) wavefront sensors. Here, we use deflectometry (DF) as a calibration method for a deformable mirror (DM) to extend the available range of aberration correction. We characterised the dynamic range and accuracy of the DF-based calibration of DMs depending on the spatial frequency of the test pattern used in DF. We also demonstrated the capability of large magnitude phase control for remote-focusing over a range larger than was possible with SH sensing.

5.
Opt Express ; 30(7): 11809-11824, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35473116

RESUMO

Phase aberrations are introduced when focusing by a high-numerical aperture (NA) objective lens into refractive-index-mismatched (RIM) media. The axial focus position in these media can be adjusted through either optical remote-focusing or mechanical stage translation. Despite the wide interest in remote-focusing, no generalised control algorithm using Zernike polynomials has been presented that performs independent remote-focusing and RIM correction in combination with mechanical stage translation. In this work, we thoroughly review derivations that model high-NA defocus and RIM aberration. We show through both numerical simulation and experimental results that optical remote-focusing using an adaptive device and mechanical stage translation are not optically equivalent processes, such that one cannot fully compensate for the other without additional aberration compensation. We further establish new orthogonal modes formulated using conventional Zernike modes and discuss its device programming to control high-NA remote-focusing and RIM correction as independent primary modes in combination with mechanical stage translation for aberration-free refocusing. Numerical simulations are performed, and control algorithms are validated experimentally by fabricating graphitic features in diamond using direct laser writing.

6.
Opt Express ; 30(9): 15482-15494, 2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35473267

RESUMO

Sapphire optical fiber has the ability to withstand ultrahigh temperatures and high radiation, but it is multimoded which prevents its use in many sensing applications. Problematically, Bragg gratings in such fiber exhibit multiple reflection peaks with a fluctuating power distribution. In this work, we write single-mode waveguides with Bragg gratings in sapphire using a novel multi-layer depressed cladding design in the 1550 nm telecommunications waveband. The Bragg gratings have a narrow bandwidth (<0.5 nm) and have survived annealing at 1000°C. The structures are inscribed with femtosecond laser direct writing, using adaptive beam shaping with a non-immersion objective. A single-mode sapphire fiber Bragg grating is created by writing a waveguide with a Bragg grating within a 425 µm diameter sapphire optical fiber, providing significant potential for accurate remote sensing in ultra-extreme environments.

7.
Opt Express ; 30(14): 24788-24803, 2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-36237024

RESUMO

We present dynamic time-resolved measurements of a multi-pixel analog liquid crystal phase modulator driven at a 1 kHz frame rate. A heterodyne interferometer is used to interrogate two pixels independently and simultaneously, to deconvolve phase modulation with a wide bandwidth. The root mean squared optical phase error within a 30 Hz to 25 kHz bandwidth is <0.5° and the crosstalk rejection is 50 dB. Measurements are shown for a custom-built device with a flexoelectro-optic chiral nematic liquid crystal. However, the technique is applicable to many different types of optical phase modulators and spatial light modulators.

8.
J Microsc ; 288(2): 106-116, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-33128278

RESUMO

Adaptive optics is being applied widely to a range of microscopies in order to improve imaging quality in the presence of specimen-induced aberrations. We present here the first implementation of wavefront-sensorless adaptive optics for a laser-free, aperture correlation, spinning disk microscope. This widefield method provides confocal-like optical sectioning through use of a patterned disk in the illumination and detection paths. Like other high-resolution microscopes, its operation is compromised by aberrations due to refractive index mismatch and variations within the specimen. Correction of such aberrations shows improved signal level, contrast and resolution.


Assuntos
Microscopia , Óptica e Fotônica , Refratometria , Lasers
9.
Opt Express ; 29(22): 36660-36674, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34809072

RESUMO

Rapid autofocusing over long distances is critical for tracking 3D topological variations and sample motion in real time. Taking advantage of a deformable mirror and Shack-Hartmann wavefront sensor, remote focusing can permit fast axial scanning with simultaneous correction of system-induced aberrations. Here, we report an autofocusing technique that combines remote focusing with sequence-dependent learning via a bidirectional long short term memory network. A 120 µm autofocusing range was achieved in a compact reflectance confocal microscope both in air and in refractive-index-mismatched media, with similar performance under arbitrary-thickness liquid layers up to 1 mm. The technique was validated on sample types not used for network training, as well as for tracking of continuous axial motion. These results demonstrate that the proposed technique is suitable for real-time aberration-free autofocusing over a large axial range, and provides unique advantages for biomedical, holographic and other related applications.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/métodos , Microscopia Confocal/instrumentação , Animais , Sistemas Computacionais , Camundongos
10.
Opt Express ; 28(19): 28006-28016, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32988081

RESUMO

Femtosecond laser direct writing is widely used to create waveguide circuits for optical processing in applications including communications, astrophotonics, simulation and quantum information processing. The properties of these waveguide circuits can be sensitive to the fabrication conditions, meaning that noticeable variability can be present in nominally identical manufactured components. One potential solution to this problem is the use of device trimming, whereby additional laser fabrication is applied to optimise the optical properties of a device based upon measurement feedback. We show how this approach can be used in the manufacture of directional couplers by overwriting the laser-written structure to alter the coupling ratios.

11.
Opt Express ; 28(20): 28987-29003, 2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-33114806

RESUMO

Aberrations arising from sources such as sample heterogeneity and refractive index mismatches are constant problems in biological imaging. These aberrations reduce image quality and the achievable depth of imaging, particularly in super-resolution microscopy techniques. Adaptive optics (AO) technology has been proven to be effective in correcting for these aberrations, thereby improving the image quality. However, it has not been widely adopted by the biological imaging community due, in part, to difficulty in set-up and operation of AO. The methods for doing so are not novel or unknown, but new users often waste time and effort reimplementing existing methods for their specific set-ups, hardware, sample types, etc. Microscope-AOtools offers a robust, easy-to-use implementation of the essential methods for set-up and use of AO elements and techniques. These methods are constructed in a generalised manner that can utilise a range of adaptive optics elements, wavefront sensing techniques and sensorless AO correction methods. Furthermore, the methods are designed to be easily extensible as new techniques arise, leading to a streamlined pipeline for new AO technology and techniques to be adopted by the wider microscopy community.

12.
Opt Express ; 28(11): 16749-16763, 2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32549490

RESUMO

Sensorless adaptive optics is commonly used to compensate specimen-induced aberrations in high-resolution fluorescence microscopy, but requires a bespoke approach to detect aberrations in different microscopy techniques, which hinders its widespread adoption. To overcome this limitation, we propose using wavelet analysis to quantify the loss of resolution due to the aberrations in microscope images. By examining the variations of the wavelet coefficients at different scales, we are able to establish a multi-valued image quality metric that can be successfully deployed in different microscopy techniques. To corroborate our arguments, we provide experimental verification of our method by performing aberration correction experiments in both confocal and STED microscopy using three different specimens.

13.
Opt Express ; 28(20): 29044-29053, 2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-33114810

RESUMO

Estimation of optical aberrations from volumetric intensity images is a key step in sensorless adaptive optics for 3D microscopy. Recent approaches based on deep learning promise accurate results at fast processing speeds. However, collecting ground truth microscopy data for training the network is typically very difficult or even impossible thereby limiting this approach in practice. Here, we demonstrate that neural networks trained only on simulated data yield accurate predictions for real experimental images. We validate our approach on simulated and experimental datasets acquired with two different microscopy modalities and also compare the results to non-learned methods. Additionally, we study the predictability of individual aberrations with respect to their data requirements and find that the symmetry of the wavefront plays a crucial role. Finally, we make our implementation freely available as open source software in Python.

14.
Opt Lett ; 45(24): 6599-6602, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33325849

RESUMO

Multimode optical fibers (MMFs), combined with wavefront control methods, have achieved minimally invasive in vivo imaging of neurons in deep-brain regions with diffraction-limited spatial resolution. Here, we report a method for volumetric two-photon fluorescence imaging with a MMF-based system requiring a single transmission matrix measurement. Central to this method is the use of a laser source able to generate both continuous wave light and femtosecond pulses. The chromatic dispersion of pulses generated an axially elongated excitation focus, which we used to demonstrate volumetric imaging of neurons and their dendrites in live rat brain slices through a 60 µm core MMF.


Assuntos
Hipocampo/diagnóstico por imagem , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Neurônios/citologia , Fibras Ópticas , Imagem Óptica/instrumentação , Animais , Desenho de Equipamento , Masculino , Ratos , Ratos Wistar
15.
Phys Rev Lett ; 125(11): 117401, 2020 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-32975978

RESUMO

We report the observation of a mode associated with a topological defect in the bulk of a 2D photonic material by introducing a vortex distortion to a hexagonal lattice analogous to graphene. The observed modes lie midgap at zero energy and are closely related to Majorana bound states in superconducting vortices. This is the first experimental demonstration of the Jackiw-Rossi model [R. Jackiw and P. Rossi, Nucl. Phys. B190, 681 (1981)NUPBBO0550-321310.1016/0550-3213(81)90044-4].

16.
Nano Lett ; 19(4): 2377-2383, 2019 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-30882227

RESUMO

Single photon emitters in silicon carbide (SiC) are attracting attention as quantum photonic systems ( Awschalom et al. Nat. Photonics 2018 , 12 , 516 - 527 ; Atatüre et al. Nat. Rev. Mater. 2018 , 3 , 38 - 51 ). However, to achieve scalable devices, it is essential to generate single photon emitters at desired locations on demand. Here we report the controlled creation of single silicon vacancy (VSi) centers in 4H-SiC using laser writing without any postannealing process. Due to the aberration correction in the writing apparatus and the nonannealing process, we generate single VSi centers with yields up to 30%, located within about 80 nm of the desired position in the transverse plane. We also investigated the photophysics of the laser writing VSi centers and concluded that there are about 16 photons involved in the laser writing VSi center process. Our results represent a powerful tool in the fabrication of single VSi centers in SiC for quantum technologies and provide further insights into laser writing defects in dielectric materials.

17.
Opt Express ; 27(13): 17912-17926, 2019 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-31252743

RESUMO

Liquid crystal spatial light modulators (SLMs) are usually configured and calibrated for phase modulation. However, as they are variable retarders, they also have application as polarization modulators. We show that conventional phase-only calibrations are insufficient for this purpose, and a separate retardance calibration is needed. To overcome this shortcoming we report a simple Twyman-Green interferometer-based setup to realize SLM phase and retardance calibration. For phase calibration, we identify the non-linear, spatially variant response to the drive voltage of the SLM using fringe analysis and both horizontally and vertically polarized incident light. For retardance calibration, we use incident light polarized at 45° and assess the intensity variation. The methods presented are compatible with in situ calibration of SLMs.

18.
Opt Express ; 27(16): 23378-23395, 2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31510616

RESUMO

Fluorescence correlation spectroscopy in combination with super-resolution stimulated emission depletion microscopy (STED-FCS) is a powerful tool to investigate molecular diffusion with sub-diffraction resolution. It has been of particular use for investigations of two dimensional systems like cell membranes, but has so far seen very limited applications to studies of three-dimensional diffusion. One reason for this is the extreme sensitivity of the axial (z) STED depletion pattern to optical aberrations. We present here an adaptive optics-based correction method that compensates for these aberrations and allows STED-FCS measurements in the cytoplasm of living cells.


Assuntos
Citoplasma/metabolismo , Microscopia de Fluorescência/métodos , Óptica e Fotônica , Espectrometria de Fluorescência/métodos , Sobrevivência Celular , Difusão , Humanos , Soluções
19.
Opt Express ; 27(24): 35797-35810, 2019 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-31878746

RESUMO

We present a scheme for active compensation of complex extrinsic polarization perturbations introduced into an optical system. Imaging polarimeter is used to measure the polarization state across a beam profile and a liquid crystal spatial light modulator controls the polarization of the input beam. A sequence of measurements permits determination of the birefringence properties of a perturbing specimen. The necessary correction is calculated and fed back to the polarization modulator to compensate for the polarization perturbation. The system capabilities are demonstrated on a range of birefringent specimens.

20.
Opt Express ; 27(11): 15184-15193, 2019 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-31163718

RESUMO

We present here the first time-resolved tilt-angle and retardance measurements for large-tilt (>45°) flexoelectro-optic liquid crystal modulators. These devices have potential for next generation fast switching (>1 kHz), 0-2π analog phase spatial light modulators (SLMs), with applications in optical beamsteering, microscopy and micromachining. The chiral nematic device used consisted of a mixture of CBC7CB and the chiral dopant R5011 in a nominally 5 µm-thick cell, aligned in the uniform lying helix mode. As the device is dynamically switched over angles of ± 54°, retardance changes of up to 0.17λ are observed. Furthermore, the time-resolved measurements reveal an asymmetry in the tilt in the optic-axis depending on the polarity of the applied electric field. The change in the optic-axis exhibits a pattern dependence, whereby it is determined by both the pulse history and the applied field. This pattern dependence results in tilt-angle errors of up to 8.8°, which could manifest as phase errors as large as 35.2° in potential SLMs. These time domain measurements may allow correction of these deterministic errors, to realize practical devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA