Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
World J Radiol ; 5(1): 20-4, 2013 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-23494012

RESUMO

We report an unusual case of spontaneous ovarian hyperstimulation syndrome and pituitary hyperplasia mimicking macroadenoma in an adult, non-pregnant woman. Her condition was triggered by unrecognized primary hypothyroidism, which regressed after thyroid hormone replacement therapy. This case highlights the need for clinicians and radiologists to familiarize themselves with the clinical and imaging features detected in case of these complications of primary hypothyroidism, which are not well known in the medical and radiological profession. Such improved knowledge will help avoid delays in diagnosis, progression to life-threatening complications, and unnecessary surgery.

2.
Int J Cardiovasc Imaging ; 25(5): 519-27, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19288259

RESUMO

Cardiovascular magnetic resonance (CMR) very early after primary percutaneous coronary intervention (PPCI) may lead to instability or early stent complications. However, CMR in the hyperacute phase of STEMI may improve risk stratification. We investigated feasibility and safety of CMR in the hyperacute phase of STEMI immediately after PPCI. One hundred and twenty eight consecutive patients immediately after PPCI for STEMI. Sixty four underwent CMR <12 h after PPCI versus 64 matched controls. Outcomes were followed over 6 months. CMR in hyperacute STEMI was not associated with in-hospital death, infarct expansion, or urgent revascularization (P = NS). CMR (32 ml gadolinium contrast) immediately after PPCI (180 ml iodine contrast) did not increase nephropathy. CMR did not increase major adverse cardiac events (5 vs. 8%, P = 0.16) or recurrence of angina (6 vs. 8%, P = 0.73) at 6 months. CMR immediately after PPCI is feasible and safe, allowing very early risk stratification in STEMI.


Assuntos
Angioplastia Coronária com Balão , Meios de Contraste , Gadolínio DTPA , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/mortalidade , Estudos de Casos e Controles , Meios de Contraste/efeitos adversos , Angiografia Coronária , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Gadolínio DTPA/efeitos adversos , Humanos , Iohexol , Estimativa de Kaplan-Meier , Imagem Cinética por Ressonância Magnética/efeitos adversos , Imagem Cinética por Ressonância Magnética/mortalidade , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Ácidos Tri-Iodobenzoicos
3.
Int J Cardiovasc Imaging ; 23(6): 771-80, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17216125

RESUMO

OBJECTIVES: To evaluate CT coronary angiography (CTA) when compared with catheter coronary angiography (CCA), for the detection of coronary artery stenoses and rate of optimal coronary artery segment visualization. METHOD: Retrospective, two-center study enrolling 26 patients who underwent CCA and ECG-gated 16-detector CTA (slice thickness 0.6 mm; rotation 500 ms). RESULTS AND CONCLUSION: 283 segments were available for postprocessing. Sensitivity, specificity, and positive predictive value were, respectively, 80, 100, and 100%, for detecting more than 50% luminal stenoses, when optimally visualized segments were considered, in comparison to CCA. Negative predictive value was excellent (98%). Rate of non-optimally visualized coronary segments was 26%. Most clinical benefits of coronary CT angiography should probably be obtained when it is performed to exclude significant stenoses on selected populations of patients with a low pre-test probability of severe coronary artery disease, and under optimal conditions of controlled heart rate and minimal presence of calcium.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Cateterismo Cardíaco , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol , Masculino , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Can Assoc Radiol J ; 58(2): 92-108, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17521054

RESUMO

Multidetector-row electrocardiogram (ECG)-gated cardiac computed tomography (CT) will probably be a major noninvasive imaging option in the near future. Recent developments indicate that this new technology is improving rapidly. This article presents an overview of the current concepts, perspectives, and technical capabilities in coronary CT angiography (CTA). We have reviewed the recent literature on the different applications of this technology; of particular note are the many studies that have demonstrated the high negative predictive value (NPV) of coronary CTA, when performed under optimal conditions, for significant stenoses in native coronary arteries. This new technology's level of performance allows it to be used to evaluate the presence of calcified plaques, coronary bypass graft patency, and the origin and course of congenital coronary anomalies. Despite a high NPV, the robustness of the technology is limited by arrhythmias, the requirement of low heart rates, and calcium-related artifacts. Some improvements are needed in the imaging of coronary stents, especially the smaller stents, and in the detection and characterization of noncalcified plaques. Further studies are needed to more precisely determine the role of CTA in various symptomatic and asymptomatic patient groups. Clinical testing of 64-slice scanners has recently begun. As the technology improves, so does the spatial and temporal resolution. To date, this is being achieved through the development of systems with an increased number of detectors and shorter gantry rotation time, as well as the development of systems equipped with 2 X-ray tubes and the eventual development of flat-panel technology. Thus further improvement of image quality is expected.


Assuntos
Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Calcinose/diagnóstico por imagem , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Anomalias dos Vasos Coronários/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tecnologia Radiológica , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA