Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Endocrinol Invest ; 47(6): 1505-1511, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38129742

RESUMO

PURPOSE: Serum calcium/phosphate ratio (Ca/P) has been recently proposed as an additional tool to identify primary hyperparathyroidism (PHPT), especially in patients with subclinical presentation, with a proposed cut-off of 3.3 when both values are expressed in mg/dL. No data are available on the relationship between Ca/P and the clinical presentation of PHPT. We thus evaluated this relationship in a large, single-center, unselected series. METHODS: 515 consecutive PHPT patients (mean age 65 ± 13.15 years, 77.1% females) were retrospectively evaluated at diagnosis. RESULTS: Mean Ca/P was 4.54 ± 1.5 (range 2.36-13.9), being higher than 3.3 in 88.5% of patients. Ca/P was significantly higher in (1) males, (2) symptomatic PHPT, (3) patients with 25-hydroxy vitamin D levels lower than 20 µg/L, (4) patients with osteitis fibrosa cystica, (5) patients with T score < - 2.5 at the radial site. In a multivariate regression analysis, Ca/P resulted significantly associated with PTH levels. After the exclusion of 57 patients with asymptomatic PHPT (aPHPT) patients and serum Ca higher than 1 mg/dL above the upper limit of normal range, no differences were found in Ca/P between aPHPT meeting or not surgical criteria. CONCLUSIONS: In PHPT Ca/P ratio is associated with increased biochemical and clinical severity of disease and represents a direct indicator of clinical bone damage. However, it does not seem an additional tool to identify aPHPT patients reaching surgical indication.


Assuntos
Cálcio , Hiperparatireoidismo Primário , Fosfatos , Humanos , Hiperparatireoidismo Primário/sangue , Hiperparatireoidismo Primário/diagnóstico , Hiperparatireoidismo Primário/cirurgia , Feminino , Masculino , Idoso , Cálcio/sangue , Estudos Retrospectivos , Pessoa de Meia-Idade , Fosfatos/sangue , Biomarcadores/sangue , Doenças Assintomáticas/terapia , Hormônio Paratireóideo/sangue
2.
J Diabetes Metab Disord ; 17(2): 393-399, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30918874

RESUMO

OBJECTIVE: To evaluate the basal/total ratio of daily insulin dose (b/T) in outpatients with diabetes type 1 (DM1) and type 2 (DM2) on basal-bolus regimen, by investigating whether there is a relationship with HbA1c and episodes of hypoglycemia. METHODS: Multicentric, observational, cross-sectional study in Italy. Adult DM1 (n = 476) and DM2 (n = 541) outpatients, with eGFR >30 mL/min/1.73 m2, on a basal-bolus regimen for at least six months, were recruited from 31 Italian Diabetes services between March and September 2016. Clinicaltrials.govID: NCT03489031. RESULTS: Total daily insulin dose was significantly higher in DM2 patients (52.3 ± 22.5 vs. 46 ± 20.9 U/day), but this difference disappeared when insulin doses were normalized for body weight. The b/T ratio was lower than 0.50 in both groups: 0.46 ± 0.14 in DM1 and 0.43 ± 0.15 in DM2 patients (p = 0.0011). The b/T was significantly higher in the patients taking metformin in both groups, and significantly different according to the type of basal insulin (Degludec, 0.48 in DM1 and 0.44 in DM2; Glargine, 0.44 in DM1 and 0.43 in DM2; Detemir, 0.45 in DM1 and 0.39 in DM2). The b/T ratio was not correlated in either group to HbA1c or incidence of hypoglycemia (<40 mg/dL, or requiring caregiver intervention, in the last three months). In the multivariate analysis, metformin use and age were independent predictors of the b/T ratio in both DM1 and DM2 patients, while the type of basal insulin was an independent predictor only in DM1. CONCLUSION: The b/T ratio was independent of glycemic control and incidence of hypoglycemia.

4.
Phys Med Biol ; 51(3): 485-95, 2006 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-16424577

RESUMO

We present a quick and easy method for the calibration of a matrix of sensors. The algorithm is based on a three-step irradiation procedure which relies only on the constancy of the delivered fluence at each step. With this method the gain of each sensor is derived relative to a reference detector. The algorithm has been applied to a matrix of (32 x 32) ionization chambers. After the calibration coefficients have been applied, by comparing the response of the matrix of chambers to a reference detector over a large field, we determined that the fluence measurement of individual chambers is better than 0.7%. The algorithm solves the cumbersome problem of the relative gain calibration of a matrix of a large number of sensors.


Assuntos
Radioterapia de Intensidade Modulada/métodos , Algoritmos , Calibragem , Modelos Estatísticos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação , Reprodutibilidade dos Testes , Transdutores , Água
5.
Phys Med Biol ; 50(19): 4681-94, 2005 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-16177497

RESUMO

Dynamic intensity-modulated radiotherapy (D-IMRT) using the sliding-window technique is currently applied for selected treatments of head and neck cancer at Institute for Cancer Research and Treatment of Candiolo (Turin, Italy). In the present work, a PiXel-segmented ionization Chamber (PXC) has been used for the verification of 19 fields used for four different head and neck cancers. The device consists of a 32x32 matrix of 1024 parallel-plate ionization chambers arranged in a square of 24x24 cm2 area. Each chamber has 0.4 cm diameter and 0.55 cm height; a distance of 0.75 cm separates the centre of adjacent chambers. The sensitive volume of each single ionization chamber is 0.07 cm3. Each of the 1024 independent ionization chambers is read out with a custom microelectronics chip.The output factors in water obtained with the PXC at a depth of 10 cm were compared to other detectors and the maximum difference was 1.9% for field sizes down to 3x3 cm2. Beam profiles for different field dimensions were measured with the PXC and two other types of ionization chambers; the maximum distance to agreement (DTA) in the 20-80% penumbra region of a 3x3 cm2 field was 0.09 cm. The leaf speed of the multileaf collimator was varied between 0.07 and 2 cm s-1 and the detector response was constant to better than 0.6%. The behaviour of the PXC was measured while varying the dose rate between 0.21 and 1.21 Gy min-1; the mean difference was 0.50% and the maximum difference was 0.96%. Using fields obtained with an enhanced dynamic wedge and a staircase-like (step) IMRT field, the PXC has been tested for simple 1D modulated beams; comparison with film gave a maximum DTA of 0.12 cm. The PXC was then used to check four different IMRT plans for head and neck cancer treatment: cervical chordoma, parotid, ethmoid and skull base. In the comparison of the PXC versus film and PXC versus treatment planning system, the number of pixels with gamma parameter

Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador , Cordoma/radioterapia , Osso Etmoide/patologia , Humanos , Neoplasias Parotídeas/radioterapia , Crânio/patologia , Filme para Raios X , Ecrans Intensificadores para Raios X
6.
Med Phys ; 31(2): 414-20, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15000628

RESUMO

A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is 0.07 cm3. The purpose of the detector is to ease the two-dimensional (2D) verifications of fields with complex shapes and large gradients. The detector was characterized in a PMMA phantom using 60Co and 6 MV x-ray photon beams. It has shown good signal linearity with respect to dose and dose rate to water. The average sensitivity of a single ionization chamber was 2.1 nC/Gy, constant within 0.5% over one month of daily measurements. Charge collection efficiency was 0.985 at the operating polarization voltage of 400 V and 3.5 Gy/min dose rate. Tissue maximum ratio and output factor have been compared with a Farmer ionization chamber and were found in good agreement. The dose profiles have been compared with the ones obtained with an ionization chamber in water phantom for the field sizes supplied by a 3D-Line dynamic multileaf collimator. These results show that this detector can be used for 2D dosimetry of x-ray photon beams, supplying a good spatial resolution and sensibly reducing the time spent in dosimetric verification of complex radiation fields.


Assuntos
Radiometria/métodos , Algoritmos , Radioisótopos de Cobalto , Elétrons , Humanos , Processamento de Imagem Assistida por Computador , Íons , Imagens de Fantasmas , Fótons , Radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional , Software , Água , Raios X
7.
Phys Med Biol ; 49(16): 3713-24, 2004 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-15446800

RESUMO

Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with water-equivalent slabs. The parallel plate ionization chambers have a sensitive area of 24 x 24 cm2, and consist of 0.375 cm wide and 24 cm long strips. There are a total of 64 strips per chamber. The Magic Cube has been tested with the clinical proton beam at Loma Linda University Medical Centre (LLUMC), and was shown to be capable of fast and precise quasi-3D dose verification. The Pixel Ionization Chamber (PXC) is a detector with pixel anode segmentation. It is a 32 x 32 matrix of 1024 cylindrical ionization cells arranged in a square 24 x 24 cm2 area. Each cell has 0.4 cm diameter and 0.55 cm height, at a pitch of 0.75 cm separates the centre of adjacent cells. The sensitive volume of each single ionization cell is 0.07 cm3. The detectors are read out using custom designed front-end microelectronics and a personal computer-based data acquisition system. The PXC has been used to verify dynamic intensity-modulated radiotherapy for head-and-neck and breast cancers.


Assuntos
Fótons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Calibragem , Elétrons , Humanos , Íons , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Prótons , Doses de Radiação , Dosagem Radioterapêutica , Radioterapia Conformacional/instrumentação , Radioterapia de Alta Energia , Fatores de Tempo
8.
Phys Med ; 27(4): 233-40, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21074468

RESUMO

A detector (MOPI) has been developed for the online monitoring of the beam at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA), where shallow tumours of the ocular region are treated with 62 MeV protons. At CATANA the beam is passively spread to match the tumour shape. The uniformity of the delivered dose depends on beam geometrical quantities which are checked before each treatment. However, beam instabilities might develop during the irradiation affecting the dose distribution. This paper reports on the use of the MOPI detector to measure the stability of the beam profile during the irradiation in the clinical practice. The results obtained in the treatment of 54 patients are also presented.


Assuntos
Oftalmopatias/radioterapia , Laboratórios , Terapia com Prótons , Radioterapia Assistida por Computador/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA