Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(7): 1125-1137, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639140

RESUMO

BACKGROUND: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. AIMS: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. METHODS: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. RESULTS: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. CONCLUSION: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.


Assuntos
Cateterismo Periférico , Artéria Femoral , Técnicas Hemostáticas , Punções , Técnicas de Sutura , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Artéria Femoral/diagnóstico por imagem , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Idoso , Técnicas Hemostáticas/instrumentação , Técnicas Hemostáticas/efeitos adversos , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Fatores de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Itália , Desenho de Equipamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Hemorragia/etiologia , Hemorragia/prevenção & controle
2.
Echocardiography ; 41(1): e15724, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064288

RESUMO

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Assuntos
Fibrilação Atrial , Comunicação Interatrial , Humanos , Adulto , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Fluoroscopia , Resultado do Tratamento
3.
Curr Atheroscler Rep ; 22(5): 17, 2020 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-32451750

RESUMO

PURPOSE OF REVIEW: To summarize epidemiology, pathophysiology, prognostic relevance, and treatment options of coronary artery disease (CAD) when coupled with severe aortic stenosis (SAS). In regard to treatment options, we focused on the most recently adopted therapeutic approaches and on the future perspectives in light of the latest percutaneous and surgical technical improvements in the field of both CAD and SAS management. RECENT FINDINGS: Nowadays, SAS is the most common valve disease requiring intervention, either surgical or percutaneous. On the other side, CAD is one of the leading causes of death in the developed countries. CAD and degenerative SAS share several predisposing factors and are often concurrently found in clinical practice. Despite in the last years the transcatheter aortic valve replacement (TAVR) has been deeply changing the therapeutic approach to SAS, the correct management of patients with concomitant CAD remains controversial due to limited and heterogeneous data in the literature. Coronary revascularization is often performed in patients with concomitant CAD and SAS. Complete surgical approach is still the standard of care according to international guidelines. However, in light of the recent results of TAVR trials, the therapeutic approach is expected to change. To date, percutaneous coronary intervention performed before TAVR is safe and feasible even if the optimal timing for revascularization remains debated. Due to the great complexity of the patients affected by SAS and CAD and until unquestionable truths will come from large randomized trials, the role of the Heart Team in the decision-making process is of primary importance to guarantee the best tailored therapeutic strategy for the single patient.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/etiologia , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 93(4): 592-601, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30269413

RESUMO

OBJECTIVES: The aim of this observational study was to determine the benefits of the novel, orally delivered P2Y12 -inhibitors (Is) in terms of angiographic endpoints and in relation to the time of the loading dose (LD) administration. BACKGROUND: The goal of ST-elevation myocardial infarction (STEMI) treatment is timely reperfusion. The P2Y12 -Is prasugrel and ticagrelor have improved the angiographic outcome of primary percutaneous coronary intervention (pPCI) and patients' prognosis. However, their onset of action is impaired in STEMI and delayed by their oral administration. METHODS: The 328 eligible patients with STEMI consecutively referred for pPCI were divided into three groups depending on the interval of "P2Y12 -I LD administration-to-balloon time": Group 2 included patients that received P2Y12 -I LD at least 60 min prior to pPCI, Group 1 within 60 min prior to pPCI, and Group 0 at the moment of pPCI. Angiographic, clinical, and biochemical parameters were evaluated. Pre- and post-pPCI TIMI flow grade (TFG) and ST resolution (STR) were used as outcome measures to determine efficacy and optimal timing of pretreatment. RESULTS: Pre-pPCI TFG improved with increasing P2Y12 -I LD administration-to-balloon time; pre-PCI TFG 0/1 was 74.5% in Group 0, 65.5% in Group 1 and 54.9% in Group 2 (P < 0.002). Post-pPCI TFG 3 results also differed significantly between the three groups: 85.2% in Group 0, 88.1% in Group 1, 97.6% in Group 2 (P < 0.013). ST resolution rates were also positively associated with longer pretreatment intervals. CONCLUSIONS: This observational study suggests that the angiographic benefit of P2Y12 -I administration is time-dependent: longer pretreatment improves coronary reperfusion in terms of pre- and post-pPCI TFG and STR.


Assuntos
Plaquetas/efeitos dos fármacos , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Cloridrato de Prasugrel/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Receptores Purinérgicos P2Y12/efeitos dos fármacos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Ticagrelor/administração & dosagem , Administração Oral , Idoso , Plaquetas/metabolismo , Angiografia Coronária , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Cloridrato de Prasugrel/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Receptores Purinérgicos P2Y12/sangue , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Ticagrelor/efeitos adversos , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento
5.
Heart Vessels ; 34(9): 1499-1508, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30895384

RESUMO

Percutaneous closure of atrial septal defect (ASD)/patent foramen ovale (PFO) can influence systemic hemodynamics. The aim of this research was to evaluate the influence of the closure procedure on morphological and functional characteristics of systemic vascular walls. Fourteen ASD (mean age 40 ± 16 years) and 14 PFO (45 ± 8 years) patients were enrolled in this retrospective study. All underwent percutaneous closure procedure; physical, clinical and biochemical evaluations; echocardiography; carotid evaluation; and brachial artery flow-mediated vasodilatation (FMD). All the evaluations were performed at the time of enrollment, 24 h post-procedure, at 1-6-12-month follow-up. FMD at enrollment was higher in PFO patients as compared to ASD (8.5% [7.6-10.7%] versus 6.5% [5.6-7.6%], p < 0.0001). FMD values in ASD patients significantly increased during follow-up (enrollment: 6.5% [5.6-7.6%], 12-month follow-up: 8.8% [7.2-10.3%], p < 0.01). PFO patients showed reduced FMD values 24 h after the procedure (enrollment: 8.5% [7.6-10.7%], 24 h post-procedure: 7% [6.3-9%], p < 0.001), while recovering endothelial function during follow-up period to baseline values (FMD at 12-month follow-up: 8.2% [7.6-10.5%]). At one-year follow-up, FMD remained inversely related to systolic pulmonary arterial pressure and right and left atrial/ventricle chambers dimensions (RV proximal diameter efflux tract, right atrium [RA] longitudinal diameter, RA transverse diameter, RA area, left ventricle [LV] end-diastolic diameter, left atrium [LA] anteroposterior diameter, LA area; p < 0.01) in ASD patients. Endothelial function improved after percutaneous closure of ASD, while remaining stable after PFO closure. Therefore, ASD patients seem to improve their cardiovascular risk profile after percutaneous closure of their defect.


Assuntos
Cateterismo Cardíaco/métodos , Forame Oval Patente/cirurgia , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal , Adulto , Ecocardiografia , Feminino , Forame Oval Patente/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
Europace ; 20(1): 116-123, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339584

RESUMO

Aims: Preliminary data on Sapien 3 valve (S3-THV) use for transcatheter aortic valve implantation have shown an increased permanent pacemaker implantation (PPMI) rate with respect to Sapien XT valve. Aim of this study was to investigate the role of S3-THV position in the left ventricular outflow tract (LVOT) on electrocardiographic changes suggestive of atrioventricular (ΔPR) and/or intraventricular (ΔQRS) conduction abnormalities and 30 days PPMI rate. Methods and results: Eighty-six consecutive patients treated with S3-THV were included in the study. All patients underwent clinical and electrocardiogram evaluation. Left ventricular outflow tract prosthesis depth was assessed by fluoroscopy and expressed quantitatively (mm) and as aorto-ventricular ratio (AVR). Eight patients (9.3%) needed PPMI at 30 days. A low AVR (≤60/40) predicted PPMI (OR = 6.09, 95% CI 1.19-31.01, P = 0.030) and resulted into higher PPMI rate, compared with higher AVR (30.0 vs. 6.6%, P = 0.017). For each millimetre increase in the LVOT prosthesis depth PPMI risk increased by 1.41 times (95% CI 1.06-1.87, P = 0.017). In patients with low AVR, ΔPR was higher than in those with higher AVR (33.4 ± 56.7 vs. 12.1 ± 19.4 ms, P = 0.021) and ΔPR was associated to LVOT prosthesis depth (ß = 0.286, P = 0.009). Furthermore, ΔPR was associated with risk of PPMI (OR = 1.03, 95% CI 1.01-1.06, P = 0.024). Conclusions: A low AVR is associated to higher ΔPR and PPMI rates. The correlation between LVOT prosthesis depth with ΔPR and higher PPMI rate suggests the need of a careful S3-THV implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/transplante , Arritmias Cardíacas/etiologia , Valvuloplastia com Balão/efeitos adversos , Frequência Cardíaca , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Distribuição de Qui-Quadrado , Eletrocardiografia , Feminino , Humanos , Itália , Modelos Lineares , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Marca-Passo Artificial , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
7.
Heart Vessels ; 33(3): 291-298, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29027587

RESUMO

Takotsubo cardiomyopathy (TTC) is characterized by transient systolic ventricular dysfunction. It is supposed to be caused by a cathecolaminergic wave which leads to myocardial stunning through a massive action on beta2-adrenoreceptor. Moreover, beta2-receptor hyperactivity negatively influences endothelial function. It can be detected by brachial flow mediated dilation (b-FMD) which assesses endothelium regulated vasomotility. The study aim is to analyze the b-FMD variability during hospitalization in 50 patients admitted with TTC. In addition, we investigated a possible correlation between b-FMD at admission and both length of hospital stay (LOHS) and troponin I peak. We detected b-FMD by measuring the hypoxic induced vasoreactivity through assessing brachial artery dilation after 5 min of iatrogenic ischemia obtained by inflating a sphygmomanometer cuff. Artery diameter modifications were assessed by high-resolution ultrasound, and a dedicated software calculated accurately the percentage of dilation after ischemia by comparing it to the basal. These values were measured at admission and on discharge. The obtained values were compared for each patient to explore their variability during hospitalization. Moreover, the correlation between the b-FMD at admission and both the troponin I peak and the LOHS was investigated. There was a statistical significant difference between mean FMD measured at admission and at discharge (respectively 1.54 ± 0.34 and 8.92 ± 2.48%; p < 0.001). Moreover, we found a significant negative correlation between troponin I peak and FMD values at admission (r = - 0.7645; p < 0.001) and a significant inverse correlation between FMD at admission and LOHS (r = - 0.7543; p < 0.001). There is a significant improvement of b-FMD during hospitalization in patients admitted for Tako-Tsubo Cardiomyopathy. Moreover, for the first time, a direct correlation among b-FMD, troponin I peak and LOHS has been detected.


Assuntos
Artéria Braquial/fisiopatologia , Endotélio Vascular/fisiopatologia , Miocárdio/metabolismo , Cardiomiopatia de Takotsubo/fisiopatologia , Troponina I/metabolismo , Vasodilatação/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/metabolismo , Ultrassonografia
8.
Ann Intern Med ; 167(2): 103-111, 2017 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-28632280

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) have a role in preventing cardiac arrest in patients at risk for life-threatening ventricular arrhythmias. PURPOSE: To compare ICD therapy with conventional care for the primary prevention of death of various causes in adults with ischemic or nonischemic cardiomyopathy. DATA SOURCES: MEDLINE, Cochrane Central Register of Controlled Trials, Google Scholar, and EMBASE databases, as well as several Web sites, from 1 April 1976 through 31 March 2017. STUDY SELECTION: Randomized controlled trials, published in any language, comparing ICD therapy with conventional care and reporting mortality outcomes (all-cause, sudden, any cardiac, or noncardiac) in the primary prevention setting. DATA EXTRACTION: 2 independent investigators extracted study data and assessed risk of bias. DATA SYNTHESIS: Included were 11 trials involving 8716 patients: 4 (1781 patients) addressed nonischemic cardiomyopathy, 6 (4414 patients) ischemic cardiomyopathy, and 1 (2521 patients) both types of cardiomyopathy. Mean follow-up was 3.2 years. An overall reduction in all-cause mortality, from 28.26% with conventional care to 21.37% with ICD therapy (hazard ratio [HR], 0.81 [95% CI, 0.70 to 0.94]; P = 0.043), was found. The magnitude of reduction was similar in the cohorts with nonischemic (HR, 0.81 [CI, 0.72 to 0.91]) and ischemic (HR, 0.82 [CI, 0.63 to 1.06]) disease, although the latter estimate did not reach statistical significance. The rate of sudden death fell from 12.15% with conventional care to 4.39% with ICD therapy (HR, 0.41 [CI, 0.30 to 0.56]), with a similar magnitude of reduction in patients with ischemic (HR, 0.39 [CI, 0.23 to 0.68]) and those with nonischemic disease (HR, 0.44 [CI, 0.17 to 1.12]). Noncardiac and any cardiac deaths did not differ significantly by treatment. LIMITATION: Heterogeneous timing of ICD placement; heterogeneous pharmacologic and resynchronization co-interventions; trials conducted in different eras; adverse events and complications not reviewed. CONCLUSION: Overall, primary prevention with ICD therapy versus conventional care reduced the incidence of sudden and all-cause death. PRIMARY FUNDING SOURCE: None.


Assuntos
Arritmias Cardíacas/prevenção & controle , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Isquemia Miocárdica/terapia , Prevenção Primária , Arritmias Cardíacas/etiologia , Cardiomiopatias/complicações , Morte Súbita/prevenção & controle , Humanos , Isquemia Miocárdica/complicações
9.
Surg Technol Int ; 32: 219-223, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29791706

RESUMO

Cryptogenic stroke is the final diagnosis in almost 40% of ischemic acute cerebrovascular events. There is currently no definitive clinical evidence that percutaneous closure of patent foramen ovale (PFO) can prevent the recurrence of stroke or transient ischemic attack (TIA). Identification of the causes of neurologic ischemic syndromes is essential for any strategy intended to prevent the catastrophic consequences of cerebral infarction. Since the initial reports of an unexpectedly high prevalence of PFO in younger patients with cryptogenic stroke in 1988, there has been growing interest and experience in diagnosing and treating these patients, both medically and/or with percutaneous closure, in particular for the potential to eliminate paradoxical embolism via PFO, which is a likely mechanism for stroke in these patients. Selection of the appropriate occluder device is of paramount importance for the success of the procedure. While devices like the Amplatzer™ PFO Occluder (St. Jude Medical), which, based on the extended follow-up of the RESPECT Trial, was approved by the U.S. Food and Drug Administration last year for recurrent stroke prevention, have become generally accepted as being better than medical therapy for patients needing treatment, concerns remain regarding device- and procedure-related complications. NobleStitch™ EL is a novel device that offers a simple non-prosthetic implant method of PFO closure without the inherent risks seen with septal occluders: no risk of device embolization, device thrombosis or late erosion, and probably no risk of arrhythmia. Futhermore, there is no material that would hinder future access to the left atrium and no requirement for anti-coagulation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Forame Oval Patente/cirurgia , Técnicas de Sutura/instrumentação , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Embolia Paradoxal/prevenção & controle , Desenho de Equipamento , Humanos , Ataque Isquêmico Transitório/prevenção & controle , Recidiva , Acidente Vascular Cerebral/prevenção & controle , Suturas
10.
Surg Technol Int ; 32: 201-207, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29791711

RESUMO

Mitral regurgitation (MR) is the most prevalent valvular heart disease (VHD) and represents an important cause of heart failure. Medical therapy has a limited role in improving symptoms and does not hinder the progression of valvular disease. Surgery is the treatment of choice for severe symptomatic MR; valve repair is currently the preferred surgical approach because it reduces peri-operative mortality and ensures a good medium- to long-term survival outcome. Nevertheless, a non-negligible proportion of patients with indications for surgical correction are considered to be at prohibitive perioperative risk, mainly because of old age and multiple comorbidities. The introduction of percutaneous interventions to clinical practice has changed the natural history of this population. Percutaneous edge-to-edge transcatheter mitral valve repair (Mitraclip®, Abbott Vascular, Menlo Park, CA) is a state-of-the-art therapy for approaching MR in patients with a high surgical risk. Despite having been only recently introduced, this transvenous transfemoral percutaneous intervention has already been performed in more than 40,000 subjects worldwide, with reassuring post-operative results in terms of safety, feasibility, mortality and morbidity. Since Mitraclip® is considered to be minimally invasive, it is currently indicated in "frail" patients with severe comorbidities. We provide a critical review of the literature to clarify current indications, procedural details, patient selection criteria, and future perspectives for this innovative technique.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos
11.
BMC Cardiovasc Disord ; 17(1): 259, 2017 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-29017461

RESUMO

BACKGROUND: There is an increasing trend towards shorter hospital stays after transcatheter aortic valve implantation (TAVI), in particular for patients undergoing the procedure via transfemoral (TF) access. Preliminary data suggest that there exists a population of patients that can be discharged safely very early after TF-TAVI. However, current evidence is limited to few retrospective studies, encompassing relatively small sample sizes. METHODS: The Feasibility And Safety of early discharge after Transfemoral TAVI (FAST-TAVI) registry is a prospective observational registry that will be conducted at 10 sites across Italy, the Netherlands and the UK. Patients will be included if they have been scheduled to undergo TF-TAVI with the balloon-expandable SAPIEN 3 transcatheter heart valve (THV; Edwards Lifesciences, Irvine, CA). The primary endpoint is a composite of all-cause mortality, vascular-access-related complications, permanent pacemaker implantation, stroke, re-hospitalisation due to cardiac reasons, kidney failure and major bleeding, occurring during the first 30 days after hospital discharge. Patients will be stratified according to whether they were high or low risk for early discharge (≤3 days) (following pre-specified criteria), and according to whether or not they were discharged early. Secondary endpoints will include time-to-event (Kaplan-Meier) analysis for the primary outcome and its individual components, analysis of the relative costs of early and late discharge, and changes in short- and long-term quality of life. Multivariate logistic regression will be used to identify factors that indicate that a patient may be suitable for early discharge. DISCUSSION: The data gathered in the FAST-TAVI registry should help to clarify the safety of early discharge after TF-TAVI and to identify patient and procedural characteristics that make early discharge from hospital a safe and cost-effective strategy. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02404467 (registration first received March 23rd 2015).


Assuntos
Artéria Femoral/cirurgia , Alta do Paciente/normas , Complicações Pós-Operatórias/prevenção & controle , Sistema de Registros/normas , Substituição da Valva Aórtica Transcateter/normas , Estudos de Viabilidade , Humanos , Itália/epidemiologia , Países Baixos/epidemiologia , Alta do Paciente/tendências , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Reino Unido/epidemiologia
12.
Surg Technol Int ; 29: 201-206, 2016 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-27466865

RESUMO

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) technique represents a real revolution in the field of interventional cardiology and medicine, in particular for the treatment of severe aortic valve stenosis in elderly patients or in patients when the periprocedural risk for the traditional surgical option is considered too high, as an alternative to the traditional aortic valve replacement. Although experience on the valves of the last generation is still limited in terms of time, the data currently available are definitely moving in the direction of a minimum hospital mortality (1%) as well as a drastic reduction in the incidence of complications when compared to the devices of the previous generation. Finally, the evolution of specified materials of the newest generation have greatly enhanced safety and efficacy of TAVI procedures in the last years. In order to ensure the selection of the most appropriate valve and the success of the procedure, the role of cardiac imaging (computed tomography scan evaluation and angiography) is crucial. These examinations require the use of contrast medium in patients suffering from renal dysfunction at the baseline. The need for fluoroscopy and angiography using contrast agents to aid positioning of the valve may lead to contrast-induced nephropathy (CIN) as one form or one etiology of acute kidney injury (AKI), which is associated with increased morbidity and mortality. The aim of our study is to investigate the accuracy of intravascular ultrasound (IVUS-a technique which does not need contrast) for the assessment of native valve measures in patients undergoing TAVI by comparing values obtained with IVUS to those ones previously obtained in the same patients with computed tomography (CT) scans. MATERIAL AND METHODS: We enrolled 25 consecutive patients (10 males, average age 81.3±5,1 years) who underwent TAVI with femoral access in our Cardiac Surgery Cath-Lab (University of Bari) from January to October 2015 (Logistic EuroSCORE 21.6±15.4%; STS score mortality 20.9±14.9%). Each patient scheduled for TAVI underwent coronary angiography and high resolution angio-CT in order to obtain a complete evaluation (diameters, perimeters, and areas at annulus level, -3mm level, +15mm level, height of coronary ostia, shape, and conformation of left ventricle outflow tract, conformation, and calcifications of aortic and ileo-femoral axis) to choose the most suitable prosthetic aortic valve for each patient. In all patients, during the procedure (before the prosthetic valve implantation), we executed a manual IVUS pullback (from left ventricle outflow tract to ascending aorta) by using a 7F IVUS probe (Volcano Corporation, San Diego, CA). On the recorded IVUS pullback, a second operator (who did not know the values obtained by CT measurements) identified the aortic annulus and, at this level, measured: minimum and maximum diameter; perimeter; derived perimeter, and area. The t-student test has been used to compare the averages of these IVUS values to the CT ones. A p value< 0.05 was considered as statistically significant. RESULTS: Independently from the kind and size of implanted prosthetic valve, no statistical differences were found when the averages of all considered parameters (obtained both with CT and IVUS) were compared. The following are the results obtained: minimum diameter (CT: 19,62mm±1,10 vs. IVUS: 19,55mm±1,40; p=0.41); maximum diameter (CT: 24,73mm±2,42 vs. IVUS: 25,9mm±1,80; p=0.08); perimeter (CT: 72,05mm±4,36 vs. IVUS: 73,32mm±6,09; p=0.164); derived perimeter (CT: 22,94mm±1,40 vs. IVUS: 23,32mm ± 1,95; p=0,198); and area (CT: 3,99cm2 ±0,97 vs. IVUS: 4,06 cm2 ± 0,47; p=0,073) (Figs. 1-3). CONCLUSIONS: These preliminary data suggest accurate IVUS measures when compared to CT in the evaluation of valve parameters considered (minimum and maximum diameters, area, perimeter, and derived perimeter at the annulus level). In order to confirm these findings and to give them statistical significance, it will be necessary to increase the sample size.


Assuntos
Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Resultado do Tratamento , Ultrassonografia
13.
Ann Vasc Surg ; 29(2): 361.e9-361.e12, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25462550

RESUMO

To report the use of endografts to manage multiple aneurysms due to Cogan syndrome (CS). A 38-year-old woman with descending thoracic aorta and right common carotid artery aneurysms due to CS was treated with endovascular grafts. After 4 years, angio computed tomography scan demonstrated complete exclusion of the aneurysms with no signs of endoleak, whereas echo color Doppler showed patency of the carotid graft, no signs of restenosis, no progression of the disease in the landing zones, and complete aneurysm exclusion. Endovascular repair seems to have favorable long-term outcomes and should be considered a viable alternative to surgery in unfit for open surgery patients, even if they are young, and when the aneurysm size and location would pose a higher risk of perioperative and postoperative complications after an open surgical procedure.


Assuntos
Aneurisma/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Doenças das Artérias Carótidas/cirurgia , Síndrome de Cogan/complicações , Adulto , Aneurisma/etiologia , Aneurisma da Aorta Torácica/etiologia , Prótese Vascular , Implante de Prótese Vascular , Doenças das Artérias Carótidas/etiologia , Procedimentos Endovasculares , Feminino , Humanos
14.
J Cardiovasc Med (Hagerstown) ; 25(4): 311-317, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488065

RESUMO

AIMS: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice. METHODS: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years. RESULTS: Sixty-six patients (29% male individuals), mean age 43 ±â€Š16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period. CONCLUSION: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Ecocardiografia Transesofagiana , Fluoroscopia , Resultado do Tratamento
15.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

16.
Surg Technol Int ; 23: 199-204, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24081853

RESUMO

The stent graft is a noncompliant system inserted in a semi-compliant structure. This generates a mismatch. The media also shows a composite movement and is oriented 45° resulting in an arterial spiral movement that contributes to maintaining the clockwise orientation of laminar flow with an 80° deflection. Our multilayer stent is constituted by a single Nitinol thread, worked on 3 surfaces in order to realize a proper exoskeleton that reproduces the architecture of the tunica media, in particular its flexo-torsional forces, thus restoring the energy transmission and the match between the wall and the blood flow. A first in vivo implantation was performed by using an experimental pig model in our veterinary department. The pig underwent general anesthesia and the right femoral artery was surgically exposed in order to accommodate a 12F long introducer sheath. Under fluoroscopy three multilayer stents were consecutively implanted from the aortic isthmus to the iliac bifurcation in an overlap fashion. All the intercostal artery and visceral branches were covered by the overlapped stents. The final control angiography revealed an optimal sealing of the implanted stent with an evident flexotorsional oscillatory movement, which follows the conical architecture of the thoracic aorta and the complete patency of all the branches that arise from the aorta. After two months, the multilayer showed a normal endothelialization process with an optimal adhesion to the aortic wall both proximally and distally without provoking any inflammatory response or thickness wall alterations. The perfect and homogenous endothelialization preserved the patency of all the collateral branches arising from the treated aorta, in particular all the intercostal arteries, celiac trunk, and renal arteries. The disease of the aorta essentially concerns the tunica media as it causes disruption of the media components. This exoskeleton works like a neo-tunica media, is perfectly endothelialized, and seems to optimally transmit the flexotorsional forces, restoring the match between wall and flow that represents the primary condition for laminar flow and branch perfusion.


Assuntos
Aorta/patologia , Aorta/cirurgia , Prótese Vascular , Stents , Adesividade , Animais , Análise de Falha de Equipamento , Desenho de Prótese , Suínos , Resultado do Tratamento
17.
Hellenic J Cardiol ; 70: 19-27, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36581137

RESUMO

BACKGROUND: Acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is a frequent complication associated with adverse outcomes and mortality. Various scores have been developed to predict this complication in the coronary setting. However, none have ever been tested in a large TAVI population. This study aimed to evaluate the power of four different scores in predicting AKI after TAVI. METHODS: Overall, 1535 consecutive TAVI patients from the observational multicentric "Magna Graecia" TAVI registry were included in the analysis. Of the study population, 235 (15.31%) developed AKI early. The Mehran, William Beaumont Hospital, CR4EATME3AD3, and ACEF scores were calculated retrospectively. RESULTS: The patients who developed TAVI-related AKI had significantly higher absolute values of all risk scores than those who did not. The receiver-operating characteristic analysis also showed a significant correlation between these four scores and AKI, but without a significant difference among all of them (p value = 0.176). Nevertheless, based on their area under the curve values (≤0.604 for all), none had adequate diagnostic accuracy in predicting TAVI-related AKI. Importantly, multivariate analysis identified myocardial revascularization close to the TAVI procedure and implantation of self-expanding prostheses, as well as atrial fibrillation, low-osmolar contrast media administration, corrected contrast medium volume, and any transfusion (p value < 0.05 for all) as independent risk factors for AKI. CONCLUSIONS: Although high values of current AKI risk scores are significantly associated with the development of this complication, these are not sufficiently accurate. Further studies are needed so that a TAVI-dedicated AKI risk score may be created.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
18.
J Cardiovasc Dev Dis ; 10(6)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37367409

RESUMO

BACKGROUND: Surgical mortality risk scores, even if not properly designed and rarely tested in the transcatheter aortic valve implantation (TAVI) setting, still guide the heart team in managing significant aortic stenosis. METHODS: After splitting 1763 consecutive patients retrospectively based on their mortality risk thresholds, the composite endpoint early safety (ES) was adjudicated according to Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. RESULTS: ES incidence was higher if VARC-2 rather than VARC-3 defined. Despite only patients showing VARC-2 ES had significantly lower absolute values of all three main risk scores, these last still failed to foresee both VARC-2 and -3 ES in intermediate-risk patients. The receiver operating characteristic analysis also showed a significant correlation, but with poor diagnostic accuracy, among the three scores and only VARC-2 ES; moreover, the absence of VARC-2 ES and low-osmolar contrast media administration were identified as independent predictors of 1-year mortality and absence of VARC-3 ES, respectively. Finally, even a single complication included in the ES definition could significantly affect 1-year mortality. CONCLUSION: Currently, the most used mortality risk scores do not have adequate diagnostic accuracy in predicting ES after TAVI. The absence of VARC-2, instead of VARC-3, ES is an independent predictor of 1-year mortality.

19.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37998517

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an almost totally cine-fluoroscopic guided procedure. The amount of radiation used during the procedure is strictly related to the fluoroscopy time (FT), that has already been demonstrated to be associated with outcomes and complexity of coronary procedures. The aim of our study is to demonstrate the relationship between FT and the short-term outcomes after TAVR defined by to the Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. METHODS: After splitting 1797 consecutive patients into tertiles of FT, the composite endpoint early safety (ES) was adjudicated according to VARC-2 and VARC-3 definitions, whereas the composite endpoints device success (DS) and technical success (TS) according to VARC-3 criteria. RESULTS: The absence of all these outcomes (VARC-2 ES amd VARC-3 TS, DS, and ES) was significantly associated with longer FT: this association was independent from both intraprocedural complications and other intraprocedural factors linked to longer FT, and still persisted after propensity score matching analysis. Notwithstanding, after receiver operating characteristic analysis, FT had adequate diagnostic accuracy in identifying the absence of only VARC-3 TS and VARC-2 ES. CONCLUSION: Longer FT is related with periprocedural and short-term outcomes after the procedure, especially in those that are more challenging. A FT duration of more than 30 min has an adequate accuracy in identifying VARC-3 technical failure (TS and DS) and absence of VARC-2 ES, selecting patients who are likely to take advantage from more careful in-hospital follow-up.

20.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA