RESUMO
BACKGROUND: To assess the feasibility of biventricular SAPPHIRE T1 mapping in vivo across field strengths using diastolic, systolic and dark-blood (DB) approaches. METHODS: 10 healthy volunteers underwent same-day non-contrast cardiovascular magnetic resonance at 1.5 Tesla (T) and 3 T. Left and right ventricular (LV, RV) T1 mapping was performed in the basal, mid and apical short axis using 4-variants of SAPPHIRE: diastolic, systolic, 0th and 2nd order motion-sensitized DB and conventional modified Look-Locker inversion recovery (MOLLI). RESULTS: LV global myocardial T1 times (1.5 T then 3 T results) were significantly longer by diastolic SAPPHIRE (1283 ± 11|1600 ± 17 ms) than any of the other SAPPHIRE variants: systolic (1239 ± 9|1595 ± 13 ms), 0th order DB (1241 ± 10|1596 ± 12) and 2nd order DB (1251 ± 11|1560 ± 20 ms, all p < 0.05). In the mid septum MOLLI and diastolic SAPPHIRE exhibited significant T1 signal contamination (longer T1) at the blood-myocardial interface not seen with the other 3 SAPPHIRE variants (all p < 0.025). Additionally, systolic, 0th order and 2nd order DB SAPPHIRE showed narrower dispersion of myocardial T1 times across the mid septum when compared to diastolic SAPPHIRE (interquartile ranges respectively: 25 ms, 71 ms, 73 ms vs 143 ms, all p < 0.05). RV T1 mapping was achievable using systolic, 0th and 2nd order DB SAPPHIRE but not with MOLLI or diastolic SAPPHIRE. All 4 SAPPHIRE variants showed excellent re-read reproducibility (intraclass correlation coefficients 0.953 to 0.996). CONCLUSION: These small-scale preliminary healthy volunteer data suggest that DB SAPPHIRE has the potential to reduce partial volume effects at the blood-myocardial interface, and that systolic SAPPHIRE could be a feasible solution for right ventricular T1 mapping. Further work is needed to understand the robustness of these sequences and their potential clinical utility.
Assuntos
Óxido de Alumínio , Interpretação de Imagem Assistida por Computador , Frequência Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Valor Preditivo dos Testes , Reprodutibilidade dos TestesRESUMO
BACKGROUND: The T1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T1 measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B0 and B1, and "reference" slow T1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T1 variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B0 and B1 homogenous, and "reference" T1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T1 times with "reference" T1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R2 ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T1 across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T1 times for clinical use, although temperature correction is required for native T1 tubes at least.
Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas/normas , Consenso , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos TestesRESUMO
Chronic obstructive pulmonary disease (COPD) is a complex multi-morbid disorder with significant cardiac mortality. Current cardiovascular risk prediction models do not include COPD. We investigated whether COPD modifies future cardiovascular risk to determine if it should be considered in risk prediction models.Case-control study using baseline data from two randomized controlled trials performed between 2012 and 2015. Of the 90 eligible subjects, 26 COPD patients with lung hyperinflation were propensity matched for 10-year global cardiovascular risk score (QRISK2) with 26 controls having normal lung function. Patients underwent cardiac magnetic resonance imaging, arterial stiffness and lung function measurements. Differences in pulse wave velocity (PWV), total arterial compliance (TAC) and aortic distensibility were main outcome measures.PWV (mean difference 1.0 m/s, 95% CI 0.02-1.92; p = 0.033) and TAC (mean difference -0.27 mL/m2/mmHg, 95% CI 0.39-0.15; p < 0.001) were adversely affected in COPD compared to the control group. The PWV difference equates to an age, sex and risk-factor adjusted increase in relative risk of cardiovascular events and mortality of 14% and 15%, respectively.There were no differences in aortic distensibility. In the whole cohort (n = 90) QRISK2 (ß = 0.045, p = 0.005) was associated with PWV in multivariate analysis. The relationship between QRISK2 and PWV were modified by COPD, where the interaction term reached significance (p = 0.014). FEV1 (ß = 0.055 (0.027), p = 0.041) and pulse (B = -0.006 (0.002), p = 0.003) were associated with TAC in multivariate analysis.Markers of cardiovascular outcomes are adversely affected in COPD patients with lung hyperinflation compared to controls matched for global cardiovascular risk. Cardiovascular risk algorithms may benefit from the addition of a COPD variable to improve risk prediction and guide management.HAPPY London ClinicalTrials.gov: NCT01911910 and HZC116601; ClinicalTrials.gov: NCT01691885.
Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Fatores de Risco de Doenças Cardíacas , Ventrículos do Coração/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Análise de Onda de Pulso , Rigidez Vascular , Idoso , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , Estudos de Casos e Controles , Feminino , Volume Expiratório Forçado , Ventrículos do Coração/patologia , Humanos , Hipertensão/epidemiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Volume Residual , Capacidade Pulmonar Total , Capacidade VitalRESUMO
PURPOSE: To investigate: (1) the feasibility of using through-time radial GeneRalized Autocalibrating Partially Parallel Acquisitions (rGRAPPA) and hybrid radial GRAPPA (h-rGRAPPA) in single- and multislice dynamic speech MRI; (2) whether single-slice dynamic speech MRI at a rate of 15 frames per second (fps) or higher and with adequate image quality can be achieved using these radial GRAPPA techniques. METHODS: Seven healthy adult volunteers were imaged at 3T using a 16-channel neurovascular coil and 2 spoiled gradient echo sequences (radial trajectory, field of view = 192 × 192 mm2 , acquired pixel size = 2.4 × 2.4 mm2 ). One sequence imaged a single slice at 16.8 fps, the other imaged 2 interleaved slices at 7.8 fps per slice. Image sets were reconstructed using rGRAPPA and h-rGRAPPA, and their image quality was compared using the root mean square error, structural similarity index, and visual assessments. RESULTS: Image quality deteriorated when fewer than 170 calibration frames were used in the rGRAPPA reconstruction. rGRAPPA image sets demonstrated: (1) in 97% of cases, a similar image quality to h-rGRAPPA image sets reconstructed using a k-space segment size of 4, (2) in 98% of cases, a better image quality than h-rGRAPPA image sets reconstructed using a k-space segment size of 32. CONCLUSION: This study confirmed: (1) the feasibility of using rGRAPPA and h-rGRAPPA in single- and multislice dynamic speech MRI, (2) that single-slice speech imaging at a frame rate higher than 15 fps and with adequate image quality can be achieved using these radial GRAPPA techniques.
Assuntos
Cabeça/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Fala/fisiologia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Adulto JovemRESUMO
RATIONALE: Patients with chronic obstructive pulmonary disease develop increased cardiovascular morbidity with structural alterations. OBJECTIVES: To investigate through a double-blind, placebo-controlled, crossover study the effect of lung deflation on cardiovascular structure and function using cardiac magnetic resonance. METHODS: Forty-five hyperinflated patients with chronic obstructive pulmonary disease were randomized (1:1) to 7 (maximum 14) days inhaled corticosteroid/long-acting ß2-agonist fluticasone furoate/vilanterol 100/25 µg or placebo (7-day minimum washout). Primary outcome was change from baseline in right ventricular end-diastolic volume index versus placebo. MEASUREMENTS AND MAIN RESULTS: There was a 5.8 ml/m(2) (95% confidence interval, 2.74-8.91; P < 0.001) increase in change from baseline right ventricular end-diastolic volume index and a 429 ml (P < 0.001) reduction in residual volume with fluticasone furoate/vilanterol versus placebo. Left ventricular end-diastolic and left atrial end-systolic volumes increased by 3.63 ml/m(2) (P = 0.002) and 2.33 ml/m(2) (P = 0.002). In post hoc analysis, right ventricular stroke volume increased by 4.87 ml/m(2) (P = 0.003); right ventricular ejection fraction was unchanged. Left ventricular adaptation was similar; left atrial ejection fraction improved by +3.17% (P < 0.001). Intrinsic myocardial function was unchanged. Pulmonary artery pulsatility increased in two of three locations (main +2.9%, P = 0.001; left +2.67%, P = 0.030). Fluticasone furoate/vilanterol safety profile was similar to placebo. CONCLUSIONS: Pharmacologic treatment of chronic obstructive pulmonary disease has consistent beneficial and plausible effects on cardiac function and pulmonary vasculature that may contribute to favorable effects of inhaled therapies. Future studies should investigate the effect of prolonged lung deflation on intrinsic myocardial function. Clinical trial registered with www.clinicaltrials.gov (NCT 01691885).
Assuntos
Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Androstadienos/administração & dosagem , Álcoois Benzílicos/administração & dosagem , Clorobenzenos/administração & dosagem , Coração/efeitos dos fármacos , Pulmão/fisiopatologia , Miocárdio/patologia , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Administração por Inalação , Corticosteroides/administração & dosagem , Idoso , Broncodilatadores/administração & dosagem , Estudos Cross-Over , Combinação de Medicamentos , Feminino , Volume Expiratório Forçado/efeitos dos fármacos , Coração/fisiopatologia , Humanos , Pulmão/efeitos dos fármacos , Pulmão/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/fisiopatologiaRESUMO
BACKGROUND: UK Biobank's ambitious aim is to perform cardiovascular magnetic resonance (CMR) in 100,000 people previously recruited into this prospective cohort study of half a million 40-69 year-olds. METHODS/DESIGN: We describe the CMR protocol applied in UK Biobank's pilot phase, which will be extended into the main phase with three centres using the same equipment and protocols. The CMR protocol includes white blood CMR (sagittal anatomy, coronary and transverse anatomy), cine CMR (long axis cines, short axis cines of the ventricles, coronal LVOT cine), strain CMR (tagging), flow CMR (aortic valve flow) and parametric CMR (native T1 map). DISCUSSION: This report will serve as a reference to researchers intending to use the UK Biobank resource or to replicate the UK Biobank cardiovascular magnetic resonance protocol in different settings.
Assuntos
Bancos de Espécimes Biológicos , Protocolos Clínicos , Cardiopatias/diagnóstico , Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Cardiopatias/patologia , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reino UnidoRESUMO
BACKGROUND: T1 mapping and extracellular volume (ECV) have the potential to guide patient care and serve as surrogate end-points in clinical trials, but measurements differ between cardiovascular magnetic resonance (CMR) scanners and pulse sequences. To help deliver T1 mapping to global clinical care, we developed a phantom-based quality assurance (QA) system for verification of measurement stability over time at individual sites, with further aims of generalization of results across sites, vendor systems, software versions and imaging sequences. We thus created T1MES: The T1 Mapping and ECV Standardization Program. METHODS: A design collaboration consisting of a specialist MRI small-medium enterprise, clinicians, physicists and national metrology institutes was formed. A phantom was designed covering clinically relevant ranges of T1 and T2 in blood and myocardium, pre and post-contrast, for 1.5 T and 3 T. Reproducible mass manufacture was established. The device received regulatory clearance by the Food and Drug Administration (FDA) and Conformité Européene (CE) marking. RESULTS: The T1MES phantom is an agarose gel-based phantom using nickel chloride as the paramagnetic relaxation modifier. It was reproducibly specified and mass-produced with a rigorously repeatable process. Each phantom contains nine differently-doped agarose gel tubes embedded in a gel/beads matrix. Phantoms were free of air bubbles and susceptibility artifacts at both field strengths and T1 maps were free from off-resonance artifacts. The incorporation of high-density polyethylene beads in the main gel fill was effective at flattening the B 1 field. T1 and T2 values measured in T1MES showed coefficients of variation of 1 % or less between repeat scans indicating good short-term reproducibility. Temperature dependency experiments confirmed that over the range 15-30 °C the short-T1 tubes were more stable with temperature than the long-T1 tubes. A batch of 69 phantoms was mass-produced with random sampling of ten of these showing coefficients of variations for T1 of 0.64 ± 0.45 % and 0.49 ± 0.34 % at 1.5 T and 3 T respectively. CONCLUSION: The T1MES program has developed a T1 mapping phantom to CE/FDA manufacturing standards. An initial 69 phantoms with a multi-vendor user manual are now being scanned fortnightly in centers worldwide. Future results will explore T1 mapping sequences, platform performance, stability and the potential for standardization.
RESUMO
Background: Heterogenous deposition and homeostasis roles of physiologic and ectopic adipose tissues underscore the impact of fat compartmentalization on cardiometabolic risk. We aimed to characterize the distribution of abdominal visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT), epicardial adipose tissue (EAT), and liver fat on magnetic resonance imaging (MRI), and evaluate their associations with anthropometric indices and adverse cardiac remodeling. Methods: In this cross-sectional observational study, 149 Asian adults (57.0 ± 12.8 years; 65% males) with at least one cardiometabolic risk factor underwent multiparametric fat and cardiovascular MRI. Anthropometric indices included body mass index (BMI), waist circumference (WC), waist-hip ratio (WHR), and bioimpedance body fat mass (BFM). Associations between fat depots and anthropometric measures as well as cardiac remodeling features were examined as a single cohort and stratified by type 2 diabetes mellitus (T2DM) status. Results: VAT and SAT had opposing associations with liver fat and EAT. Therefore the VAT/SAT ratio was explored as an integrated marker of visceral adiposity. VAT/SAT was positively associated with EAT (ß=0.35, P<0.001) and liver fat (ß=0.32, P=0.003) independent of confounders. Of the anthropometric measurements assessed, only WHR was independently associated with VAT/SAT (ß=0.17, P=0.021). Individuals with T2DM had higher VAT and lower SAT compared to those without T2DM, translating to a significantly higher VAT/SAT ratio. EAT volume was independently associated with adverse features of cardiac remodeling: increased left ventricular (LV) mass (ß=0.24, P=0.005), larger myocyte volume (ß=0.26, P=0.001), increased myocardial fibrosis (ß=0.19, P=0.023), higher concentricity (ß=0.18, P=0.035), and elevated wall stress (ß=-0.18, P=0.023). Conclusion: Multiparametric MRI revealed abdominal VAT and SAT have differential associations with anthropometric indices and ectopic fats in a single cohort of Asians at risk of cardiometabolic disease. People with T2DM have expanded VAT and diminished SAT, endorsing the VAT/SAT ratio beyond usual anthropometric measurements as a marker for multiorgan visceral fat composition. Among the fat depots examined, EAT is uniquely associated with adverse cardiac remodeling, suggesting its distinctive cardiometabolic properties and implications.
Assuntos
Adiposidade , Gordura Intra-Abdominal , Pericárdio , Remodelação Ventricular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Adiposidade/fisiologia , Pericárdio/diagnóstico por imagem , Pericárdio/patologia , Gordura Intra-Abdominal/diagnóstico por imagem , Gordura Intra-Abdominal/patologia , Idoso , Diabetes Mellitus Tipo 2/patologia , Diabetes Mellitus Tipo 2/fisiopatologia , Povo Asiático , Fígado/diagnóstico por imagem , Fígado/patologia , Antropometria , Imageamento por Ressonância Magnética , Adulto , Gordura Abdominal/diagnóstico por imagem , Gordura Abdominal/patologiaRESUMO
Achieving sufficient temporal and spatial resolution with adequate signal-to-noise ratio (SNR) in dynamic soft palate imaging is challenging. Triggered acquisitions require repeated reproducible speech samples, and while real-time imaging is more reliable, it may lack SNR. Adaptive averaging was implemented to improve SNR in nongated imaging during repetition of a speech task. Similar images were identified using localized cross-correlation before averaging. Adaptive averaging was applied to the soft palate region of images from six volunteers and one patient acquired with various sequences. In volunteers, soft palate SNR increased by 53 ± 17% with four averages. The additional SNR was used to enable reduced slice thickness in two example subjects. Adaptive averaging was also compared to pseudotriggered images in one example and, in another, it was applied to an unrepeated speech task. In a patient with a repaired cleft palate, the technique was used to demonstrate residual velopharyngeal insufficiency. This initial work demonstrates that increased temporal or spatial resolution may be traded for reduced SNR, which can be recovered using adaptive averaging. This will be a valuable tool in assessing velopharyngeal function, particularly in pediatric patients where cooperation may make gated studies difficult or when their head sizes require increased spatial resolution while maintaining temporal resolution.
Assuntos
Imageamento por Ressonância Magnética/métodos , Palato Mole/anatomia & histologia , Adolescente , Adulto , Algoritmos , Fissura Palatina/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído , FalaRESUMO
INTRODUCTION: We tested the hypothesis that cardiovascular magnetic resonance (CMR) imaging can reliably distinguish the presence or absence of left atrial (LA) ablation lesions by blinded analysis of pre- and postablation imaging. METHODS: Consecutive patients at 2 centers undergoing pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation by either wide area circumferential radiofrequency ablation (WACA) or ostial ablation with a cryoballoon underwent CMR late gadolinium enhancement (LGE) imaging pre- and 3 months postablation. Imaging was anonymized for blinded analysis of (1) LGE images, and (2) a 3D fusion image with LGE projected onto a segmented LA surface. Scans were categorized using both assessment techniques separately as pre- or postablation, and if postablation, whether lesions were in an ostial or WACA distribution. RESULTS: LGE imaging was performed in 50 patients (aged 60 ± 10 years, 68% male, 24 underwent WACA and 26 had cryoablation). Sensitivity and specificity for detection of ablation lesions was 60% and 96% on LGE imaging. Sensitivity was higher using 3D fusion imaging (88%; P = 0.003). The proportion in whom lesions were both detected and the distribution correctly assessed as WACA or ostial was higher with 3D fusion imaging compared to LGE imaging (54% vs 28%; P = 0.014). There was no difference in the detection of radiofrequency ablation lesions compared to cryoablation lesions (58% vs 62%; P = 1.000). CONCLUSION: LGE imaging of atrial scar is not yet sufficiently accurate to reliably identify ablation lesions or to determine lesion distribution.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Cicatriz/patologia , Criocirurgia , Imageamento por Ressonância Magnética , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/patologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Cicatriz/etiologia , Meios de Contraste , Criocirurgia/efeitos adversos , Feminino , Gadolínio DTPA , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Logísticos , Londres , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Razão de Chances , Valor Preditivo dos Testes , Veias Pulmonares/patologia , Reprodutibilidade dos Testes , Resultado do TratamentoRESUMO
OBJECTIVES: To develop a single-slice numerical phantom with known myocardial motion, at several temporal and in-plane spatial resolutions, for testing and comparison of Cardiovascular Magnetic Resonance (CMR) feature tracking (FT) software. METHODS: The phantom was developed based on CMR acquisitions of one volunteer (acquired cine, tagging cine, T1 map, T2 map, proton density weighted image). The numerical MRI simulator JEMRIS was used, and the phantom was generated at several in-plane spatial resolutions (1.4 × 1.4 mm2 to 3.0 × 3.0 mm2) and temporal resolutions (20 to 40 cardiac phases). Two feature tracking software packages were tested: Medical Image Tracking Toolbox (MITT) and two versions of cvi42 (v5.3.8 and v5.13.7). The effect of resolution on strain results was investigated with reference to ground-truth radial and circumferential strain. RESULTS: Peak radial strain was consistently undermeasured more for cvi42 v5.13.7 than for v5.3.8. Increased pixel size produced a trend of increased difference from ground-truth peak strain, with the largest changes for cvi42 obtained using v5.13.7 between 1.4 × 1.4 mm2 and 3.0 × 3.0 mm2, at 9.17 percentage points (radial) and 8.42 percentage points (circumferential). CONCLUSIONS: The results corroborate the presence of intervendor differences in feature tracking results and show the magnitude of strain differences between software versions. ADVANCES IN KNOWLEDGE: This study shows how temporal and in-plane spatial resolution can affect feature tracking with reference to the ground-truth strain of a numerical phantom. Results reaffirm the need for numerical phantom development for the validation and testing of FT software.
Assuntos
Contração Miocárdica , Função Ventricular Esquerda , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Valor Preditivo dos Testes , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos TestesRESUMO
AIMS: To explore the impact of incorporating a faster cardiac magnetic resonance (CMR) imaging protocol in a low-middle-income country (LMIC) and using the result to guide chelation in transfusion-dependent patients. METHODS AND RESULTS: A prospective UK-India collaborative cohort study was conducted in two cities in India. Two visits 13 months apart included clinical assessment and chelation therapy recommendations based on rapid CMR results. Participants were recruited by the local patient advocate charity, who organized the patient medical camps. The average scanning time was 11.3 ± 2.5 min at the baseline and 9.8 ± 2.4 min (P < 0.001) at follow-up. The baseline visit was attended by 103 patients (mean age 25 years) and 83% attended the second assessment. At baseline, 29% had a cardiac T2* < 20 ms, which represents significant iron loading, and 12% had left ventricular ejection fraction <60%, the accepted lower limit in this population. Only 3% were free of liver iron (T2* ≥ 17 ms). At 13 months, more patients were taking intensified dual chelation therapy (43% vs. 55%, P = 0.002). In those with cardiac siderosis (baseline T2* < 20 ms), there was an improvement in T2*-10.9 ± 5.9 to 13.5 ± 8.7 ms, P = 0.005-and fewer were classified as having clinically important cardiac iron loading (T2* < 20 ms, 24% vs. 16%, P < 0.001). This is the first illustration in an LMIC that incorporating CMR results into patient management plans can improve cardiac iron loading. CONCLUSION: For thalassaemia patients in an LMIC, a simplified CMR protocol linked to therapeutic recommendation via the patient camp model led to enhanced chelation therapy and a reduction in cardiac iron in 1 year.
Assuntos
Talassemia , Talassemia beta , Adulto , Terapia por Quelação/métodos , Estudos de Coortes , Humanos , Ferro , Imageamento por Ressonância Magnética , Estudos Prospectivos , Volume Sistólico , Talassemia/terapia , Função Ventricular Esquerda , Talassemia beta/patologia , Talassemia beta/terapiaRESUMO
BACKGROUND: Quantitative cardiovascular magnetic resonance T1-mapping is increasingly used for myocardial tissue characterization. However, the lack of standardization limits direct comparability between centers and wider roll-out for clinical use or trials. PURPOSE: To develop a quality assurance (QA) program assuring standardized T1 measurements for clinical use. METHODS: MR phantoms manufactured in 2013 were distributed, including ShMOLLI T1-mapping and reference T1 and T2 protocols. We first studied the T1 and T2 dependency on temperature and phantom aging using phantom datasets from a single site over 4 years. Based on this, we developed a multiparametric QA model, which was then applied to 78 scans from 28 other multi-national sites. RESULTS: T1 temperature sensitivity followed a second-order polynomial to baseline T1 values (R2 > 0.996). Some phantoms showed aging effects, where T1 drifted up to 49% over 40 months. The correlation model based on reference T1 and T2, developed on 1004 dedicated phantom scans, predicted ShMOLLI-T1 with high consistency (coefficient of variation 1.54%), and was robust to temperature variations and phantom aging. Using the 95% confidence interval of the correlation model residuals as the tolerance range, we analyzed 390 ShMOLLI T1-maps and confirmed accurate sequence deployment in 90%(70/78) of QA scans across 28 multiple centers, and categorized the rest with specific remedial actions. CONCLUSIONS: The proposed phantom QA for T1-mapping can assure correct method implementation and protocol adherence, and is robust to temperature variation and phantom aging. This QA program circumvents the need of frequent phantom replacements, and can be readily deployed in multicenter trials.
Assuntos
Cardiomiopatia Hipertrófica , Imageamento por Ressonância Magnética , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Sistema de Registros , Reprodutibilidade dos TestesRESUMO
Dynamic and real-time MRI (rtMRI) of human speech is an active field of research, with interest from both the linguistics and clinical communities. At present, different research groups are investigating a range of rtMRI acquisition and reconstruction approaches to visualise the speech organs. Similar to other moving organs, it is difficult to create a physical phantom of the speech organs to optimise these approaches; therefore, the optimisation requires extensive scanner access and imaging of volunteers. As previously demonstrated in cardiac imaging, realistic numerical phantoms can be useful tools for optimising rtMRI approaches and reduce reliance on scanner access and imaging volunteers. However, currently, no such speech rtMRI phantom exists. In this work, a numerical phantom for optimising speech rtMRI approaches was developed and tested on different reconstruction schemes. The novel phantom comprised a dynamic image series and corresponding k-space data of a single mid-sagittal slice with a temporal resolution of 30 frames per second (fps). The phantom was developed based on images of a volunteer acquired at a frame rate of 10 fps. The creation of the numerical phantom involved the following steps: image acquisition, image enhancement, segmentation, mask optimisation, through-time and spatial interpolation and finally the derived k-space phantom. The phantom was used to: (1) test different k-space sampling schemes (Cartesian, radial and spiral); (2) create lower frame rate acquisitions by simulating segmented k-space acquisitions; (3) simulate parallel imaging reconstructions (SENSE and GRAPPA). This demonstrated how such a numerical phantom could be used to optimise images and test multiple sampling strategies without extensive scanner access.
RESUMO
PURPOSE: To test the diagnostic performance of cardiovascular magnetic resonance (CMR) tissue-tracking (TT) to detect the presence of late gadolinium enhancement (LGE) in patients with a diagnosis of myocardial infarction (MI) or myocarditis (MYO), preserved left ventricular ejection fraction (LVEF) and no visual regional wall motion abnormalities (RWMA). METHODS: We selected consecutive CMR studies of 50 MI, 50 MYO and 96 controls. Receiving operating characteristic (ROC) curve and net reclassification index (NRI) analyses were used to assess the predictive ability and the incremental diagnostic yield of 2D and 3D TT-derived strain parameters for the detection of LGE and to measure the best cut-off values of strain parameters. RESULTS: Overall, cases showed significantly reduced 2D global longitudinal strain (2D-GLS) values compared with controls (-20.1 ± 3.1% vs -21.6 ± 2.7%; p = 0.0008). 2D-GLS was also significantly reduced in MYO patients compared with healthy controls (-19.7 ± 2.9% vs -21.9 ± 2.4%; p = 0.0001). 3D global radial strain (3D-GRS) was significantly reduced in MI patients compared with controls with risk factors (34.3 ± 11.8% vs 40.3 ± 12.5%, p = 0.024) Overall, 2D-GLS yielded good diagnostic accuracy for the detection of LGE in the MYO subgroup (AUROC 0.79; NRI (95% CI) = 0.6 (0.3, 1.02) p = 0.0004), with incremental predictive value beyond risk factors and LV function parameters (p for AUROC difference = 0.048). In the MI subgroup, 2D-GRS (AUROC 0.81; NRI (95% CI) = 0.56 (0.17, 0.95) p = 0.004), 3D-GRS (AUROC 0.82; NRI (95% CI) = 0.57 (0.17, 0.97) p = 0.006) and 3D global circumferential strain (3D-GCS) (AUROC 0.81; NRI (95% CI) = 0.62 (0.22, 1.01) p = 0.002) emerged as potential markers of disease. The best cut-off for 2D-GLS was -21.1%, for 2D- and 3D-GRS were 39.1% and 37.7%, respectively, and for 3D-GCS was -16.4%. CONCLUSIONS: At CMR-tissue tracking analysis, 2D-GLS was a significant predictor of LGE in patients with myocarditis but preserved LVEF and no visual RWMA. Both 2D- and 3D-GRS and 2D-GCS yielded good diagnostic accuracy for LGE detection in patients with previous MI but preserved LVEF and no visual RWMA.
Assuntos
Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocardite/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocardite/patologia , Miocardite/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Volume SistólicoRESUMO
AIMS: Left ventricular hypertrophy (LVH) in aortic stenosis (AS) varies widely before and after aortic valve replacement (AVR), and deeper phenotyping beyond traditional global measures may improve risk stratification. We hypothesized that machine learning derived 3D LV models may provide a more sensitive assessment of remodelling and sex-related differences in AS than conventional measurements. METHODS AND RESULTS: One hundred and sixteen patients with severe, symptomatic AS (54% male, 70 ± 10 years) underwent cardiovascular magnetic resonance pre-AVR and 1 year post-AVR. Computational analysis produced co-registered 3D models of wall thickness, which were compared with 40 propensity-matched healthy controls. Preoperative regional wall thickness and post-operative percentage wall thickness regression were analysed, stratified by sex. AS hypertrophy and regression post-AVR was non-uniform-greatest in the septum with more pronounced changes in males than females (wall thickness regression: -13 ± 3.6 vs. -6 ± 1.9%, respectively, P < 0.05). Even patients without LVH (16% with normal indexed LV mass, 79% female) had greater septal and inferior wall thickness compared with controls (8.8 ± 1.6 vs. 6.6 ± 1.2 mm, P < 0.05), which regressed post-AVR. These differences were not detectable by global measures of remodelling. Changes to clinical parameters post-AVR were also greater in males: N-terminal pro-brain natriuretic peptide (NT-proBNP) [-37 (interquartile range -88 to -2) vs. -1 (-24 to 11) ng/L, P = 0.008], and systolic blood pressure (12.9 ± 23 vs. 2.1 ± 17 mmHg, P = 0.009), with changes in NT-proBNP correlating with percentage LV mass regression in males only (ß 0.32, P = 0.02). CONCLUSION: In patients with severe AS, including those without overt LVH, LV remodelling is most plastic in the septum, and greater in males, both pre-AVR and post-AVR. Three-dimensional machine learning is more sensitive than conventional analysis to these changes, potentially enhancing risk stratification. CLINICAL TRIAL REGISTRATION: Regression of myocardial fibrosis after aortic valve replacement (RELIEF-AS); NCT02174471. https://clinicaltrials.gov/ct2/show/NCT02174471.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Aprendizado de Máquina , Masculino , Função Ventricular EsquerdaRESUMO
OBJECTIVE: In patients with hypertrophic cardiomyopathy (HCM), the role of small vessel disease and myocardial perfusion remains incompletely understood and data on absolute myocardial blood flow (MBF, mL/g/min) are scarce. We measured MBF using cardiovascular magnetic resonance fully quantitative perfusion mapping to determine the relationship between perfusion, hypertrophy and late gadolinium enhancement (LGE) in HCM. METHODS: 101 patients with HCM with unobstructed epicardial coronary arteries and 30 controls (with matched cardiovascular risk factors) underwent pixel-wise perfusion mapping during adenosine stress and rest. Stress, rest MBF and the myocardial perfusion reserve (MPR, ratio of stress to rest) were calculated globally and segmentally and then associated with segmental wall thickness and LGE. RESULTS: In HCM, 79% had a perfusion defect on clinical read. Stress MBF and MPR were reduced compared with controls (mean±SD 1.63±0.60 vs 2.30±0.64 mL/g/min, p<0.0001 and 2.21±0.87 vs 2.90±0.90, p=0.0003, respectively). Globally, stress MBF fell with increasing indexed left ventricle mass (R2 for the model 0.186, p=0.036) and segmentally with increasing wall thickness and LGE (both p<0.0001). In 21% of patients with HCM, MBF was lower during stress than rest (MPR <1) in at least one myocardial segment, a phenomenon which was predominantly subendocardial. Apparently normal HCM segments (normal wall thickness, no LGE) had reduced stress MBF and MPR compared with controls (mean±SD 1.88±0.81 mL/g/min vs 2.32±0.78 mL/g/min, p<0.0001). CONCLUSIONS: Microvascular dysfunction is common in HCM and associated with hypertrophy and LGE. Perfusion can fall during vasodilator stress and is abnormal even in apparently normal myocardium suggesting it may be an early disease marker.
Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Circulação Coronária/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Microcirculação/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Cardiomiopatia Hipertrófica/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Seguimentos , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
OBJECTIVES: To assess whether electronic (e-) coaching, using personalized web-based lifestyle and risk factor counselling with additional email prompts, provides additional risk reduction when added to standard of care (SOC) in individuals at increased risk. METHODS: Between June 2013 and May 2015, 402 participants were allocated 1:1 to e-coaching and SOC versus SOC. Participants free of manifest cardiovascular disease, with internet access, and a 10-year QRISK2 cardiovascular risk of ≥10% were enrolled. Change in oscillometric carotid-femoral pulse wave velocity (PWV) from baseline to six months was the primary endpoint. Secondary outcomes included change in blood pressure (BP), weight, and risk scores. Analysis was by intention to treat. RESULTS: Mean (±SD) age was 65.5 (5.6) years with 37% females. Primary outcome data were available for 94%. There was no difference in PWV reductions between e-coaching and standard of care groups (-0.16 m/s vs. -0.25 m/s, 95% confidence interval -0.39 to 0.22, p = 0.56). There were no differences in the improvement between groups for BP, weight, Framingham, or QRISK2 scores. Pulse wave velocity change was more favorable in those with a higher level of education (p = 0.04), but was not associated with age, gender, presence of diabetes, baseline QRISK2 score, or logins to the website. CONCLUSIONS: In individuals at increased cardiovascular risk, a comprehensive 'health check' program modestly reduced future risk. Personalized e-coaching did not provide added risk reduction. Currently there is no evidence to routinely recommend e-coaching in cardiovascular health check programs. TRIAL REGISTRATION: HAPPY London ClinicalTrials.gov: NCT01911910.
Assuntos
Doenças Cardiovasculares/prevenção & controle , Aconselhamento Diretivo , Comportamento de Redução do Risco , Adulto , Idoso , Pressão Sanguínea , Peso Corporal , Escolaridade , Correio Eletrônico , Feminino , Humanos , Internet , Estilo de Vida , Masculino , Pessoa de Meia-Idade , Análise de Onda de Pulso , Fatores de Risco , Padrão de CuidadoRESUMO
Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) sequences have evolved. Free-breathing motion-corrected (MOCO) LGE has potential advantages over breath-held (bh) LGE including minimal user input for the short axis (SAX) stack without breath-holds. It has previously been shown that MOCO-LGE delivers high image quality compared to bh-LGE. We sought to conduct an independent validation study to investigate real-world performance of bh-LGE versus MOCO-LGE in a high-throughput CMR center immediately after the introduction of the MOCO-LGE sequence and with elementary staff induction in its use. Four-hundred consecutive patients, referred for CMR and graded by clinical complexity, underwent CMR on either of two scanners (1.5 T, both Siemens) in a UK tertiary cardiac center. Scar imaging was by bh-LGE or MOCO-LGE (both with phase sensitive inversion recovery). Image quality, scan time, reader confidence and report reproducibility were compared between those scanned by bh-LGE versus MOCO-LGE. Readers had > 3 years CMR experience. Categorical variables were compared by χ2 or Fisher's exact tests and continuous variables by unpaired Student's t-test. Inter-rater agreement of LGE reports was by Cohen's kappa. Image quality (low score = better) was better for MOCO-LGE (median, interquartile range [Q1-Q3]: 0 [0-0] vs. 2 [0-3], P < 0.0001). This persisted when just clinically complex patients were assessed (0 [0-1] vs. 2 [1-4] P < 0.0001). Readers were more confident in their MOCO-LGE rulings (P < 0.001) and reports more reproducible [bh-LGE vs. MOCO-LGE: kappa 0.76, confidence interval (CI) 0.7-0.9 vs. 0.82, CI 0.7-0.9]. MOCO-LGE significantly shortened LGE acquisition times compared to bh-LGE (for left ventricle SAX stack: 03:22 ± 01:14 vs 06:09 ± 01:47 min respectively, P < 0.0001). In a busy clinical service, immediately after its introduction and with elementary staff training, MOCO-LGE is demonstrably faster to bh-LGE, providing better images that are easier to interpret, even in the sickest of patients.
Assuntos
Meios de Contraste/administração & dosagem , Cardiopatias/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Meglumina/administração & dosagem , Miocárdio/patologia , Compostos Organometálicos/administração & dosagem , Função Ventricular Esquerda , Adulto , Idoso , Eficiência Organizacional , Feminino , Fibrose , Cardiopatias/patologia , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Centros de Atenção Terciária , Fatores de Tempo , Fluxo de TrabalhoRESUMO
BACKGROUND: Myocardial scar assessment using late gadolinium enhancement Cardiovascular Magnetic Resonance (LGE CMR) is commonly indicated for patients with cardiac implantable electronic devices (CIEDs), however metal artifact can degrade images. We evaluated the clinical impact of LGE CMR incorporating a device-dependent metal artifact reduction strategy in patients with CIEDs. METHODS: 136 CMR studies were performed in 133 consecutive patients (age 56⯱â¯19â¯years, 69% male) with CIEDs (22% implantable loop recorders [ILRs], 40% permanent pacemakers [PPMs], 38% implantable cardioverter defibrillators [ICDs]; 42% non-MRI conditional) over 2â¯years, without complication. LGE imaging was tailored to the CIED, using a wideband sequence for left-sided PPMs and ICDs and conventional sequences for ILRs and right-sided PPMs, scoring segmental artifact. Diagnostic utility and impact on clinical management were scored by consensus of experts. RESULTS: CMR provided unexpected diagnoses in 22 (16%) and changed management in 113 (83%) patients. Myocardial scar was present in 92 (68%), with other abnormalities detected in another 13%. Using conventional LGE, 43 (32%) studies were non-diagnostic (79% of defibrillators) compared to 0% using wideband LGE imaging. Wideband LGE results changed clinical management in an additional 39 (75%) defibrillator patients and 10 (19%) pacemaker patients when compared to imaging with conventional LGE sequences. CONCLUSION: The clinical yield from CMR using optimized LGE sequences in patients with CIEDs is high with no demonstrated clinical risk. A device-dependent LGE imaging strategy using wideband LGE is needed to achieve clinical utility especially in ICD recipients.