Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Neuroradiol ; 51(2): 182-189, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38065429

RESUMO

BACKGROUND: Energy consumption awareness is a known concern, and radiology departments have energy-intensive consuming machines. The means of energy consumption management in MRI scanners have yet to be evaluated. PURPOSE: To measure the MRI energy consumption and to evaluate the means to reduce it. MATERIALS AND METHODS: Data was retrieved for two MRI scanners through the hospital's automated energy consumption measurement software. After correlation with picture archiving and communication system (PACS) files, they were segmented by machine and mode (as follows: stand-by, idle and active) and analyzed. Active mode data for a specific brain MRI protocol have been isolated, and equivalent low energy consuming protocol was made. Both were performed on phantom and compared. Same protocol was performed on a phantom using 3.0T 16 and 32 head channels coils. Multiples sequences were acquired on phantom to evaluate power consumption. RESULTS: Stand-by mode accounted for 60 % of machine time and 40 % of energy consumption, active mode accounted for 20 % machine time and 40 % energy consumption, idle mode for 20 % imachine time and 20 % consumption. DWI and TOF sequences were the most consuming in our brain-MRI protocol. The low energy consuming protocol allowed a saving of approximately 10 % of energy consumption, which amounted for 0.20€ for each examination. This difference was mainly due to an energy consumption reduction of the DWI sequence. There were no difference in consumption between a 3.0T 16 and 32 channels head coils. Sequence's active power and duration (especially considering slice thickness) have to be taken into account when trying to optimize energy consumption. CONCLUSION: There are two key factors to consider when trying to reduce MRI scan energy consumption. Stand-by mode energy consumption has to be taken into account when choosing an MRI scan, as it can't be changed further on. Active mode energy consumption is dependent of the MRI protocols used, and can be reduced with sequences adaptation, which must take into account sequence's active power and duration, on top of image quality.


Assuntos
Imageamento por Ressonância Magnética , Neuroimagem , Humanos , Imagens de Fantasmas
2.
Q J Nucl Med Mol Imaging ; 65(1): 79-87, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30916534

RESUMO

BACKGROUND: PET Textural indices could have an add-on diagnostic value for diagnosis of malignancy in patients with FDG-avid adrenal lesions. METHODS: Consecutive patients referred for a FDG-PET/CT to our nuclear medicine department from June 2012 to June 2017 were retrospectively screened. Inclusion criteria were: patients with a FDG-avid adrenal lesion (uptake≥liver background); malignant/benign lesion confirmed histologically or with follow-up imaging examination. Pheochromocytomas were not included in the analysis. For each adrenal lesion, 5 quantitative PET parameters (SUVmax, MTV, TLG, TLRmax and TLRmean) were calculated. Thirty-seven textural indices were extracted using LIFEx software®. Diagnostic performance to determine malignancy was assessed with a ROC analysis. Parameters with a significantly AUC>0.5 were selected and groups of highly correlated (r>0.8) parameters were created. A scoring system combining PET and textural indices was examined. RESULTS: PET textural indices were calculated for 53 lesions (37 malignant, 16 benign). Three PET metabolic parameters (SUVmax, TLRmax, TLRmean) and 13 textural indices had an AUC>0.5. Seven groups of highly correlated parameters (r>0.8) were extracted. For PET parameters, SUVmax had the best AUC (0.89 95% CI [0.79-0.98]; cut-off=7.0). For textural indices, ZLNU had the best AUC (0.87 95% CI [0.78-0.96]; cut-off=34.7) and specificity of 100%. Three scores combining the best four textural indices alone (ContrastGLCM, LRHGE, SZE and ZLNU) or with one PET parameters (SUVmax, TLRmax) were developed but did not increase the diagnostic performance (AUC≤0.89). ZLNU was the best parameter to distinguish primary adrenal cancer from adrenal metastases in malignant lesions (P<0.001). CONCLUSIONS: Our study highlighted excellent diagnostic performance of several PET textural indices comparable to that of PET metabolic parameters. However, our results did not find any additional diagnostic value of textural indices when combined with metabolic parameters.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Fluordesoxiglucose F18/química , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/química , Glândulas Suprarrenais , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Software , Carga Tumoral
3.
Eur Radiol ; 30(9): 4857-4864, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32279113

RESUMO

OBJECTIVE: To assess the diagnostic accuracy of iodine map computed tomography pulmonary angiography (CTPA), for segment-based evaluation of lung perfusion in patients with acute pulmonary embolism (PE), using perfusion single-photon emission CT (SPECT) imaging as a reference standard. METHODS: Thirty participants who have been diagnosed with acute pulmonary embolism on CTPA underwent perfusion SPECT/CT within 24 h. Perfusion SPECT and iodine map were independently interpreted by 2 nuclear medicine physicians and 2 radiologists. For both modalities, each segment was classified as normoperfused or hypoperfused, as defined by a perfusion defect of more than 25% of a segment. The primary end point was the diagnostic accuracy (sensitivity and specificity) of iodine map for segment-based evaluation of lung perfusion, using perfusion SPECT imaging as a reference standard. Following blinded interpretation, a retrospective explanatory analysis was performed to determine potential causes of misinterpretation. RESULTS: The median time between CTPA with iodine maps and perfusion SPECT was 14 h (range 2-23 h). A total of 597 segments were analyzed. Sensitivity and specificity of iodine maps with CTPA for the detection of segmental perfusion defects were 231/284 = 81.3% (95% CI 76.4 to 85.4%) and 247/313 = 78.9% (95% CI 74.1 to 83.1%), respectively. In retrospect, false results were explained in 48.7%. CONCLUSION: Iodine map CTPA showed promising results for the assessment of pulmonary perfusion in patients with acute PE, with sensitivity of 81.3% and specificity of 78.9%, respectively. Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the accuracy of the test. KEY POINTS: • Sensitivity and specificity of iodine subtraction maps for the detection of segmental perfusion defects were 81.3% (95% CI 76.4 to 85.4%) and 78.9% (95% CI 74.1 to 83.1%), respectively. • Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the diagnostic accuracy of the test.


Assuntos
Angiografia Digital/métodos , Angiografia por Tomografia Computadorizada/métodos , Isótopos de Iodo/farmacologia , Pulmão/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Iodo , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Int J Legal Med ; 134(5): 1915-1925, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32444948

RESUMO

OBJECTIVE: Detection of explosives is a challenge due to the use of improvised and concealed bombs. Post-bomb strike bodies are handled by emergency and forensic teams. We aimed to determine whether medical dual-energy computed tomography (DECT) algorithm and prediction model can readily detect and distinguish a range of explosives on the human body during disaster victim identification (DVI) processes of bombings. MATERIALS AND METHODS: A medical DECT of 8 explosives (Semtex, Pastex, Hexamethylene triperoxide diamine, Acetone peroxide, Nitrocellulose, Pentrite, Ammonium Nitrate, and classified explosive) was conducted ex-vivo and on an anthropomorphic phantom. Hounsfield unit (HU), electron density (ED), effective atomic number (Zeff), and dual energy index (DEI),were compared by Wilcoxon signed rank test. Intra-class (ICC) and Pearson correlation coefficients (r) were computed. Explosives classification was performed through a prediction model with test-retest samples. RESULTS: Except for DEI (p = 0.036), means of HU, ED, and Zeff were not statistically different (p > 0.05) between explosives ex-vivo and on the phantom (r > 0.80). Intra- and inter-reader ICC were good to excellent: 0.806 to 0.997 and 0.890, respectively. Except for the phantom DEI, all measurements from each individual explosive differed significantly. HU, ED, Zeff, and DEI differed depending on the type of explosive. Our decision tree provided Zeff and ED for explosives classification with high accuracy (83.7%) and excellent reliability (100%). CONCLUSION: Our medical DECT algorithm and prediction model can readily detect and distinguish our range of explosives on the human body. This would avoid possible endangering of DVI staff.


Assuntos
Substâncias Explosivas/química , Substâncias Explosivas/classificação , Ciências Forenses , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Árvores de Decisões , Estudos de Viabilidade , Humanos , Modelos Anatômicos , Imagens de Fantasmas
5.
Catheter Cardiovasc Interv ; 94(2): 216-222, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30719828

RESUMO

OBJECTIVES: The aim of this study was to determine the accuracy of DoseMap™ software as compared to gafchromic film in real clinical practices. BACKGROUND: The radiation exposure from cardiovascular procedures could expose patients to potential risk of cancer and/or skin injury. New tools like Dosemap software were developed to estimate the patient skin dose in the cardiac catheterization laboratory. However, little data are available to validate this estimation of patient radiation skin dose. METHODS: This is a prospective cross-sectional study comparing the peak skin dose (PSD) measured by gafchromic film used as reference with an estimated PSD given by Dosemap software, in patients with BMI > 30 kg/m2 undergoing elective diagnostic and/or therapeutic interventional cardiology procedures, from April 2016 to December 2016, at the Brest University Hospital Centre, France. RESULTS: After four exclusions of patients for poor quality of gafchromic films, 90 patients were included, with 58 angiography (67.4%), 14 percutaneous interventions (16.3%), and 14 both (16.3%). The median PSDDosemap and PSDFilm were similar with 157 mGy [IQR: 99; 273] versus 158 mGy [IQR: 101; 295] (P = 0.65), respectively, with an excellent correlation (r = 0.95). The comparison between cumulative air kerma and PSDFilm was different 366 mGy [IQR: 246; 575] versus 158 mGy [IQR: 101; 295] (P < 0.01) with moderate correlation (r = 0.79). No correlation was found between the dose area product and PSDFilm (r = 0.51). CONCLUSION: DoseMap is an effective and valid method as compared to gafchromic films to estimate PSDs during interventional cardiologic procedures.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Intervenção Coronária Percutânea , Doses de Radiação , Exposição à Radiação , Monitoramento de Radiação/métodos , Radiografia Intervencionista , Pele/efeitos da radiação , Validação de Programas de Computador , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/efeitos adversos , Estudos Transversais , Feminino , Dosimetria Fotográfica , Humanos , Masculino , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Monitoramento de Radiação/instrumentação , Radiografia Intervencionista/efeitos adversos , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco
6.
Acta Oncol ; 57(3): 375-381, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28984165

RESUMO

PURPOSE: Inadequate clinical target volume (CTV) definition is likely to be a major contributing factor to local recurrence (LR) rate after radiotherapy. Our aims were to identify sites of prostate cancer LR in biochemical recurrence post-prostatectomy using 18F-Fluorocholine (18F-FCH) positron emission tomography/computed tomography (PET/CT) and to compare different CTV-delineation guidelines in a cohort of postoperative patients. MATERIAL AND METHODS: Thirty-six patients presenting with LR within the prostatic bed on 18F-FCH PET/CT between 10/2011 and 06/2016 were included in this retrospective study. Median PSA at the time of 18F-FCH PET/CT was 2.7 ng/mL (0.8-9.4) and median PSA doubling time was 11 months (3-28). For each patient, the CTVRTOG, CTVFROGG and CTVEORTC following the corresponding guidelines were outlined and compared. Forty-one LR were delineated using a gradient-based method and the percentage of FCH uptake included in each CTV was evaluated. RESULTS: The anastomosis was the most common recurrence site (52.8%), followed by the retrovesical region (31.7%) and the bladder neck (7%). The median SUV max value was 4.8 (2.3-16.1). The percentage of LR entirely included in the CTVRTOG was not significantly different from that included in the CTVFROGG (84% versus 83%, p = .5). Significantly more recurrences were included in the CTVRTOG volume compared to the CTVEORTC (84% versus 68%, p=.006), due to a better coverage of the bladder neck and retrovesical regions. Six out of 10 relapses occurring in the posterior region of the anastomosis were not covered by any of the CTVs. CONCLUSIONS: In our study, the CTVRTOG and CTVFROGG ensured the best coverage of LR seen on 18F-FCH PET/CT. When outlining the prostatic fossa, greater coverage of the posterior vesico-urethral region may allow better coverage of potential microscopic disease.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Colina/análogos & derivados , Radioisótopos de Flúor , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/radioterapia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Compostos Radiofarmacêuticos , Radioterapia Adjuvante/métodos , Estudos Retrospectivos , Terapia de Salvação/métodos
8.
Eur J Nucl Med Mol Imaging ; 42(13): 2072-82, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26219870

RESUMO

PURPOSE: Point-spread function (PSF) or PSF + time-of-flight (TOF) reconstruction may improve lesion detection in oncologic PET, but can alter quantitation resulting in variable standardized uptake values (SUVs) between different PET systems. This study aims to validate a proprietary software tool (EQ.PET) to harmonize SUVs across different PET systems independent of the reconstruction algorithm used. METHODS: NEMA NU2 phantom data were used to calculate the appropriate filter for each PSF or PSF+TOF reconstruction from three different PET systems, in order to obtain EANM compliant recovery coefficients. PET data from 517 oncology patients were reconstructed with a PSF or PSF+TOF reconstruction for optimal tumour detection and an ordered subset expectation maximization (OSEM3D) reconstruction known to fulfil EANM guidelines. Post-reconstruction, the proprietary filter was applied to the PSF or PSF+TOF data (PSFEQ or PSF+TOFEQ). SUVs for PSF or PSF+TOF and PSFEQ or PSF+TOFEQ were compared to SUVs for the OSEM3D reconstruction. The impact of potential confounders on the EQ.PET methodology including lesion and patient characteristics was studied, as was the adherence to imaging guidelines. RESULTS: For the 1380 tumour lesions studied, Bland-Altman analysis showed a mean ratio between PSF or PSF+TOF and OSEM3D of 1.46 (95%CI: 0.86-2.06) and 1.23 (95%CI: 0.95-1.51) for SUVmax and SUVpeak, respectively. Application of the proprietary filter improved these ratios to 1.02 (95%CI: 0.88-1.16) and 1.04 (95%CI: 0.92-1.17) for SUVmax and SUVpeak, respectively. The influence of the different confounding factors studied (lesion size, location, radial offset and patient's BMI) was less than 5%. Adherence to the European Association of Nuclear Medicine (EANM) guidelines for tumour imaging was good. CONCLUSION: These data indicate that it is not necessary to sacrifice the superior lesion detection and image quality achieved by newer reconstruction techniques in the quest for harmonizing quantitative comparability between PET systems.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Linfoma não Hodgkin/diagnóstico por imagem , Melanoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/normas , Compostos Radiofarmacêuticos
9.
Eur J Nucl Med Mol Imaging ; 41(4): 659-67, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24196922

RESUMO

PURPOSE: The objective of this study was to investigate the value of metabolic tumour volume (MTV) assessed with (18)F-FDG PET/CT in predicting event-free survival (EFS) and overall survival (OS) in patients with head and neck squamous cell carcinoma (HNSCC), and particularly to compare it with more conventional parameters such as maximum standardized uptake value (SUVmax). METHODS: Patients referred to our department for (18)F-FDG PET/CT for staging of HNSCC were prospectively included between February 2009 and March 2011. Each patient was scanned using a Philips Gemini PET/CT system at 1 h after injection. The MTV was calculated semiautomatically for the primary site using methods based on SUV with various thresholds: 3-D contour around voxels equal to or greater than 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5 and 7.0 times SUV, or more than 30%, 40% and 50% of SUVmax. ROC analysis was used to test the statistical significance of the differences among the calculated MTVs. EFS and OS were determined using the Kaplan-Meier method and compared with MTV in univariate and multivariate analyses, including the usual prognostic factors: age, sex, primary site, treatment, SCC histologic grade, AJCC stage, TNM classification, tumour SUVmax and SUVpeak. RESULTS: The study included 80 consecutive patients (70 men, 10 women; mean age 62.4 ± 9.0 years). ROC analysis revealed that pretreatment MTV using a threshold of 5.0 times SUV (MTV5.0) was the best parameter to predict recurrence and death after treatment. In univariate analysis, MTV5.0 >4.9 ml was predictive of poor EFS (p < 0.0001) and poor OS (p < 0.0001). In multivariate, MTV5.0 persisted as an independent predictive factor for EFS (p = 0.011) and OS (p = 0.010), while SUVmax became nonsignificant (p = 0.277 for EFS, p = 0.975 for OS). CONCLUSION: Our results suggest that MTV measured by (18)F-FDG PET/CT has independent prognostic value of in patients with HNSCC, stronger than SUVmax.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
11.
Int J Radiat Oncol Biol Phys ; 118(4): 952-962, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37875246

RESUMO

PURPOSE: The aim of this work was to compare anatomic and functional dose-volume parameters as predictors of acute radiation-induced lung toxicity (RILT) in patients with lung tumors treated with stereotactic body radiation therapy. METHODS AND MATERIALS: Fifty-nine patients treated with stereotactic body radiation therapy were prospectively included. All patients underwent gallium 68 lung perfusion positron emission tomography (PET)/computed tomography (CT) imaging before treatment. Mean lung dose (MLD) and volumes receiving x Gy (VxGy, 5-30 Gy) were calculated in 5 lung volumes: the conventional anatomic volume (AV) delineated on CT images, 3 lung functional volumes (FVs) defined on lung perfusion PET imaging (FV50%, FV70%, and FV90%; ie, the minimal volume containing 50%, 70%, and 90% of the total activity within the AV), and a low FV (LFV; LFV = AV - FV90%). The primary endpoint of this analysis was grade ≥2 acute RILT at 3 months as assessed with National Cancer Institute Common Terminology Criteria for Adverse Events version 5. Dose-volume parameters in patients with and without acute RILT were compared. Receiver operating characteristic curves assessing the ability of dose-volume parameters to discriminate between patients with and without acute RILT were generated, and area under the curve (AUC) values were calculated. RESULTS: Of the 59 patients, 10 (17%) had grade ≥2 acute RILT. The MLD and the VxGy in the AV and LFV were not statistically different between patients with and without acute RILT (P > .05). All functional parameters were significantly higher in acute RILT patients (P < .05). AUC values (95% CI) for MLD AV, LFV, FV50%, FV70%, and FV90% were 0.66 (0.46-0.85), 0.60 (0.39-0.80), 0.77 (0.63-0.91), 0.77 (0.64-0.91), and 0.75 (0.58-0.91), respectively. AUC values for V20Gy AV, LFV, FV50%, FV70%, and FV90% were 0.65 (0.44-0.87), 0.64 (0.46-0.83), 0.82 (0.69-0.95), 0.81 (0.67-0.96), and 0.75 (0.57-0.94), respectively. CONCLUSIONS: The predictive value of PET perfusion-based functional parameters outperforms the standard CT-based dose-volume parameters for the risk of grade ≥2 acute RILT. Functional parameters could be useful for guiding radiation therapy planning and reducing the risk of acute RILT.


Assuntos
Síndrome Aguda da Radiação , Carcinoma Pulmonar de Células não Pequenas , Gálio , Neoplasias Pulmonares , Pneumonite por Radiação , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/tratamento farmacológico , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumonite por Radiação/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Perfusão , Gálio/uso terapêutico
12.
Diagnostics (Basel) ; 13(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36832204

RESUMO

Lung stereotactic body radiotherapy (SBRT) is increasingly proposed, especially for patients with poor lung function who are not eligible for surgery. However, radiation-induced lung injury remains a significant treatment-related adverse event in these patients. Moreover, for patients with very severe COPD, we have very few data about the safety of SBRT for lung cancer. We present the case of a female with very severe chronic obstructive pulmonary disease (COPD) with a forced expiratory volume in one second (FEV1) of 0.23 L (11%), for whom a localized lung tumor was found. Lung SBRT was the only possible treatment. It was allowed and safely performed, based on a pre-therapeutic evaluation of regional lung function with Gallium-68 perfusion lung positron emission tomography combined with computed tomography (PET/CT). This is the first case report to highlight the potential use of a Gallium-68 perfusion PET/CT in order to safely select patients with very severe COPD who can benefit from SBRT.

13.
EJNMMI Phys ; 10(1): 79, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38062278

RESUMO

BACKGROUND: The aim was to investigate the feasibility of a shortened dynamic whole-body (dWB) FDG-PET/CT protocol and Patlak imaging using a population-based input function (PBIF), instead of an image-derived input function (IDIF) across the 60-min post-injection period, and study its effect on the FDG influx rate (Ki) quantification in patients with metastatic melanoma (MM) undergoing immunotherapy. METHODS: Thirty-seven patients were enrolled, including a PBIF modeling group (n = 17) and an independent validation cohort (n = 20) of MM from the ongoing prospective IMMUNOPET2 trial. All dWB-PET data were acquired on Vision 600 PET/CT systems. The PBIF was fitted using a Feng's 4-compartments model and scaled to the individual IDIF tail's section within the shortened acquisition time. The area under the curve (AUC) of PBIFs was compared to respective IDIFs AUC within 9 shortened time windows (TW) in terms of linear correlation (R2) and Bland-Altman tests. Ki metrics calculated with PBIF vs IDIF on 8 organs with physiological tracer uptake, 44 tumoral lesions of MM and 11 immune-induced inflammatory sites of pseudo-progression disease were also compared (Mann-Whitney test). RESULTS: The mean ± SD relative AUC bias was calculated at 0.5 ± 3.8% (R2 = 0.961, AUCPBIF = 1.007 × AUCIDIF). In terms of optimal use in routine practice and statistical results, the 5th-7th pass (R2 = 0.999 for both Ki mean and Ki max) and 5th-8th pass (mean ± SD bias = - 4.9 ± 6.5% for Ki mean and - 4.8% ± 5.6% for Ki max) windows were selected. There was no significant difference in Ki values from PBIF5_7 vs IDIF5_7 for physiological uptakes (p > 0.05) as well as for tumor lesions (mean ± SD Ki IDIF5_7 3.07 ± 3.27 vs Ki PBIF5_7 2.86 ± 2.96 100ml/ml/min, p = 0.586) and for inflammatory sites (mean ± SD Ki IDIF5_7 1.13 ± 0.59 vs Ki PBIF5_7 1.13 ± 0.55 100ml/ml/min, p = 0.98). CONCLUSION: Our study showed the feasibility of a shortened dWB-PET imaging protocol with a PBIF approach, allowing to reduce acquisition duration from 70 to 20 min with reasonable bias. These findings open perspectives for its clinical use in routine practice such as treatment response assessment in oncology.

14.
Cancers (Basel) ; 15(6)2023 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-36980612

RESUMO

The aim of this study was to assess the feasibility of sparing functional lung areas by integration of pulmonary functional mapping guided by 68Ga-perfusion PET/CT imaging in lung SBRT planification. Sixty patients that planned to receive SBRT for primary or secondary lung tumors were prospectively enrolled. Lung functional volumes were defined as the minimal volume containing 50% (FV50%), 70% (FV70%) and 90% (FV90%) of the total activity within the anatomical volume. All patients had a treatment planning carried out in 2 stages: an anatomical planning blinded to the PET results and then a functional planning respecting the standard constraints but also incorporating "lung functional volume" constraints. The mean lung dose (MLD) in functional volumes and the percentage of lung volumes receiving xGy (VxGy) within the lung functional volumes using both plans were calculated and compared. SBRT planning optimized to spare lung functional regions led to a significant reduction (p < 0.0001) of the MLD and V5 to V20 Gy in all functional volumes. Median relative difference of the MLD in the FV50%, FV70% and FV90% was -8.0% (-43.0 to 1.2%), -7.1% (-34.3 to 1.2%) and -5.7% (-22.3 to 4.4%), respectively. Median relative differences for VxGy ranged from -12.5% to -9.2% in the FV50%, -11.3% to -7.2% in the FV70% and -8.0% to -5.3% in the FV90%. This study shows the feasibility of significantly decreasing the doses delivered to the lung functional volumes using 68Ga-perfusion PET/CT while still respecting target volume coverage and doses to other organs at risk.

15.
Cancers (Basel) ; 15(7)2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37046827

RESUMO

BACKGROUND: Gallium-68 lung perfusion PET/CT is an emerging imaging modality for the assessment of regional lung function, especially to optimise radiotherapy (RT) planning. A key step of lung functional avoidance RT is the delineation of lung functional volumes (LFVs) to be integrated into radiation plans. However, there is currently no consistent and reproducible delineation method for LFVs. The aim of this study was to develop and evaluate an automated delineation threshold method based on total lung function for LFVs delineation with Gallium-68 MAA lung PET/CT imaging. MATERIAL AND METHOD: Patients prospectively enrolled in the PEGASUS trial-a pilot study assessing the feasibility of lung functional avoidance using perfusion PET/CT imaging for lung stereotactic body radiotherapy (SBRT) of primary or secondary lesion-were analysed. Patients underwent lung perfusion MAA-68Ga PET/CT imaging and pulmonary function tests (PFTs) as part of pre-treatment evaluation. LFVs were delineated using two methods: the commonly used relative to the maximal pixel value threshold method (pmax threshold method, X%pmax volumes) and a new approach based on a relative to whole lung function threshold method (WLF threshold method, FVX% volumes) using a dedicated iterative algorithm. For both methods, LFVs were expressed in terms of % of the anatomical lung volume (AV) and of % of the total lung activity. Functional volumes were compared for patients with normal PFTs and pre-existing airway disease. RESULTS: 60 patients were analysed. Among the 48 patients who had PFTs, 31 (65%) had pre-existing lung disease. The pmax and WLF threshold methods clearly provided different functional volumes with a wide range of relative lung function for a given pmax volume, and conversely, a wide range of corresponding pmax values for a given WLF volume. The WLF threshold method provided more reliable and consistent volumes with much lower dispersion of LFVs as compared to the pmax method, especially in patients with normal PFTs. CONCLUSIONS: We developed a relative to whole lung function threshold segmentation method to delineate lung functional volumes on perfusion PET/CT imaging. The automated algorithm allows for reproducible contouring. This new approach, relatively unaffected by the presence of hot spots, provides reliable and consistent functional volumes, and is clinically meaningful for clinicians.

16.
Sci Rep ; 13(1): 5789, 2023 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-37031233

RESUMO

The main aim of this study was to evaluate the prognostic value of radiomic approach in pre-therapeutic 18F-fluorodeoxyglucose positron-emission tomography (FDG-PET/CT) in a large cohort of patients with gastro-esophageal junction cancer (GEJC). This was a retrospective monocenter study including 97 consecutive patients with GEJC who underwent a pre-therapeutic FDG-PET and were followed up for 3 years. Standard first-order radiomic PET indices including SUVmax, SUVmean, SUVpeak, MTV and TLG and 32 textural features (TFs) were calculated using LIFEx software on PET imaging. Prognostic significance of these parameters was assessed in univariate and multivariate analysis. Relapse-free survival (RFS) and overall survival (OS) were respectively chosen as primary and secondary endpoints. An internal validation cohort was used by randomly drawing one-third of included patients. The main characteristics of this cohort were: median age of 65 years [41-88], sex ratio H/F = 83/14, 81.5% of patients with a histopathology of adenocarcinoma and 43.3% with a stage IV disease. The median follow-up was 28.5 months [4.2-108.5]. Seventy-seven (79.4%) patients had locoregional or distant progression or recurrence and 71 (73.2%) died. In univariate analysis, SUVmean, Histogram-Entropy and 2 TFs (GLCM-Homogeneity and GLCM-Energy) were significantly correlated with RFS and OS, as well as 2 others TFs (GLRLM-LRE and GLRLM-GLNU) with OS only. In multivariate analysis, Histogram-Entropy remained an independent prognostic factor of both RFS and OS whereas SUVmean was an independent prognostic factor of OS only. These results were partially confirmed in our internal validation cohort of 33 patients. Our results suggest that radiomic approach reveals independent prognostic factors for survival in patients with GEJC.


Assuntos
Adenocarcinoma , Neoplasias Esofágicas , Junção Esofagogástrica , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Gástricas , Idoso , Humanos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/mortalidade , Neoplasias Esofágicas/terapia , Fluordesoxiglucose F18 , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Prognóstico , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/mortalidade , Neoplasias Gástricas/terapia , Carga Tumoral , Junção Esofagogástrica/diagnóstico por imagem , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/mortalidade , Adenocarcinoma/terapia , Período Pré-Operatório
17.
Cancers (Basel) ; 15(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36612093

RESUMO

The standard therapy strategy for high-grade glioma (HGG) is based on the maximal surgery followed by radio-chemotherapy (RT-CT) with insufficient control of the disease. Recurrences are mainly localized in the radiation field, suggesting an interest in radiotherapy dose escalation to better control the disease locally. We aimed to identify a similarity between the areas of high uptake on O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) positron emission tomography/computed tomography (PET) before RT-CT, the residual tumor on post-therapy NADIR magnetic resonance imaging (MRI) and the area of recurrence on MRI. This is an ancillary study from the IMAGG prospective trial assessing the interest of FET PET imaging in RT target volume definition of HGG. We included patients with diagnoses of HGG obtained by biopsy or tumor resection. These patients underwent FET PET and brain MRIs, both after diagnosis and before RT-CT. The follow-up consisted of sequential brain MRIs performed every 3 months until recurrence. Tumor delineation on the initial MRI 1 (GTV 1), post-RT-CT NADIR MRI 2 (GTV 2), and progression MRI 3 (GTV 3) were performed semi-automatically and manually adjusted by a neuroradiologist specialist in neuro-oncology. GTV 2 and GTV 3 were then co-registered on FET PET data. Tumor volumes on FET PET (MTV) were delineated using a tumor to background ratio (TBR) ≥ 1.6 and different % SUVmax PET thresholds. Spatial similarity between different volumes was performed using the dice (DICE), Jaccard (JSC), and overlap fraction (OV) indices and compared together in the biopsy or partial surgery group (G1) and the total or subtotal surgery group (G2). Another overlap index (OV') was calculated to determine the threshold with the highest probability of being included in the residual volume after RT-CT on MRI 2 and in MRI 3 (called "hotspot"). A total of 23 patients were included, of whom 22% (n = 5) did not have a NADIR MRI 2 due to a disease progression diagnosed on the first post-RT-CT MRI evaluation. Among the 18 patients who underwent a NADIR MRI 2, the average residual tumor was approximately 71.6% of the GTV 1. A total of 22% of patients (5/23) showed an increase in GTV 2 without diagnosis of true progression by the multidisciplinary team (MDT). Spatial similarity between MTV and GTV 2 and between MTV and GTV 3 were higher using a TBR ≥ 1.6 threshold. These indices were significantly better in the G1 group than the G2 group. In the FET hotspot analysis, the best similarity (good agreement) with GTV 2 was found in the G1 group using a 90% SUVmax delineation method and showed a trend of statistical difference with those (poor agreement) in the G2 group (OV' = 0.67 vs. 0.38, respectively, p = 0.068); whereas the best similarity (good agreement) with GTV 3 was found in the G1 group using a 80% SUVmax delineation method and was significantly higher than those (poor agreement) in the G2 group (OV'= 0.72 vs. 0.35, respectively, p = 0.014). These results showed modest spatial similarity indices between MTV, GTV 2, and GTV 3 of HGG. Nevertheless, the results were significantly improved in patients who underwent only biopsy or partial surgery. TBR ≥ 1.6 and 80-90% SUVmax FET delineation methods showing a good agreement in the hotspot concept for targeting standard dose and radiation boost. These findings need to be tested in a larger randomized prospective study.

18.
Front Med (Lausanne) ; 9: 831457, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35223928

RESUMO

BACKGROUND: The use of 18FDG-PET/CT for delineating a gross tumor volume (GTV, also called MTV metabolic tumor volume) in radiotherapy (RT) planning of head neck squamous cell carcinomas (HNSCC) is not included in current recommendations, although its interest for the radiotherapist is of evidence. Because pre-RT PET scans are rarely done simultaneously with dosimetry CT, the validation of a robust image registration tool and of a reproducible MTV delineation method is still required. OBJECTIVE: Our objective was to study a CT-based elastic registration method on dual-time pre-RT 18FDG-PET/CT images to assess the feasibility of PET-based RT planning in patients with HNSCC. METHODS: Dual-time 18FDG-PET/CT [whole-body examination (wbPET) + 1 dedicated step (headPET)] were selected to simulate a 2-times scenario of pre-RT PET images deformation on dosimetry CT. ER-headPET and RR-headPET images were, respectively, reconstructed after CT-to-CT rigid (RR) and elastic (ER) registrations of the headPET on the wbPET. The MTVs delineation was performed using two methods (40%SUVmax, PET-Edge). The percentage variations of several PET parameters (SUVmax, SUVmean, SUVpeak, MTV, TLG) were calculated between wbPET, ER-headPET, and RR-headPET. Correlation between MTV values was calculated (Deming linear regression). MTVs intersections were assessed by two indices (OF, DICE) and compared together (Wilcoxon test). Additional per-volume analysis was evaluated (Mann-Whitney test). Inter- and intra-observer reproducibilities were evaluated (ICC = intra-class coefficient). RESULTS: 36 patients (30M/6F; median age = 65 y) were retrospectively included. The changes in SUVmax, SUVmean and SUVpeak values between ER-headPET and RR-headPET images were <5%. The variations in MTV values between ER-headPET and wbPET images were -6 and -3% with 40%SUVmax and PET Edge, respectively. Their correlations were excellent whatever the delineation method (R2 > 0.99). The ER-headPET MTVs had significant higher mean OF and DICE with the wbPET MTVs, for both delineation methods (p ≤ 0.002); and also when lesions had a volume > 5cc (excellent OF = 0.80 with 40%SUVmax). The inter- and intra-observer reproducibilities for MTV delineation were excellent (ICC ≥ 0.8, close to 1 with PET-Edge). CONCLUSION: Our study demonstrated no significant changes in MTV after an elastic deformation of pre-RT 18FDG-PET/CT images acquired in dual-time mode. This opens possibilities for HNSCC radiotherapy planning improvement by transferring GTV-PET on dosimetry CT.

19.
Clin Nucl Med ; 46(6): 499-500, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33795588

RESUMO

ABSTRACT: Glioma stem cells (GSCs) are the source of tumor recurrence in glioblastoma and are capable of whole tumor regeneration once the treatment has concluded. Compelling evidence from the last decade suggests that GSC may arise from neural stem cells residing in the adult subventricular zone (SVZ). We report the findings of an 18F-FET PET/CT showing pathological uptake in SVZ with a tumor-background ratio of greater than 1.6, giving evidence for glioblastoma recurrence. This case highlights the particular attention to be paid to the SVZ given the possible development of GSC.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioblastoma/diagnóstico por imagem , Ventrículos Laterais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tirosina/análogos & derivados , Adulto , Neoplasias Encefálicas/patologia , Feminino , Glioblastoma/patologia , Humanos , Ventrículos Laterais/patologia , Recidiva
20.
EJNMMI Phys ; 8(1): 49, 2021 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-34224005

RESUMO

BACKGROUND: In patients with pulmonary embolism (PE), there is a growing interest in quantifying the pulmonary vascular obtruction index (PVOI), which may be an independent risk factor for PE recurrence. Perfusion SPECT/CT is a very attractive tool to provide an accurate quantification of the PVOI. However, there is currently no reliable method to automatically delineate and quantify it. The aim of this phantom study was to assess and compare 3 segmentation methods for PVOI quantification with perfusion SPECT/CT imaging. METHODS: Three hundred ninety-six SPECT/CT scans, with various PE scenarios (n = 44), anterior to posterior perfusion gradients (n = 3), and lung volumes (n = 3) were simulated using Simind software. Three segmentation methods were assesssed: (1) using an intensity threshold expressed as a percentage of the maximal voxel value (MaxTh), (2) using a Z-score threshold (ZTh) after building a Z-score parametric lung map, and (3) using a relative difference threshold (RelDiffTh) after building a relative difference parametric map. Ninety randomly selected simulations were used to define the optimal threshold, and 306 simulations were used for the complete analysis. Spacial correlation between PE volumes from the phantom data and the delineated PE volumes was assessed by computing DICEPE indices. Bland-Altman statistics were used to calculate agreement for PVOI between the phantom data and the segmentation methods. RESULTS: Mean DICEPE index was higher with the RelDiffTh method (0.85 ± 0.08), as compared with the MaxTh method (0.78 ± 0.16) and the ZTh method (0.67 ± 0.15). Using the RelDiffTh method, mean DICEPE index remained high (> 0.81) regardless of the perfusion gradient and the lung volumes. Using the RelDiffTh method, mean relative difference in PVOI was - 12%, and the limits of agreement were - 40% to 16%. Values were 3% (- 75% to 81%) for MaxTh method and 0% (- 120% to 120%) for ZTh method. Graphycal analysis of the Bland-Altman graph for the RelDiffTh method showed very close estimation of the PVOI for small and medium PE, and a trend toward an underestimation of large PE. CONCLUSION: In this phantom study, a delineation method based on a relative difference parametric map provided a good estimation of the PVOI, regardless of the extent of PE, the intensity of the anterior to posterior gradient, and the whole lung volumes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA