Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Virol ; 87(10): 6055-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23514886

RESUMO

Progressive multifocal leukoencephalopathy (PML) is the main adverse effect of natalizumab. Detectable JC virus-specific effector memory T-cell (TEM) responses may indicate ongoing JCV replication. We detected JCV-specific TEM responses in blood of patients with multiple sclerosis (MS) treated with natalizumab, including 2 patients with PML. The frequency of detection of these responses increased with the time on natalizumab. Thus, a subset of MS patients exhibit immunological hallmarks of JCV replication during prolonged natalizumab therapy.


Assuntos
Anticorpos Monoclonais Humanizados/efeitos adversos , Produtos Biológicos/efeitos adversos , Fatores Imunológicos/efeitos adversos , Vírus JC/imunologia , Esclerose Múltipla/tratamento farmacológico , Esclerose Múltipla/imunologia , Replicação Viral , Adulto , Anticorpos Monoclonais Humanizados/administração & dosagem , Produtos Biológicos/administração & dosagem , Feminino , Humanos , Fatores Imunológicos/administração & dosagem , Vírus JC/fisiologia , Pessoa de Meia-Idade , Esclerose Múltipla/virologia , Natalizumab , Linfócitos T/imunologia
2.
Ann Biol Clin (Paris) ; 78(4): 454-460, 2020 08 01.
Artigo em Francês | MEDLINE | ID: mdl-32616472

RESUMO

Blood angiotensin-converting enzyme (ACE) assay is now realized by the determination of enzyme activity on synthetic substrate, mostly furylacryloyl-phenylalanyl-L-glycyl-L-glycine (FAPGG). The matrix can be serum or heparin-plasma, with or without a separator; the assay developed on serum or plasma is not adapted to other matrix such as cerebrospinal fluid where the ACE activity is much lower. This assay has been adapted on a number of automated biochemistry analyzers with the specifications of the supplier of reagents, sometimes with modification of volumes or times for analysis. Samples can be stored at +4̊C for at least for one week, freezing at -20̊C is possible but refreezing is not advised. The assay is linear from 10 to 200 UI/L. Fidelity is excellent after calibration of the assay. Accuracy can be calculated from IQA and EQA results, and the analytical uncertainty is between 2% and 5% in function of the serum ACE value. Usual values will be soon available from studies on age brackets and sex, because ACE activity seems to be more elevated in boys during adolescence. At signature, it is interesting to have medical information on the diagnosis of sarcoidosis or its treatment including ACE inhibitors as a proof of intake; we can give a commentary on elevation of serum ACE activity from other causes than sarcoidosis and the causes for low activities.


Assuntos
Análise Química do Sangue/métodos , Peptidil Dipeptidase A/análise , Peptidil Dipeptidase A/sangue , Biomarcadores/análise , Biomarcadores/sangue , Análise Química do Sangue/normas , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas , Granuloma/sangue , Granuloma/diagnóstico , Granuloma/terapia , Humanos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Fase Pré-Analítica , Reprodutibilidade dos Testes , Sarcoidose/sangue , Sarcoidose/diagnóstico , Sarcoidose/terapia , Sensibilidade e Especificidade , Estudos de Validação como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA