Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Clin Oncol (R Coll Radiol) ; 20(4): 293-300, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18234482

RESUMO

AIMS: Radical radiotherapy for stage II/III non-small cell lung cancer (NSCLC) includes the primary tumour and positive mediastinal lymph nodes in the clinical target volume (CTV). These move independently of each other in magnitude and direction during respiration. To prevent a geographical miss, a generic margin is usually added to the CTV to create an internal target volume (ITV). Previous studies have investigated the use of additional breath-hold computed tomography to generate patient-specific ITVs for primary tumours alone. We used a similar technique to investigate the generation of patient-specific and generic ITVs for CTVs that include mediastinal lymph nodes. MATERIALS AND METHODS: Thirteen patients with node-positive NSCLC had two limited end-tidal breath-hold computed tomography scans in addition to their planning computed tomography. The CTV was segmented in each scan and a rigid registration was carried out on the vertebral columns to align them. Different methods for generating an ITV were then analysed. RESULTS: Generic margins provided >95% mean coverage of the reference ITV. However, with the exception of 1cm expansion margins, there were cases of inadequate coverage (<95%) for each ITV. With increasing ITV margins there was a small increase in reference ITV coverage, but at the expense of a large increase in the volume of normal tissue within the ITV. DISCUSSION: For stage II/III NSCLC, ITV generation by the addition of a generic margin is not optimal. It can result in both geographical miss and excessive irradiation of normal tissue in the same treatment plan. A simple method for producing a patient-specific ITV is to co-register end-tidal breath-hold computed tomography scans to the planning scan. CONCLUSIONS: Further work is required to determine whether end-tidal breath-hold scans are representative of the anatomy at the limits of tidal respiration. Planning strategies are also needed to account for breathing cycle variation during a course of radiotherapy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Metástase Linfática , Masculino , Mediastino , Pessoa de Meia-Idade , Radiografia , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA