Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmic Physiol Opt ; 44(1): 199-205, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897105

RESUMO

PURPOSE: Accumulated axial growth observed during a 6-year clinical trial of a dual focus myopia control contact lens was used to explore different approaches to assess treatment efficacy. METHODS: Axial length measurements from 170 eyes in a 6-year clinical trial of a dual focus myopia control lens (MiSight 1 day, CooperVision) were analysed. Treatment groups comprised one having undergone 6 years of treatment and the other (the initial control group) having 3 years of treatment after 3 years of wearing a single vision control lens. Efficacy was assessed by comparing accumulated ocular growth during treatment to that expected of untreated myopic and emmetropic eyes. The impact of treatment on delaying axial growth was quantified by comparing the increased time required to reach criterion growths for treated eyes and survivor analysis approaches. RESULTS: When compared to the predicted accumulated growth of untreated eyes, 6 years of treatment reduced growth by 0.52 mm, while 3 years of treatment initiated 3 years later reduced growth by 0.19 mm. Accumulated differences between the growth of treated and untreated myopic eyes ranged between 67% and 52% of the untreated myopic growth, and between 112% and 86% of the predicted difference in growth between untreated myopic and age-matched emmetropic eyes. Treated eyes took almost 4 years longer to reach their final accumulated growth than untreated eyes. Treatment increased the time to reach criterion growths by 2.3-2.7 times. CONCLUSION: Estimated growth of age-matched emmetropic and untreated myopic eyes provided evidence of an accumulated slowing in axial elongation of 0.52 mm over 6 years, and the treated growth remained close to that expected of emmetropic eyes. Six years of dual focus myopia control delayed the time to reach the final growth level by almost 4 years.


Assuntos
Lentes de Contato , Miopia , Humanos , Comprimento Axial do Olho , Olho , Miopia/prevenção & controle , Refração Ocular , Resultado do Tratamento , Ensaios Clínicos como Assunto
2.
Optom Vis Sci ; 100(6): 376-387, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37097975

RESUMO

PURPOSE: This study examined the optical impact of a DF contact lens during near viewing in a sample of habitual DF lens wearing children. METHODS: Seventeen myopic children aged 14 to 18 years who had completed 3 or 6 years of treatment with a DF contact lens (MiSight 1 Day; CooperVision, Inc., San Ramon, CA) were recruited and fit bilaterally with the DF and a single-vision (Proclear 1 Day; CooperVision, Inc.) contact lens. Right eye wavefronts were measured using a pyramidal aberrometer (Osiris; CSO, Florence, Italy) while children accommodated binocularly to high-contrast letter stimuli at five target vergences. Wavefront error data were used to compute pupil maps of refractive state. RESULTS: During near viewing, children wearing single-vision lenses accommodated on average to achieve approximate focus in the pupil center but, because of combined accommodative lag and negative spherical aberration, experienced up to 2.00 D of hyperopic defocus in the pupil margins. With DF lenses, children accommodated similarly achieving approximate focus in the pupil center. When viewing three near distances (0.48, 0.31, and 0.23 m), the added +2.00 D within the DF lens treatment optics shifted the mean defocus from +0.75 to -1.00 D. The DF lens reduced the percentage of hyperopic defocus (≥+0.75 D) in the retinal image from 52 to 25% over these target distances, leading to an increase in myopic defocus (≤-0.50 D) from 17 to 42%. CONCLUSIONS: The DF contact lens did not alter the accommodative behavior of children. The treatment optics introduced myopic defocus and decreased the amount of hyperopically defocused light in the retinal image.


Assuntos
Lentes de Contato , Hiperopia , Miopia , Criança , Humanos , Miopia/complicações , Refração Ocular , Lentes de Contato/efeitos adversos , Testes Visuais , Pupila
3.
Optom Vis Sci ; 99(3): 204-212, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35086120

RESUMO

SIGNIFICANCE: Treatment of myopic children with a dual-focus soft contact lens (DFCL; MiSight 1 day) produced sustained slowing of myopia progression over a 6-year period. Significant slowing was also observed in children switched from a single vision control to treatment lenses (3 years in each lens). PURPOSE: This study aimed to evaluate the effectiveness of DFCLs in sustaining slowed progression of juvenile-onset myopia over a 6-year treatment period and assess myopia progression in children who were switched to a DFCL at the end of year 3. METHODS: Part 1 was a 3-year clinical trial comparing DFCLs with a control contact lens (Proclear 1 day) at four investigational sites. In part 2, subjects completing part 1 were invited to continue for 3 additional years during which all children were treated with MiSight 1 day DFCLs (52 and 56 from the initially treated [T6] and control [T3] groups, respectively). Eighty-five subjects (45 [T3] and 40 [T6]) completed part 2. Cyclopleged spherical equivalent refractive errors (SEREs) and axial lengths (ALs) were monitored, and a linear mixed model was used to compare their adjusted change annually. RESULTS: Average ages at part 2 baseline were 13.2 ± 1.3 and 13.0 ± 1.5 years for the T6 and T3 groups, respectively. Slowed myopia progression in the T6 group observed during part 1 was sustained throughout part 2 (mean ± standard error of the mean: change from baseline SERE [in diopters], -0.52 ± 0.076 vs. -0.51 ± 0.076; change in AL [in millimeters], 0.28 ± 0.033 vs. 0.23 ± 0.033; both P > .05). Comparing progression rates in part 2 for the T6 and T3 groups, respectively, indicates that prior treatment does not influence efficacy (SERE, -0.51 ± 0.076 vs. -0.34 ± 0.077; AL, 0.23 ± 0.03 vs. 0.18 ± 0.03; both P > .05). Within-eye comparisons of AL growth revealed a 71% slowing for the T3 group (3 years older than part 1) and further revealed a small subset of eyes (10%) that did not respond to treatment. CONCLUSIONS: Dual-focus soft contact lenses continue to slow the progression of myopia in children over a 6-year period revealing an accumulation of treatment effect. Eye growth of the initial control cohort with DFCL was slowed by 71% over the subsequent 3-year treatment period.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Comprimento Axial do Olho , Criança , Progressão da Doença , Humanos , Miopia/diagnóstico , Miopia/terapia , Refração Ocular , Visão Ocular
4.
Ophthalmic Physiol Opt ; 42(5): 1074-1091, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35620968

RESUMO

Monocular polyplopia (ghost or multiple images) is a serious visual impediment for some people who report seeing two (diplopia), three (triplopia) or even more images. Polyplopia is expected to appear if the point spread function (PSF) has multiple intensity cores (a dense concentration of a large portion of the radiant flux contained in the PSF) relatively separated from each other, each of which contributes to a distinct image. We present a theory that assigns these multiple PSF cores to specific features of aberrated wavefronts, thereby accounting optically for the perceptual phenomenon of monocular polyplopia. The theory provides two major conclusions. First, the most likely event giving rise to multiple PSF cores is the presence of hyperbolic, or less probably elliptical, umbilic caustics (using the terminology of catastrophe optics). Second, those umbilic caustics formed on the retinal surface are associated with certain points of the wave aberration function, called cusps of Gauss, where the gradient of a curvature function vanishes. However, not all cusps of Gauss generate those umbilic caustics. We also provide necessary conditions for those cusps of Gauss to be fertile. To show the potential of this theoretical framework for understanding the nature and origin of polyplopia, we provide specific examples of ocular wave aberration functions that induce diplopia and triplopia. The polyplopia effects in these examples are illustrated by depicting the multi-core PSFs and the convolved retinal images for clinical letter charts, both through computer simulations and through experimental recording using an adaptive optics set-up. The number and location of cores in the PSF is thus a potentially useful metric for the existence and severity of polyplopia in spatial vision. These examples also help explain why physiological pupil constriction might reduce the incidence of ghosting and multiple images of daily objects that affect vision with dilated pupils. This mechanistic explanation suggests a possible role for optical phase-masking as a clinical treatment for polyplopia and ghosting.


Assuntos
Cáusticos , Diplopia , Humanos , Óptica e Fotônica , Retina , Visão Ocular
5.
Ophthalmic Physiol Opt ; 41(1): 73-83, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33150654

RESUMO

PURPOSE: To examine the pupil and visual impact of a single early morning drop of a low concentration miotic. METHODS: Pupil size, refraction, visual acuity (VA), near reading performance and intraocular pressure were monitored for 8 h at a wide range of light levels following bilateral instillation of single drops of 0.1% brimonidine tartate in 19 early presbyopes (40-50 years) and 11 mature presbyopes (>50 years). RESULTS: Pupil miosis did not alter distance VA or refraction. Significant pupil miosis peaked at 1-2 h after dosing, which expanded the depth of focus of mature presbyopes with the mean improvement in near logMAR VA of -0.15, -0.07 and -0.03, at 20, 200 and 2000 lux, respectively. One hour after instillation, near reading speed improved by 21, 24 and 5 words per min for text size commonly seen in US newspaper and cellphone text messages, 18, 21 and 19 words per min for text size of grocery labels and 12, 13 and 30 words per min for text size of over-the-counter medications at light levels of 20, 200 and 2000 lux, respectively. No such improvements in near VA and near reading speed were observed in the young presbyopes having some residual accommodation. Most of the pupil miosis remained 8 h after instillation, whereas near VA improvements disappeared after 4 h. CONCLUSION: Low dose miotics can enhance near vision in presbyopic subjects while retaining high quality distance vision over a wide range of light levels. Significant improvements in near vision were observed only during the 1-2 h period after dosing when miosis peaked.


Assuntos
Acomodação Ocular/efeitos dos fármacos , Agonistas de Receptores Adrenérgicos alfa 2/administração & dosagem , Tartarato de Brimonidina/administração & dosagem , Presbiopia/fisiopatologia , Pupila/efeitos dos fármacos , Refração Ocular/efeitos dos fármacos , Adulto , Feminino , Humanos , Pressão Intraocular/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Leitura , Fatores de Tempo , Acuidade Visual/efeitos dos fármacos
6.
Optom Vis Sci ; 97(8): 628-640, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32833406

RESUMO

SIGNIFICANCE: The prevalence of myopia and use of electronic displays by children has grown rapidly in recent years. We found that children viewing electronic displays, however, experience hyperopic defocus levels similar to those previously reported for other stimuli. PURPOSE: This study aimed to compare accommodative behavior of nonmyopic and myopic children viewing a computer screen or mobile phone. METHODS: Accommodative behavior was examined in 11 nonmyopic and 8 myopic children (11.32 ± 2.90 and 14.13 ± 2.30 years, respectively; P = .04; refractions, +0.51 ± 0.51 and -2.54 ± 1.29, respectively) using an open-field autorefractor (Grand Seiko) at target vergences from -0.25 to -5.00 D. Different size (scaled or nonscaled) and type (text or movie) stimuli were presented on an LCD monitor (distant) or an iPhone (near), with subjects viewing monocularly or binocularly in an illuminated or dark room. RESULTS: At the typical reading distances (20 and 33 cm), all 19 children exhibited some amount of accommodative lag. Stimulus type had little impact on accommodation. However, slightly but statistically significant lower slopes were observed (Bonferroni-corrected significance level of P ≤ .01) for low room lighting (0.96 vs. 0.91; t test, t = 3.88; P = .003), nonscaled targets (0.99 vs. 0.92; t test, t = 4.28; P = .001), and monocular viewing (0.99 vs. 0.90; t test, t = 4.0; P = .002) in the nonmyopic group only. When viewing nonscaled stimuli binocularly (natural viewing), the means and standard deviations of accommodative lags (averaged across room lights on and off, and text and movie) were generally larger for the nonmyopes at all distances and were largest at 33 cm (0.73 ± 0.18 D for the nonmyopes and 0.49 ± 0.23 for the myopes; t test, t = 2.62; P = .01). CONCLUSIONS: Generally small (≤0.50 D) amounts of hyperopic defocus are present in children binocularly viewing handheld electronic devices (nonmyopes slightly more than myopes). Modern electronic devices do not expose children to unusually high levels of hyperopic defocus.


Assuntos
Acomodação Ocular/fisiologia , Apresentação de Dados , Hiperopia/fisiopatologia , Retina/fisiologia , Smartphone/instrumentação , Adolescente , Criança , Feminino , Humanos , Masculino , Miopia/fisiopatologia , Refração Ocular/fisiologia , Visão Binocular/fisiologia
7.
Ophthalmic Physiol Opt ; 40(5): 549-556, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32808381

RESUMO

PURPOSE: High sampling density optical metrology combined with pupil- and image-plane numerical analyses were applied to evaluate a novel spectacle lens containing multiple small zones designed to slow myopia progression. METHODS: High-resolution aberrometry (ClearWave, www.lumetrics.com) was used to sample wavefront slopes of a novel spectacle lens, Defocus Incorporated Multiple Segments (DIMS) (www.hoya.com), incorporating many small, positive-powered lenslets in its periphery. Using wavefront slope and error maps, custom MATLAB software ('Indiana Wavefront Analyzer') was used to compute image-plane point-spread functions (PSF), modulation transfer functions (MTF), simulated images and power distributions created by the dual-focus optic for different pupil sizes and target vergences. RESULTS: Outside of a central 10 mm zone containing single distance optical power, a hexagonal array of small 1 mm lenslets with nearest-neighbour separations of 0.5 mm were distributed over the lens periphery. Sagittal and curvature-based measures of optical power imperfectly captured the consistent +3.50 D add produced by the lenslets. Image plane simulations revealed multiple PSFs and poor image quality at the lenslet focal plane. Blur at the distance optic focal plane was consistent with a combination of diffraction blur from the distance optic and the approximately +3.50 D of defocus from the 1 mm diameter near optic zones. CONCLUSION: Converging the defocused beams generated by the multiple small (1 mm diameter) lenslets to a blurred image at the distance focal plane produced a blur magnitude determined by the small lenslet diameter and not the overall pupil diameter. The distance optic located in between the near-add lenslets determines the limits of the optical quality achievable by the lens. When compared to the optics of a traditional concentric-zone dual-focus contact lens, the optics of the DIMS lens generates higher-contrast images at low spatial frequencies (<7 cycles per degree), but lower-contrast at high spatial frequencies.


Assuntos
Lentes de Contato , Óculos , Miopia/terapia , Óptica e Fotônica , Refração Ocular/fisiologia , Acuidade Visual , Aberrometria , Desenho de Equipamento , Humanos , Miopia/fisiopatologia
8.
Ophthalmic Physiol Opt ; 40(1): 47-59, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31879995

RESUMO

PURPOSE: To examine the impact of monovision on dynamic changes in accommodation, pupil responses, spherical aberration and resultant image quality in early presbyopes. METHODS: Refractive state, pupil size and spherical aberration levels were monitored in nine early presbyopes who exhibited some accommodation (40-50 years, mean = 42 ± 2.37 years) using a Shack-Hartmann aberrometer as a binocularly viewed stimulus stepped closer (from 2 m to 40 cm), or farther (from 40 cm to 2 m). Comparison data from two fully presbyopic (i.e. non-accommodating) subjects (ages 46 and 61 years) and two young adults (ages 26 and 29 years) were also collected. Each subject was fit with four different refractive strategies: (1) both eyes corrected for 2 m, (2) both eyes corrected for 40 cm, (3) monovision with the measured right eye corrected for 2 m and, (4) monovision with the right eye corrected for 40 cm. Monochromatic image quality was quantified using the AreaMTF metric. RESULTS: When fit with monovision, the largest number of early presbyopes produce an accommodative response dominated by the right eye correction (distance or near) as the stimulus is abruptly changed from the retinal conjugate plane of one eye to that of the other eye. However, the accommodative responses in some early presbyopes were always dominated by the distance corrected eye, the near corrected eye, or by convergence. When the stimulus approached, the near corrected eye experienced high image quality only if there was no accommodative response. However, reduced image quality was observed if an accommodative response was initiated. Neither accommodation nor pupil response latencies were longer with monovision corrections compared with bilateral distance corrections (p > 0.05). In the early presbyopes, spherical aberration was reduced during near viewing, but primarily due to pupil miosis and not lens shape changes. CONCLUSION: As the stimulus was abruptly changed from the retinal conjugate plane of the distance corrected eye to that of the near corrected eye, most early presbyopes fit with monovision accommodated, which resulted in a decline, not an increase in image quality in the near corrected eye. These results reveal a non-optimal accommodative strategy in early presbyopes fit with monovision.


Assuntos
Acomodação Ocular/fisiologia , Presbiopia/fisiopatologia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Visão Monocular/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pupila/fisiologia
9.
J Vis ; 20(10): 7, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33007081

RESUMO

We investigated the classical question of why visual acuity decreases with decreasing retinal illuminance by holding retinal eccentricity fixed while illumination varied. Our results indicate that acuity is largely independent of illuminance at any given retinal location, which suggests that under classical free-viewing conditions acuity improves as illumination increases from rod threshold to rod saturation because the retinal location of the stimulus is permitted to migrate from a peripheral location of maximum sensitivity but poor acuity to the foveal location of maximum acuity but poor sensitivity. Comparison with anatomical sampling density of retinal neurons suggests that mesopic acuity at all eccentricities and scotopic acuity for eccentricities beyond about 20° is limited by the spacing of midget ganglion cells. In central retina, however, scotopic acuity is further limited by spatial filtering due to spatial summation within the large, overlapping receptive fields of the A-II class of amacrine cells interposed in the rod pathway between rod bipolars and midget ganglion cells. Our results offer a mechanistic interpretation of the clinical metrics for low-luminance visual dysfunction used to monitor progression of retinal disease.


Assuntos
Retina/fisiologia , Acuidade Visual/fisiologia , Campos Visuais , Humanos , Iluminação , Estimulação Luminosa/métodos
10.
J Opt Soc Am A Opt Image Sci Vis ; 36(4): B35-B43, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31044953

RESUMO

Visual detection of small black objects surrounded by a light background depends on background luminance, pupil size, optical blur, and object size. Holding pupil and optics fixed, we measured the minimum background luminance needed for foveal detection of small black targets as a function of target size. For all three observers, absolute threshold varied inversely with target area when disk diameter subtended less than 10' of visual angle. For target diameter ≥10', threshold remained constant at about 0.3 Td, which was also the absolute threshold for detecting light spots 10' or larger in diameter on a black background. These results are consistent with Ricco's law of spatial summation: a "black hole" is just detectable when the background luminance is sufficiently high for its absence inside the Ricco area to reduce 555 nm photon flux by 7500 photons/s, which is the same change needed to detect light spots on a black surround. These results can be accounted for by a differential pair of Ricco detectors, each about the size of the receptive field center of magocellular retinal ganglion cells when projected into object space through the eye's weakly aberrated optical system. Statistical analysis of the model suggests the quantum fluctuations due to internal, biological noise (i.e., "scotons") are a greater handicap than the photon fluctuations inherent in the light stimulus at absolute foveal threshold.


Assuntos
Escuridão , Fóvea Central/fisiologia , Limiar Sensorial/efeitos da radiação , Fóvea Central/efeitos da radiação , Modelos Biológicos , Estimulação Luminosa
11.
J Opt Soc Am A Opt Image Sci Vis ; 36(4): B97-B102, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31044967

RESUMO

Starbursts seen around small bright lights at night have been attributed to optical scatter, diffraction, or aberrations. We manipulated pupil aperture and aberrations to investigate the entopic appearance of perceived starbursts. The impact of circular, annular, and wedge-shaped pupil apertures, and spherical aberration sign and magnitude were used to identify pupil sub-apertures responsible for each radial perceived starburst line. Local intensity distributions within the starbursts mapped onto unique sub-regions of the pupil of both phakic and pseudophakic eyes, consistent with the hypothesis that ocular aberrations are the cause of starbursts. In paraxially focused eyes, the size of starbursts is predicted by the amount of spherical aberration, and starburst orientation is either the same or 180 deg rotated from the pupil region that creates each starburst line. No starbursts are seen when the pupil diameter is smaller than 3 mm. Replacing the eye's natural lens with a radially symmetric and optically homogeneous intraocular lens reduced the observed number of starbursts by 50%. Geometrical optics modeling including the measured aberrations of an individual eye can reveal point spread function structure that captures some of the key elements of the entopic perceptions.


Assuntos
Fenômenos Ópticos , Pupila/fisiologia , Humanos , Psicofísica
12.
Optom Vis Sci ; 96(10): 733-744, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31592956

RESUMO

SIGNIFICANCE: Measurement of ocular aberrations is a critical component of many optical corrections. PURPOSE: This study examines the accuracy and repeatability of a newly available high-resolution pyramidal wavefront sensor-based aberrometer (Osiris by Costruzione Strumenti Oftalmici, Firenze, Italy). METHODS: An engineered model eye and a dilated presbyopic eye were used to assess accuracy and repeatability of aberration measurements after systematic introduction of lower- and higher-order aberrations with calibrated trial lenses (sphere +10.00 to -10.00 D, and astigmatic -4.00 and -2.00 D with axis 180, 90, and 45°) and phase plates (-0.57 to 0.60 µm of Seidel spherical aberration defined over a 6-mm pupil diameter). Osiris aberration measurements were compared with those acquired on a previously calibrated COAS-HD aberrometer for foveal and peripheral optics both with and without multizone dual-focus contact lenses. The impact of simulated axial and lateral misalignment was evaluated. RESULTS: Root-mean-square errors for paraxial sphere (corneal plane), cylinder, and axis were, respectively, 0.07, 0.11 D, and 1.8° for the engineered model and 0.15, 0.26 D, and 2.7° for the presbyopic eye. Repeatability estimates (i.e., standard deviation of 10 repeat measures) for the model and presbyopic eyes were 0.026 and 0.039 D for spherical error. Root-mean-square errors of 0.01 and 0.02 µm, respectively, were observed for primary spherical aberration and horizontal coma (model eye). Foveal and peripheral measures of higher- and lower-order aberrations measured with the Osiris closely matched parallel data collected with the COAS-HD aberrometer both with and without dual-focus zonal bifocal contact lenses. Operator errors of focus and alignment introduced changes of 0.018 and 0.02 D/mm in sphere estimates. CONCLUSIONS: The newly available clinical pyramidal aberrometer provided accurate and repeatable measures of lower- and higher-order aberrations, even in the challenging but clinically important cases of peripheral retina and multifocal optics.


Assuntos
Aberrometria/instrumentação , Aberrações de Frente de Onda da Córnea/diagnóstico , Erros de Refração/diagnóstico , Acomodação Ocular/fisiologia , Adulto , Aberrações de Frente de Onda da Córnea/fisiopatologia , Humanos , Hiperopia/diagnóstico , Hiperopia/fisiopatologia , Pessoa de Meia-Idade , Miopia/diagnóstico , Miopia/fisiopatologia , Presbiopia/diagnóstico , Presbiopia/fisiopatologia , Refração Ocular/fisiologia , Erros de Refração/fisiopatologia , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia , Adulto Jovem
13.
Optom Vis Sci ; 96(4): 291-300, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30907860

RESUMO

SIGNIFICANCE: Approximately 10% of the lowercase text on nonprescription drug labels is smaller than the 1 mm required by the Food and Drug Administration. The small size, combined with the progressive decline in accommodative amplitude and gain, poses a reading challenge for middle-aged emerging presbyopes. PURPOSE: The purpose of this study was to evaluate the impact of progressing presbyopia and near adds on the ability of middle-aged patients to read small text routinely encountered on product labels. METHODS: Geometrical optics was used to determine the impact of changing viewing distance, accommodation, and pupil size on retinal blur size. We photographed 261 consumer product labels in grocery, personal care, and nonprescription (over-the-counter) drug categories and used character recognition software to identify and size 255,298 printed letters. We computed the impact of viewing distance on the ratio of blur to letter detail and used published blur ratios of ≤4 and ≤2 to identify the conditions that allowed for letter recognition and proficient reading, respectively. RESULTS: Median/mode lowercase letter heights (in millimeters) were 1.39/1.16, 1.29/1.15, and 1.18/1.01, respectively, for groceries, personal care, and over-the-counter drug categories. Despite the increased angular subtense of approaching letters, blur ratios generally increased with reduced viewing distance because of increased defocus. Increased viewing distance decreased blur, but small (e.g., 1 mm) letters became too small to read proficiently (angular size <10 arcminutes) for distances beyond 37 cm. With larger pupils, blur ratios were too large to support proficient reading when accommodative amplitude dropped to ≤3 diopters. An add power sufficient to bring the far point closer than 37 cm was required to proficiently read small text. CONCLUSIONS: Product labels, especially nonprescription drug packages, typically use fonts that are too small to be read proficiently by unaided emmetropes with emerging presbyopia. This problem can be ameliorated by correction of presbyopia at an earlier age and with higher add powers.


Assuntos
Acomodação Ocular/fisiologia , Rotulagem de Medicamentos , Meios de Comunicação de Massa , Presbiopia/fisiopatologia , Leitura , Transtornos da Visão/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pupila/fisiologia , Acuidade Visual/fisiologia
14.
J Opt Soc Am A Opt Image Sci Vis ; 35(5): 813-816, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29726494

RESUMO

Trolands are a widely used measure of retinal illuminance in vision science and visual optics, but disagreements exist for the definition and interpretation of this photometric unit. The purpose of this communication is to resolve the confusion by providing a sound conceptual basis for interpreting trolands as a measure of angular flux density incident upon the retina. Using a simplified optical analysis, we show that the troland value of an extended source is the intensity in micro-candelas of an equivalent point source located at the eye's posterior nodal point that produces the same illuminance in the retinal image as does the extended source. This optical interpretation of trolands reveals that total light flux in the image of an extended object is the product of the troland value of the source and the solid angle subtended by the source at the first nodal point, independent of eye size.


Assuntos
Fenômenos Fisiológicos Oculares , Estimulação Luminosa , Pupila/fisiologia , Retina/fisiologia , Humanos , Retina/efeitos da radiação
15.
Appl Opt ; 57(1): 62-68, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29328119

RESUMO

We report the development of an innovative standoff ultracompact micro-Raman instrument that would solve some of the limitations of traditional micro-Raman systems to provide a superior instrument for future NASA missions. This active remote sensor system, based on a 532 nm laser and a miniature spectrometer, is capable of inspection and identification of minerals, organics, and biogenic materials within several centimeters (2-20 cm) at a high 10 µm resolution. The sensor system is based on inelastic (Raman) light scattering and laser-induced fluorescence. We report on micro-Raman spectroscopy development and demonstration of the standoff Raman measurements by acquiring Raman spectra in daylight at a 10 cm target distance with a small line-shaped laser spot size of 17.3 µm (width) by 5 mm (height).

16.
Optom Vis Sci ; 95(1): 43-52, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29252900

RESUMO

SIGNIFICANCE: When fit with monovision, most early presbyopes (aged 40 to 50 years) accommodated to near objects by focusing the distance corrected eye, leaving the near corrected eye myopically defocused with reduced image quality. A few were able to switch focus to the near corrected eye retaining a consistently focused image in one eye over a wider range of distances. PURPOSE: The aim of this study was to examine accommodation behavior, pupil responses, and resultant image quality of early presbyopes fit with either bilateral or unilateral (monovision) near adds. METHODS: Accommodative response and pupil size of 19 subjects (27 to 60 years), including 13 early presbyopes (40 to 50 years), were measured using an aberrometer as a binocularly viewed 20/40 letter E was moved from 2 m to 20 cm. Each subject was fit with different refractive strategies: bilateral distance correction, bilateral +2 diopters (D) near add, and unilateral +2 D near add placed over the measured right eye or unmeasured left eye. Monochromatic image quality was quantified using the Visual Strehl ratio metric. RESULTS: With bilateral +2 D near add, all early presbyopes mostly refrained from accommodating (gain = 0.22 D/D) until the target approached closer than the 50-cm far point, and they then accommodated accurately until their maximum accommodative amplitude was reached. With monovision, most (10 of 13 early presbyopes) accommodated to focus the distance corrected eye, leaving the near corrected eye myopically defocused with reduced image quality. As stimulus distance became closer than their distance corrected eye's near point, they continued to exert maximum accommodation. Only two early presbyopes relaxed their accommodation to "switch" focus to the near corrected eye as target distance was reduced, and these two did not experience bilateral drop in image quality as stimulus distance became closer than the near point of the distance corrected eye. CONCLUSIONS: Our data suggest that many early presbyopes will not initially adopt an accommodation strategy that optimizes image quality with monovision, but consistently accommodate to focus the distance corrected eye.


Assuntos
Acomodação Ocular/fisiologia , Óculos , Presbiopia/fisiopatologia , Presbiopia/terapia , Aberrometria , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pupila/fisiologia , Refração Ocular/fisiologia , Testes Visuais , Visão Binocular/fisiologia , Acuidade Visual/fisiologia
17.
Optom Vis Sci ; 95(5): 416-427, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29683985

RESUMO

SIGNIFICANCE: The effectiveness of multifocal contact lenses (MFCLs) at slowing myopia progression may hinge on the accommodative behavior of young eyes fit with these presbyopic style lenses. Can they remove hyperopic defocus? Convergence accommodation as well as pupil size and the zonal geometry are likely to contribute to the final accommodative responses. PURPOSE: The aim of this study was to examine the accommodation behavior of young adult eyes wearing MFCLs and the effectiveness of these MFCLs at removing foveal hyperopic defocus when viewing near targets binocularly. METHODS: Using a high-resolution Shack-Hartmann aberrometer, accommodation and pupil behavior of eight young adults (27.25 ± 2.05 years) were measured while subjects fixated a 20/40 character positioned between 2 m and 20 cm (0.50 to 5.00 diopters [D]) in 0.25-D steps. Refractive states were measured while viewing binocularly and monocularly with single-vision and both center-distance and center-near +2.00 D add MFCLs. Refractive state was defined using three criteria: the dioptric power that would (1) minimize the root mean square wavefront error, (2) focus the pupil center, and (3) provide the peak image quality. RESULTS: Refractive state pupil maps reveal the complex optics that exist in eyes wearing MFCLs. Reduced accommodative gain beyond the far point of the near add revealed that young subjects used the added plus power to help focus near targets. During accommodation to stimuli closer than the far point generated by the add power, a midperipheral region of the pupil was approximately focused, resulting in the smallest accommodative errors for the minimum root mean square-defined measures of refractive state. Paraxial images were always hyperopically or myopically defocused in eyes viewing binocularly with center-distance or center-near MFCLs, respectively. Because of zone geometry in the concentric MFCLs tested, the highly aberrated transition zone between the distance and near optics contributed a significant proportion and sometimes the majority of light to the resulting images. CONCLUSIONS: Young eyes fit with MFCLs containing significant transition zones accommodated to focus pupil regions between the near and distance optics, which resulted in less than optimal retinal image quality and myopic or hyperopic defocus in either the pupil center or pupil margins.


Assuntos
Acomodação Ocular/fisiologia , Lentes de Contato , Miopia/terapia , Adulto , Feminino , Humanos , Hiperopia/fisiopatologia , Masculino , Miopia/fisiopatologia , Refração Ocular/fisiologia , Testes Visuais , Visão Binocular/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
18.
Ophthalmic Physiol Opt ; 38(2): 152-163, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29315718

RESUMO

PURPOSE: Multifocal or multi-zone contact lenses are increasingly being fit to young eyes in an attempt to control myopia progression. However, success in achieving this aim may depend on how much the eye accommodates. The purpose of the current work was to evaluate the ability of an open-field clinical autorefractor to measure on-axis refractive state and accommodation in eyes fit with multifocal contact lenses (CLs). METHODS: Refractive state was measured with a Grand Seiko WAM-5500 autorefractor (www.grandseiko.com) and a clinical Shack-Hartmann Complete Ophthalmic Analysis System (COAS) aberrometer (www.wfsci.com) in subjects fit bilaterally with single vision aspheric contact lenses, centre distance, and centre near zonal multifocal CLs, and an experimental myopia control multi-zone bifocal CLs (MiSight). Autorefractor measurements were obtained when aligned with the pupil centre, pupil margin, and mid-periphery. Accuracy of refractive state measurements was evaluated using a fully presbyopic (62-year-old) dilated (pupil diameter = 7.1 mm) eye measured through known added spherical powers (trial lenses) of +1.00 D to +6.00 D. Refractive state and accommodation were measured for seven young myopic eyes (23.71 ± 2.87 years) with six target vergences ranging from -0.33 D to -5.00 D. RESULTS: Irrespective of the CL fitted, measured changes in refractive state of the calibration eye were within ≤0.25 D of the added sphere power and the slope (measured refractive state/trial lens power) was approximately -1.0 D/D for both Shack-Hartmann (COAS) aberrometer and Grand Seiko instruments. Also, the Grand Seiko data were highly repeatable (mean measurement standard deviation = 0.04 D) as long as measurements occurred at the same pupil location, but exhibited a hyperopic bias that increased to +1.00 D when eyes were fit with CLs containing significant negative spherical aberration. Centre and marginal refractive states could differ by >3.00 D due to the combined spherical aberration contained in the eye plus the different CL designs. Measured refractive states of young accommodating eyes also varied with measurement location in the pupil. The accommodation gains were similar at each pupil location, irrespective of contact lens design. CONCLUSIONS: With consistent sampling at the same pupil location, the open field Grand Seiko clinical autorefractor proved an effective tool for assessing the on-axis refractive state and accommodative responses of eyes fit with multi-zone bifocal and multifocal CLs.


Assuntos
Acomodação Ocular/fisiologia , Lentes de Contato , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Testes Visuais/instrumentação , Acuidade Visual , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Erros de Refração/fisiopatologia , Adulto Jovem
19.
Ophthalmic Physiol Opt ; 38(1): 26-36, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29265469

RESUMO

PURPOSE: To test the hypothesis that marginal ray deviations determine perceived starburst sizes, and to explore different strategies for decreasing starburst size in highly aberrated eyes. METHODS: Perceived size of starburst images and visual acuities were measured psychophysically for eyes with varying levels of spherical aberration, pupil sizes, and defocus. Computationally, we use a polychromatic eye model including the typical levels of higher order aberrations (HOAs) for keratoconic and post-LASIK eyes to quantify the image quality (the visually weighted Strehl ratio derived from the optical transfer function, VSOTF) with different pupil sizes at both photopic and mesopic light levels. RESULTS: For distance corrected post-LASIK and keratoconic eyes with a night-time pupil (e.g., 7 mm), the starburst diameter is about 1.5 degrees (1 degree for normal presbyopic eyes), which can be reduced to ≤0.25 degrees with pupil sizes ≤3 mm. Starburst size is predicted from the magnitude of the longitudinal spherical aberration. Refracting the eye to focus the pupil margin also removed starbursts, but, unlike small pupils, significantly degraded visual acuity. Reducing pupil diameter to 3 mm improved image quality for these highly aberrated eyes by about 2.7 ×  to 1.7 ×  relative to the natural pupils when light levels were varied from 0.1 to 1000 cd m-2 , respectively. CONCLUSION: Subjects with highly aberrated eyes observed larger starbursts around bright lights at night predictable by the deviated marginal rays. These were effectively attenuated by reducing pupil diameters to ≤3 mm, which did not cause a drop in visual acuity or modelled image quality even at mesopic light levels.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miose/fisiopatologia , Pupila/efeitos da radiação , Acuidade Visual , Sensibilidades de Contraste , Feminino , Humanos , Luz , Masculino , Pessoa de Meia-Idade
20.
Ophthalmic Physiol Opt ; 38(1): 76-87, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29265475

RESUMO

PURPOSE: This study evaluated the feasibility of using soft contact lenses (CLs) with an opaque centre to induce absolute central scotomas that move with the eye. We examined the geometrical optics prediction that scotoma size will vary with the size of the CL's opaque centre and with ocular pupil size. We also tested the hypothesis that high environmental light levels will ensure that the ocular pupil will remain small enough, even with opaque centre CLs, to generate absolute scotomas representative of those experienced by patients with age-related macular disease. METHODS: Using an Octopus 900 Perimeter ( www.Haag-Streit.com), kinetic visual fields (VFs) were measured in five normally-sighted subjects using a V4e Goldmann target with CLs that had central opaque areas with diameters of 2.8, 3.0, and 3.2 mm. To control pupil size, VFs were measured with background perimeter bowl luminances of 10, 585, and 1155 cd m-2 . Subjects attempted to (i) fixate the bowl centre; and (ii) place the scotoma edge at the bowl fixation target (eccentric viewing). RESULTS: As predicted, there was a direct relationship between scotoma size and both luminance level and diameter of the opacity. Mean scotoma diameters were 0°, 17.6° and 22°, for the low, medium and high bowl luminances, respectively. Scotoma size was determined primarily by the difference between the diameters of CL opacity and the entrance pupil of the eye and the axial separation between them, and between-subject differences in pupil diameters contributed most to the between-subject variability in scotoma diameter at each light level (SD: 6.01°). Scotoma displacement during eccentric fixation confirmed the gaze-contingent characteristics of this experimental model. CONCLUSION: It is possible to induce a gaze-contingent absolute scotoma and hence mimic central vision loss using centrally-opaque CLs provided that the CL opacity is larger than the entrance pupil of the eye. This simulation tool will, therefore, be ineffective at low environmental light levels (as shown previously) if the entrance pupil of the eye is larger than the CL opacity.


Assuntos
Simulação por Computador , Lentes de Contato Hidrofílicas , Escotoma/diagnóstico , Acuidade Visual , Campos Visuais/fisiologia , Humanos , Escotoma/fisiopatologia , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA