Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Sleep Res ; 31(6): e13673, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35734809

RESUMO

Mandibular advancement device (MAD) treatment outcome for obstructive sleep apnea (OSA) is variable and patient dependent. A global, clinically applicable predictive model is lacking. Our aim was to combine characteristics obtained during drug-induced sleep endoscopy (DISE), awake nasendoscopy, and computed tomography scan-based computational fluid dynamic (CFD) measurements in one multifactorial model, to explain MAD treatment outcome. A total of 100 patients with OSA were prospectively recruited and treated with a MAD at fixed 75% protrusion. In all, 72 underwent CFD analysis, DISE, and awake nasendoscopy at baseline in a blinded fashion and completed a 3-month follow-up polysomnography with a MAD. Treatment response was defined as a reduction in the apnea-hypopnea index (AHI) of ≥50% and deterioration as an increase of ≥10% during MAD treatment. To cope with missing data, multiple imputation with predictive mean matching was used. Multivariate logistic regression, adjusting for body mass index and baseline AHI, was used to combine all potential predictor variables. The strongest impact concerning odds ratios (ORs) was present for complete concentric palatal collapse (CCCp) during DISE on deterioration (OR 28.88, 95% confidence interval [CI] 1.18-704.35; p = 0.0391), followed by a C-shape versus an oval shape of the soft palate during wakefulness (OR 8.54, 95% CI 1.09-67.23; p = 0.0416) and tongue base collapse during DISE on response (OR 3.29, 95% CI 1.02-10.64; p = 0.0464). Both logistic regression models exhibited excellent and fair predictive accuracy. Our findings suggest DISE to be the most robust examination associated with MAD treatment outcome, with tongue base collapse as a predictor for successful MAD treatment and CCCp as an adverse DISE phenotype.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Placas Oclusais , Vigília , Estudos Prospectivos , Hidrodinâmica , Carbonil Cianeto m-Clorofenil Hidrazona , Endoscopia/métodos , Resultado do Tratamento , Fenótipo , Sono
2.
Sleep Breath ; 26(4): 1837-1845, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35064876

RESUMO

STUDY OBJECTIVES: The aim of this pilot study was to evaluate the clinical effectiveness of subjective titration versus objectively guided titration during polysomnography (PSG) and drug-induced sleep endoscopy (DISE) in mandibular advancement device (MAD) therapy for patients with obstructive sleep apnea (OSA). METHODS: In this pilot cross-over study, patients underwent three titration procedures in randomized order: (1) subjective titration, (2) PSG-guided titration using a remotely controlled mandibular positioner (RCMP) and (3) DISE-assisted titration using RCMP. After each titration procedure, patients used the MAD for 1 month at the targeted protrusion obtained according to the preceding titration procedure. For each procedure, a follow-up PSG was performed after 1 month of MAD use in order to evaluate the efficacy of the MAD. RESULTS: Ten patients were included in the study. Overall, no significant differences in targeted optimal protrusion compared to maximal comfortable protrusion among the three titration methods were observed. There was no significant difference in reduction in AHI. In this study, PSG titration correctly classified 50% of patients as 'responder'. A higher predictive accuracy was found for DISE titration with a sensitivity of 83.3% and a specificity of 100%. CONCLUSIONS: This pilot randomized cross-over trial showed no differences in optimal mandibular positioning and corresponding efficacy of MAD between subjective titration, DISE titration or PSG titration.


Assuntos
Avanço Mandibular , Humanos , Polissonografia , Placas Oclusais , Projetos Piloto , Estudos Cross-Over , Endoscopia/métodos , Resultado do Tratamento , Sono
3.
Clin Otolaryngol ; 46(1): 234-242, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33002312

RESUMO

OBJECTIVES: Awake nasopharyngoscopy is routinely performed in the assessment of patients who require treatment for sleep-disordered breathing (SDB). However, the applicability and accuracy of Müller's manoeuvre, the main evaluation method for this purpose, are disputable. The current study aimed to introduce an alternative method for awake nasopharyngoscopy in patients with SDB. DESIGN: We defined qualitative anatomical features during tidal breathing at the levels of the soft palate, oropharynx, tongue base, epiglottis and hypopharynx, and compared these awake features to the sites and patterns of collapse as observed during drug-induced sleep endoscopy (DISE). SETTING: Tertiary care academic centre. PARTICIPANTS: Seventy-three patients diagnosed with SDB. MAIN OUTCOME MEASURES: The primary outcome measure was the Kendall's tau correlation coefficient (τ) between observations during awake nasopharyngoscopy and DISE. Kappa-statistics (κ) were calculated to assess the agreement on awake endoscopic features with a second observer. RESULTS: In contrast to epiglottis shape, the modified Cormack-Lehane scale was significantly associated with epiglottis collapse during DISE (P < .0001; τ = .45). Other upper airway features that were correlated with DISE collapse were the position of the soft palate (P = .007; τ = .29), crowding of the oropharynx (P = .026; τ = .32) and a posteriorly located tongue base (P = .046; τ = .32). Interobserver agreement of endoscopic features during tidal breathing was moderate (0.60 ≤ κ < 0.80). CONCLUSION: The current study introduces a comprehensive and reliable assessment method for awake nasopharyngoscopy based on anatomical features that are compatible with DISE collapse patterns.


Assuntos
Endoscopia , Sistema Respiratório/fisiopatologia , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Feminino , Humanos , Hipnóticos e Sedativos/uso terapêutico , Masculino , Midazolam/uso terapêutico , Pessoa de Meia-Idade , Propofol/uso terapêutico , Sono , Volume de Ventilação Pulmonar/fisiologia , Vigília
5.
Sleep Breath ; 19(2): 637-44, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25335642

RESUMO

PURPOSE: The objective of this randomized controlled trial was to assess the additional effect of a chest-worn sleep position trainer (SPT) in patients with residual supine-dependent obstructive sleep apnea (sdOSA) under mandibular advancement device (MAD) therapy. METHODS: Baseline and follow-up polysomnography with MAD were performed. Twenty patients with sdOSA under MAD therapy underwent two consecutive randomized polysomnographies: one with SPT and one with combination of SPT + MAD. Data are presented as median (quartile 1, quartile 3). RESULTS: The SPT reduced the time spent in supine sleeping position compared to baseline and MAD therapy. Both MAD and SPT were individually effective in reducing the overall apnea/hypopnea index (AHI) significantly when compared to baseline from 20.8 (15.1; 33.6)/h at baseline to 11.0 (6.7; 13.8)/h and to 11.1 (3.5; 17.7)/h with MAD or SPT, respectively. The combination of SPT + MAD further reduced the overall AHI to 5.7 (3.6; 7.4), which was significantly lower than with MAD alone (p < 0.001) and SPT alone (p < 0.008), respectively. CONCLUSIONS: The results of this study indicate that combination of SPT + MAD leads to a higher therapeutic efficacy in patients with sdOSA under MAD therapy when compared to one of the treatment modalities alone.


Assuntos
Terapia Combinada , Avanço Mandibular/instrumentação , Placas Oclusais , Posicionamento do Paciente/instrumentação , Modalidades de Fisioterapia/instrumentação , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Decúbito Dorsal/fisiologia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia
6.
Sleep Breath ; 18(2): 313-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23963782

RESUMO

PURPOSE: In order for a mandibular advancement device (MAD) to be efficacious, it must remain seated on the teeth during sleep. Quantitative data on the retentive characteristics of MADs are currently unavailable. The present pilot study is the first to describe an in vitro setup testing the retentive characteristics of different monobloc MADs. METHODS: A hydraulic cyclic test machine was used with MADs seated on dental casts to measure retention forces upon removal of the MADs. A custom-made monobloc (CM-mono), a thermoplastic monobloc (TP-mono), and a thermoplastic duobloc (TP-duo) configured as a monobloc were tested. Two protrusions were investigated, representing 25 and 65% of the maximal protrusion. The effects of the type of MAD, duration of the test, and amount of protrusion on removal forces were measured. RESULTS: The measured removal forces of all three MADs tested differed significantly, with the TP-duo showing the highest values (P < 0.0001). The effects of wear due to the repetitive cyclic loading became obvious by the production of wear particles in all MADs tested. However, only the TP-duo showed a significant reduction in time in removal forces for both protrusion positions (P < 0.0001; P = 0.0011). The effect of the amount of protrusion on the removal forces differed significantly between all three MADs tested (P = 0.0074). CONCLUSIONS: This in vitro pilot study reveals significant differences in retention forces for the MADs tested. The findings are consistent with clinical effects of nightly loss of MADs as reported in the literature and are within the range of reported physiological mouth-opening forces. Future research is needed to determine the key design features of MADs that explain these differences.


Assuntos
Retenção em Prótese Dentária , Avanço Mandibular/instrumentação , Aparelhos Ortodônticos , Apneia Obstrutiva do Sono/terapia , Remoção de Dispositivo , Humanos , Técnicas In Vitro , Desenho de Aparelho Ortodôntico , Projetos Piloto , Desenho de Prótese , Apneia Obstrutiva do Sono/diagnóstico
7.
Sleep Med ; 117: 95-98, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38518588

RESUMO

INTRODUCTION: Custom-made titratable mandibular advancement device (MAD) treatment can nowadays be considered a promising first-line treatment in patients with mild to severe obstructive sleep apnea (OSA). Specific manufacturing designs and titration mechanisms of MAD are on the market, characterized by their titration approach, vertical opening, and materials selection. The wing-designed MAD (SomnoDent® Flex™, SomnoMed Ltd, Sydney, Australia) has a lateral screw mechanism to advance the lower jaw in incremental steps of 0.1 up to 6.0 mm. The newer uniquely designed custom-made MAD with passive mouth closing (SomnoDent® Avant™ SomnoMed Ltd, Sydney, Australia) has a frontal exchangeable advancement strap of fixed lengths as a specific titration mechanism, all supporting freedom of lateral movement. We aimed to assess the associations between the type of MAD prescribed and OSA treatment outcome. METHODS: Data from 209 patients (165 male, mean age 53.9 (±10.9) years, median baseline BMI and AHI 27.02 [24.8; 29.7] kg/m2 and 22.8 [17.7; 31.6]/hour sleep, respectively) were collected. Of this cohort, 91 patients with the traditional, wing-based SomnoDent® Flex™ and 118 patients with SomnoDent® Avant™. All patients were diagnosed with a type 1 polysomnography demonstrating moderate to severe OSA (15 ≤ AHI ≤65 per hour sleep). The selected MAD was fitted in the so-called maximal comfortable protrusion. After 3 months of subjective titration until resolution of subjective symptoms and/or achieving physical limits, a checkup with validated home sleep monitoring was conducted. Treatment success was defined as "AHI reduction ≥50% with MAD compared to baseline AHI and AHI with MAD <10 events per hour". RESULTS: These real-world data set showed that 67% of patients achieved treatment success, with a statistically significant reduction in AHI from 22.8 [17.7; 31.6] to 7.45 [3.4; 15.0]/h sleep. The SomnoDent® Avant™ achieved 75% treatment success versus 56% for the traditional, wing-based SomnoDent® Flex™ (P < 0.05). Overall, AHI reduction was 70% for SomnoDent® Avant™ (P < 0.05) vs. 63% for SomnoDent® Flex™ (P < 0.05). CONCLUSIONS: This study shows that choice of MAD design can impact the treatment outcome and could become an important consideration in selecting the type of MAD for personalized treatment for OSA patients. While the results of the traditional wing-based MAD design were comparable to the therapeutic outcome with other titratable, custom-made MADs, the MAD with the passive mouth closing feature showed significantly greater reduction in total AHI potentially due to encouraged nasal breathing, reduced mouth breathing and lesser vertical opening thereby decreasing the probability of tongue base collapse.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Masculino , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/terapia , Placas Oclusais , Resultado do Tratamento , Sono
8.
Thorax ; 68(1): 91-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22993169

RESUMO

BACKGROUND: Oral appliance (OA) therapy is increasingly prescribed as a non-continuous positive airway pressure treatment modality for sleep-disordered breathing (SDB). Although OA therapy is reported to be efficacious for the treatment of SDB, data on compliance remain limited to self-report. METHODS: In this 3-month prospective clinical trial, the main outcome was to assess the safety and feasibility of an objective measurement of compliance during OA therapy using an embedded microsensor thermometer with on-chip integrated readout electronics in 51 consecutive patients with an established diagnosis of SDB (AHI 18.0 ± 11.9/h; age 47 ± 10 y; BMI 26.6 ± 4.0 kg/m(2); men/women: 31/20). Patients were unaware of the purpose of the study. RESULTS: No microsensor-related adverse events were recorded. In addition, no problems were encountered during the readout of the compliance data. Out of 51 microsensors, one had a technical defect and was lost to follow-up. In this study, the overall objective mean rate of OA use was 6.6 ± 1.3 h per day with a regular OA users' rate of 82% at the 3-month follow-up. Statistical analysis revealed no significant differences between objective and self-reported OA compliance data in this study. Measurement of the objective OA compliance allowed us to calculate the mean disease alleviation (MDA) as the product of objective compliance and therapeutic efficacy. MDA serves as a measure of the overall therapeutic effectiveness, and turned out to be 51.1%. CONCLUSIONS: The results illustrate the safety and feasibility of objective measurement of OA compliance. The objective measurement of OA compliance allows for calculation of the MDA.


Assuntos
Sistemas Microeletromecânicos , Aparelhos Ortodônticos , Cooperação do Paciente/estatística & dados numéricos , Síndromes da Apneia do Sono/terapia , Adulto , Pressão Positiva Contínua nas Vias Aéreas/métodos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Polissonografia/métodos , Estudos Prospectivos , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/diagnóstico , Termômetros
9.
J Sleep Res ; 22(3): 348-55, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23205856

RESUMO

The aim of this study was to assess the value of drug-induced sleep endoscopy (DISE) using a custom-made simulation bite in maximal comfortable protrusion (MCP) of the mandible, in the prediction of treatment outcome for obstructive sleep apnea (OSA) with a mandibular advancement device (MAD). Two hundred patients (74% male; age 46 ± 9 years; apnea-hypopnea index [AHI] 19 ± 13 h(-1) sleep; body mass index [BMI] 27 ± 4 kg m(-2) ) with sleep-disordered breathing underwent DISE with a simulation bite in MCP. One hundred and thirty-five patients with an established diagnosis of OSA commenced MAD treatment. The associations between the findings during DISE with simulation bite and treatment outcome were evaluated. Treatment response was defined as a reduction in AHI following MAD treatment of ≥ 50% compared to baseline. Overall MAD treatment response in the studied population was 69%. The results of this study demonstrated a statistically significant association between a positive effect of the simulation bite on the upper airway patency during DISE and treatment response with MAD (P < 0.01). The results of this study suggest that the use of a simulation bite in maximal comfortable protrusion (MCP) of the mandible, as used during DISE in patients with OSA, tends to be effective in predicting treatment response of MAD treatment.


Assuntos
Endoscopia/instrumentação , Avanço Mandibular/instrumentação , Apneia Obstrutiva do Sono/diagnóstico , Adulto , Endoscopia/métodos , Equipamentos e Provisões/normas , Feminino , Humanos , Masculino , Mandíbula/fisiopatologia , Pessoa de Meia-Idade , Polissonografia , Valor Preditivo dos Testes , Sono/fisiologia , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
10.
J Clin Sleep Med ; 19(12): 2035-2041, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37539639

RESUMO

STUDY OBJECTIVES: Treatment-emergent central sleep apnea (TECSA) describes the appearance or persistence of central sleep apnea while undergoing treatment for obstructive sleep apnea. TECSA is well studied in continuous positive airway pressure therapy with an estimated prevalence of 8%. Based on a few case reports, mandibular advancement devices (MAD) may also provoke TECSA. This study aims to gain insight into the prevalence of TECSA with MAD therapy. METHODS: This retrospective study includes a total of 129 patients with moderate to severe obstructive sleep apnea who were treated with a custom-made titratable MAD. Baseline and follow-up sleep studies were compared to identify patients with TECSA. Since different diagnostic criteria to define TECSA are used in literature, prevalence was calculated according to three definitions (TECSA-1, -2, and -3). Demographics, MAD treatment variables, and findings of the diagnostic polysomnography were compared between TECSA and non-TECSA patients to identify possible predictors. RESULTS: Depending on the definition used, TECSA was found in 3.1%-7.8% of patients undergoing MAD therapy. TECSA patients had a higher apnea index (9.2 vs 2.0 events/h, P = .042), central apnea-hypopnea index (4.1 vs 0.2 events/h, P = .045) and oxygen desaturation index (23.9 vs 16.3 events/h, P = .018) at baseline compared to non-TECSA patients. No differences were found in demographics and treatment variables. CONCLUSIONS: These findings demonstrate that TECSA also occurs in patients starting MAD treatment. Patients with TECSA had a higher apnea index, central apnea-hypopnea index, and oxygen desaturation index at baseline compared to non-TECSA patients. CITATION: Hellemans S, Van de Perck E, Braem MJ, Verbraecken J, Dieltjens M, Vanderveken OM. The prevalence of treatment-emergent central sleep apnea with mandibular advancement device therapy. J Clin Sleep Med. 2023;19(12):2035-2041.


Assuntos
Avanço Mandibular , Apneia do Sono Tipo Central , Apneia Obstrutiva do Sono , Humanos , Placas Oclusais , Apneia do Sono Tipo Central/epidemiologia , Apneia do Sono Tipo Central/terapia , Estudos Retrospectivos , Prevalência , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/terapia , Oxigênio , Resultado do Tratamento
11.
Laryngoscope ; 133(12): 3619-3627, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37366240

RESUMO

OBJECTIVE: To quantitatively investigate the effect of mandibular advancement devices (MADs) on pharyngeal airway dimensions in a transverse plane as measured during drug-induced sleep endoscopy (DISE). METHODS: Data from 56 patients, treated with MAD at 75% maximal protrusion and with baseline Apnea-Hypopnea Index ≥10 events/h, were analyzed. For each patient, three snapshots were selected from DISE video footage at baseline, with MAD presence, and during chin lift, resulting in 498 images (168/168/162, baseline/MAD/chin lift). Cross-sectional areas, anteroposterior (AP) and laterolateral (LL) dimensions on both retroglossal and retro-epiglottic levels were measured. To define the effect of MAD and chin lift on pharyngeal dimensions, linear mixed-effect models were built. Associations between MAD treatment response and pharyngeal expansion (MAD/chin lift) were determined. RESULTS: Significant differences were found between retroglossal cross-sectional areas, AP, and LL dimensions at baseline and with MAD presence. At a retro-epiglottic level, only LL dimensions differed significantly with MAD presence compared to baseline, with significant relation of LL expansion ratio to treatment response (p = 0.0176). After adjusting the response definition for the sleeping position, greater retroglossal expansion ratios were seen in responders (1.32 ± 0.48) compared to non-responders (1.11 ± 0.32) (p = 0.0441). No significant association was found between response and pharyngeal expansion by chin lift. CONCLUSION: Our observations highlight the additional value of quantitative pharyngeal airway measurements during DISE with MAD presence in evaluating MAD treatment outcome. These findings demonstrate an increase in retroglossal airway dimensions during DISE, with MAD presence, and more pronounced increase in retroglossal expansion ratios in MAD treatment responders compared to non-responders after sleeping position correction. LEVEL OF EVIDENCE: 3 Laryngoscope, 133:3619-3627, 2023.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/terapia , Polissonografia , Sono , Resultado do Tratamento , Endoscopia/métodos
12.
J Clin Sleep Med ; 18(3): 903-909, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34728052

RESUMO

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is associated with cardiovascular comorbidities such as left ventricular (LV) hypertrophy. Whether OSA is an independent etiological factor for this hypertrophic remodeling is yet unknown. Continuous positive airway pressure partially reverses this hypertrophy, but data regarding the effect of mandibular advancement devices on LV remodeling are scarce. The aim of this prospective trial is to evaluate the effect of mandibular advancement device therapy on LV geometry and function in patients with OSA. METHODS: At baseline and 6-month follow-up, participants underwent a home sleep apnea test, 24-hour ambulatory blood pressure monitoring and a 2-dimensional Doppler and tissue Doppler echocardiography. RESULTS: Sixty-three patients (age: 49 ± 11 years; body mass index: 27.0 ± 3.4 kg/m2; baseline apnea-hypopnea index home sleep apnea test: 11.7 [8.2; 24.9] events/h) completed the 6-month follow-up visit. Overall, blood pressure values and parameters of LV function were within normal ranges at baseline and did not change under mandibular advancement device therapy. In contrast, the interventricular septum thickness was at the upper limits of normal at baseline and showed a significant decrease at 6-month follow-up (11.1 ± 2.1 mm vs 10.6 ± 2.0 mm, P = .03). This significant improvement is only found in responders but not in nonresponders. There was no correlation between the decrease of interventricular septum thickness and the change in blood pressure. CONCLUSIONS: In mildly obese, normotensive patients with OSA we observed significant reverse hypertrophic remodeling after 6 months of successful mandibular advancement device therapy, with maintained normotensive systemic blood pressure. This suggests that OSA is an independent factor in the pathophysiology of LV hypertrophy in these patients. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Evaluation of the Cardiovascular Effects of the MAS in the Treatment of Obstructive Sleep Apnea; URL: https://clinicaltrials.gov/ct2/show/NCT02320877; Identifier: NCT02320877. CITATION: Dieltjens M, Vanderveken OM, Shivalkar B, et al. Mandibular advancement device treatment and reverse left ventricular hypertrophic remodeling in patients with obstructive sleep apnea. J Clin Sleep Med. 2022;18(3):903-909.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Adulto , Monitorização Ambulatorial da Pressão Arterial , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Hipertrofia , Avanço Mandibular/métodos , Pessoa de Meia-Idade , Placas Oclusais , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
13.
J Clin Sleep Med ; 18(3): 739-750, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34608859

RESUMO

STUDY OBJECTIVES: Mandibular advancement devices (MADs) are a noninvasive treatment option for patients with obstructive sleep apnea (OSA) and act by increasing the upper airway volume. However, the exact therapeutic mechanism of action remains unclear. The aim of this study was to assess MAD mechanisms using functional imaging that combines imaging techniques and computational fluid dynamics and assess associations with treatment outcome. METHODS: One hundred patients with OSA were prospectively included and treated with a custom-made MAD at a fixed 75% protrusion. A low-dose computed tomography scan was made with and without MADs for computational fluid dynamics analysis. Patients underwent a baseline and 3-month follow-up polysomnography to evaluate treatment efficacy. A reduction in apnea-hypopnea index ≥ 50% defined treatment response. RESULTS: Overall, 71 patients completed both 3-month follow-up polysomnography and low-dose computed tomography scan with computational fluid dynamics analysis. MAD treatment significantly reduced the apnea-hypopnea index (16.5 [10.4-23.6] events/h to 9.1 [3.9-16.4] events/h; P < .001, median [quartile 1-quartile 3]) and significantly increased the total upper airway volume (8.6 [5.4-12.8] cm3 vs 10.7 [6.4-15.4] cm3; P = .003), especially the velopharyngeal volume (2.1 [0.5-4.1] cm3 vs 3.3 [1.8-6.0] cm3; P < .001). However, subanalyses in responders and nonresponders only showed a significant increase in the total upper airway volume in responders, not in nonresponders. CONCLUSIONS: MAD acts by increasing the total upper airway volume, predominantly due to an increase in the velopharyngeal volume. Responders showed a significant increase in the total upper airway volume with MAD treatment, while there was no significant increase in nonresponders. Findings add evidence to implement functional imaging using computational fluid dynamics in routine MAD outcome prediction. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Predicting Therapeutic Outcome of Mandibular Advancement Device Treatment in Obstructive Sleep Apnea; URL: https://clinicaltrials.gov/ct2/show/NCT01532050; Identifier: NCT01532050. CITATION: Van Gaver H, Op de Beeck S, Dieltjens M, et al. Functional imaging improves patient selection for mandibular advancement device treatment outcome in sleep-disordered breathing: a prospective study. J Clin Sleep Med. 2022;18(3):739-750.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Placas Oclusais , Seleção de Pacientes , Estudos Prospectivos , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
14.
Ann Am Thorac Soc ; 18(3): 511-518, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32946702

RESUMO

Rationale: Mandibular advancement device (MAD) treatment efficacy varies among patients with obstructive sleep apnea.Objectives: The current study aims to explain underlying individual differences in efficacy using obstructive sleep apnea endotypic traits calculated from baseline clinical polysomnography: collapsibility (airflow at normal ventilatory drive), loop gain (drive response to reduced airflow), arousal threshold (drive preceding arousal), compensation (increase in airflow as drive increases), and the ventilatory response to arousal (increase in drive explained by arousal). On the basis of previous research, we hypothesized that responders to MAD treatment have a lower loop gain and milder collapsibility.Methods: Thirty-six patients (median apnea-hypopnea index [AHI], 23.5 [interquartile range (IQR), 19.7-29.8] events/h) underwent baseline and 3-month follow-up full polysomnography, with MAD fixed at 75% of maximal protrusion. Traits were estimated using baseline polysomnography according to Sands and colleagues. Response was defined as an AHI reduction ≥ 50%.Results: MAD treatment significantly reduced AHI (49.7%baseline [23.9-63.6], median [IQR]). Responders exhibited lower loop gain (mean [95% confidence interval], 0.53 [0.48-0.58] vs. 0.65 [0.57-0.73]; P = 0.020) at baseline than nonresponders, a difference that persisted after adjustment for baseline AHI and body mass index. Elevated loop gain remained associated with nonresponse after adjustment for collapsibility (odds ratio, 3.03 [1.16-7.88] per 1-standard deviation (SD) increase in loop gain [SD, 0.15]; P = 0.023).Conclusions: MAD nonresponders exhibit greater ventilatory instability, expressed as higher loop gain. Assessment of the baseline degree of ventilatory instability using this approach may improve upfront MAD treatment patient selection.Clinical trial registered with www.clinicaltrials.gov (NCT01532050).


Assuntos
Placas Oclusais , Apneia Obstrutiva do Sono , Nível de Alerta , Humanos , Polissonografia , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
15.
J Clin Sleep Med ; 16(7): 1189-1198, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32267227

RESUMO

STUDY OBJECTIVES: The variable efficacy of mandibular advancement device (MAD) treatment necessitates both accessible and accurate methods for patient selection. However, the role of awake nasopharyngoscopy for this purpose remains dubious. We introduced an assessment method based on anatomical upper airway features during tidal breathing for nasopharyngoscopy. The current study aimed to relate these features to MAD treatment outcome. METHODS: One hundred patients diagnosed with obstructive sleep apnea were prospectively recruited for MAD treatment in a fixed 75% degree of maximal protrusion. Nasopharyngoscopic observations during Müller's maneuver and tidal breathing were recorded both with and without MAD. Treatment outcome, confirmed by 3-month follow-up polysomnography with MAD, was classified as (1) apnea-hypopnea index reduction ≥ 50%, (2) treatment apnea-hypopnea index < 5 events/h, and (3) ≥ 10% increase in apnea-hypopnea index compared with baseline (treatment deterioration). RESULTS: A complete dataset was obtained in 65 patients. After adjusting for baseline apnea-hypopnea index, body mass index, and supine dependency, the position of the soft palate (odds ratio, 4.0; 95% confidence interval, 1.3-11.8; P = .013) and crowding of the oropharynx (odds ratio, 7.7; 95% confidence interval, 1.4-41.4; P = .017) were related to treatment deterioration. Addition of both features significantly (P = .031) improved the accuracy of baseline models based on clinical measurements alone. Moreover, with the MAD in situ, a posteriorly located soft palate (odds ratio, 9.8; 95% confidence interval, 1.7-56.3; P = .010) and a posteriorly located tongue base (odds ratio, 7.4; 95% confidence interval, 1.5-35.9; P = .013) were associated with treatment deterioration. CONCLUSIONS: Awake nasopharyngoscopy might be a valuable office-based examination to exclude the risk of treatment deterioration and improve patient selection for MAD treatment. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Predicting Therapeutic Outcome of Mandibular Advancement Device Treatment in Obstructive Sleep Apnea (PROMAD); URL: https://clinicaltrials.gov/ct2/show/NCT01532050; Identifier: NCT01532050.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Faringe , Polissonografia , Estudos Prospectivos , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
16.
Laryngoscope ; 130(4): E268-E274, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31034634

RESUMO

OBJECTIVES/HYPOTHESIS: To evaluate upper airway (UA) collapse patterns during drug-induced sleep endoscopy (DISE) and maxillomandibular advancement (MMA) surgery outcome, paying particular attention to the DISE phenotype complete concentric collapse at the level of the palate (CCCp). STUDY DESIGN: Prospective case series. METHODS: Nineteen patients diagnosed with obstructive sleep apnea (OSA) prospectively underwent mandibular advancement device (MAD) treatment followed by MMA surgery. UA collapse patterns were evaluated before and after MMA surgery. Baseline apnea-hypopnea index (AHI) was compared with AHI during MAD treatment and after MMA surgery. UA collapse patterns and the presence of baseline CCCp were assessed. AHI differences between patients with and without CCCp after MMA surgery were compared. RESULTS: In 14 patients, a full dataset was obtained: 8/6 (male/female), mean age = 51 ± 7 years, body mass index (BMI) = 25.6 ± 3.7 kg/m2 , and baseline AHI = 40.2 ± 25.6 per hour of sleep. MMA surgery reduced AHI to 9.9 ± 7.2 per hour of sleep (P = .0001). Eight patients benefited from additional AHI reduction compared to MAD treatment (P = .0113). Six out of 14 (43%) patients showed baseline CCCp. Baseline patient characteristics (age, BMI, and AHI) did not significantly differ between patients with and without CCCp. AHI was equally reduced after MMA, whether (P = .0145) or not (P = .0075) CCCp was present at baseline. All patients showed resolution of CCCp (P = .0159) during postoperative DISE. CONCLUSIONS: CCCp seems not to be a negative predictor for MMA surgery outcome measured by AHI reduction. Furthermore, MMA is likely to eliminate CCCp. Therefore, MMA might be a solution for OSA patients showing CCCp and broadens the perspective for personalized medicine and combination therapy. However, a large sample is required for definitive results. LEVEL OF EVIDENCE: 4 Laryngoscope, 130:E268-E274, 2020.


Assuntos
Obstrução das Vias Respiratórias/cirurgia , Endoscopia/métodos , Avanço Mandibular , Apneia Obstrutiva do Sono/cirurgia , Obstrução das Vias Respiratórias/fisiopatologia , Feminino , Humanos , Hipnóticos e Sedativos/administração & dosagem , Masculino , Pessoa de Meia-Idade , Ortodontia Corretiva , Osteotomia de Le Fort , Osteotomia Sagital do Ramo Mandibular , Fenótipo , Polissonografia , Estudos Prospectivos , Sono , Apneia Obstrutiva do Sono/fisiopatologia
19.
Am J Respir Crit Care Med ; 178(2): 197-202, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17673699

RESUMO

RATIONALE: The efficacy of immediate adaptation of mandibular advancement devices made of thermoplastic material as a treatment option for sleep-disordered breathing (SDB) has been demonstrated in clinical studies. To date, there have been no studies comparing the efficacy of such prefabricated devices with custom-made devices. OBJECTIVES: Our purpose was to compare the efficacy of both types of devices in patients with SDB. METHODS: A randomized controlled cross-over trial, comprising 4 months of treatment with a thermoplastic and a custom-made device, with a 1-month washout interval. MEASUREMENTS AND MAIN RESULTS: A total of 35 patients (29 males; age, 49 +/- 9 yr; apnea-hypopnea index [AHI], 13 +/- 11 events/h; body mass index, 28 +/- 4 kg/m(2)) completed the protocol. AHI was only reduced with the custom-made device (P = 0.005). In addition, this device reduced snoring to a greater extent than the thermoplastic device. The success rate was higher with the custom-made device (60 vs. 31%; P = 0.02). One-third of the patients demonstrated compliance failure with the thermoplastic device, mainly because of insufficient overnight retention. Total failure rate with the thermoplastic device was 69%, whereas the majority (63%) of these were successfully treated with the custom-made device. At the end of the study, 82% of the patients preferred the custom-made device, and 9% had no preference (P < 0.0001). CONCLUSIONS: In this study, a custom-made device turned out to be more effective than a thermoplastic device in the treatment of SDB. Our results suggest that the thermoplastic device cannot be recommended as a therapeutic option nor can it be used as a screening tool to find good candidates for mandibular advancement therapy.


Assuntos
Avanço Mandibular/instrumentação , Aparelhos Ortodônticos Removíveis , Apneia Obstrutiva do Sono/terapia , Ronco/terapia , Análise de Variância , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia
20.
Eur Respir Rev ; 28(153)2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-31554705

RESUMO

Oral appliances are increasingly recommended for selected patients with obstructive sleep apnoea (OSA) and those who do not tolerate nor prefer continuous positive airway pressure. The most commonly used oral appliance advances the lower jaw during sleep, the so-called mandibular advancement device (MAD). Patients seek treatment because of disturbing snoring, daytime symptoms, apnoeas that disturb sleep and the longer term consequences with regard to cardiovascular risks. MADs reduce the apnoea-hypopnoea index, although to various degrees among patients. Effects on daytime sleepiness have been observed mainly among the more severe OSA patients. Blood pressure may be reduced in MAD-treated OSA patients. There is, however, uncertainty about which patients will respond to this therapy in terms of apnoea reductions, decreased sleepiness and other symptoms, and reduced risk for future impaired health. The occurrence of side-effects also remains difficult to predict at present. The majority of sleep apnoea patients suffer from various comorbidities in terms of cardiovascular diseases, type 2 diabetes and depression. The most recent findings indicate that phenotyping of patients, considering various aspects of this multifaceted disease, will shed more light on the indications for MADs in patients with nightly sleep breathing disturbances. This review summarises the most recent knowledge about MAD treatment.


Assuntos
Avanço Mandibular/instrumentação , Placas Oclusais , Apneia Obstrutiva do Sono/terapia , Comorbidade , Desenho de Equipamento , Humanos , Pulmão/fisiopatologia , Avanço Mandibular/efeitos adversos , Respiração , Fatores de Risco , Sono , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA