Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Sci Rep ; 14(1): 10400, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710823

RESUMO

Without the protective shielding of Earth's atmosphere, astronauts face higher doses of ionizing radiation in space, causing serious health concerns. Highly charged and high energy (HZE) particles are particularly effective in causing complex and difficult-to-repair DNA double-strand breaks compared to low linear energy transfer. Additionally, chronic cortisol exposure during spaceflight raises further concerns, although its specific impact on DNA damage and repair remains unknown. This study explorers the effect of different radiation qualities (photons, protons, carbon, and iron ions) on the DNA damage and repair of cortisol-conditioned primary human dermal fibroblasts. Besides, we introduce a new measure, the Foci-Integrated Damage Complexity Score (FIDCS), to assess DNA damage complexity by analyzing focus area and fluorescent intensity. Our results show that the FIDCS captured the DNA damage induced by different radiation qualities better than counting the number of foci, as traditionally done. Besides, using this measure, we were able to identify differences in DNA damage between cortisol-exposed cells and controls. This suggests that, besides measuring the total number of foci, considering the complexity of the DNA damage by means of the FIDCS can provide additional and, in our case, improved information when comparing different radiation qualities.


Assuntos
Quebras de DNA de Cadeia Dupla , Reparo do DNA , Fibroblastos , Hidrocortisona , Humanos , Fibroblastos/efeitos da radiação , Fibroblastos/metabolismo , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Hidrocortisona/farmacologia , Radiação Ionizante , Células Cultivadas , Dano ao DNA
2.
Phys Med ; 112: 102636, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37494764

RESUMO

PURPOSE: To assess the feasibility of a proton radiography (pRG) system based on a single thin pixelated detector for water-equivalent path length (WEPL) and relative stopping power (RSP) measurements. METHODS: A model of a pRG system consisting of a single pixelated detector measuring energy deposition and proton fluence was investigated in a Geant4-based Monte Carlo study. At the position directly after an object traversed by a broad proton beam, spatial 2D distributions are calculated of the energy deposition in, and the number of protons entering the detector. Their ratio relates to the 2D distribution of the average stopping power of protons in the detector. The system response is calibrated against the residual range in water of the protons to provide the 2D distribution of the WEPL of the object. The WEPL distribution is converted into the distribution of the RSP of the object. Simulations have been done, where the system has been tested on 13 samples of homogeneous materials of which the RSPs have been calculated and compared with RSPs determined from simulations of residual-range-in-water, which we refer to as reference RSPs. RESULTS: For both human-tissue- and non-human-tissue-equivalent materials, the RSPs derived with the detector agree with the reference values within 1%. CONCLUSION: The study shows that a pRG system based on one thin pixelated detection screen has the potential to provide RSP predictions with an accuracy of 1%.

3.
Med Phys ; 50(3): 1756-1765, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36629844

RESUMO

BACKGROUND: Proton radiography (PR) uses highly energetic proton beams to create images where energy loss is the main contrast mechanism. Water-equivalent path length (WEPL) measurements using flat panel PR (FP-PR) have potential for in vivo range verification. However, an accurate WEPL measurement via FP-PR requires irradiation with multiple energy layers, imposing high imaging doses. PURPOSE: A FP-PR method is proposed for accurate WEPL determination based on a patient-specific imaging field with a reduced number of energies (n) to minimize imaging dose. METHODS: Patient-specific FP-PRs were simulated and measured for a head and neck (HN) phantom. An energy selection algorithm estimated spot-wise the lowest energy required to cross the anatomy (Emin) using a water-equivalent thickness map. Starting from Emin, n was restricted to certain values (n = 26, 24, 22, …, 2 for simulations, n = 10 for measurements), resulting in patient-specific FP-PRs. A reference FP-PR with a complete set of energies was compared against patient-specific FP-PRs covering the whole anatomy via mean absolute WEPL differences (MAD), to evaluate the impact of the developed algorithm. WEPL accuracy of patient-specific FP-PRs was assessed using mean relative WEPL errors (MRE) with respect to measured multi-layer ionization chamber PRs (MLIC-PR) in the base of skull, brain, and neck regions. RESULTS: MADs ranged from 2.1 mm (n = 26) to 21.0 mm (n = 2) for simulated FP-PRs, and 7.2 mm for measured FP-PRs (n = 10). WEPL differences below 1 mm were observed across the whole anatomy, except at the phantom surfaces. Measured patient-specific FP-PRs showed good agreement against MLIC-PRs, with MREs of 1.3 ± 2.0%, -0.1 ± 1.0%, and -0.1 ± 0.4% in the three regions of the phantom. CONCLUSION: A method to obtain accurate WEPL measurements using FP-PR with a reduced number of energies selected for the individual patient anatomy was established in silico and validated experimentally. Patient-specific FP-PRs could provide means of in vivo range verification.


Assuntos
Terapia com Prótons , Prótons , Humanos , Água , Radiografia , Imagens de Fantasmas , Cabeça/diagnóstico por imagem
4.
Cells ; 12(2)2023 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-36672184

RESUMO

Human spaceflight is associated with several health-related issues as a result of long-term exposure to microgravity, ionizing radiation, and higher levels of psychological stress. Frequent reported skin problems in space include rashes, itches, and a delayed wound healing. Access to space is restricted by financial and logistical issues; as a consequence, experimental sample sizes are often small, which limits the generalization of the results. Earth-based simulation models can be used to investigate cellular responses as a result of exposure to certain spaceflight stressors. Here, we describe the development of an in vitro model of the simulated spaceflight environment, which we used to investigate the combined effect of simulated microgravity using the random positioning machine (RPM), ionizing radiation, and stress hormones on the wound-healing capacity of human dermal fibroblasts. Fibroblasts were exposed to cortisol, after which they were irradiated with different radiation qualities (including X-rays, protons, carbon ions, and iron ions) followed by exposure to simulated microgravity using a random positioning machine (RPM). Data related to the inflammatory, proliferation, and remodeling phase of wound healing has been collected. Results show that spaceflight stressors can interfere with the wound healing process at any phase. Moreover, several interactions between the different spaceflight stressors were found. This highlights the complexity that needs to be taken into account when studying the effect of spaceflight stressors on certain biological processes and for the aim of countermeasures development.


Assuntos
Ausência de Peso , Humanos , Ausência de Peso/efeitos adversos , Hidrocortisona/farmacologia , Simulação de Ausência de Peso , Radiação Ionizante , Cicatrização
5.
Sci Rep ; 12(1): 1822, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-35110676

RESUMO

For image-guided small animal irradiations, the whole workflow of imaging, organ contouring, irradiation planning, and delivery is typically performed in a single session requiring continuous administration of anaesthetic agents. Automating contouring leads to a faster workflow, which limits exposure to anaesthesia and thereby, reducing its impact on experimental results and on animal wellbeing. Here, we trained the 2D and 3D U-Net architectures of no-new-Net (nnU-Net) for autocontouring of the thorax in mouse micro-CT images. We trained the models only on native CTs and evaluated their performance using an independent testing dataset (i.e., native CTs not included in the training and validation). Unlike previous studies, we also tested the model performance on an external dataset (i.e., contrast-enhanced CTs) to see how well they predict on CTs completely different from what they were trained on. We also assessed the interobserver variability using the generalized conformity index ([Formula: see text]) among three observers, providing a stronger human baseline for evaluating automated contours than previous studies. Lastly, we showed the benefit on the contouring time compared to manual contouring. The results show that 3D models of nnU-Net achieve superior segmentation accuracy and are more robust to unseen data than 2D models. For all target organs, the mean surface distance (MSD) and the Hausdorff distance (95p HD) of the best performing model for this task (nnU-Net 3d_fullres) are within 0.16 mm and 0.60 mm, respectively. These values are below the minimum required contouring accuracy of 1 mm for small animal irradiations, and improve significantly upon state-of-the-art 2D U-Net-based AIMOS method. Moreover, the conformity indices of the 3d_fullres model also compare favourably to the interobserver variability for all target organs, whereas the 2D models perform poorly in this regard. Importantly, the 3d_fullres model offers 98% reduction in contouring time.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica , Tórax/diagnóstico por imagem , Microtomografia por Raio-X , Animais , Feminino , Camundongos Endogâmicos BALB C , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fluxo de Trabalho
6.
Phys Med Biol ; 67(14)2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35697024

RESUMO

Objective. Point detector measurements in proton fields are perturbed by the volume effect originating from geometrical volume-averaging within the extended detector's sensitive volume and density perturbations by non-water equivalent detector components. Detector specific lateral dose response functionsK(x) can be used to characterize the volume effect within the framework of a mathematical convolution model, whereK(x) is the convolution kernel transforming the true dose profileD(x) into the measured signal profile of a detectorM(x). The aim of this work is to investigateK(x) for detectors in proton beams.Approach. TheK(x) for five detectors were determined by iterative deconvolution of measurements ofD(x) andM(x) profiles at 2 cm water equivalent depth of a narrow 150 MeV proton beam. Monte Carlo simulations were carried out for two selected detectors to investigate a potential energy dependence, and to study the contribution of volume-averaging and density perturbation to the volume effect.Main results. The Monte Carlo simulated and experimentally determinedK(x) agree within 2.1% of the maximum value. Further simulations demonstrate that the main contribution to the volume effect is volume-averaging. The results indicate that an energy or depth dependence ofK(x) is almost negligible in proton beams. While the signal reduction from a Semiflex 3D ionization chamber in the center of a gaussian shaped field with 2 mm sigma is 32% for photons, it is 15% for protons. When measuring the field with a microDiamond the trend is less pronounced and reversed with a signal reduction for protons of 3.9% and photons of 1.9%.Significance. The determinedK(x) can be applied to characterize the influence of the volume effect on detectors measured signal profiles at all clinical proton energies and measurement depths. The functions can be used to derive the actual dose distribution from point detector measurements.


Assuntos
Prótons , Radiometria , Algoritmos , Método de Monte Carlo , Fótons , Radiometria/métodos
7.
Med Phys ; 38(1): 256-63, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21361194

RESUMO

PURPOSE: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed +/-1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. METHODS: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. RESULTS: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was +/-0.8% and +/-0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132 +/- 10 keV/microm and dose-averaged LET of 189 +/- 15 keV/microm at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. CONCLUSIONS: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.


Assuntos
Carbono/uso terapêutico , Células/efeitos da radiação , Radioterapia/métodos , Carbono/química , Sobrevivência Celular/efeitos da radiação , Células/patologia , Células HEK293 , Humanos , Transferência Linear de Energia , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
8.
Sci Rep ; 11(1): 14528, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34267233

RESUMO

Cellular responses to DNA double-strand breaks (DSBs) not only promote genomic integrity in healthy tissues, but also largely determine the efficacy of many DNA-damaging cancer treatments, including X-ray and particle therapies. A growing body of evidence suggests that activation of the mechanisms that detect, signal and repair DSBs may depend on the complexity of the initiating DNA lesions. Studies focusing on this, as well as on many other radiobiological questions, require reliable methods to induce DSBs of varying complexity, and to visualize the ensuing cellular responses. Accelerated particles of different energies and masses are exceptionally well suited for this task, due to the nature of their physical interactions with the intracellular environment, but visualizing cellular responses to particle-induced damage - especially in their early stages - at particle accelerator facilities, remains challenging. Here we describe a straightforward approach for real-time imaging of early response to particle-induced DNA damage. We rely on a transportable setup with an inverted fluorescence confocal microscope, tilted at a small angle relative to the particle beam, such that cells can be irradiated and imaged without any microscope or beamline modifications. Using this setup, we image and analyze the accumulation of fluorescently-tagged MDC1, RNF168 and 53BP1-key factors involved in DSB signalling-at DNA lesions induced by 254 MeV α-particles. Our results provide a demonstration of technical feasibility and reveal asynchronous initiation of accumulation of these proteins at different individual DSBs.


Assuntos
Dano ao DNA , Microscopia de Fluorescência/instrumentação , Aceleradores de Partículas , Epitélio Pigmentado da Retina/efeitos da radiação , Proteínas Adaptadoras de Transdução de Sinal/análise , Proteínas de Ciclo Celular/análise , Linhagem Celular , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Desenho de Equipamento , Humanos , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Imagem Molecular/instrumentação , Imagem Molecular/métodos , Estudo de Prova de Conceito , Epitélio Pigmentado da Retina/citologia , Proteína 1 de Ligação à Proteína Supressora de Tumor p53/análise , Ubiquitina-Proteína Ligases/análise
9.
Phys Med Biol ; 65(24): 245013, 2020 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-32650323

RESUMO

Compared to photon therapy, proton therapy allows a better conformation of the dose to the tumor volume with reduced radiation dose to co-irradiated tissues. In vivo verification techniques including positron emission tomography (PET) have been proposed as quality assurance tools to mitigate proton range uncertainties. Detection of differences between planned and actual dose delivery on a short timescale provides a fast trigger for corrective actions. Conventional PET-based imaging of 15O (T1/2 = 2 min) and 11C (T1/2 = 20 min) distributions precludes such immediate feedback. We here present a demonstration of near real-time range verification by means of PET imaging of 12N (T1/2 = 11 ms). PMMA and graphite targets were irradiated with a 150 MeV proton pencil beam consisting of a series of pulses of 10 ms beam-on and 90 ms beam-off. Two modules of a modified Siemens Biograph mCT PET scanner (21 × 21 cm2 each), installed 25 cm apart, were used to image the beam-induced PET activity during the beam-off periods. The modifications enable the detectors to be switched off during the beam-on periods. 12N images were reconstructed using planar tomography. Using a 1D projection of the 2D reconstructed 12N image, the activity range was obtained from a fit of the activity profile with a sigmoid function. Range shifts due to modified target configurations were assessed for multiples of the clinically relevant 108 protons per pulse (approximately equal to the highest intensity spots in the pencil beam scanning delivery of a dose of 1 Gy over a cubic 1 l volume). The standard deviation of the activity range, determined from 30 datasets obtained from three irradiations on PMMA and graphite targets, was found to be 2.5 and 2.6 mm (1σ) with 108 protons per pulse and 0.9 and 0.8 mm (1σ) with 109 protons per pulse. Analytical extrapolation of the results from this study shows that using a scanner with a solid angle coverage of 57%, with optimized detector switching and spot delivery times much smaller than the 12N half-life, an activity range measurement precision of 2.0 mm (1σ) and 1.3 mm (1σ) within 50 ms into an irradiation with 4 × 107 and 108 protons per pencil beam spot can be potentially realized. Aggregated imaging of neighboring spots or, if possible, increasing the number of protons for a few probe beam spots will enable the realization of higher precision range measurement.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Terapia com Prótons/métodos , Calibragem , Estudos de Viabilidade , Meia-Vida , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia
10.
Front Phys ; 8: 00380, 2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-33224942

RESUMO

Biomedical applications at high-energy particle accelerators have always been an important section of the applied nuclear physics research. Several new facilities are now under constructions or undergoing major upgrades. While the main goal of these facilities is often basic research in nuclear physics, they acknowledge the importance of including biomedical research programs and of interacting with other medical accelerator facilities providing patient treatments. To harmonize the programs, avoid duplications, and foster collaboration and synergism, the International Biophysics Collaboration is providing a platform to several accelerator centers with interest in biomedical research. In this paper, we summarize the programs of various facilities in the running, upgrade, or construction phase.

11.
Phys Med Biol ; 64(23): 235012, 2019 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-31658450

RESUMO

Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is limited by range uncertainties. This has led to efforts by several groups to develop in vivo verification techniques, including positron emission tomography (PET), for monitoring of the dose delivery. Beam-on PET monitoring during proton therapy through the detection of short-lived positron emitters such as 12N (T 1/2 = 11 ms), an emerging PET technique, provides an attractive option given the achievable range accuracy, minimal susceptibility to biological washout and provision of near prompt feedback. Extension of this approach to helium ions requires information on the production yield of relevant short-lived positron emitters. This study presents the first measurements of the production of short-lived positron emitters in water, graphite, calcium and phosphorus targets irradiated with 59 MeV/u 3He and 50 MeV/u 4He beams. For these targets, the most produced short-lived nuclides are 13O/12N (T 1/2 = 8.6/11 ms) on water, 13O/12N on graphite, 43Ti/41Sc/42Sc (T 1/2 = 509-680 ms) on calcium, 28P (T 1/2 = 268 ms) on phosphorus. A translation of the results from elemental targets to PMMA and representative tissues such as adipose tissue, muscle, compact and cortical bone, shows the dominance of 13O/12N in at least the first 20 s of an irradiation with 4He and somewhat longer with 3He. As the production of 13O/12N in a 3He irradiation is 3-4 times higher than in a 4He irradiation, from a statistical point of view, range verification using 13O/12N PET imaging will be about 2 times more precise for a 3He irradiation compared to a 4He irradiation.


Assuntos
Hélio/uso terapêutico , Tomografia por Emissão de Pósitrons/métodos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Meia-Vida , Humanos
12.
Radiother Oncol ; 137: 125-129, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31085392

RESUMO

To optimize beam delivery and conformality of proton therapy, MRI integration has been proposed. Therefore, we investigated if proton irradiation in a magnetic field would change biological responses. Our data in cancer cell lines and stem cell-derived organoid models suggest that a magnetic field does not modify the biological response.


Assuntos
Adenocarcinoma de Pulmão/terapia , Magnetoterapia/métodos , Terapia com Prótons/métodos , Glândulas Salivares/efeitos da radiação , Células A549 , Adenocarcinoma de Pulmão/radioterapia , Animais , Feminino , Células HEK293 , Humanos , Imageamento por Ressonância Magnética/métodos , Camundongos , Camundongos Endogâmicos C57BL , Glândulas Salivares/citologia , Células-Tronco/citologia , Células-Tronco/efeitos da radiação
13.
Clin Cancer Res ; 24(24): 6583-6593, 2018 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-30135147

RESUMO

PURPOSE: Radiotherapy for head and neck cancer may result in serious side effects, such as hyposalivation, impairing the patient's quality of life. Modern radiotherapy techniques attempt to reduce the dose to salivary glands, which, however, results in low-dose irradiation of the tissue stem cells. Here we assess the low-dose sensitivity of tissue stem cells and the consequences for tissue function. EXPERIMENTAL DESIGN: Postirradiation rat salivary gland secretory function was determined after pilocarpine induction. Murine and patient-derived salivary gland and thyroid gland organoids were irradiated and clonogenic survival was assessed. The DNA damage response (DDR) was analyzed in organoids and modulated using different radiation modalities, chemical inhibition, and genetic modification. RESULTS: Relative low-dose irradiation to the high-density stem cell region of rat salivary gland disproportionally impaired function. Hyper-radiosensitivity at doses <1 Gy, followed by relative radioresistance at doses ≥1 Gy, was observed in salivary gland and thyroid gland organoid cultures. DDR modulation resulted in diminished, or even abrogated, relative radioresistance. Furthermore, inhibition of the DDR protein ATM impaired DNA repair after 1 Gy, but not 0.25 Gy. Irradiation of patient-derived salivary gland organoid cells showed similar responses, whereas a single 1 Gy dose to salivary gland-derived stem cells resulted in greater survival than clinically relevant fractionated doses of 4 × 0.25 Gy. CONCLUSIONS: We show that murine and human glandular tissue stem cells exhibit a dose threshold in DDR activation, resulting in low-dose hyper-radiosensitivity, with clinical implications in radiotherapy treatment planning. Furthermore, our results from patient-derived organoids highlight the potential of organoids to study normal tissue responses to radiation.


Assuntos
Células-Tronco Adultas/metabolismo , Células-Tronco Adultas/efeitos da radiação , Dano ao DNA/efeitos da radiação , Suscetibilidade a Doenças , Doses de Radiação , Radiação Ionizante , Animais , Relação Dose-Resposta à Radiação , Imunofluorescência , Humanos , Masculino , Camundongos , Camundongos Knockout , Ratos
14.
Int J Radiat Oncol Biol Phys ; 69(2): 552-9, 2007 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-17869668

RESUMO

PURPOSE: To test the hypothesis that heart irradiation increases the risk of a symptomatic radiation-induced loss of lung function (SRILF) and that this can be well-described as a modulation of the functional reserve of the lung. METHODS AND MATERIALS: Rats were irradiated with 150-MeV protons. Dose-response curves were obtained for a significant increase in breathing frequency after irradiation of 100%, 75%, 50%, or 25% of the total lung volume, either including or excluding the heart from the irradiation field. A significant increase in the mean respiratory rate after 6-12 weeks compared with 0-4 weeks was defined as SRILF, based on biweekly measurements of the respiratory rate. The critical volume (CV) model was used to describe the risk of SRILF. Fits were done using a maximum likelihood method. Consistency between model and data was tested using a previously developed goodness-of-fit test. RESULTS: The CV model could be fitted consistently to the data for lung irradiation only. However, this fitted model failed to predict the data that also included heart irradiation. Even refitting the model to all data resulted in a significant difference between model and data. These results imply that, although the CV model describes the risk of SRILF when the heart is spared, the model needs to be modified to account for the impact of dose to the heart on the risk of SRILF. Finally, a modified CV model is described that is consistent to all data. CONCLUSIONS: The detrimental effect of dose to the heart on the incidence of SRILF can be described by a dose dependent decrease in functional reserve of the lung.


Assuntos
Coração/efeitos da radiação , Pulmão/efeitos da radiação , Respiração/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Pulmão/fisiopatologia , Modelos Biológicos , Lesões Experimentais por Radiação/fisiopatologia , Ratos , Ratos Wistar
15.
Int J Radiat Oncol Biol Phys ; 95(1): 103-111, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27084633

RESUMO

PURPOSE: A reduction in the dose, irradiated volume, and sensitivity of, in particular, normal tissue stem cells is needed to advance radiation therapy. This could be obtained with the use of particles for radiation therapy. However, the radiation response of normal tissue stem cells is still an enigma. Therefore, in the present study, we developed a model to investigate the in vitro response of stem cells to particle irradiation. METHODS AND MATERIALS: We used the immortalized human salivary gland (HSG) cell line resembling salivary gland (SG) cells to translate the radiation response in 2-dimensional (2D) to 3-dimensional (3D) conditions. This response was subsequently translated to the response of SG stem cells (SGSCs). Dispersed single cells were irradiated with photons or carbon ions at different linear energy transfers (LETs; 48.76 ± 2.16, 149.9 ± 10.8, and 189 ± 15 keV/µm). Subsequently, 2D or 3D clonogenicity was determined by counting the colonies or secondary stem cell-derived spheres in Matrigel. γH2AX immunostaining was used to assess DNA double strand break repair. RESULTS: The 2D response of HSG cells showed a similar increase in dose response to increasing higher LET irradiation as other cell lines. The 3D response of HSG cells to increasing LET irradiation was reduced compared with the 2D response. Finally, the response of mouse SGSCs to photons was similar to the 3D response of HSG cells. The response to higher LET irradiation was reduced in the stem cells. CONCLUSIONS: Mouse SGSC radiosensitivity seems reduced at higher LET radiation compared with transformed HSG cells. The developed model to assess the radiation response of SGSCs offers novel possibilities to study the radiation response of normal tissue in vitro.


Assuntos
Radioterapia com Íons Pesados , Transferência Linear de Energia , Fótons , Tolerância a Radiação , Células-Tronco/efeitos da radiação , Glândula Submandibular/citologia , Técnicas de Cultura de Células , Linhagem Celular Transformada , Sobrevivência Celular/efeitos da radiação , Radioisótopos de Césio , Colágeno , Ensaio de Unidades Formadoras de Colônias/métodos , Quebras de DNA de Cadeia Dupla , Combinação de Medicamentos , Histonas/análise , Humanos , Técnicas In Vitro , Laminina , Proteoglicanas , Esferoides Celulares/citologia , Esferoides Celulares/efeitos da radiação
16.
Int J Radiat Oncol Biol Phys ; 94(1): 163-171, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26700710

RESUMO

PURPOSE: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed the dose-limiting toxicity. METHODS AND MATERIALS: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. RESULTS: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. CONCLUSIONS: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late RILD are also due to different pathologies. As such, new radiation techniques reducing irradiated volume might change the dose-limiting toxicity of the radiation therapy treatment.


Assuntos
Pulmão/irrigação sanguínea , Pulmão/efeitos da radiação , Lesões Experimentais por Radiação/prevenção & controle , Pneumonite por Radiação/patologia , Taxa Respiratória/efeitos da radiação , Animais , Vasos Sanguíneos/patologia , Vasos Sanguíneos/efeitos da radiação , Modelos Animais de Doenças , Relação Dose-Resposta à Radiação , Hipertrofia/etiologia , Hipertrofia/patologia , Masculino , Órgãos em Risco/irrigação sanguínea , Órgãos em Risco/efeitos da radiação , Prótons , Lesões Experimentais por Radiação/patologia , Pneumonite por Radiação/etiologia , Ratos , Ratos Wistar , Fatores de Tempo
17.
IEEE Trans Med Imaging ; 35(4): 1099-105, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26701179

RESUMO

The development of a proton radiography system to improve the imaging of patients in proton beam therapy is described. The system comprises gridpix based time projection chambers, which are based on the Timepix chip designed by the Medipix collaboration, for tracking the protons. This type of detector was chosen to have minimal impact on the actual determination of the proton tracks by the tracking detectors. To determine the residual energy of the protons, a BaF 2 crystal with a photomultiplier tube is used. We present data taken in a feasibility experiment with phantoms that represent tissue equivalent materials found in the human body. The obtained experimental results show a good agreement with the performed simulations.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Prótons , Radiografia/instrumentação , Radiografia/métodos
18.
Phys Med Biol ; 60(9): 3825-46, 2015 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-25905890

RESUMO

Radiotherapy and particle therapy treatment planning require accurate knowledge of the electron density and elemental composition of the tissues in the beam path to predict the local dose deposition. We describe a method for the analysis of dual energy computed tomography (DECT) images that provides the electron densities and effective atomic numbers of tissues. The CT measurement process is modelled by system weighting functions, which apply an energy dependent weighting to the parameterization of the total cross section for photon interactions with matter. This detailed parameterization is based on the theoretical analysis of Jackson and Hawkes and deviates, at most, 0.3% from the tabulated NIST values for the elements H to Zn. To account for beam hardening in the object as present in the CT image we implemented an iterative process employing a local weighting function, derived from the method proposed by Heismann and Balda. With this method effective atomic numbers between 1 and 30 can be determined. The method has been experimentally validated on a commercially available tissue characterization phantom with 16 inserts made of tissue substitutes and aluminium that has been scanned on a dual source CT system with tube potentials of 100 kV and 140 kV using a clinical scan protocol. Relative electron densities of all tissue substitutes have been determined with accuracy better than 1%. The presented DECT analysis method thus provides high accuracy electron densities and effective atomic numbers for radiotherapy and especially particle therapy treatment planning.


Assuntos
Algoritmos , Elétrons , Fótons , Prótons , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
19.
Radiother Oncol ; 114(1): 96-103, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25465731

RESUMO

BACKGROUND AND PURPOSE: In thoracic irradiation, the maximum radiation dose is restricted by the risk of radiation-induced cardiopulmonary damage and dysfunction limiting tumor control. We showed that radiation-induced sub-clinical cardiac damage and lung damage in rats mutually interact and that combined irradiation intensifies cardiopulmonary toxicity. Unfortunately, current clinical practice does not include preventative measures to attenuate radiation-induced lung or cardiac toxicity. Here, we investigate the effects of the ACE inhibitor captopril on radiation-induced cardiopulmonary damage. MATERIAL AND METHODS: After local irradiation of rat heart and/or lungs captopril was administered orally. Cardiopulmonary performance was assessed using biweekly breathing rate measurements. At 8 weeks post-irradiation, cardiac hemodynamics were measured, CT scans and histopathology were analyzed. RESULTS: Captopril significantly improved breathing rate and cardiopulmonary density/structure, but only when the heart was included in the radiation field. Consistently, captopril reduced radiation-induced pleural and pericardial effusion and cardiac fibrosis, resulting in an improved left ventricular end-diastolic pressure only in the heart-irradiated groups. CONCLUSION: Captopril improves cardiopulmonary morphology and function by reducing acute cardiac damage, a risk factor in the development of radiation-induced cardiopulmonary toxicity. ACE inhibition should be evaluated as a strategy to reduce cardiopulmonary complications induced by radiotherapy to the thoracic area.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/farmacologia , Captopril/farmacologia , Coração/efeitos da radiação , Pulmão/efeitos da radiação , Lesões por Radiação/prevenção & controle , Animais , Masculino , Ratos Wistar , Taxa Respiratória/efeitos da radiação , Neoplasias Torácicas/radioterapia , Remodelação Vascular/efeitos da radiação
20.
Sci Transl Med ; 7(305): 305ra147, 2015 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-26378247

RESUMO

Each year, 500,000 patients are treated with radiotherapy for head and neck cancer, resulting in relatively high survival rates. However, in 40% of patients, quality of life is severely compromised because of radiation-induced impairment of salivary gland function and consequent xerostomia (dry mouth). New radiation treatment technologies enable sparing of parts of the salivary glands. We have determined the parts of the major salivary gland, the parotid gland, that need to be spared to ensure that the gland continues to produce saliva after irradiation treatment. In mice, rats, and humans, we showed that stem and progenitor cells reside in the region of the parotid gland containing the major ducts. We demonstrated in rats that inclusion of the ducts in the radiation field led to loss of regenerative capacity, resulting in long-term gland dysfunction with reduced saliva production. Then we showed in a cohort of patients with head and neck cancer that the radiation dose to the region of the salivary gland containing the stem/progenitor cells predicted the function of the salivary glands one year after radiotherapy. Finally, we showed that this region of the salivary gland could be spared during radiotherapy, thus reducing the risk of post-radiotherapy xerostomia.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Glândula Parótida/efeitos da radiação , Radioterapia/métodos , Glândulas Salivares/patologia , Glândulas Salivares/efeitos da radiação , Células-Tronco/citologia , Animais , Humanos , Camundongos , Glândula Parótida/metabolismo , Qualidade de Vida , Radioterapia/efeitos adversos , Ratos , Saliva/metabolismo , Glândulas Salivares/metabolismo , Xerostomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA