Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Eur Radiol ; 29(5): 2330-2339, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30547201

RESUMO

OBJECTIVES: Cardiac magnetic resonance (CMR) is the gold-standard modality for the assessment of left ventricular (LV) remodeling in ST-elevation myocardial infarction (STEMI) patients. However, the commonly used remodeling criteria have never been validated for hard clinical events. We therefore aimed to define clear CMR criteria of LV remodeling following STEMI with proven prognostic impact. METHODS: This observational study included 224 patients suffering from acute STEMI. CMR was performed within 1 week and 4 months after infarction to evaluate different remodeling criteria including relative changes in LV end-diastolic volume (%∆LVEDV), end-systolic volume (%∆LVESV), ejection fraction (%∆LVEF), and myocardial mass (%∆LVMM). Primary endpoint was the occurrence of major adverse cardiovascular events (MACE) including all-cause death, re-infarction, stroke, and new congestive heart failure 24 months following STEMI. Secondary endpoint was defined as composite of primary endpoint and cardiovascular hospitalization. The Mann-Whitney U test was applied to assess differences in LV remodeling measures between patients with and without MACE. Values for the prediction of primary and secondary endpoints were assessed by c-statistics and Cox regression analysis. RESULTS: The incidence of MACE (n = 13, 6%) was associated with higher %∆LVEDV (p = 0.002) and %∆LVMM (p = 0.02), whereas %∆LVESV and %∆LVEF were not significantly related to MACE (p > 0.05). The area under the curve (AUC) for the prediction of MACE was 0.76 (95% confidence interval [CI], 0.65-0.87) for %∆LVEDV (optimal cut-off 10%) and 0.69 (95%CI, 0.52-0.85) for %∆LVMM (optimal cut-off 5%). From all remodeling criteria, %∆LVEDV ≥ 10% showed highest hazard ratio (8.68 [95%CI, 2.39-31.56]; p = 0.001) for MACE. Regarding secondary endpoint (n = 35, 16%), also %∆LVEDV with an optimal threshold of 10% emerged as strongest prognosticator (AUC 0.66; 95%CI, 0.56-0.75; p = 0.004). CONCLUSIONS: Following revascularized STEMI, %∆LVEDV ≥ 10% showed strongest association with clinical outcome, suggesting this criterion as preferred CMR-based definition of post-STEMI LV remodeling. KEY POINTS: • CMR-determined %∆LVEDV and %∆LVMM were significantly associated with MACE following STEMI. • Neither %∆LVESV nor %∆LVEF showed a significant relation to MACE. • %∆LVEDV ≥ 10 was revealed as LV remodeling definition with highest prognostic validity.


Assuntos
Imageamento por Ressonância Magnética , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Remodelação Ventricular , Idoso , Área Sob a Curva , Feminino , Coração/fisiopatologia , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Prognóstico , Modelos de Riscos Proporcionais , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Volume Sistólico , Função Ventricular Esquerda
2.
Interact Cardiovasc Thorac Surg ; 32(5): 711-718, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33484126

RESUMO

OBJECTIVES: Transit-time flow measurement is a recognized method for graft evaluation in coronary surgery. However, single flow measurement has been associated with a low specificity for detecting graft dysfunction. The goal of this study was to assess the value of transit-time flow measurement for assessing in situ internal mammary artery grafts during non-existent native coronary circulation and the relevance of collateral blood flow in target vessels. METHODS: Between 2014 and 2018, a total of 134 patients undergoing on-pump coronary artery bypass grafting were evaluated using transit-time flow measurement. We analysed 111 single left internal mammary artery and 57 single right internal mammary artery bypasses. Correlations between coronary relevant parameters were calculated using Spearman's ρ coefficient. Risk factors for decreased flow with an arrested heart (FAH) <30 ml/min and an increased pulsatility index (PI) >3.0 as well as flow reduction >30% were calculated. RESULTS: FAH correlated with the diameter of the target vessel (Spearman's ρ = 0.32; P < 0.001), the amount of blood distribution (Spearman's ρ = 0.34; P < 0.001), the PI (Spearman's ρ = 0.19; P = 0.019) and the degree of stenosis (Spearman's ρ = -0.17; P = 0.042). The percentage of flow change was found to correlate with the PI (Spearman's ρ = -0.47; P < 0.0001), the degree of stenosis (Spearman's ρ = 0.42; P < 0.001), the diameter of the target vessel (Spearman's ρ = -0.22; P = 0.008) and the area of blood distribution (Spearman's ρ = -0.19; P = 0.018). A small blood distribution area was the only risk factor for decreased FAH [odds ratio (OR) 8.43, confidence interval (CI) 95% (3.04-23.41); P < 0.001]. Binary logistic regression identified PI [OR 2.05, CI 95% (1.36-3.10); P = 0.001], FAH [OR 0.98, CI 95% (0.97-0.99); P = 0.005] and degree of stenosis [OR 0.95, CI 95% (0.92-0.99); P = 0.011] as risk factors for decreased flow after cardiopulmonary bypass (<30 ml/min). An increased PI (>3) was mainly influenced by percentage of flow change [OR 0.99, CI 95% (0.98-1.00); P = 0.031]. CONCLUSIONS: FAH and percentage of flow change are related to the dimensions of the target vessel and the degree of stenosis. The addition of flow measurements with the heart arrested provides additional information about the bypass graft, the quality of the anastomosis and the physiology of the coronary circulation.


Assuntos
Ponte de Artéria Coronária , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Coração , Humanos , Artéria Torácica Interna , Grau de Desobstrução Vascular
3.
Lasers Surg Med ; 38(1): 52-61, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16283631

RESUMO

BACKGROUND AND OBJECTIVES: To explore the potential of Er:YAG-laser irradiation for precise and tractionless retinal tissue and inner limiting membrane ablation. MATERIALS AND METHODS: We used free-running Er:YAG-laser irradiation (lambda = 2.94 microm) transmitted either through a 10 cm long low-OH-quartz fiber or a 2 m long sapphire fiber that produced a more homogenous light distribution at the fiber tip. Retinal ablation in porcine retinal explants was performed under air or perfluorodecaline (PFD). Ablation depth was evaluated by optical coherence tomography (OCT) and from histologic sections. RESULTS: A radiant exposure of 5.0 J/cm(2) delivered through a low-OH-quartz fiber and PFD caused a complete transsection of the neurosensory retina. Radiant exposures between 3.5 and 2.0 J/cm(2) resulted in marked variations of ablation depth and adjacent thermal damage. By contrast, laser pulses of 4.0 and 3.0 J/cm(2) transmitted through the sapphire fiber produced more homogenous defect patterns and less thermal damage. Close to the ablation threshold, with 1.0-2.0 J/cm(2), ablation was limited to a 10-20 microm thin layer of the neural retina. CONCLUSIONS: We achieved in vitro ablation of inner retinal layers, but could not produce selective and reproducible ILM removal.


Assuntos
Terapia a Laser/instrumentação , Procedimentos Cirúrgicos Oftalmológicos/instrumentação , Retina/cirurgia , Animais , Érbio , Técnicas In Vitro , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA