Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Audiol ; : 1-8, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38319187

RESUMO

OBJECTIVE: to evaluate the levels of successful hearing preservation and preservation of functional hearing following cochlear implantation (HPCI) in children using the Cochlear Nucleus® Slim Straight Electrode (SSE). DESIGN: retrospective case note review of paediatric HPCI cases in our CI centre from 2013 to 2023. Inclusion criteria were attempted hearing preservation surgery, SSE used for implantation, pre-operative hearing thresholds ≤80dBHL at 250 Hz, CI before 18 years of age. Patients were excluded if no postoperative unaided PTA was obtained (poor attendance). Primairy outcome was hearing preservation using the HEARRING group formula; secondary outcome was residual functional hearing (≤80dBHL at 250 Hz/<90dB LFPTA). STUDY SAMPLE: 56 patients with 94 CI's were included for review. RESULTS: Hearing preservation was achieved in 94.7% (89/94) of ears and complete preservation in 72% (68/94)). Average functional hearing was preserved in 89% using both criteria for preservation. Long-term follow up data was available for 36 ears (average 35.2 months), demonstrating 88.9% (32/36) complete preservation. CONCLUSION: We have reliably achieved and maintained a high success rate of HPCI using the SSE in our paediatric population. The field of HPCI would benefit from unification of outcome reporting in order to optimise the evidence available to professionals, patients and their carers.

2.
J Adv Nurs ; 2024 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-38186205

RESUMO

AIM: To explore the views of neonatal intensive care nursing staff on the deliverability of a novel genetic point-of-care test detecting a genetic variant associated with antibiotic-induced ototoxicity. DESIGN: An interpretive, descriptive, qualitative interview study. METHODS: Data were collected using semi-structured interviews undertaken between January and November 2020. Participants were neonatal intensive care nursing staff taking part in the Pharmacogenetics to Avoid Loss of Hearing trial. RESULTS: Thematic analysis resulted in four themes: perceived clinical utility; the golden hour; point-of-care device; training and support. Recommendations were made to streamline the protocol and ongoing training and support were considered key to incorporating the test into routine care. CONCLUSION: Exploring the views of nurses involved in the delivery of the point-of-care test was essential in its implementation. By the study endpoint, all participants could see the value of routine clinical introduction of the point-of care test. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: Nurses are in a key position to support the delivery of point-of-care genetic testing into mainstream settings. This study has implications for the successful integration of other genetic point-of-care tests in acute healthcare settings. IMPACT: The study will help to tailor the training and support required for routine deployment of the genetic point-of-care test. The study has relevance for nurses involved in the development and delivery of genetic point-of-care tests in other acute hospital settings. REPORTING METHOD: This qualitative study adheres to the Standards for Reporting Qualitative Research EQUATOR guidelines and utilizes COREQ and SRQR checklists. PATIENT OR PUBLIC CONTRIBUTION: All staff working on the participating neonatal intensive care units were trained to use the genetic point-of-care test. All inpatients on the participating units were eligible to have testing via the point-of-care test. The Pharmacogenetics to Avoid Loss of Hearing Patient and Public Involvement and Engagement group provided valuable feedback. TRIAL AND PROTOCOL REGISTRATION: Registered within the University of Manchester. Ethics approval reference numbers: IRAS: 253102 REC reference: 19/NW/0400. Also registered with the ISRCTN ref: ISRCTN13704894.

3.
Clin Otolaryngol ; 49(1): 74-86, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37828806

RESUMO

OBJECTIVES: Technological advancements in mobile audiometry (MA) have enabled hearing assessment using tablets and smartphones. This systematic review (PROSPERO ID: CRD42021274761) aimed to identify MA options available to health providers, assess their accuracy in measuring hearing thresholds, and explore factors that might influence their accuracy. DESIGN AND SETTING: A systematic search of online databases including PubMed, Embase, Cochrane, Evidence Search and Dynamed was conducted on 13th December 2021, and repeated on 30th October 2022, using appropriate Medical Subject Headings (MeSH) terms. Eligible studies reported the use of MA to determine hearing thresholds and compared results to conventional pure-tone audiometry (CA). Studies investigating MA for hearing screening (i.e. reporting just pass/fail) were ineligible for inclusion. Two authors independently reviewed studies, extracted data, and assessed methodological quality and risk of bias using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. PARTICIPANTS: Adults and children, with and without diagnosis of hearing impairment. MAIN OUTCOME MEASURES: A meta-analysis was performed to obtain the mean difference between thresholds measured using MA and CA in dB HL. RESULTS: Searches returned 858 articles. After systematic review, 17 articles including 1032 participants were analysed. The most used software application was ShoeboxTM (6/17) followed by Hearing TestTM (3/17), then HearTestTM (2/17). Tablet computers were used in ten studies, smartphones in six, and a computer in one. The mean difference between MA and CA thresholds was 1.36 dB (95% CI, 0.07-2.66, p = 0.04). Significant differences between mobile audiometry (MA) and conventional audiometry (CA) thresholds were observed in thresholds measured at 500Hz, in children, when MA was conducted in a sound booth, and when MA was self-administered. However, these differences did not exceed the clinically significant threshold of 10 decibels (dB). Included studies exhibited high levels of heterogeneity, high risk of bias and low concerns about applicability. CONCLUSIONS: MA compares favourably to CA in measuring hearing thresholds and has role in providing access to hearing assessment in situations where CA is not available or feasible. Future studies should prioritize the integration of pure-tone threshold assessment with additional tests, such as Speech Recognition and Digits-in-Noise, for a more rounded evaluation of hearing ability, assesses acceptability and feasibility, and the cost-effectiveness of MA in non-specialist settings.


Assuntos
Perda Auditiva , Audição , Adulto , Criança , Humanos , Limiar Auditivo , Perda Auditiva/diagnóstico , Audiometria , Audiometria de Tons Puros/métodos , Smartphone
4.
Clin Otolaryngol ; 49(1): 62-73, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37794685

RESUMO

OBJECTIVES: Chronic suppurative otitis media (CSOM) is defined as persistent discharge through a tympanic membrane perforation for greater than 2 weeks. It is associated with a significant disease burden, including hearing loss, and reducing its incidence could significantly improve short- and long-term health. We aimed to identify risk factors associated with the development of CSOM in children. DESIGN AND SETTING: Systematic review and meta-analysis of studies set in community, primary and secondary care settings, identified from Medline, Embase and Cochrane databases from 2000 to 2022. PARTICIPANTS: Children 16 years old and below. MAIN OUTCOME MEASURES: Clinical diagnosis of CSOM. RESULTS: In total, 739 papers were screened, with 12 deemed eligible for inclusion in the systematic review, of which, 10 were included in the meta-analysis. Risk factors examined included perinatal, patient, dietary, environmental and parental factors. Meta-analysis results indicate that atopy (RR = 1.18, 95% CI [1.01-1.37], p = .04, 2 studies); and birth weight <2500 g (RR = 1.79 [1.27-2.50], p < .01, 2 studies) are associated with an increased risk of CSOM development. Factors not associated were male sex (RR = 0.96 [0.82-1.13], p = .62, 8 studies); exposure to passive smoking (RR = 1.27 [0.81-2.01], p = .30, 3 studies); and parental history of otitis media (RR = 1.14 [0.59-2.20], p = .69, 2 studies). CONCLUSION: Optimal management of risk factors associated with CSOM development will help reduce the burden of disease and prevent disease progression or recurrence. The current quality of evidence in the literature is variable and heterogeneous. Future studies should aim to use standardised classification systems to define risk factors to allow meta-analysis.


Assuntos
Perda Auditiva , Otite Média Supurativa , Otite Média , Criança , Humanos , Masculino , Adolescente , Feminino , Otite Média Supurativa/complicações , Otite Média Supurativa/epidemiologia , Doença Crônica , Otite Média/complicações , Perda Auditiva/etiologia , Fatores de Risco
5.
Neuroimage ; 270: 119993, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36863550

RESUMO

High-resolution diffusion tensor imaging (DTI) can noninvasively probe the microstructure of cortical gray matter in vivo. In this study, 0.9-mm isotropic whole-brain DTI data were acquired in healthy subjects with an efficient multi-band multi-shot echo-planar imaging sequence. A column-based analysis that samples the fractional anisotropy (FA) and radiality index (RI) along radially oriented cortical columns was then performed to quantitatively analyze the FA and RI dependence on the cortical depth, cortical region, cortical curvature, and cortical thickness across the whole brain, which has not been simultaneously and systematically investigated in previous studies. The results showed characteristic FA and RI vs. cortical depth profiles, with an FA local maximum and minimum (or two inflection points) and a single RI maximum at intermediate cortical depths in most cortical regions, except for the postcentral gyrus where no FA peaks and a lower RI were observed. These results were consistent between repeated scans from the same subjects and across different subjects. They were also dependent on the cortical curvature and cortical thickness in that the characteristic FA and RI peaks were more pronounced i) at the banks than at the crown of gyri or at the fundus of sulci and ii) as the cortical thickness increases. This methodology can help characterize variations in microstructure along the cortical depth and across the whole brain in vivo, potentially providing quantitative biomarkers for neurological disorders.


Assuntos
Imagem de Tensor de Difusão , Substância Cinzenta , Humanos , Imagem de Tensor de Difusão/métodos , Substância Cinzenta/diagnóstico por imagem , Anisotropia , Encéfalo , Imagem Ecoplanar
6.
Ear Hear ; 44(5): 1157-1172, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37019441

RESUMO

OBJECTIVES: The cortical auditory evoked potential (CAEP) test is a candidate for supplementing clinical practice for infant hearing aid users and others who are not developmentally ready for behavioral testing. Sensitivity of the test for given sensation levels (SLs) has been reported to some degree, but further data are needed from large numbers of infants within the target age range, including repeat data where CAEPs were not detected initially. This study aims to assess sensitivity, repeatability, acceptability, and feasibility of CAEPs as a clinical measure of aided audibility in infants. DESIGN: One hundred and three infant hearing aid users were recruited from 53 pediatric audiology centers across the UK. Infants underwent aided CAEP testing at age 3 to 7 months to a mid-frequency (MF) and (mid-)high-frequency (HF) synthetic speech stimulus. CAEP testing was repeated within 7 days. When developmentally ready (aged 7-21 months), the infants underwent aided behavioral hearing testing using the same stimuli, to estimate the decibel (dB) SL (i.e., level above threshold) of those stimuli when presented at the CAEP test sessions. Percentage of CAEP detections for different dB SLs are reported using an objective detection method (Hotellings T 2 ). Acceptability was assessed using caregiver interviews and a questionnaire, and feasibility by recording test duration and completion rate. RESULTS: The overall sensitivity for a single CAEP test when the stimuli were ≥0 dB SL (i.e., audible) was 70% for the MF stimulus and 54% for the HF stimulus. After repeat testing, this increased to 84% and 72%, respectively. For SL >10 dB, the respective MF and HF test sensitivities were 80% and 60% for a single test, increasing to 94% and 79% for the two tests combined. Clinical feasibility was demonstrated by an excellent >99% completion rate, and acceptable median test duration of 24 minutes, including preparation time. Caregivers reported overall positive experiences of the test. CONCLUSIONS: By addressing the clinical need to provide data in the target age group at different SLs, we have demonstrated that aided CAEP testing can supplement existing clinical practice when infants with hearing loss are not developmentally ready for traditional behavioral assessment. Repeat testing is valuable to increase test sensitivity. For clinical application, it is important to be aware of CAEP response variability in this age group.


Assuntos
Perda Auditiva Neurossensorial , Percepção da Fala , Criança , Humanos , Lactente , Estimulação Acústica/métodos , Fala , Estudos de Viabilidade , Perda Auditiva Neurossensorial/reabilitação , Potenciais Evocados Auditivos/fisiologia , Percepção da Fala/fisiologia
7.
J Med Genet ; 59(4): 393-398, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33879512

RESUMO

PURPOSE: The increased adoption of genomic strategies in the clinic makes it imperative for diagnostic laboratories to improve the efficiency of variant interpretation. Clinical exome sequencing (CES) is becoming a valuable diagnostic tool, capable of meeting the diagnostic demand imposed by the vast array of different rare monogenic disorders. We have assessed a clinician-led and phenotype-based approach for virtual gene panel generation for analysis of targeted CES in patients with rare disease in a single institution. METHODS: Retrospective survey of 400 consecutive cases presumed by clinicians to have rare monogenic disorders, referred on singleton basis for targeted CES. We evaluated diagnostic yield and variant workload to characterise the usefulness of a clinician-led approach for generation of virtual gene panels that can incorporate up to three different phenotype-driven gene selection methods. RESULTS: Abnormalities of the nervous system (54.5%), including intellectual disability, head and neck (19%), skeletal system (16%), ear (15%) and eye (15%) were the most common clinical features reported in referrals. Combined phenotype-driven strategies for virtual gene panel generation were used in 57% of cases. On average, 7.3 variants (median=5) per case were retained for clinical interpretation. The overall diagnostic rate of proband-only CES using personalised phenotype-driven virtual gene panels was 24%. CONCLUSIONS: Our results show that personalised virtual gene panels are a cost-effective approach for variant analysis of CES, maintaining diagnostic yield and optimising the use of resources for clinical genomic sequencing in the clinic.


Assuntos
Exoma , Doenças Raras , Exoma/genética , Humanos , Doenças Raras/genética , Estudos Retrospectivos , Sequenciamento do Exoma , Carga de Trabalho
8.
Cleft Palate Craniofac J ; 59(2): 254-261, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33792409

RESUMO

OBJECTIVE: Cleft palate (CP) can affect breathing, leading to sleep-disordered breathing (SDB). Sleep position can affect SDB, but the optimum sleep position for infants with CP is unknown. We aimed to determine the design of a pragmatic study to investigate the effect of the 2 routinely advised sleep positions in infants with CP on oxygen saturations. DESIGN: A multicentered observational cohort. SETTING: Four UK-based cleft centers, 2 advising supine- and 2 side-lying sleep positions for infants with CP. PARTICIPANTS: Infants with isolated CP born July 1, 2015, and December 31, 2016. Of 48 eligible infants, 30 consented (17 side-lying; 13 supine). INTERVENTIONS: Oxygen saturation (SpO2) and end-tidal carbon dioxide (ETCO2) home monitoring at age 1 and 3 months. Qualitative interviews of parents. OUTCOME MEASURES: Willingness to participate, recruitment, retention, and acceptability/success (>90 minutes recording) of SpO2 and ETCO2 monitoring. RESULTS: SpO2 recordings were obtained during 50 sleep sessions on 24 babies (13 side-lying) at 1 month (34 sessions >90 minutes) and 50 sessions on 19 babies (10 side-lying) at 3 months (27 sessions >90 minutes). The ETCO2 monitoring was only achieved in 12 sessions at 1 month and 6 at 3 months; only 1 was >90 minutes long. The ETCO2 monitoring was reported by the majority as unacceptable. Parents consistently reported the topic of sleep position in CP to be of importance. CONCLUSIONS: This study has demonstrated that it is feasible to perform domiciliary oxygen saturation studies in a research setting and has suggested that there may be a difference in the effects of sleep position that requires further investigation. We propose a study with randomization is indicated, comparing side-lying with supine-lying sleep position, representing an important step toward better understanding of SDB in infants with CP.


Assuntos
Fissura Palatina , Síndromes da Apneia do Sono , Estudos de Coortes , Estudos de Viabilidade , Humanos , Lactente , Sono , Decúbito Dorsal
9.
Clin Otolaryngol ; 47(2): 279-286, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34213821

RESUMO

OBJECTIVES: A dose of 5 mg/kg lidocaine is considered appropriate for paediatric airway topicalisation. Existing literature suggests that younger children are susceptible to toxic lidocaine plasma levels and achieve this at a faster rate. MAIN OUTCOME MEASURES: The primary outcome of this study was to ascertain peak plasma lidocaine levels after topicalisation for airway endoscopy. Secondary endpoints included: time to peak lidocaine plasma levels, signs of lidocaine toxicity (restricted to ECG changes or seizures when under anaesthesia) and clinical adverse events of laryngospasm, coughing or desaturation during the procedure. SETTING: Data were collected prospectively over 18 months at Royal Manchester Children's Hospital. PARTICIPANTS: Children aged 0-8 years undergoing elective diagnostic or therapeutic airway endoscopy were included within the study. DESIGN: Standardised 2% lidocaine was used for airway topicalisation. Dose varied depending upon the practitioner's usual practice. Venous bloodsampling occurred at 5, 10, 15 and 20 min post-administration and plasma lidocaine levels (ng/ml) were analysed. RESULTS: A significant relationship exists between higher peak plasma levels and ages <18 months (p = .00973). Strong linear correlation exists between body weight and age for our cohort (r = .88). Higher peak plasma lidocaine levels occur with total dose volumes between 2 and 3 mls of 2% lidocaine local anaesthetic (p = .03) compared with <2 ml total dose volumes. Data suggest a potential relationship of lower body weights achieving higher peak plasma levels (p = .0516). Reduced interquartile variation of peak plasma lidocaine levels exists when lidocaine dosing is <5 mg/kg. CONCLUSIONS: Age and total dose volume of topicalised lidocaine have a significant relationship with plasma lidocaine levels. A dose of 5 mg/kg topicalised lidocaine for paediatric airway endoscopy is safe and provides good operating conditions. Lower patient body weights trend towards higher peak lidocaine plasma concentrations and require further investigation.


Assuntos
Endoscopia/métodos , Laringoscopia/métodos , Lidocaína/administração & dosagem , Lidocaína/sangue , Administração Tópica , Anestésicos Locais/administração & dosagem , Anestésicos Locais/sangue , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Estudos Prospectivos
10.
Clin Otolaryngol ; 47(1): 120-130, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34606691

RESUMO

OBJECTIVES: To explore the impact of COVID-19 on the management and outcomes of acute paediatric mastoiditis across the UK. DESIGN: National retrospective and prospective audit. SETTING: 48 UK secondary care ENT departments. PARTICIPANTS: Consecutive children aged 18 years or under, referred to ENT with a clinical diagnosis of mastoiditis. MAIN OUTCOME MEASURES: Cases were divided into Period 1 (01/11/19-15/03/20), before the UK population were instructed to reduce social contact, and Period 2 (16/03/20-30/04/21), following this. Periods 1 and 2 were compared for population variables, management and outcomes. Secondary analyses compared outcomes by primary treatment (medical/needle aspiration/surgical). RESULTS: 286 cases met criteria (median 4 per site, range 0-24). 9.4 cases were recorded per week in period 1 versus 2.0 in period 2, with no winter increase in cases in December 2020-Febraury 2021. Patient age differed between periods 1 and 2 (3.2 vs 4.7 years respectively, p < 0.001). 85% of children in period 2 were tested for COVID-19 with a single positive test. In period, 2 cases associated with P. aeruginosa significantly increased. 48.6% of children were scanned in period 1 vs 41.1% in period 2. Surgical management was used more frequently in period 1 (43.0% vs 24.3%, p = 0.001). Treatment success was high, with failure of initial management in 6.3%, and 30-day re-admission for recurrence in 2.1%. The adverse event rate (15.7% overall) did not vary by treatment modality or between periods 1& 2. CONCLUSION: The COVID-19 pandemic led to a significant change in the presentation and case mix of acute paediatric mastoiditis in the UK.


Assuntos
COVID-19/epidemiologia , Mastoidite/epidemiologia , Doença Aguda , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Masculino , Pandemias , Estudos Prospectivos , Estudos Retrospectivos , SARS-CoV-2 , Estações do Ano , Reino Unido/epidemiologia
11.
Eur Arch Otorhinolaryngol ; 278(11): 4225-4233, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33788034

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) is often used to visualize and diagnose soft tissues. Hearing implant (HI) recipients are likely to require at least one MRI scan during their lifetime. However, the MRI scanner can interact with the implant magnet, resulting in complications for the HI recipient. This survey, which was conducted in two phases, aimed to evaluate the safety and performance of MRI scans for individuals with a HI manufactured by MED-EL (MED-EL GmbH, Innsbruck, Austria). METHODS: A survey was developed and distributed in two phases to HEARRING clinics to obtain information about the use of MRI for recipients of MED-EL devices. Phase 1 focused on how often MRI is used in diagnostic imaging of the head region of the cochlear implant (CI) recipients. Phase 2 collected safety information about MRI scans performed on HI recipients. RESULTS: 106 of the 126 MRI scans reported in this survey were performed at a field strength of 1.5 T, on HI recipients who wore the SYNCHRONY CI or SYNCHRONY ABI. The head and spine were the most frequently imaged regions. 123 of the 126 scans were performed without any complications; two HI recipients experienced discomfort/pain. One recipient required reimplantation after an MRI was performed using a scanner that had not been approved for that implant. There was only one case that required surgical removal of the implant to reduce the imaging artefact. CONCLUSION: Individuals with either a SYNCHRONY CI or SYNCHRONY ABI from MED-EL can safely undergo a 1.5 T MRI when it is performed according to the manufacturer's safety policies and procedures.


Assuntos
Implante Coclear , Implantes Cocleares , Audição , Humanos , Imageamento por Ressonância Magnética , Imãs
12.
Int J Audiol ; 60(8): 561-577, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33426931

RESUMO

OBJECTIVE: Systematically review the current literature for evidence on the "real-life" benefits of hearing preservation cochlear implantation (HPCI) for children and adults. DESIGN: Systematic search of Pubmed, MEDLINE, EMBASE, CINHAL and Cochrane Library for MesH terms hearing¸ preservation and cochlear implantation. Inclusion criteria were the "real-life" benefit of HPCI i.e. other than pre- and post-operative pure tone thresholds. Exclusion criteria were non-English language, conference abstracts, reviews and animal and cadaveric studies. Risk of bias was assessed using the Evidence Project Tool. STUDY SAMPLE: 37 studies that matched criteria for review with 8/37 including children and 29/37 including adults. RESULTS: HPCI was associated with better speech perception in noise in 18/26 papers and better music perception in 4/5 papers. There was no significant benefit reported in speech perception in quiet (14/20 papers) or binaural cues (3/4 papers), nor was there convincing evidence of HPCI outperforming bimodal users (5/7 papers). QoL scores were high amongst HPCI patients (2/2 papers). Interpretation of findings was hindered by small study groups and significant heterogeneity in various parameters. CONCLUSION: Current literature on the "real-life" benefit of HPCI, although limited, supports the existence of meaningful benefit, especially in speech perception in noise and music perception.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Audição , Testes Auditivos , Humanos , Qualidade de Vida
13.
Clin Otolaryngol ; 46(3): 552-561, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33377276

RESUMO

OBJECTIVES: To assess the safety of paediatric tonsillectomy procedures conducted in NHS hospitals in England between 2008 and 2019. DESIGN: Retrospective observational cohort study using Hospital Episode Statistics (HES) data. SETTING: Acute NHS trusts in England conducting paediatric tonsillectomy procedures. PARTICIPANTS: Children (≤16 years old) undergoing bilateral tonsillectomy. MAIN OUTCOME MEASURES: Number of tonsillectomies performed per year by procedural method. In-hospital complications including return to theatre for arrest of haemorrhage. Readmission within 28 days, including those for pain, haemorrhage and surgical arrest of haemorrhage. Long-term outcomes: all-cause mortality, revision tonsillectomy. RESULTS: A total of 318 453 paediatric tonsillectomies were performed from 2008 to 2019:278,772 dissection (87.5%) and 39 681 coblation (12.5%). The proportion of tonsillectomy performed using coblation increased from 7% in 2008/9 to 27% in 2018/9. Five patients died in hospital (including 4 due to respiratory complications). In-hospital complications occurred in 4202 children (1.3%), with the most frequent being haemorrhage. Within 28 days of tonsillectomy, 28 170 patients (8.8%) were readmitted and 7 deaths occurred. Readmission rates for haemorrhage and pain have increased since 2008. The proportion of children undergoing revision tonsillectomy procedures within 5 years following coblation tonsillectomy (1.4%) was approximately double that of dissection (0.6%). CONCLUSIONS: Clinical practice of paediatric tonsillectomy has changed in England over the past 11 years. The overall mortality rate associated with the procedure is 0.0037%. Differences in outcomes have been identified for different procedural methods. However, routine administrative data are limited in differentiating procedural detail (eg we are unable to differentiate intra or extra-capsular techniques from current clinical coding of tonsillectomy procedures). Therefore, prospective national data collection or more granular clinical coding is essential to capture relative outcomes of the different tonsillectomy methods and techniques being used in the NHS.


Assuntos
Avaliação de Resultados em Cuidados de Saúde , Padrões de Prática Médica/estatística & dados numéricos , Tonsilectomia/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Inglaterra , Feminino , Humanos , Lactente , Masculino , Complicações Pós-Operatórias , Estudos Retrospectivos
14.
Ear Hear ; 41(3): 630-639, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31633599

RESUMO

OBJECTIVES: With the advent of newborn hearing screening and early intervention, there is a growing interest in using supra-threshold obligatory cortical auditory evoked potentials (CAEPs) to complement established pediatric clinical test procedures. The aim of this study was to assess the feasibility, and parent acceptability, of recording infant CAEPs. DESIGN: Typically developing infants (n = 104) who had passed newborn hearing screening and whose parents expressed no hearing concerns were recruited. Testing was not possible in 6 infants, leaving 98, age range 5 to 39 weeks (mean age = 21.9, SD = 9.4). Three short duration speech-like stimuli (/m/, /g/, /t/) were presented at 65 dB SPL via a loudspeaker at 0° azimuth. Three criteria were used to assess clinical feasibility: (i) median test duration <30 min, (ii) >90% completion rate in a single test session, and (iii) >90% response detection for each stimulus. We also recorded response amplitude, latency, and CAEP signal to noise ratio. Response amplitudes and residual noise levels were compared for Fpz (n = 56) and Cz (n = 42) noninverting electrode locations. Parental acceptability was based on an 8-item questionnaire (7-point scale, 1 being best). In addition, we explored the patient experience in semistructured telephone interviews with seven families. RESULTS: The median time taken to complete 2 runs for 3 stimuli, including preparation, was 27 min (range 17 to 59 min). Of the 104 infants, 98 (94%) were in an appropriate behavioral state for testing. A further 7 became restless during testing and their results were classified as "inconclusive." In the remaining 91 infants, CAEPs were detected in every case with normal bilateral tympanograms. Detection of CAEPs in response to /m/, /g/, and /t/ in these individuals was 86%, 100%, and 92%, respectively. Residual noise levels and CAEP amplitudes were higher for Cz electrode recordings. Mean scores on the acceptability questionnaire ranged from 1.1 to 2.6. Analysis of interviews indicated that parents found CAEP testing to be a positive experience and recognized the benefit of having an assessment procedure that uses conversational level speech stimuli. CONCLUSIONS: Test duration, completion rates, and response detection rates met (or were close to) our feasibility targets, and parent acceptability was high. CAEPs have the potential to supplement existing practice in 3- to 9-month olds.


Assuntos
Percepção da Fala , Estimulação Acústica , Criança , Potenciais Evocados Auditivos , Estudos de Viabilidade , Humanos , Lactente , Recém-Nascido , Pais , Fala
16.
Cleft Palate Craniofac J ; 56(2): 222-230, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29665338

RESUMO

OBJECTIVE: To identify outcomes relating to sleep-disordered breathing (SDB) that are relevant to parents, during the early weeks of caring for infants with cleft palate (CP), and compare these with clinical outcomes identified in a systematic search of research literature. DESIGN: A qualitative study using telephone/face-to-face interviews with parents explored their understanding of breathing and respiratory effort in infants with CP. SETTING: Care provided by 3 specialist cleft centers in the United Kingdom, with study conducted in parents' homes. PARTICIPANTS: Criteria for participation were parents of infants with isolated CP aged 12 to 16 weeks. Thirty-one parents of infants with CP (over 12 weeks) were invited to participate in the interview. Interviews were completed with 27 parents; 4 parents could not be contacted after completing the sleep monitoring. RESULTS: Parents' description of infants' sleep suggests that breathing is not considered as a separate priority from their principal concerns of feeding and sleeping. They observe indicators of infants' breathing, but these are not perceived as signs of SDB. Parents' decision to use lateral or supine sleep positioning reflects their response to advice from specialists, observation of their infants' comfort, ease of breathing, and personal experience. Outcomes, identified in published research of SDB, coincide with parents' concerns but are expressed in medical language and fit into distinct domains of "snoring," "sleep," "gas exchange," and "apnea." CONCLUSIONS: Parents' description of sleeping and respiration in infants with CP reflect their everyday experience, offering insight into their understanding, priorities, and language used to describe respiration. Understanding parents' individual priorities and how these are expressed could be fundamental to selecting meaningful outcomes for future studies of airway interventions.


Assuntos
Fissura Palatina , Síndromes da Apneia do Sono , Humanos , Lactente , Pais , Ronco , Reino Unido
17.
Clin Otolaryngol ; 44(1): 32-38, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30222906

RESUMO

OBJECTIVES: To scope current service provision across England for management of otitis media with effusion and hearing loss in children with Down syndrome; to explore professional decision-making about managing otitis media with effusion and hearing loss; and to explore patient and public views on the direction of future research. DESIGN: Mixed methods including a service evaluation of NHS clinical practice through a structured telephone survey; a qualitative study of professional decision-making with in-depth interviews collected and analysed using grounded theory methods; patient/public involvement consultations. PARTICIPANTS: Twenty-one audiology services in England took part in the evaluation; 10 professionals participated in the qualitative study; 21 family members, 10 adults with Down syndrome and representatives from two charities contributed to the consultations. RESULTS: There was variation across services in the frequency of routine hearing surveillance, approaches to managing conductive hearing loss in infancy and provision of hearing aids and grommets. There was variation in how professionals describe their decision-making, reflecting individual treatment preferences, differing approaches to professional remit and institutional factors. The consultations identified that research should focus on improving practical support for managing the condition and supporting decision-making about interventions. CONCLUSIONS: There is system-level variation in the provision of services and individual-level variation in how professionals make clinical decisions. As a consequence, there is inequity of access to hearing health care for children with Down syndrome. Future research should focus on developing core outcomes for research and care, and on improving decision support for families.


Assuntos
Síndrome de Down/complicações , Perda Auditiva/etiologia , Perda Auditiva/reabilitação , Otite Média com Derrame/complicações , Medicina Estatal/organização & administração , Criança , Inglaterra , Feminino , Humanos , Masculino , Pesquisa Qualitativa
18.
Neuroimage ; 183: 985-993, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30243955

RESUMO

In diffusion MRI (dMRI), static magnetic field (B0) inhomogeneity and time varying gradient eddy currents induce spatial distortions in reconstructed images. These distortions are exacerbated when high spatial resolutions are used, and many field-mapping based correction techniques often only acquire maps of static B0 distortion, which are not adequate for correcting eddy current induced image distortions. This report presents a novel technique, termed RPG-MUSE, for achieving distortion-free high-resolution diffusion MRI by integrating reversed polarity gradients (RPG) into the multi-shot echo planar imaging acquisition scheme used in multiplexed sensitivity encoding (MUSE). By alternating the phase encoding direction between shots in both baseline and diffusion-weighted acquisitions, maps of both static B0 and eddy current induced field inhomogeneities can be inherently derived, without the need for additional data acquisition. Through both 2D and 3D encoded dMRI acquisitions, it is shown that an RPG-MUSE reconstruction can simultaneously achieve high spatial resolution, high spatial fidelity, and subsequently, high accuracy in diffusion metrics.


Assuntos
Artefatos , Mapeamento Encefálico/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem Ecoplanar/métodos , Humanos
19.
Neuroimage ; 159: 46-56, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28732674

RESUMO

Recent advances in achieving ultrahigh spatial resolution (e.g. sub-millimeter) diffusion MRI (dMRI) data have proven highly beneficial in characterizing tissue microstructures in organs such as the brain. However, the routine acquisition of in-vivo dMRI data at such high spatial resolutions has been largely prohibited by factors that include prolonged acquisition times, motion induced artifacts, and low SNR. To overcome these limitations, we present here a framework for acquiring and reconstructing 3D multi-slab, multi-band and interleaved multi-shot EPI data, termed 3D-MB-MUSE. Through multi-band excitations, the simultaneous acquisition of multiple 3D slabs enables whole brain dMRI volumes to be acquired in-vivo on a 3 T clinical MRI scanner at high spatial resolution within a reasonably short amount of time. Representing a true 3D model, 3D-MB-MUSE reconstructs an entire 3D multi-band, multi-shot dMRI slab at once while simultaneously accounting for coil sensitivity variations across the slab as well as motion induced artifacts commonly associated with both 3D and multi-shot diffusion imaging. Such a reconstruction fully preserves the SNR advantages of both 3D and multi-shot acquisitions in high resolution dMRI images by removing both motion and aliasing artifacts across multiple dimensions. By enabling ultrahigh resolution dMRI for routine use, the 3D-MB-MUSE framework presented here may prove highly valuable in both clinical and research applications.


Assuntos
Encéfalo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neuroimagem/métodos , Algoritmos , Humanos
20.
Eur J Pediatr ; 176(5): 661-667, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28331972

RESUMO

Guidance recommends 'back to sleep' positioning for infants from birth in order to reduce the risk of sudden infant death. Exceptions have been made for babies with severe respiratory difficulties where lateral positioning may be recommended, although uncertainty exists for other conditions affecting the upper airway structures, such as cleft palate. This paper presents research of (i) current advice on sleep positioning provided to parents of infants with cleft palate in the UK; and (ii) decision making by clinical nurse specialists when advising parents of infants with cleft palate. A qualitative descriptive study used data from a national survey with clinical nurse specialists from 12 regional cleft centres in the UK to investigate current practice. Data were collected using semi-structured telephone interviews and analysed using content analysis. Over half the regional centres used lateral sleep positioning based on clinical judgement of the infants' respiratory effort and upper airway obstruction. Assessment relied upon clinical judgement augmented by a range of clinical indicators, such as measures of oxygen saturation, heart rate and respiration. CONCLUSION: Specialist practitioners face a clinical dilemma between adhering to standard 'back to sleep' guidance and responding to clinical assessment of respiratory effort for infants with cleft palate. In the absence of clear evidence, specialist centres rely on clinical judgement regarding respiratory problems to identify what they believe is the most appropriate sleeping position for infants with cleft palate. Further research is needed to determine the best sleep position for an infant with cleft palate. What is Known • Supine sleep positioning reduces the risk of sudden infant death in new born infants. • There is uncertainty about the benefits or risks of lateral sleep positioning for infants with upper airway restrictions arising from cleft palate. What is New • Variability exists in the information/advice provided to parents of infants with cleft palate regarding sleep positioning. • Over half the national specialist centres for cleft palate in the UK advise positioning infants with CP in the lateral position as a routine measure to reduce difficulties with respiration.


Assuntos
Fissura Palatina , Guias de Prática Clínica como Assunto , Sono/fisiologia , Morte Súbita do Lactente/prevenção & controle , Decúbito Dorsal/fisiologia , Humanos , Lactente , Cuidado do Lactente/métodos , Enfermeiros Clínicos , Decúbito Ventral/fisiologia , Pesquisa Qualitativa , Fatores de Risco , Morte Súbita do Lactente/etiologia , Inquéritos e Questionários , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA