Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
J Artif Organs ; 18(2): 166-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25549810

RESUMO

Multiple implantations of left ventricular assist devices over a period of three years were performed in a 17-year-old gentleman with non-ischaemic dilated cardiomyopathy and congestive cardiac failure. The first device (HeartMate II) was implanted as a bridge to transplantation. However, after few months of support the patient showed signs of myocardial recovery and the device was successfully explanted. After 2 years of uneventful follow-up, the patient's condition deteriorated requiring further mechanical support. Due to the elevated risk associated with a redo full-support LVAD implantation, we decided to implant a partial support device (Synergy CircuLite). Because of recurrent pump thrombosis requiring device exchange, the final weeks to transplantation were bridged with CentriMag short-term LVAD. After successful cardiac transplantation the patient required further temporary extracorporeal membrane oxygenation support which was weaned off and explanted on the fourth postoperative day. After further uncomplicated postoperative recovery the patient was discharged and has been doing well for 1 year of follow-up.


Assuntos
Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Adolescente , Oxigenação por Membrana Extracorpórea , Transplante de Coração , Humanos , Masculino , Reoperação
2.
J Artif Organs ; 17(4): 370-2, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25103222

RESUMO

In this case report, we describe a 66-year-old patient with a massive LV aneurism which resulted after myocardial infarction. Due to severe LV function impairment, it was decided to perform left ventricular reconstruction surgery and, at the same time, left ventricular assist device implantation as a bridge to transplantation. The entire procedure was completed without using any patch material. The patient had an uneventful recovery and was discharged home after 18 days. After 1-year follow-up no adverse events were observed.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Procedimentos de Cirurgia Plástica/métodos , Idoso , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA