Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Anal Chem ; 91(22): 14407-14416, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31638379

RESUMO

A challenge facing metabolomics in the analysis of large human cohorts is the cross-laboratory comparability of quantitative metabolomics measurements. In this study, 14 laboratories analyzed various blood specimens using a common experimental protocol provided with the Biocrates AbsoluteIDQ p400HR kit, to quantify up to 408 metabolites. The specimens included human plasma and serum from male and female donors, mouse and rat plasma, as well as NIST SRM 1950 reference plasma. The metabolite classes covered range from polar (e.g., amino acids and biogenic amines) to nonpolar (e.g., diacyl- and triacyl-glycerols), and they span 11 common metabolite classes. The manuscript describes a strict system suitability testing (SST) criteria used to evaluate each laboratory's readiness to perform the assay, and provides the SST Skyline documents for public dissemination. The study found approximately 250 metabolites were routinely quantified in the sample types tested, using Orbitrap instruments. Interlaboratory variance for the NIST SRM-1950 has a median of 10% for amino acids, 24% for biogenic amines, 38% for acylcarnitines, 25% for glycerolipids, 23% for glycerophospholipids, 16% for cholesteryl esters, 15% for sphingolipids, and 9% for hexoses. Comparing to consensus values for NIST SRM-1950, nearly 80% of comparable analytes demonstrated bias of <50% from the reference value. The findings of this study result in recommendations of best practices for system suitability, quality control, and calibration. We demonstrate that with appropriate controls, high-resolution metabolomics can provide accurate results with good precision across laboratories, and the p400HR therefore is a reliable approach for generating consistent and comparable metabolomics data.


Assuntos
Aminoácidos/sangue , Aminas Biogênicas/sangue , Análise Química do Sangue/estatística & dados numéricos , Lipidômica/estatística & dados numéricos , Lipídeos/sangue , Metabolômica/estatística & dados numéricos , Análise de Variância , Animais , Cromatografia Líquida de Alta Pressão/estatística & dados numéricos , Agregação de Dados , Feminino , Humanos , Limite de Detecção , Masculino , Espectrometria de Massas/estatística & dados numéricos , Metaboloma , Camundongos , Ratos , Reprodutibilidade dos Testes
2.
Nat Methods ; 12(8): 725-31, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26121405

RESUMO

Antibodies are used in multiple cell biology applications, but there are no standardized methods to assess antibody quality-an absence that risks data integrity and reproducibility. We describe a mass spectrometry-based standard operating procedure for scoring immunoprecipitation antibody quality. We quantified the abundance of all the proteins in immunoprecipitates of 1,124 new recombinant antibodies for 152 chromatin-related human proteins by comparing normalized spectral abundance factors from the target antigen with those of all other proteins. We validated the performance of the standard operating procedure in blinded studies in five independent laboratories. Antibodies for which the target antigen or a member of its known protein complex was the most abundant protein were classified as 'IP gold standard'. This method generates quantitative outputs that can be stored and archived in public databases, and it represents a step toward a platform for community benchmarking of antibody quality.


Assuntos
Anticorpos Monoclonais/química , Especificidade de Anticorpos , Cromatina/química , Imunoprecipitação/métodos , Proteômica/métodos , Clonagem Molecular , Biologia Computacional/métodos , Escherichia coli/metabolismo , Células HEK293 , Humanos , Fragmentos de Imunoglobulinas/química , Imunoglobulina G/química , Espectrometria de Massas/métodos , Biblioteca de Peptídeos , Proteínas/química , Proteoma , Reprodutibilidade dos Testes
3.
Methods ; 81: 66-73, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25770357

RESUMO

Proprotein convertase subtilisin/kexin type 9 (PCSK9) is a key regulator of circulating low density lipoprotein cholesterol (LDL-C) levels. Besides its full-length mature form, multiple variants of PCSK9 have been reported such as forms that are truncated, mutated and/or with posttranslational modifications (PTMs). Previous studies have demonstrated that most of these variants affect PCSK9's function and thereby LDL-C levels. Commercial ELISA kits are available for quantification of PCSK9, but do not allow discrimination between the various forms and PTMs of the protein. To address this issue and given the complexity and wide dynamic range of the plasma proteome, we have developed a mass spectrometric immunoassay coupled to selected reaction monitoring (MSIA-SRM) for the multiplexed quantification of several forms of circulating PCSK9 in human plasma. Our MSIA-SRM assay quantifies peptides spanning the various protein domains and the S688 phosphorylation site. The assay was applied in two distinct cohorts of obese patients and healthy pregnant women stratified by their circulating LDL-C levels. Seven PCSK9 peptides were monitored in plasma samples: one in the prodomain prior to the autocleavage site at Q152, one in the catalytic domain prior to the furin cleavage site at R218, two in the catalytic domain following R218, one in the cysteine and histidine rich domain (CHRD) and the C-terminal peptide phosphorylated at S688 and unmodified. The latter was not detectable in sufficient amounts to be quantified in human plasma. All peptides were measured with high reproducibility and with LLOQ and LOD below the clinical range. The abundance of 5 of the 6 detectable PCSK9 peptides was higher in obese patients stratified with high circulating LDL-C levels as compared to those with low LDL-C (p < 0.05). The same 5 peptides showed good and statistically significant correlations with LDL-C levels (0.55 < r < 0.65; 0.0002 ⩽ p ⩽ 0.002), but not the S688 phosphorylated peptide. However, this phosphopeptide was significantly correlated with insulin resistance (r = 0.48; p = 0.04). In the pregnant women cohort, none of the peptides were associated to LDL-C levels. However, the 6 detectable PCSK9 peptides, but not PCSK9 measured by ELISA, were significantly correlated with serum triglyceride levels in this cohort. Our results also suggest that PCSK9 circulates with S688 phosphorylated at high stoichiometry. In summary, we have developed and applied a robust and sensitive MSIA-SRM assay for the absolute quantification of all PCSK9 domains and a PTM in human plasma. This assay revealed novel relationships between PCSK9 and metabolic phenotypes, as compared to classical ELISA assays.


Assuntos
Imunoensaio/métodos , Espectrometria de Massas/métodos , Pró-Proteína Convertases/sangue , Serina Endopeptidases/sangue , Adolescente , Adulto , Feminino , Humanos , Resistência à Insulina , Lipoproteínas LDL/sangue , Masculino , Pessoa de Meia-Idade , Obesidade/sangue , Fenótipo , Gravidez , Pró-Proteína Convertase 9 , Pró-Proteína Convertases/metabolismo , Processamento de Proteína Pós-Traducional , Proteólise , Serina Endopeptidases/metabolismo , Triglicerídeos/sangue , Adulto Jovem
4.
Clin Proteomics ; 12(1): 2, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25678897

RESUMO

BACKGROUND: The anatomy of PFO suggests that it can allow thrombi and potentially harmful circulatory factors to travel directly from the venous to the arterial circulation - altering circulatory phenotype. Our previous publication using high-resolution LC-MS/MS to profile protein and peptide expression patterns in plasma showed that albumin was relatively increased in donor samples from PFO-related than other types of ischemic strokes. Since albumin binds a host of molecules and acts as a carrier for lipoproteins, small molecules and drugs, we decided to investigate the albumin-bound proteins (in a similar sample cohort) in an effort to unravel biological changes and potentially discover biomarkers related to PFO-related stroke and PFO endovascular closure. METHODS: The method used in this study combined albumin immuno-enrichment with high resolution LC-MS in order to specifically capture and quantify the albumin-bound proteins. Subsequently, we measured cholesterol and HDL in a larger, separate cohort of PFO stroke patients, pre and post closure. RESULTS: The results demonstrated that a number of proteins were specifically associated with albumin in samples with and without endovascular closure of the PFO, and that the protein profiles were very different. Eight proteins, typically associated with HDL were common to both sample sets and quantitatively differently abundant. Pathway analysis of the MS results suggested that enhanced cholesterol efflux and reduced lipid oxidation were associated with PFO closure. Measurement of total cholesterol and HDL in a larger cohort of PFO closure samples using a colorimetric assay was consistent with the proteomic predictions. CONCLUSIONS: The collective data presented in this study demonstrate that analysis of albumin-bound proteins could provide a valuable tool for biomarker discovery on the effects of PFO endovascular closure. In addition, the results suggest that PFO endovascular closure can potentially have effects on HDL, cholesterol and albumin-bound ApoA-I abundance, therefore possibly providing benefits in cardioprotective functions.

5.
Proteomics ; 14(12): 1445-56, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24668948

RESUMO

The detection and quantification of insulin and its therapeutic analogs is important for medical, sports doping, and forensic applications. Synthetic variants contain slight sequence variations to affect bioavailability. To reduce sample handling bias, a universal extraction method is required for simultaneous extraction of endogenous and variant insulins with subsequent targeted quantification by LC-MS. A mass spectrometric immunoassay (MSIA), a multiplexed assay for intact insulin and its analogues that couples immunoenrichment with high resolution and accurate mass (HR/AM) spectrometric detection across the clinical range is presented in this report. The assay is sensitive, selective, semi-automated and can potentially be applied to detect new insulin isoforms allowing their further incorporation into second or third generation assays.


Assuntos
Cromatografia Líquida/métodos , Ensaios de Triagem em Larga Escala , Imunoensaio/métodos , Insulina/análogos & derivados , Insulina/sangue , Proteômica , Espectrometria de Massas em Tandem/métodos , Humanos , Isoformas de Proteínas
6.
J Proteome Res ; 13(12): 5415-30, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25244318

RESUMO

Data-dependent acquisition (DDA) and data-independent acquisition strategies (DIA) have both resulted in improved understanding of proteomics samples. Both strategies have advantages and disadvantages that are well-published, where DDA is typically applied for deep discovery and DIA may be used to create sample records. In this paper, we present a hybrid data acquisition and processing strategy (pSMART) that combines the strengths of both techniques and provides significant benefits for qualitative and quantitative peptide analysis. The performance of pSMART is compared to published DIA strategies in an experiment that allows the objective assessment of DIA performance with respect to interrogation of previously acquired MS data. The results of this experiment demonstrate that pSMART creates fewer decoy hits than a standard DIA strategy. Moreover, we show that pSMART is more selective, sensitive, and reproducible than either standard DIA or DDA strategies alone.


Assuntos
Processamento Eletrônico de Dados/métodos , Peptídeos/análise , Proteoma/análise , Proteômica/métodos , Sequência de Aminoácidos , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Dados de Sequência Molecular , Peptídeos/metabolismo , Proteoma/metabolismo , Reprodutibilidade dos Testes , Software
7.
Hepatol Commun ; 4(8): 1168-1182, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32766476

RESUMO

Alcohol-related liver disease is a major public health burden, and the gut microbiota is an important contributor to disease pathogenesis. The aim of the present study is to characterize functional alterations of the gut microbiota and test their performance for short-term mortality prediction in patients with alcoholic hepatitis. We integrated shotgun metagenomics with untargeted metabolomics to investigate functional alterations of the gut microbiota and host co-metabolism in a multicenter cohort of patients with alcoholic hepatitis. Profound changes were found in the gut microbial composition, functional metagenome, serum, and fecal metabolomes in patients with alcoholic hepatitis compared with nonalcoholic controls. We demonstrate that in comparison with single omics alone, the performance to predict 30-day mortality was improved when combining microbial pathways with respective serum metabolites in patients with alcoholic hepatitis. The area under the receiver operating curve was higher than 0.85 for the tryptophan, isoleucine, and methionine pathways as predictors for 30-day mortality, but achieved 0.989 for using the urea cycle pathway in combination with serum urea, with a bias-corrected prediction error of 0.083 when using leave-one-out cross validation. Conclusion: Our study reveals changes in key microbial metabolic pathways associated with disease severity that predict short-term mortality in our cohort of patients with alcoholic hepatitis.

8.
Metabolites ; 9(5)2019 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-31121816

RESUMO

Mouse knockouts facilitate the study ofgene functions. Often, multiple abnormal phenotypes are induced when a gene is inactivated. The International Mouse Phenotyping Consortium (IMPC) has generated thousands of mouse knockouts and catalogued their phenotype data. We have acquired metabolomics data from 220 plasma samples from 30 unique mouse gene knockouts and corresponding wildtype mice from the IMPC. To acquire comprehensive metabolomics data, we have used liquid chromatography (LC) combined with mass spectrometry (MS) for detecting polar and lipophilic compounds in an untargeted approach. We have also used targeted methods to measure bile acids, steroids and oxylipins. In addition, we have used gas chromatography GC-TOFMS for measuring primary metabolites. The metabolomics dataset reports 832 unique structurally identified metabolites from 124 chemical classes as determined by ChemRICH software. The GCMS and LCMS raw data files, intermediate and finalized data matrices, R-Scripts, annotation databases, and extracted ion chromatograms are provided in this data descriptor. The dataset can be used for subsequent studies to link genetic variants with molecular mechanisms and phenotypes.

9.
Clin Biochem ; 46(6): 399-410, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23313081

RESUMO

OBJECTIVES: The aim of this study was to develop high-throughput, quantitative and highly selective mass spectrometric, targeted immunoassays for clinically important proteins in human plasma or serum. DESIGN AND METHODS: The described method coupled mass spectrometric immunoassay (MSIA), a previously developed technique for immunoenrichment on a monolithic microcolumn activated with an anti-protein antibody and fixed in a pipette tip, to selected reaction monitoring (SRM) detection and accurate quantification of targeted peptides, including clinically relevant sequence or truncated variants. RESULTS: In this report, we demonstrate the rapid development of MSIA-SRM assays for sixteen different target proteins spanning seven different clinically important areas (including neurological, Alzheimer's, cardiovascular, endocrine function, cancer and other diseases) and ranging in concentration from pg/mL to mg/mL. The reported MSIA-SRM assays demonstrated high sensitivity (within published clinical ranges), precision, robustness and high-throughput as well as specific detection of clinically relevant isoforms for many of the target proteins. Most of the assays were tested with bona-fide clinical samples. In addition, positive correlations, (R2 0.67-0.87, depending on the target peptide), were demonstrated for MSIA-SRM assay data with clinical analyzer measurements of parathyroid hormone (PTH) and insulin growth factor 1 (IGF1) in clinical sample cohorts. CONCLUSIONS: We have presented a practical and scalable method for rapid development and deployment of MS-based SRM assays for clinically relevant proteins and measured levels of the target analytes in bona fide clinical samples. The method permits the specific quantification of individual protein isoforms and addresses the difficult problem of protein heterogeneity in clinical proteomics applications.


Assuntos
Proteínas Sanguíneas/isolamento & purificação , Ensaios de Triagem em Larga Escala , Imunoensaio/métodos , Espectrometria de Massas/métodos , Doença de Alzheimer/sangue , Doenças Cardiovasculares/sangue , Transtornos do Crescimento/sangue , Humanos , Neoplasias/sangue , Insuficiência Renal/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA