Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Diabetes Technol Ther ; 19(1): 18-24, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27982707

RESUMO

BACKGROUND: In the past few years, the artificial pancreas-the commonly accepted term for closed-loop control (CLC) of blood glucose in diabetes-has become a hot topic in research and technology development. In the summer of 2014, we initiated a 6-month trial evaluating the safety of 24/7 CLC during free-living conditions. RESEARCH DESIGN AND METHODS: Following an initial 1-month Phase 1, 14 individuals (10 males/4 females) with type 1 diabetes at three clinical centers in the United States and one in Italy continued with a 5-month Phase 2, which included 24/7 CLC using the wireless portable Diabetes Assistant (DiAs) developed at the University of Virginia Center for Diabetes Technology. Median subject characteristics were age 45 years, duration of diabetes 27 years, total daily insulin 0.53 U/kg/day, and baseline HbA1c 7.2% (55 mmol/mol). RESULTS: Compared with the baseline observation period, the frequency of hypoglycemia below 3.9 mmol/L during the last 3 months of CLC was lower: 4.1% versus 1.3%, P < 0.001. This was accompanied by a downward trend in HbA1c from 7.2% (55 mmol/mol) to 7.0% (53 mmol/mol) at 6 months. HbA1c improvement was correlated with system use (Spearman r = 0.55). The user experience was favorable with identified benefit particularly at night and overall trust in the system. There were no serious adverse events, severe hypoglycemia, or diabetic ketoacidosis. CONCLUSION: We conclude that CLC technology has matured and is safe for prolonged use in patients' natural environment. Based on these promising results, a large randomized trial is warranted to assess long-term CLC efficacy and safety.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adulto , Diabetes Mellitus Tipo 1/sangue , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Pâncreas Artificial
2.
Diabetes Care ; 39(7): 1151-60, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27208331

RESUMO

OBJECTIVE: After testing of a wearable artificial pancreas (AP) during evening and night (E/N-AP) under free-living conditions in patients with type 1 diabetes (T1D), we investigated AP during day and night (D/N-AP) for 1 month. RESEARCH DESIGN AND METHODS: Twenty adult patients with T1D who completed a previous randomized crossover study comparing 2-month E/N-AP versus 2-month sensor augmented pump (SAP) volunteered for 1-month D/N-AP nonrandomized extension. AP was executed by a model predictive control algorithm run by a modified smartphone wirelessly connected to a continuous glucose monitor (CGM) and insulin pump. CGM data were analyzed by intention-to-treat with percentage time-in-target (3.9-10 mmol/L) over 24 h as the primary end point. RESULTS: Time-in-target (mean ± SD, %) was similar over 24 h with D/N-AP versus E/N-AP: 64.7 ± 7.6 vs. 63.6 ± 9.9 (P = 0.79), and both were higher than with SAP: 59.7 ± 9.6 (P = 0.01 and P = 0.06, respectively). Time below 3.9 mmol/L was similarly and significantly reduced by D/N-AP and E/N-AP versus SAP (both P < 0.001). SD of blood glucose concentration (mmol/L) was lower with D/N-AP versus E/N-AP during whole daytime: 3.2 ± 0.6 vs. 3.4 ± 0.7 (P = 0.003), morning: 2.7 ± 0.5 vs. 3.1 ± 0.5 (P = 0.02), and afternoon: 3.3 ± 0.6 vs. 3.5 ± 0.8 (P = 0.07), and was lower with D/N-AP versus SAP over 24 h: 3.1 ± 0.5 vs. 3.3 ± 0.6 (P = 0.049). Insulin delivery (IU) over 24 h was higher with D/N-AP and SAP than with E/N-AP: 40.6 ± 15.5 and 42.3 ± 15.5 vs. 36.6 ± 11.6 (P = 0.03 and P = 0.0004, respectively). CONCLUSIONS: D/N-AP and E/N-AP both achieved better glucose control than SAP under free-living conditions. Although time in the different glycemic ranges was similar between D/N-AP and E/N-AP, D/N-AP further reduces glucose variability.


Assuntos
Glicemia/análise , Ritmo Circadiano/fisiologia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Adulto , Algoritmos , Glicemia/efeitos dos fármacos , Automonitorização da Glicemia/métodos , Estudos Cross-Over , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Condições Sociais , Adulto Jovem
3.
Diabetes Care ; 39(7): 1180-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27208335

RESUMO

OBJECTIVE: The Pediatric Artificial Pancreas (PedArPan) project tested a children-specific version of the modular model predictive control (MMPC) algorithm in 5- to 9-year-old children during a camp. RESEARCH DESIGN AND METHODS: A total of 30 children, 5- to 9-years old, with type 1 diabetes completed an outpatient, open-label, randomized, crossover trial. Three days with an artificial pancreas (AP) were compared with three days of parent-managed sensor-augmented pump (SAP). RESULTS: Overnight time-in-hypoglycemia was reduced with the AP versus SAP, median (25(th)-75(th) percentiles): 0.0% (0.0-2.2) vs. 2.2% (0.0-12.3) (P = 0.002), without a significant change of time-in-target, mean: 56.0% (SD 22.5) vs. 59.7% (21.2) (P = 0.430), but with increased mean glucose 173 mg/dL (36) vs. 150 mg/dL (39) (P = 0.002). Overall, the AP granted a threefold reduction of time-in-hypoglycemia (P < 0.001) at the cost of decreased time-in-target, 56.8% (13.5) vs. 63.1% (11.0) (P = 0.022) and increased mean glucose 169 mg/dL (23) vs. 147 mg/dL (23) (P < 0.001). CONCLUSIONS: This trial, the first outpatient single-hormone AP trial in a population of this age, shows feasibility and safety of MMPC in young children. Algorithm retuning will be performed to improve efficacy.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Pâncreas Artificial , Algoritmos , Glicemia/análise , Criança , Pré-Escolar , Estudos Cross-Over , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Sistemas de Infusão de Insulina , Masculino
4.
Diabetes Care ; 39(12): 2158-2164, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27852685

RESUMO

OBJECTIVE: To explore the experiences of children with type 1 diabetes and their parents taking part in an artificial pancreas (AP) clinical trial during a 7-day summer camp. RESEARCH DESIGN AND METHODS: A semistructured interview, composed of 14 questions based on the Technology Acceptance Model, was conducted at the end of the clinical trial. Participants also completed the Diabetes Treatment Satisfaction Questionnaire (DTSQ, parent version) and the AP Acceptance Questionnaire. RESULTS: Thirty children, aged 5-9 years, and their parents completed the study. A content analysis of the interviews showed that parents were focused on understanding the mechanisms, risks, and benefits of the new device, whereas the children were focused on the novelty of the new system. The parents' main concerns about adopting the new system seemed related to the quality of glucose control. The mean scores of DTSQ subscales indicated general parents' satisfaction (44.24 ± 5.99, range 32-53) and trustful views of diabetes control provided by the new system (7.8 ± 2.2, range 3-12). The AP Acceptance Questionnaire revealed that most parents considered the AP easy to use (70.5%), intended to use it long term (94.0%), and felt that it was apt to improve glucose control (67.0%). CONCLUSIONS: Participants manifested a positive attitude toward the AP. Further studies are required to explore participants' perceptions early in the AP development to individualize the new treatment as much as possible, and to tailor it to respond to their needs and values.


Assuntos
Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/terapia , Pâncreas Artificial/psicologia , Pais/psicologia , Adulto , Acampamento , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Humanos , Masculino , Relações Pais-Filho , Aceitação pelo Paciente de Cuidados de Saúde , Percepção , Inquéritos e Questionários
5.
Diabetes Care ; 39(7): 1143-50, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27208316

RESUMO

OBJECTIVE: To evaluate the efficacy of a portable, wearable, wireless artificial pancreas system (the Diabetes Assistant [DiAs] running the Unified Safety System) on glucose control at home in overnight-only and 24/7 closed-loop control (CLC) modes in patients with type 1 diabetes. RESEARCH DESIGN AND METHODS: At six clinical centers in four countries, 30 participants 18-66 years old with type 1 diabetes (43% female, 96% non-Hispanic white, median type 1 diabetes duration 19 years, median A1C 7.3%) completed the study. The protocol included a 2-week baseline sensor-augmented pump (SAP) period followed by 2 weeks of overnight-only CLC and 2 weeks of 24/7 CLC at home. Glucose control during CLC was compared with the baseline SAP. RESULTS: Glycemic control parameters for overnight-only CLC were improved during the nighttime period compared with baseline for hypoglycemia (time <70 mg/dL, primary end point median 1.1% vs. 3.0%; P < 0.001), time in target (70-180 mg/dL: 75% vs. 61%; P < 0.001), and glucose variability (coefficient of variation: 30% vs. 36%; P < 0.001). Similar improvements for day/night combined were observed with 24/7 CLC compared with baseline: 1.7% vs. 4.1%, P < 0.001; 73% vs. 65%, P < 0.001; and 34% vs. 38%, P < 0.001, respectively. CONCLUSIONS: CLC running on a smartphone (DiAs) in the home environment was safe and effective. Overnight-only CLC reduced hypoglycemia and increased time in range overnight and increased time in range during the day; 24/7 CLC reduced hypoglycemia and increased time in range both overnight and during the day. Compared with overnight-only CLC, 24/7 CLC provided additional hypoglycemia protection during the day.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Smartphone , Adolescente , Adulto , Idoso , Glicemia/efeitos dos fármacos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Feminino , Humanos , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Pâncreas Artificial/efeitos adversos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA