1.
Analyst ; 149(3): 968-974, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38197474

RESUMO

DNA nanotechnology deals with the design of non-naturally occurring DNA nanostructures that can be used in biotechnology, medicine, and diagnostics. In this study, we introduced a nucleic acid five-way junction (5WJ) structure for direct electrochemical analysis of full-length biological RNAs. To the best of our knowledge, this is the first report on the interrogation of such long nucleic acid sequences by hybridization probes attached to a solid support. A hairpin-shaped electrode-bound oligonucleotide hybridizes with three adaptor strands, one of which is labeled with methylene blue (MB). The four strands are combined into a 5WJ structure only in the presence of specific DNA or RNA analytes. Upon interrogation of a full-size 16S rRNA in the total RNA sample, the electrode-bound MB-labeled 5WJ association produces a higher signal-to-noise ratio than electrochemical nucleic acid biosensors of alternative design. This advantage was attributed to the favorable geometry on the 5WJ nanostructure formed on the electrode's surface. The 5WJ biosensor is a cost-efficient alternative to the traditional electrochemical biosensors for the analysis of nucleic acids due to the universal nature of both the electrode-bound and MB-labeled DNA components.


Assuntos
Técnicas Biossensoriais , Ácidos Nucleicos , RNA Ribossômico 16S , DNA/química , Sondas de DNA/química , Nanotecnologia , Técnicas Eletroquímicas , Hibridização de Ácido Nucleico , Azul de Metileno/química
2.
Anal Chem ; 93(3): 1271-1276, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33372767

RESUMO

Calibration of ion-selective electrodes (ISEs) is cumbersome, time-consuming, and constitutes a significant limitation for the development of single-use and wearable disposable sensors. To address this problem, we have studied the effect of ion-selective membrane solvent on ISE reproducibility by comparing tetrahydrofuran (THF) (a typical solvent for membrane preparation) and cyclohexanone. In addition, a single-step integration of semiconducting/transducer polymer poly(3-octylthiophene) (POT) with single-walled carbon nanotubes (SWCNTs) into the paper-based ISEs (PBISEs) substrate was introduced. PBISEs for potassium and sodium ions were developed, and these ISEs present outstanding sensor performance and high potential reproducibility, as low as ±1.0 mV (n = 3).

3.
Anal Chem ; 91(21): 13458-13464, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31571484

RESUMO

The recent outbreak of the Zika virus (ZIKV) in the Americas and multiple studies that linked the virus to the cases of microcephaly and neurological complications have revealed the need for cost efficient and rapid ZIKV diagnostics tests. Here, a diagnostic platform relying on a four-way junction (4WJ)-based biosensor with electrochemical readout using a Universal DNA-Hairpin (UDH) probe for the selective recognition of an isothermally amplified ZIKV RNA fragment is developed. The 4WJ structure utilizes an electrode-immobilized stem-loop (DNA-hairpin) probe and two DNA adaptor strands complementary to both the stem-loop probe and the targeted fragment of a ZIKV amplicon. One of the adaptor strands is responsible for high selectivity of the target recognition, while another helps unwinding the target secondary structure. The first adaptor strand contains a redox label methylene blue to trigger the current change in response to the target-dependent formation of the 4WJ structure on the surface of the electrode. The amplicon can be analyzed directly from the amplification sample without the need for its purification. The proposed diagnostic methodology exhibits the limit of ZIKV RNA detection of 1.11 fg/µL (∼0.3 fM) and high selectivity that allows for reliable discrimination of ZIKV from West Nile virus and four dengue virus serotypes. Overall, the analysis of ZIKV RNA can be completed in less than 1 h, including amplification and electrochemical detection.


Assuntos
Técnicas Biossensoriais/métodos , Sondas de DNA , RNA Viral/isolamento & purificação , Zika virus/isolamento & purificação , Técnicas Eletroquímicas , Sequências Repetidas Invertidas , Fatores de Tempo
4.
Anal Chem ; 88(17): 8404-8, 2016 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-27523089

RESUMO

Preparation of ion-selective electrodes (ISEs) often requires long and complicated conditioning protocols limiting their application as tools for in-field measurements. Herein, we eliminated the need for electrode conditioning by loading the membrane cocktail directly with primary ion solution. This proof of concept experiment was performed with iodide, silver, and sodium selective electrodes. The proposed methodology significantly shortened the preparation time of ISEs, yielding functional electrodes with submicromolar detection limits. Moreover, it is anticipated that this approach may form the basis for the development of miniaturized all-solid-state ion-selective electrodes for in situ measurements.

5.
Anal Chem ; 86(15): 7269-73, 2014 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-25023061

RESUMO

Paper-based ion-selective electrodes (ISEs) are simple, flexible, and cost-efficient in comparison to conventional solid-contact ISEs. Yet, paper-based ISEs have poor limits of detection (in the micromolar range) relative to conventional solid-contact ISEs. Here we describe the construction and optimization of ISEs based on commercially available filter paper modified with single-walled carbon nanotubes (SWCNTs), sputtered gold, and conductive polymer poly(3-octylthiophene) to support an ion-selective membrane. The ion-selective membrane presented here is based on the copolymer methyl methacrylate-decyl methacrylate (MMA-DMA). The copolymer MMA-DMA is highly water-repellent and has a low coefficient of diffusion, which makes it particularly suitable for the creation of sensors with high performance in reaching low limits of detection. Three different configurations of the electrodes have been characterized by using contact angle surface analysis, oxygen influence, and testing for the presence of a water layer. Paper-strip ISEs for cadmium, silver, and potassium ions were developed with groundbreaking limits of detection of 1.2, 25.1, and 11.0 nM, respectively. In addition to such low limits of detection, paper-strip ISEs display high selectivity for their ion of interest and high reproducibility.


Assuntos
Cádmio/análise , Eletrodos Seletivos de Íons , Potássio/análise , Prata/análise , Limite de Detecção , Papel
6.
Anal Chem ; 86(13): 6184-7, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24893213

RESUMO

Presented here is a sensing membrane consisting of a modified merocyanine photoacid polymer and a calcium ionophore in plasticized poly(vinyl chloride). This membrane is shown to actively exchange protons with calcium ions when switched ON after illumination at 470 nm, and the exchange can be followed by UV-vis spectroscopy. The sensing membrane shows no response in the ON state when calcium ions are absent. The limit of detection of the sensor is 5.0 × 10(-4) M with an upper detection limit of 1.0 M. Thus, we demonstrate for the first time the use of a visible light activated, lipophilic photoacid polymer in an ion-sensing membrane for calcium ions, which highly discriminates potassium, sodium, and magnesium ions.

7.
Biosensors (Basel) ; 13(9)2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37754108

RESUMO

A modular, multi-purpose, and cost-effective electrochemical biosensor based on a five-stranded four-way junction (5S-4WJ) system was developed for SARS-CoV-2 (genes S and N) and Influenza A virus (gene M) detection. The 5S-4WJ structure consists of an electrode-immobilized universal stem-loop (USL) strand, two auxiliary DNA strands, and a universal methylene blue redox strand (UMeB). This design allows for the detection of specific nucleic acid sequences using square wave voltammetry (SWV). The sequence-specific auxiliary DNA strands (m and f) ensure selectivity of the biosensor for target recognition utilizing the same USL and UMeB components. An important feature of this biosensor is the ability to reuse the USL-modified electrodes to detect the same or alternative targets in new samples. This is accomplished by a simple procedure involving rinsing the electrodes with water to disrupt the 5S-4WJ structure and subsequent re-hybridization of the USL strand with the appropriate set of strands for a new analysis. The biosensor exhibited minimal loss in signal after rehybridization, demonstrating its potential as a viable multiplex assay for both current and future pathogens, with a low limit of quantification (LOQ) of as low as 17 pM.


Assuntos
COVID-19 , Influenza Humana , Humanos , SARS-CoV-2 , Análise Custo-Benefício , Influenza Humana/diagnóstico , Eletrodos
8.
Plant J ; 63(6): 1004-16, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20626658

RESUMO

Indole-3-acetic acid (IAA) is a primary phytohormone that regulates multiple aspects of plant development. Because polar transport of IAA is an essential determinant of organogenesis and dynamic tropic growth, methods to monitor IAA movement in vivo are in demand. A self-referencing electrochemical microsensor was optimized to non-invasively measure endogenous IAA flux near the surface of Zea mays roots without the addition of exogenous IAA. Enhanced sensor surface modification, decoupling of acquired signals, and integrated flux analyses were combined to provide direct, real time quantification of endogenous IAA movement in B73 maize inbred and brachytic2 (br2) auxin transport mutant roots. BR2 is localized in epidermal and hypodermal tissues at the root apex. br2 roots exhibit reduced shootward IAA transport at the root apex in radiotracer experiments and reduced gravitropic growth. IAA flux data indicates that maximal transport occurs in the distal elongation zone of maize roots, and net transport in/out of br2 roots was decreased compared to B73. Integration of short term real time flux data in this zone revealed oscillatory patterns, with B73 exhibiting shorter oscillatory periods and greater amplitude than br2. IAA efflux and influx were inhibited using 1-N-naphthylphthalamic acid (NPA), and 2-naphthoxyacetic acid (NOA), respectively. A simple harmonic oscillation model of these data produced a correlation between modeled and measured values of 0.70 for B73 and 0.69 for br2. These results indicate that this technique is useful for real-time IAA transport monitoring in surface tissues and that this approach can be performed simultaneously with current live imaging techniques.


Assuntos
Técnicas Biossensoriais/métodos , Ácidos Indolacéticos/metabolismo , Raízes de Plantas/metabolismo , Zea mays/metabolismo , Transporte Biológico/efeitos dos fármacos , Eletrodos , Glicolatos/farmacologia , Ftalimidas/farmacologia , Raízes de Plantas/efeitos dos fármacos , Zea mays/efeitos dos fármacos
9.
Nanotechnology ; 22(35): 355502, 2011 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-21828892

RESUMO

This work addresses the comparison of different strategies for improving biosensor performance using nanomaterials. Glucose biosensors based on commonly applied enzyme immobilization approaches, including sol-gel encapsulation approaches and glutaraldehyde cross-linking strategies, were studied in the presence and absence of multi-walled carbon nanotubes (MWNTs). Although direct comparison of design parameters such as linear range and sensitivity is intuitive, this comparison alone is not an accurate indicator of biosensor efficacy, due to the wide range of electrodes and nanomaterials available for use in current biosensor designs. We proposed a comparative protocol which considers both the active area available for transduction following nanomaterial deposition and the sensitivity. Based on the protocol, when no nanomaterials were involved, TEOS/GOx biosensors exhibited the highest efficacy, followed by BSA/GA/GOx and TMOS/GOx biosensors. A novel biosensor containing carboxylated MWNTs modified with glucose oxidase and an overlying TMOS layer demonstrated optimum efficacy in terms of enhanced current density (18.3 ± 0.5 µA mM(-1) cm(-2)), linear range (0.0037-12 mM), detection limit (3.7 µM), coefficient of variation (2%), response time (less than 8 s), and stability/selectivity/reproducibility. H(2)O(2) response tests demonstrated that the most possible reason for the performance enhancement was an increased enzyme loading. This design is an excellent platform for versatile biosensing applications.


Assuntos
Técnicas Biossensoriais/instrumentação , Enzimas Imobilizadas/síntese química , Glucose Oxidase/química , Glucose/análise , Nanotubos de Carbono/química , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/instrumentação , Eletrodos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Ferricianetos/química , Glucose/metabolismo , Glucose Oxidase/metabolismo , Peróxido de Hidrogênio/química , Modelos Lineares , Compostos de Organossilício/química , Platina/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Silanos/química
10.
J Am Chem Soc ; 131(34): 12082-3, 2009 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-19670862

RESUMO

A motion-based chemical sensing involving fuel-driven nanomotors is demonstrated. The new protocol relies on the use of an optical microscope for tracking changes in the speed of nanowire motors in the presence of the target analyte. Selective and sensitive measurements of trace silver ions are illustrated based on the dramatic and specific acceleration of bimetal nanowire motors in the presence of silver. Such nanomotor-based measurements would lead to a wide range of novel and powerful chemical and biological sensing protocols.


Assuntos
Química Analítica/instrumentação , Movimento (Física) , Nanofios/química , Prata/análise , Catálise , Platina/química , Prata/química