Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Oncol ; 24(5): 509-522, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37142373

RESUMO

BACKGROUND: Low-intensity pulsed ultrasound with concomitant administration of intravenous microbubbles (LIPU-MB) can be used to open the blood-brain barrier. We aimed to assess the safety and pharmacokinetics of LIPU-MB to enhance the delivery of albumin-bound paclitaxel to the peritumoural brain of patients with recurrent glioblastoma. METHODS: We conducted a dose-escalation phase 1 clinical trial in adults (aged ≥18 years) with recurrent glioblastoma, a tumour diameter of 70 mm or smaller, and a Karnofsky performance status of at least 70. A nine-emitter ultrasound device was implanted into a skull window after tumour resection. LIPU-MB with intravenous albumin-bound paclitaxel infusion was done every 3 weeks for up to six cycles. Six dose levels of albumin-bound paclitaxel (40 mg/m2, 80 mg/m2, 135 mg/m2, 175 mg/m2, 215 mg/m2, and 260 mg/m2) were evaluated. The primary endpoint was dose-limiting toxicity occurring during the first cycle of sonication and albumin-bound paclitaxel chemotherapy. Safety was assessed in all treated patients. Analyses were done in the per-protocol population. Blood-brain barrier opening was investigated by MRI before and after sonication. We also did pharmacokinetic analyses of LIPU-MB in a subgroup of patients from the current study and a subgroup of patients who received carboplatin as part of a similar trial (NCT03744026). This study is registered with ClinicalTrials.gov, NCT04528680, and a phase 2 trial is currently open for accrual. FINDINGS: 17 patients (nine men and eight women) were enrolled between Oct 29, 2020, and Feb 21, 2022. As of data cutoff on Sept 6, 2022, median follow-up was 11·89 months (IQR 11·12-12·78). One patient was treated per dose level of albumin-bound paclitaxel for levels 1 to 5 (40-215 mg/m2), and 12 patients were treated at dose level 6 (260 mg/m2). A total of 68 cycles of LIPU-MB-based blood-brain barrier opening were done (median 3 cycles per patient [range 2-6]). At a dose of 260 mg/m2, encephalopathy (grade 3) occurred in one (8%) of 12 patients during the first cycle (considered a dose-limiting toxicity), and in one other patient during the second cycle (grade 2). In both cases, the toxicity resolved and treatment continued at a lower dose of albumin-bound paclitaxel, with a dose of 175 mg/m2 in the case of the grade 3 encephalopathy, and to 215 mg/m2 in the case of the grade 2 encephalopathy. Grade 2 peripheral neuropathy was observed in one patient during the third cycle of 260 mg/m2 albumin-bound paclitaxel. No progressive neurological deficits attributed to LIPU-MB were observed. LIPU-MB-based blood-brain barrier opening was most commonly associated with immediate yet transient grade 1-2 headache (12 [71%] of 17 patients). The most common grade 3-4 treatment-emergent adverse events were neutropenia (eight [47%]), leukopenia (five [29%]), and hypertension (five [29%]). No treatment-related deaths occurred during the study. Imaging analysis showed blood-brain barrier opening in the brain regions targeted by LIPU-MB, which diminished over the first 1 h after sonication. Pharmacokinetic analyses showed that LIPU-MB led to increases in the mean brain parenchymal concentrations of albumin-bound paclitaxel (from 0·037 µM [95% CI 0·022-0·063] in non-sonicated brain to 0·139 µM [0·083-0·232] in sonicated brain [3·7-times increase], p<0·0001) and carboplatin (from 0·991 µM [0·562-1·747] in non-sonicated brain to 5·878 µM [3·462-9·980] µM in sonicated brain [5·9-times increase], p=0·0001). INTERPRETATION: LIPU-MB using a skull-implantable ultrasound device transiently opens the blood-brain barrier allowing for safe, repeated penetration of cytotoxic drugs into the brain. This study has prompted a subsequent phase 2 study combining LIPU-MB with albumin-bound paclitaxel plus carboplatin (NCT04528680), which is ongoing. FUNDING: National Institutes of Health and National Cancer Institute, Moceri Family Foundation, and the Panattoni family.


Assuntos
Encefalopatias , Glioblastoma , Adulto , Masculino , Humanos , Feminino , Adolescente , Paclitaxel Ligado a Albumina/efeitos adversos , Carboplatina , Glioblastoma/diagnóstico por imagem , Glioblastoma/tratamento farmacológico , Barreira Hematoencefálica , Paclitaxel , Encefalopatias/induzido quimicamente , Encefalopatias/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico
2.
Curr Opin Oncol ; 35(6): 522-528, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37681417

RESUMO

PURPOSE OF REVIEW: Glioblastoma (GBM), the most prevalent primary brain malignancy in adults, poses significant challenges in terms of treatment. Current therapeutic strategies for GBM patients involve maximal safe resection, followed by radiotherapy with concurrent and adjuvant temozolomide. However, despite this multimodal approach for GBM, the prognosis of GBM patients remains dismal because of their inherent primary and secondary resistances to treatments. RECENT FINDINGS: Several molecular and cellular mechanisms, including the presence of the blood-brain barrier (BBB), contribute to these resistances. The BBB, comprising multiple layers surrounding brain vessels, acts as a barrier limiting effective drug delivery to the brain. Invasive and noninvasive tools to deliver drugs and pharmaceutical formulations locally or systemically are continuously evolving to overcome the BBB in GBM toward improving drug bioavailability in the brain and reducing systemic toxicities. SUMMARY: Preliminary studies utilizing these approaches have demonstrated promising results in terms of safety and signals of efficacy during early-phase clinical trials. However, further work through additional clinical trials is necessary to evaluate the potential clinical benefits for GBM patients.

3.
J Neurooncol ; 151(1): 65-73, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32112296

RESUMO

INTRODUCTION: Opening of the blood-brain barrier (BBB) by pulsed low intensity ultrasound has been developed during the last decade and is now recognized as a safe technique to transiently and repeatedly open the BBB. This non- or minimally invasive technique allows for a targeted and uniform dispersal of a wide range of therapeutic substances throughout the brain, including immune cells and antibodies. METHODS: In this review article, we summarize pre-clinical studies that have used BBB-opening by pulsed low intensity ultrasound to enhance the delivery of immune therapeutics and effector cell populations, as well as several recent clinical studies that have been initiated. Based on this analysis, we propose immune therapeutic strategies that are most likely to benefit from this strategy. The literature review and trial data research were performed using Medline/Pubmed databases and clinical trial registry www.clinicaltrials.gov . The reference lists of all included articles were searched for additional studies. RESULTS: A wide range of immune therapeutic agents, including small molecular weight drugs, antibodies or NK cells, have been safely and efficiently delivered to the brain with pulsed low intensity ultrasound in preclinical models, and both tumor control and increased survival have been demonstrated in different types of brain tumor models in rodents. Ultrasound-induced BBB disruption may also stimulate innate and cellular immune responses. CONCLUSIONS: Ultrasound BBB opening has just recently entered clinical trials with encouraging results, and the association of this strategy with immune therapeutics creates a new field of brain tumor treatment.


Assuntos
Barreira Hematoencefálica , Neoplasias do Sistema Nervoso Central , Encéfalo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/terapia , Neoplasias do Sistema Nervoso Central/diagnóstico por imagem , Neoplasias do Sistema Nervoso Central/terapia , Humanos , Ondas Ultrassônicas , Ultrassonografia
4.
Neurosurg Focus ; 48(1): E10, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31896084

RESUMO

Pediatric brain tumors are the most common solid tumor and the first cause of cancer death in childhood, adolescence, and young adulthood. Current treatments are far from optimal in most of these tumors and the prognosis remains dismal for many of them. One of the main causes of the failure of current medical treatments is in part due to the existence of the blood-brain barrier (BBB), which limits drug delivery to tumors. Opening of the BBB with low-intensity pulsed ultrasound (LIPU) has emerged during the last 2 decades as a promising technique for enhancing drug delivery to the brain. In preclinical models, enhanced delivery of a wide range of therapeutic agents, from low-molecular-weight drugs, to antibodies and immune cells, has been observed as well as tumor control and increased survival. This technique has recently entered clinical trials with extracranial and intracranial devices. The safety and feasibility of this technique has furthermore been shown in patients treated monthly for recurrent glioblastoma receiving carboplatin chemotherapy. In this review, the characteristics of the BBB in the most common pediatric brain tumors are reviewed. Then, principles and mechanisms of BBB disruption with ultrasound (US) are summarized and described at the histological and biological levels. Lastly, preclinical studies that have used US-induced BBB opening in tumor models, recent clinical trials, and the potential use of this technology in pediatrics are provided.


Assuntos
Barreira Hematoencefálica/patologia , Neoplasias Encefálicas/tratamento farmacológico , Recidiva Local de Neoplasia/tratamento farmacológico , Ondas Ultrassônicas , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/patologia , Glioma/diagnóstico , Glioma/tratamento farmacológico , Glioma/patologia , Humanos , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/patologia , Pediatria
5.
J Neurooncol ; 144(1): 33-41, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31197598

RESUMO

INTRODUCTION: Glioblastoma (GBM) is the most common and aggressive primary brain cancer in adults. Few cytotoxic chemotherapies have been shown to be effective against GBM, due in part to the presence of the blood-brain barrier (BBB), which reduces the penetration of chemotherapies from the blood to the brain. Ultrasound-induced BBB opening (US-BBB) has been shown to increase the penetration of multiple chemotherapeutic agents in the brain in animal models. In the current study, the anti-tumor activity of carboplatin chemotherapy with and without US-BBB was investigated in several GBM mouse models. METHODS: First, the IC50 of two commercial (U87 and U251) and six patient-derived GBM cell lines (PDCL) to carboplatin was measured. Next, U87 was subcutaneously grafted to a nude mouse model to test the in vivo response of the tumor to carboplatin in the absence of the BBB. Lastly, nude mice bearing orthotopically xenografted GBM cell lines (U87 or a PDCL) were randomized to four experimental groups: (i) untreated, (ii) US-BBB alone, (iii) carboplatin alone and, (iv) carboplatin + US-BBB. Mice were treated once weekly for 4 weeks and monitored for toxicity, tumor growth, and survival. RESULTS: Carboplatin plus US-BBB enhanced survival (p = 0.03) and delayed tumor growth (p < 0.05) of GBM-bearing mice compared to carboplatin alone, with a 4.2-fold increase of carboplatin penetration in the brain, without evidence of significant neurological or systemic toxicity. CONCLUSIONS: Carboplatin efficacy was enhanced in GBM mouse models with US-BBB and appears to be a promising chemotherapy for this approach.


Assuntos
Antineoplásicos/farmacologia , Barreira Hematoencefálica/efeitos dos fármacos , Neoplasias Encefálicas/tratamento farmacológico , Carboplatina/farmacologia , Modelos Animais de Doenças , Glioblastoma/tratamento farmacológico , Ondas Ultrassônicas , Animais , Antineoplásicos/farmacocinética , Apoptose , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/efeitos da radiação , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/patologia , Carboplatina/farmacocinética , Proliferação de Células , Feminino , Glioblastoma/metabolismo , Glioblastoma/patologia , Humanos , Camundongos , Camundongos Nus , Distribuição Tecidual , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
6.
Clin Cancer Res ; 30(8): 1619-1629, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38295144

RESUMO

PURPOSE: We recently reported on clinical trials for patients with recurrent glioblastoma where low-intensity pulsed ultrasound and microbubbles (LIPU/MB) improved paclitaxel or carboplatin delivery into the brain. Here, we report variable local tumor control with paclitaxel at the maximal/target dose in our phase I trial (NCT04528680). To address this, we investigated the combination of paclitaxel with carboplatin in preclinical glioma models. EXPERIMENTAL DESIGN: We performed MRI-based analysis to evaluate disease control in patients from our trial. We studied the cytotoxicity of paclitaxel and carboplatin against 11 human glioma lines as monotherapy and in combination at concentrations derived from human intraoperative studies. Synergy was assessed with the Loewe model and the survival benefit evaluated in two xenografts. We examined the effects on cell cycle progression, DNA damage, and apoptosis. RESULTS: Patients treated with paclitaxel and LIPU/MB exhibited variable local tumor control, which correlated with overall survival. We observed limited cross-resistance to paclitaxel and carboplatin in glioma lines, with almost a third of them being exclusively susceptible to one drug. This combination led to susceptibility of 81% of lines and synergy in 55% of them. The combination proved more efficacious in two intracranial xenografts when administered with LIPU/MB, leading to complementary effects on cell cycle arrest. CONCLUSIONS: Combining paclitaxel and carboplatin in gliomas may be more efficacious than monotherapy, as in other cancers, due to synergy and independent susceptibility to each drug. These results form the basis for an ongoing phase II trial (NCT04528680) where we investigate this combination with LIPU/MB.


Assuntos
Glioblastoma , Glioma , Humanos , Carboplatina , Paclitaxel , Glioblastoma/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Recidiva Local de Neoplasia/tratamento farmacológico , Glioma/tratamento farmacológico
7.
Nat Commun ; 15(1): 1650, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396134

RESUMO

Here, the results of a phase 1/2 single-arm trial (NCT03744026) assessing the safety and efficacy of blood-brain barrier (BBB) disruption with an implantable ultrasound system in recurrent glioblastoma patients receiving carboplatin are reported. A nine-emitter ultrasound implant was placed at the end of tumor resection replacing the bone flap. After surgery, activation to disrupt the BBB was performed every four weeks either before or after carboplatin infusion. The primary objective of the Phase 1 was to evaluate the safety of escalating numbers of ultrasound emitters using a standard 3 + 3 dose escalation. The primary objective of the Phase 2 was to evaluate the efficacy of BBB opening using magnetic resonance imaging (MRI). The secondary objectives included safety and clinical efficacy. Thirty-three patients received a total of 90 monthly sonications with carboplatin administration and up to nine emitters activated without observed DLT. Grade 3 procedure-related adverse events consisted of pre syncope (n = 3), fatigue (n = 1), wound infection (n = 2), and pain at time of device connection (n = 7). BBB opening endpoint was met with 90% of emitters showing BBB disruption on MRI after sonication. In the 12 patients who received carboplatin just prior to sonication, the progression-free survival was 3.1 months, the 1-year overall survival rate was 58% and median overall survival was 14.0 months from surgery.


Assuntos
Barreira Hematoencefálica , Glioblastoma , Humanos , Carboplatina/efeitos adversos , Barreira Hematoencefálica/patologia , Glioblastoma/diagnóstico por imagem , Glioblastoma/tratamento farmacológico , Ultrassonografia , Transporte Biológico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
8.
Nat Commun ; 15(1): 4698, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844770

RESUMO

Given the marginal penetration of most drugs across the blood-brain barrier, the efficacy of various agents remains limited for glioblastoma (GBM). Here we employ low-intensity pulsed ultrasound (LIPU) and intravenously administered microbubbles (MB) to open the blood-brain barrier and increase the concentration of liposomal doxorubicin and PD-1 blocking antibodies (aPD-1). We report results on a cohort of 4 GBM patients and preclinical models treated with this approach. LIPU/MB increases the concentration of doxorubicin by 2-fold and 3.9-fold in the human and murine brains two days after sonication, respectively. Similarly, LIPU/MB-mediated blood-brain barrier disruption leads to a 6-fold and a 2-fold increase in aPD-1 concentrations in murine brains and peritumoral brain regions from GBM patients treated with pembrolizumab, respectively. Doxorubicin and aPD-1 delivered with LIPU/MB upregulate major histocompatibility complex (MHC) class I and II in tumor cells. Increased brain concentrations of doxorubicin achieved by LIPU/MB elicit IFN-γ and MHC class I expression in microglia and macrophages. Doxorubicin and aPD-1 delivered with LIPU/MB results in the long-term survival of most glioma-bearing mice, which rely on myeloid cells and lymphocytes for their efficacy. Overall, this translational study supports the utility of LIPU/MB to potentiate the antitumoral activities of doxorubicin and aPD-1 for GBM.


Assuntos
Barreira Hematoencefálica , Neoplasias Encefálicas , Doxorrubicina , Microbolhas , Receptor de Morte Celular Programada 1 , Doxorrubicina/farmacologia , Doxorrubicina/administração & dosagem , Doxorrubicina/uso terapêutico , Doxorrubicina/análogos & derivados , Animais , Humanos , Receptor de Morte Celular Programada 1/antagonistas & inibidores , Receptor de Morte Celular Programada 1/metabolismo , Camundongos , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/efeitos dos fármacos , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/imunologia , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Glioma/tratamento farmacológico , Glioma/imunologia , Glioma/patologia , Encéfalo/metabolismo , Encéfalo/efeitos dos fármacos , Feminino , Sistemas de Liberação de Medicamentos , Ondas Ultrassônicas , Glioblastoma/tratamento farmacológico , Glioblastoma/imunologia , Glioblastoma/patologia , Masculino , Microglia/efeitos dos fármacos , Microglia/metabolismo , Camundongos Endogâmicos C57BL , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/farmacologia , Inibidores de Checkpoint Imunológico/farmacologia , Inibidores de Checkpoint Imunológico/administração & dosagem , Polietilenoglicóis
9.
J Acoust Soc Am ; 134(2): 1647-55, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927205

RESUMO

Interstitial thermal therapy is a minimally invasive treatment modality that has been used clinically for ablating both primary and secondary brain tumors. Here a multi-element interstitial ultrasound applicator is described that allows for increased spatial control during thermal ablation of tumors as compared to existing clinical devices. The device consists of an array of 56 ultrasound elements operating at 6 MHz, oriented on the seven faces of a 3.2 mm flexible catheter. The device was first characterized using the acoustic holography method to examine the functioning of the array. Then experiments were performed to measure heating in tissue-mimicking gel phantoms and ex vivo tissue samples using magnetic resonance imaging-based thermometry. Experimental measurements were compared with results obtained using numerical simulations. Last, simulations were performed to study the feasibility of using the device for thermal ablation in the brain. Experimental results show that the device can be used to induce a temperature rise of greater than 20 °C in ex vivo tissue samples and numerical simulations further demonstrate that tumors with diameters of greater than 30-mm could potentially be treated.


Assuntos
Neoplasias Encefálicas/cirurgia , Catéteres , Transdutores , Terapia por Ultrassom/instrumentação , Neoplasias Encefálicas/patologia , Simulação por Computador , Desenho de Equipamento , Estudos de Viabilidade , Holografia , Temperatura Alta , Imageamento por Ressonância Magnética , Modelos Biológicos , Análise Numérica Assistida por Computador , Termografia/métodos , Carga Tumoral , Terapia por Ultrassom/efeitos adversos
10.
Pharmaceutics ; 15(2)2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36839777

RESUMO

Therapeutic antibodies targeting immune checkpoints have shown limited efficacy in clinical trials in glioblastoma (GBM) patients. Ultrasound-mediated blood-brain barrier opening (UMBO) using low-intensity pulsed ultrasound improved drug delivery to the brain. We explored the safety and the efficacy of UMBO plus immune checkpoint inhibitors in preclinical models of GBM. A blood-brain barrier (BBB) opening was performed using a 1 MHz preclinical ultrasound system in combination with 10 µL/g microbubbles. Brain penetration of immune checkpoint inhibitors was determined, and immune cell populations were evaluated using flow cytometry. The impact of repeated treatments on survival was determined. In syngeneic GL261-bearing immunocompetent mice, we showed that UMBO safely and repeatedly opened the BBB. BBB opening was confirmed visually and microscopically using Evans blue dye and magnetic resonance imaging. UMBO plus anti-PDL-1 was associated with a significant improvement of overall survival compared to anti-PD-L1 alone. Using mass spectroscopy, we showed that the penetration of therapeutic antibodies can be increased when delivered intravenously compared to non-sonicated brains. Furthermore, we observed an enhancement of activated microglia percentage when combined with anti-PD-L1. Here, we report that the combination of UMBO and anti-PD-L1 dramatically increases GL261-bearing mice's survival compared to their counterparts treated with anti-PD-L1 alone. Our study highlights the BBB as a limitation to overcome in order to increase the efficacy of anti-PD-L1 in GBM and supports clinical trials combining UMBO and in GBM patients.

11.
Cancers (Basel) ; 15(3)2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36765816

RESUMO

Brain and spinal tumors affect 1 in 1000 people by 25 years of age, and have diverse histological, biological, anatomical and dissemination characteristics. A mortality of 30-40% means the majority are cured, although two-thirds have life-long disability, linked to accumulated brain injury that is acquired prior to diagnosis, and after surgery or chemo-radiotherapy. Only four drugs have been licensed globally for brain tumors in 40 years and only one for children. Most new cancer drugs in clinical trials do not cross the blood-brain barrier (BBB). Techniques to enhance brain tumor drug delivery are explored in this review, and cover those that augment penetration of the BBB, and those that bypass the BBB. Developing appropriate delivery techniques could improve patient outcomes by ensuring efficacious drug exposure to tumors (including those that are drug-resistant), reducing systemic toxicities and targeting leptomeningeal metastases. Together, this drug delivery strategy seeks to enhance the efficacy of new drugs and enable re-evaluation of existing drugs that might have previously failed because of inadequate delivery. A literature review of repurposed drugs is reported, and a range of preclinical brain tumor models available for translational development are explored.

12.
Alzheimers Res Ther ; 14(1): 40, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35260178

RESUMO

BACKGROUND: Temporary disruption of the blood-brain barrier (BBB) using pulsed ultrasound leads to the clearance of both amyloid and tau from the brain, increased neurogenesis, and mitigation of cognitive decline in pre-clinical models of Alzheimer's disease (AD) while also increasing BBB penetration of therapeutic antibodies. The goal of this pilot clinical trial was to investigate the safety and efficacy of this approach in patients with mild AD using an implantable ultrasound device. METHODS: An implantable, 1-MHz ultrasound device (SonoCloud-1) was implanted under local anesthesia in the skull (extradural) of 10 mild AD patients to target the left supra-marginal gyrus. Over 3.5 months, seven ultrasound sessions in combination with intravenous infusion of microbubbles were performed twice per month to temporarily disrupt the BBB. 18F-florbetapir and 18F-fluorodeoxyglucose positron emission tomography (PET) imaging were performed on a combined PET/MRI scanner at inclusion and at 4 and 8 months after the initiation of sonications to monitor the brain metabolism and amyloid levels along with cognitive evaluations. The evolution of cognitive and neuroimaging features was compared to that of a matched sample of control participants taken from the Alzheimer's Disease Neuroimaging Initiative (ADNI). RESULTS: A total of 63 BBB opening procedures were performed in nine subjects. The procedure was well-tolerated. A non-significant decrease in amyloid accumulation at 4 months of - 6.6% (SD = 7.2%) on 18F-florbetapir PET imaging in the sonicated gray matter targeted by the ultrasound transducer was observed compared to baseline in six subjects that completed treatments and who had evaluable imaging scans. No differences in the longitudinal change in the glucose metabolism were observed compared to the neighboring or contralateral regions or to the change observed in the same region in ADNI participants. No significant effect on cognition evolution was observed in comparison with the ADNI participants as expected due to the small sample size and duration of the trial. CONCLUSIONS: These results demonstrate the safety of ultrasound-based BBB disruption and the potential of this technology to be used as a therapy for AD patients. Research of this technique in a larger clinical trial with a device designed to sonicate larger volumes of tissue and in combination with disease-modifying drugs may further enhance the effects observed. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03119961.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Doença de Alzheimer/terapia , Barreira Hematoencefálica/diagnóstico por imagem , Barreira Hematoencefálica/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Disfunção Cognitiva/metabolismo , Humanos , Neuroimagem/métodos , Projetos Piloto , Tomografia por Emissão de Pósitrons/métodos
13.
J Acoust Soc Am ; 130(5): 3498-510, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22088025

RESUMO

In high intensity focused ultrasound (HIFU) applications, tissue may be thermally necrosed by heating, emulsified by cavitation, or, as was recently discovered, emulsified using repetitive millisecond boiling caused by shock wave heating. Here, this last approach was further investigated. Experiments were performed in transparent gels and ex vivo bovine heart tissue using 1, 2, and 3 MHz focused transducers and different pulsing schemes in which the pressure, duty factor, and pulse duration were varied. A previously developed derating procedure to determine in situ shock amplitudes and the time-to-boil was refined. Treatments were monitored using B-mode ultrasound. Both inertial cavitation and boiling were observed during exposures, but emulsification occurred only when shocks and boiling were present. Emulsified lesions without thermal denaturation were produced with shock amplitudes sufficient to induce boiling in less than 20 ms, duty factors of less than 0.02, and pulse lengths shorter than 30 ms. Higher duty factors or longer pulses produced varying degrees of thermal denaturation combined with mechanical emulsification. Larger lesions were obtained using lower ultrasound frequencies. The results show that shock wave heating and millisecond boiling is an effective and reliable way to emulsify tissue while monitoring the treatment with ultrasound.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Temperatura Alta , Fígado/cirurgia , Miocárdio/patologia , Animais , Bovinos , Ecocardiografia , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Fígado/diagnóstico por imagem , Fígado/patologia , Necrose , Imagens de Fantasmas , Pressão , Fatores de Tempo , Transdutores de Pressão
14.
Clin Cancer Res ; 27(15): 4325-4337, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34031054

RESUMO

PURPOSE: The blood-brain barrier (BBB) inhibits adequate dosing/penetration of therapeutic agents to malignancies in the brain. Low-intensity pulsed ultrasound (LIPU) is a safe therapeutic method of temporary BBB disruption (BBBD) to enhance chemotherapeutic delivery to the tumor and surrounding brain parenchyma for treatment of glioblastoma. EXPERIMENTAL DESIGN: We investigated if LIPU could enhance therapeutic efficacy of anti-PD-1 in C57BL/6 mice bearing intracranial GL261 gliomas, epidermal growth factor receptor variant III (EGFRvIII) chimeric antigen receptor (CAR) T cells in NSG mice with EGFRvIII-U87 gliomas, and a genetically engineered antigen-presenting cell (APC)-based therapy producing the T-cell attracting chemokine CXCL10 in the GL261-bearing mice. RESULTS: Mice treated with anti-PD-1 and LIPU-induced BBBD had a median survival duration of 58 days compared with 39 days for mice treated with anti-PD-1, and long-term survivors all remained alive after contralateral hemisphere rechallenge. CAR T-cell administration with LIPU-induced BBBD resulted in significant increases in CAR T-cell delivery to the CNS after 24 (P < 0.005) and 72 (P < 0.001) hours and increased median survival by greater than 129%, in comparison with CAR T cells alone. Local deposition of CXCL10-secreting APCs in the glioma microenvironment with LIPU enhanced T-cell glioma infiltration during the therapeutic window (P = 0.004) and markedly enhanced survival (P < 0.05). CONCLUSIONS: LIPU increases immune therapeutic delivery to the tumor microenvironment with an associated increase in survival and is an emerging technique for enhancing novel therapies in the brain.


Assuntos
Barreira Hematoencefálica/efeitos da radiação , Neoplasias Encefálicas/terapia , Glioma/terapia , Imunoterapia , Ondas Ultrassônicas , Animais , Modelos Animais de Doenças , Camundongos , Camundongos Endogâmicos C57BL , Resultado do Tratamento
15.
Cancer Lett ; 479: 13-22, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32112904

RESUMO

The treatment of primary brain tumors, especially malignant gliomas, remains challenging. The failure of most treatments for this disease is partially explained by the blood-brain barrier (BBB), which prevents circulating molecules from entering the brain parenchyma. Ultrasound-induced BBB disruption (US-BBBD) has recently emerged as a promising strategy to improve the delivery of therapeutic agents to brain tumors. A large body of preclinical studies has demonstrated that the association of low-intensity pulsed ultrasound with intravenous microbubbles can transiently open the BBB in a localized manner. The safety of this technique has been assessed in numerous preclinical studies in both small and large animal models. A large panel of therapeutic agents have been delivered to the brain in preclinical models, demonstrating both tumor control and increased survival. This technique has recently entered clinical trials with encouraging preliminary data. In this review, we describe the mechanisms and histological effects of US-BBBD and summarize the preclinical studies published to date. We furthermore provide an overview of the current clinical development and future potential of this promising technology.


Assuntos
Barreira Hematoencefálica/patologia , Neoplasias Encefálicas/terapia , Glioma/terapia , Terapia por Ultrassom/métodos , Animais , Humanos , Microbolhas , Ondas Ultrassônicas
16.
Clin Cancer Res ; 26(2): 477-486, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31831565

RESUMO

PURPOSE: Paclitaxel shows little benefit in the treatment of glioma due to poor penetration across the blood-brain barrier (BBB). Low-intensity pulsed ultrasound (LIPU) with microbubble injection transiently disrupts the BBB allowing for improved drug delivery to the brain. We investigated the distribution, toxicity, and efficacy of LIPU delivery of two different formulations of paclitaxel, albumin-bound paclitaxel (ABX) and paclitaxel dissolved in cremophor (CrEL-PTX), in preclinical glioma models. EXPERIMENTAL DESIGN: The efficacy and biodistribution of ABX and CrEL-PTX were compared with and without LIPU delivery. Antiglioma activity was evaluated in nude mice bearing intracranial patient-derived glioma xenografts (PDX). Paclitaxel biodistribution was determined in sonicated and nonsonicated nude mice. Sonications were performed using a 1 MHz LIPU device (SonoCloud), and fluorescein was used to confirm and map BBB disruption. Toxicity of LIPU-delivered paclitaxel was assessed through clinical and histologic examination of treated mice. RESULTS: Despite similar antiglioma activity in vitro, ABX extended survival over CrEL-PTX and untreated control mice with orthotropic PDX. Ultrasound-mediated BBB disruption enhanced paclitaxel brain concentration by 3- to 5-fold for both formulations and further augmented the therapeutic benefit of ABX. Repeated courses of LIPU-delivered CrEL-PTX and CrEL alone were lethal in 42% and 37.5% of mice, respectively, whereas similar delivery of ABX at an equivalent dose was well tolerated. CONCLUSIONS: Ultrasound delivery of paclitaxel across the BBB is a feasible and effective treatment for glioma. ABX is the preferred formulation for further investigation in the clinical setting due to its superior brain penetration and tolerability compared with CrEL-PTX.


Assuntos
Albuminas/farmacologia , Albuminas/farmacocinética , Composição de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/métodos , Glioma/tratamento farmacológico , Paclitaxel/farmacologia , Paclitaxel/farmacocinética , Polietilenoglicóis/química , Ultrassonografia/métodos , Animais , Barreira Hematoencefálica/efeitos dos fármacos , Feminino , Glioma/patologia , Masculino , Camundongos , Camundongos Nus , Microbolhas/uso terapêutico , Nanopartículas/química , Taxa de Sobrevida , Distribuição Tecidual , Ensaios Antitumorais Modelo de Xenoenxerto
17.
J Acoust Soc Am ; 125(4): 2420-31, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19354416

RESUMO

Both mechanically induced acoustic cavitation and thermally induced boiling can occur during high intensity focused ultrasound (HIFU) medical therapy. The goal was to monitor the temperature as boiling was approached using magnetic resonance imaging (MRI). Tissue phantoms were heated for 20 s in a 4.7-T magnet using a 2-MHz HIFU source with an aperture and radius of curvature of 44 mm. The peak focal pressure was 27.5 MPa with corresponding beam width of 0.5 mm. The temperature measured in a single MRI voxel by water proton resonance frequency shift attained a maximum value of only 73 degrees C after 7 s of continuous HIFU exposure when boiling started. Boiling was detected by visual observation, by appearance on the MR images, and by a marked change in the HIFU source power. Nonlinear modeling of the acoustic field combined with a heat transfer equation predicted 100 degrees C after 7 s of exposure. Averaging of the calculated temperature field over the volume of the MRI voxel (0.3 x 0.5 x 2 mm(3)) yielded a maximum of 73 degrees C that agreed with the MR thermometry measurement. These results have implications for the use of MRI-determined temperature values to guide treatments with clinical HIFU systems.


Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Modelos Teóricos , Dinâmica não Linear , Imagens de Fantasmas , Temperatura , Fatores de Tempo , Ultrassonografia/métodos
18.
J Neurosurg ; 132(3): 875-883, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30717050

RESUMO

OBJECTIVE: One of the goals in this study was to set up a semiautomatic method to estimate blood-brain barrier disruption obtained in patients with glioblastoma by using an implantable, unfocused, ultrasound device. Another goal was to correlate the probability of significant ultrasound-induced signal enhancement (SUISE) with local acoustic pressure in the brain. METHODS: Gd-enhanced MR images acquired before and after ultrasound treatments were analyzed prospectively. The image sets were segmented, normalized, and coregistered to evaluate contrast enhancement. The volume of SUISE was calculated with voxels labeled as gray or white matter, in a cylindrical region of interest, and with enhancement above a given threshold. To validate the method, the resulting volumes of SUISE were compared to qualitative grades previously assigned by 3 clinicians for 40 ultrasound treatments in 15 patients. A parametric study was performed to optimize the algorithm prediction of the qualitative grades. The 3D acoustic field in the brain was estimated from measurements in water combined with simulations accounting for ultrasound attenuation in brain and overlaid on each MR image to correlate local acoustic pressure with the probability of SUISE (defined as enhancement > 10%). RESULTS: The algorithm predicted grade 2 or 3 and grade 3 openings with areas under the receiver operating characteristic curve of 0.831 and 0.995, respectively. The probability of SUISE was correlated with local acoustic pressure (R2 = 0.98) and was 3.33 times higher for gray matter than for white matter. CONCLUSIONS: An algorithm for evaluating blood-brain barrier disruption was validated and can be used for future clinical trials to further understand and quantify this technique in humans.Clinical trial registration no.: NCT02253212 (clinicaltrials.gov).

19.
Ultrasound Med Biol ; 45(9): 2417-2426, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31248640

RESUMO

The blood-spinal cord barrier (BSCB) considerably limits the delivery and efficacy of treatments for spinal cord diseases. The blood-brain barrier can be safely opened with low-intensity pulsed ultrasound when microbubbles are simultaneously administered intravenously. This technique was tested on the BSCB in a rabbit model in this work. Twenty-three segments of spinal cord were sonicated with a 1-MHz unfocused pulsed ultrasound device and compared with non-sonicated segments. BSCB disruption was assessed using Evan's blue dye (EBD) extravasation. Tolerance was assessed by histologic analysis. An increased EBD concentration indicating BSCB disruption was clearly observed in sonicated segments compared with controls (p = 0.004). On one animal, which received 10 sonications, repetitive BSCB disruptions revealed no evidence of cumulative toxicity. BSCB can be disrupted using an unfocused pulsed ultrasound device in combination with microbubbles without neurotoxicity even in case of repeated sonications.


Assuntos
Medula Espinal/metabolismo , Ultrassom/métodos , Animais , Meios de Contraste/farmacocinética , Azul Evans/farmacocinética , Microbolhas , Modelos Animais , Fosfolipídeos/farmacocinética , Coelhos , Hexafluoreto de Enxofre/farmacocinética
20.
Clin Cancer Res ; 25(13): 3793-3801, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30890548

RESUMO

PURPOSE: The blood-brain barrier (BBB) limits the efficacy of drug therapies for glioblastoma (GBM). Preclinical data indicate that low-intensity pulsed ultrasound (LIPU) can transiently disrupt the BBB and increase intracerebral drug concentrations. PATIENTS AND METHODS: A first-in-man, single-arm, single-center trial (NCT02253212) was initiated to investigate the transient disruption of the BBB in patients with recurrent GBM. Patients were implanted with a 1-MHz, 11.5-mm diameter cranial ultrasound device (SonoCloud-1, CarThera). The device was activated monthly to transiently disrupt the BBB before intravenous carboplatin chemotherapy. RESULTS: Between 2014 and 2016, 21 patients were registered for the study and implanted with the SonoCloud-1; 19 patients received at least one sonication. In 65 ultrasound sessions, BBB disruption was visible on T1w MRI for 52 sonications. Treatment-related adverse events observed were transient and manageable: a transient edema at H1 and at D15. No carboplatin-related neurotoxicity was observed. Patients with no or poor BBB disruption (n = 8) visible on MRI had a median progression-free survival (PFS) of 2.73 months, and a median overall survival (OS) of 8.64 months. Patients with clear BBB disruption (n = 11) had a median PFS of 4.11 months, and a median OS of 12.94 months. CONCLUSIONS: SonoCloud-1 treatments were well tolerated and may increase the effectiveness of systemic drug therapies, such as carboplatin, in the brain without inducing neurotoxicity.See related commentary by Sonabend and Stupp, p. 3750.


Assuntos
Glioblastoma , Ondas Ultrassônicas , Barreira Hematoencefálica , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Recidiva Local de Neoplasia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA