Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(7): 4475-4483, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38127075

RESUMO

OBJECTIVES: To assess the incidence (1 year) and the cumulative incidence (3 years) of the condition of patients accruing cumulative effective doses (CED) of ≥ 100 mSv and their variability among different hospitals. To establish and validate a reference level for the CED in patients with recurrent exposures (RERL) and provide a RERL value. METHODS: Data of CT exposure was collected in 9 similar hospitals. The database included 294,222 patient*years who underwent 442,278 CT exams in 3 years. The incidence proportion of patients with CED ≥ 100 mSv in a given year (I100;1) and the 3-year cumulative incidence of patients with CED ≥ 100 mSv over 3 consecutive years (I100;3) were calculated and compared among different institutions. RESULTS: I100;1 ranged from a minimum of 0.1% to a maximum of 5.1%. The percentage of recurrent patients was quite uniform among centres ranging from 23 to 38%. The I100;3 ranged from a minimum of 1.1 to 11.4%. There was a strong positive correlation between the third quartile values of yearly CED and yearly incidence (r = 0.90; R2 = 0.81; p < 0.0001). RERL value in our study was found at 34.0 mSv. CONCLUSION: The management of patients with recurrent exposures is highly variable among hospitals leading to a 50-fold variation in I100;1 and to a tenfold variation in I100;3. RERL could be established and used by taking as a RERL quantity the CED and as a RERL value the 75th percentile of the third quartiles of the distribution of the yearly CED obtained by surveying different hospitals. CLINICAL RELEVANCE STATEMENT: This is the first ever multicentre study that quantifies recurrent exposures in terms of incidence and cumulative incidence of patients with CED ≥ 100 mSv. RERL establishment and use could benefit the optimisation of radioprotection of patients with recurrent exposures. KEY POINTS: This is the first multicentre study estimating yearly incidence and 3-year cumulative incidence of patients with cumulative effective doses ≥ 100 mSv. In this study, a 50-fold inter centre variation between the maximum (5.1%) and the minimum value (0.1%) of yearly incidence of patients with cumulative effective doses ≥ 100 mSv was reported. The range of the 3-year cumulative incidence extended from 1.1 to 11.4% (a tenfold variation) The third quartile of the yearly cumulative effective doses in a centre showed a strong positive correlation with the yearly incidence of patients with cumulative effective doses ≥ 100 mSv, with a potential of being used to set reference levels for recurrent exposures.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Adulto , Incidência , Feminino , Masculino , Exposição à Radiação/prevenção & controle , Valores de Referência , Proteção Radiológica/métodos , Pessoa de Meia-Idade , Recidiva
2.
Eur Radiol ; 31(7): 4452-4458, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33449187

RESUMO

OBJECTIVES: To estimate the number of patients who receive a cumulative effective dose (CED) of ≥ 100 mSv from computed tomography (CT) in a single day or episode of care. METHODS: We examined 28,870 patients who underwent 49,834 CT examinations in a tertiary care centre in Italy in 2.5 years. Radiation exposures were retrieved from the hospital's automatic exposure monitoring system. Two cohorts were identified as those who received a CED of ≥ 100 mSv in a single day and within a month starting from the first examination. Organ doses were estimated for the first cohort. RESULTS: Among the 1765 (6.1%) patients who received CED ≥ 100 mSv in the observation period, 427 received a CED of ≥ 100 mSv within a month (and 70 patients in a single day). This group represented 1.5% of all patients who underwent CT exams and 24% of those who received CED ≥ 100 mSv in the observation period. The clinical indication for referral included cancer in 132 patients (31%) and non-oncological indications in 295 patients (69%). In 68/70 patients with CED > 100 mSv in a single day, at least one organ/tissue received a dose of ≥ 100 mGy. CONCLUSIONS: The finding of a sizeable percentage of patients undergoing CT exams and receiving CED ≥ 100 mSv in a single episode of care points toward the need of imaging appropriateness criteria, to revise the routine protocols, to replace older machines, and to provide to the radiologist the patient's prior radiation history to facilitate an appropriate decision-making process. KEY POINTS: • Patients can receive effective doses greater than 100 mSv in a single CT or in multiple CT examinations performed in a single episode of care in 1.5% of patients in a 2.5-year period. • In this study, the clinical indication for CT referral was non-oncological in 69% of patients. • The patient's prior radiation history should be provided to the referring physicians and the radiological medical practitioner to facilitate an appropriate decision-making process.


Assuntos
Cuidado Periódico , Exposição à Radiação , Humanos , Itália , Doses de Radiação , Tomografia Computadorizada por Raios X
3.
Phys Med ; 122: 103383, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38810393

RESUMO

PURPOSE: Radiation doses to adult patients submitted to cerebral angiography and intracranial aneurysms treatments were assessed by using DICOM Radiation Dose Structured Reports (RDSR) and Monte Carlo simulations. Conversion factors to estimate effective and organ doses from Kerma-Area Product (PKA) values were determined. METHODS: 77 cerebral procedures performed with five angiographic equipment installed in three Italian centres were analyzed. Local settings and acquisition protocols were considered. The geometrical, technical and dosimetric data of 16,244 irradiation events (13305 fluoroscopy, 2811 digital subtraction angiography, 128 cone-beam CT) were extracted from RDSRs by local dose monitoring systems and were input in MonteCarlo PCXMC software to calculate effective and organ doses. Finally, conversion factors to determine effective and organ doses from PKA were determined. Differences between centres were assessed through statistical analysis and accuracy of dose calculation method based on conversion factors was assessed through Bland-Altman analysis. RESULTS: Large variations in PKA (14-561 Gycm2) and effective dose (1.2-73.5 mSv) were observed due to different degrees of complexity in the procedures and angiographic system technology. The most exposed organs were brain, salivary glands, oral mucosa, thyroid and skeleton. The study highlights the importance of recent technology in reducing patient exposure (about fourfold, even more in DSA). No statistically significant difference was observed in conversion factors between centres, except for some organs. A conversion factor of 0.09 ± 0.02 mSv/Gycm2 was obtained for effective dose. CONCLUSIONS: Organ and effective doses were assessed for neuro-interventional procedures. Conversion factors for calculating effective and organ doses from PKA were provided.


Assuntos
Doses de Radiação , Humanos , Método de Monte Carlo , Angiografia Cerebral , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/radioterapia , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Radiometria , Angiografia Digital
4.
Phys Med ; 110: 102603, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37178623

RESUMO

PURPOSE: To assess occupational eye lens dose based on clinical monitoring of interventional radiologists and to assess personal protective eyewear (PPE) efficacy through measurements with anthropomorphic phantom. METHODS: Two positions of the operator with respect to X-ray beam were simulated with phantom. Dose reduction factor (DRF) of four PPE was assessed, as well as correlation between eye lens and whole-body doses. Brain dose was also assessed. Five radiologists were monitored for one-year clinical procedures. All subjects were equipped with whole-body dosimeter placed over lead apron at the chest level and eye lens dosimeter placed over the left side of the PPE. Kerma-Area Product (KAP) of procedures performed during the monitoring period was recorded. The correlation of eye lens dose with whole-body dose and KAP was assessed. RESULTS: DRF was 4.3/2.4 for wraparound glasses, 4.8/1.9 for fitover glasses, 9.1/6.8 for full-face visor in radial/femoral geometries. DRF of half-face visor depended on how it is worn (range 1.0-4.9). Statistically significant correlation between dose value over the PPE and chest dose was observed, while there was no correlation between eye lens dose and chest dose. The results on clinical staff showed statistically significant correlation between dose values over the PPE and KAP. CONCLUSIONS: All PPE showed significant DRF in all configurations, provided they were worn correctly. Single DRF value is not applicable to all clinical situations. KAP is a valuable tool for determining appropriate radiation protection measures.


Assuntos
Cristalino , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Radiologia Intervencionista/métodos , Doses de Radiação , Dispositivos de Proteção dos Olhos , Proteção Radiológica/métodos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Exposição à Radiação/prevenção & controle
5.
Br J Radiol ; 96(1149): 20230106, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37493259

RESUMO

OBJECTIVE: To assess the cumulated exposure to radiation due to imaging in Hodgkin (HL) and diffuse large B-cell (DLBCL) lymphoma patients who were not submitted to radiotherapy. METHODS: The study population included 51 and 83 adult patients with HL and DLBCL, with a follow-up duration >1 year. The cumulated exposure was expressed using patient-specific data as cumulated effective dose (CED). RESULTS: Fifty-one HL patients (median age 47 years) were followed for a median of 3.5 years. The median total CED per subject was 104 mSv. CT and PET/CT examinations accounted for 75 and 25% of the total CED, respectively. 26 patients (49%) had a total CED ≥ 100 mSv and the maximum CED was 302 mSv. Eighty-three DLBCL patients (median age 66 years) were followed for a median of 3.7 years. The median total CED per subject over the study period was 134 mSv. CT and PET/CT for 86% and 13% of the total CED, respectively. 56 patients (67%) had a total CED ≥100 mSv. The maximum CED was 557 mSv. CONCLUSION: Our study demonstrated the large number of imaging procedures performed for patients with lymphoma. Overall, 61% of the patients accrued a CED ≥ 100 mSv. Imaging policies were only in a partial agreement with current international guidelines. ADVANCES IN KNOWLEDGE: The cumulated exposure radiation exposure may be of concern in HL patients and the contribution of CT procedures to the total CED is significant. The standardisation of clinical guidelines for managing patients with lymphoma is warranted.


Assuntos
Linfoma Difuso de Grandes Células B , Exposição à Radiação , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doses de Radiação , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Linfoma Difuso de Grandes Células B/radioterapia
6.
Phys Med ; 81: 40-46, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33373780

RESUMO

Histerosalpingography (HSG) remains the dominant diagnostic tool for investigation of infertility in women. Conversion factors used to estimate effective (E) and organ doses (HT) from air Kerma area product (KAP) are needed to estimate patient doses in HSG, performed with state-of-the-art fluoroscopic X-ray systems with digital detectors. In this study, estimates of E and HT for six critical organs/tissues, were derived on an individual basis in 120 HSG procedures and in 1410 irradiation events, performed on two X-ray systems from information available through the radiation dose structured report using Monte Carlo methods. Mean values of E and Hovaries were1.0 ± 0.9 mSv and 5.6 ± 5.4 mGy. E/KAP conversion factors of 0.13; 0.18; 0.28 and 0.35 mSv Gy-1cm-2 were established for irradiation events with a Cu filtration of 0.0; 0.1; 0.4 and 0.9 mm. A high agreement was obtained between E estimated through Monte Carlo methods and E/KAP conversion factors accounting separately for the different modes of fluoroscopy and the radiography component of HSG, with a systematic error of 0 mSv and lower/upper limits of agreement of -0.6 and 0.5 mSv. On the contrary, the use of a single coefficient of conversion did not provide accurate estimates of E, showing a bias of -0.4 mSv and lower and upper limits of agreement of -1.9 and 1.2 mSv. An algorithm for the estimation of effective and organ doses from KAP has been established in HSG procedures depending on the Cu filtration in the X-ray irradiation events.


Assuntos
Histerossalpingografia , Feminino , Fluoroscopia , Humanos , Método de Monte Carlo , Doses de Radiação , Radiografia
7.
Int J Radiat Oncol Biol Phys ; 70(5): 1423-6, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-17931795

RESUMO

PURPOSE: To investigate the potential impact of using (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on staging and target volume delineation for patients affected by rectal cancer and candidates for preoperative conformal radiotherapy. METHODS AND MATERIALS: Twenty-five patients diagnosed with rectal cancer T3-4 N0-1 M0-1 and candidates for preoperative radiotherapy underwent PET/CT simulation after injection of 5.18 MBq/kg of FDG. Clinical stage was reassessed on the basis of FDG-PET/CT findings. The gross tumor volume (GTV) and the clinical target volume (CTV) were delineated first on CT and then on PET/CT images. The PET/CT-GTV and PET/CT-CTV were analyzed and compared with CT-GTV and CT-CTV, respectively. RESULTS: In 4 of 25 cases (24%), PET/CT affected tumor staging or the treatment purpose. In 3 of 25 cases (12%) staged N0 M0, PET/CT showed FDG uptake in regional lymph nodes and in a case also in the liver. In a patient with a single liver metastasis PET/CT detected multiple lesions, changing the treatment intent from curative to palliative. The PET/CT-GTV and PET/CT-CTV were significantly greater than the CT-GTV (p = 0.00013) and CT-CTV (p = 0.00002), respectively. The mean difference between PET/CT-GTV and CT-GTV was 25.4% and between PET/CT-CTV and CT-CTV was 4.1%. CONCLUSIONS: Imaging with PET/CT for preoperative radiotherapy of rectal cancer may lead to a change in staging and target volume delineation. Stage variation was observed in 12% of cases and a change of treatment intent in 4%. The GTV and CTV changed significantly, with a mean increase in size of 25% and 4%, respectively.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Neoplasias Retais , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Carga Corporal (Radioterapia) , Feminino , Humanos , Neoplasias Hepáticas/secundário , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Radioterapia Conformacional , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia
8.
Invest Ophthalmol Vis Sci ; 59(12): 5074-5081, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30357402

RESUMO

Purpose: To evaluate peripapillary vessel density and morphology in patients with diabetes mellitus (DM) without clinical signs of diabetic retinopathy (DR) and with mild, nonproliferative DR and to correlate with peripapillary nerve fiber layer (NFL) thickness. Methods: One hundred seventeen eyes (34 healthy controls, 54 patients with DM without DR [noDR group] and 24 patients with mild DR [DR group]) were prospectively evaluated. All subjects underwent peripapillary and macular optical coherence tomography angiography (OCT-A). Peripapillary NFL thickness was also recorded. OCT-A slab of radial peripapillary plexus (RPC) and macular superficial capillary plexus (SCP) were analysed in order to calculate perfusion density (PD) and vessel density (VD). Further an image analysis of RPC slab was performed to identify number of branches (NoB) and total branches length (tBL). Results: In peripapillary area there was a significant decrease in VD (P = 0.003), NoB (P < 0.001), and tBL (P < 0.001) in noDR group versus controls; PD values were not different among groups (P = 0.126); there was a significant decrease in average NFL thickness in DR versus controls (P = 0.008) and in the inferior quadrant in noDR group versus controls (P = 0.03); there was a significant correlation between OCT-A and NFL thickness values (ρ ranging from 0.19-0.57). In macular region PD and VD were decreased only in DR group (P < 0.05). Conclusions: There are early changes in the peripapillary vessel morphology and VD of the RPC in patients with DM without DR that correlate to NFL thinning. Earlier changes in superficial vessel density are documented in the peripapillary than in the macular region. These data may confirm a coexistence of an early neuronal and microvascular damage in patients with DM without clinical signs of DR.


Assuntos
Diabetes Mellitus/patologia , Retinopatia Diabética/patologia , Fibras Nervosas/patologia , Disco Óptico/irrigação sanguínea , Células Ganglionares da Retina/patologia , Vasos Retinianos/patologia , Adulto , Idoso , Pressão Sanguínea/fisiologia , Estudos de Casos e Controles , Estudos Transversais , Diabetes Mellitus/diagnóstico por imagem , Retinopatia Diabética/diagnóstico por imagem , Feminino , Angiofluoresceinografia , Hemoglobinas Glicadas/metabolismo , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Campos Visuais
9.
Ann Nucl Med ; 19(2): 75-82, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15909485

RESUMO

PURPOSE: To characterize ordered-subset expectation maximization algorithm with a fixed 3D Gauss post-reconstruction filtering (OSEM) in 99mTc SPECT as for noise, contrast and spatial resolution with varying number of subset and iteration and to compare OSEM with an optimized set of parameters, with filtered backprojection (FBP) with filter parameters typical of brain and myocardial SPECT, both with and without Chang's method of attenuation correction (AC). METHODS: SPECT images of a Jaszczak phantom with cold rod inserts, hot and cold spheres and capillary line sources were acquired. Different background activity concentrations of the phantom were simulated as well as different lesion-to-background activity ratios. OSEM reconstructions were halted after 5, 10 and 15 iterations using 4, 8 and 16 subsets. RESULTS: The effect of subset and iteration number over noise is additive: thus, it is possible to define an EM-equivalent iteration number that indicates the product between the subset and the iteration numbers. Noise increases linearly with increasing EM-equivalent iteration number. For each level of nominal contrast, the measured contrast after OSEM shows a little increase with increasing iteration number and saturates after 80 EM-equivalent iterations. The application of AC leads to diminished contrast values both in FBP and OSEM. The contrast of cold lesions after OSEM increases with increasing number of EM-equivalent iteration number: after 80 iterations the contrast values with OSEM overtake the ones obtained with FBP; contrast values diminished as background concentration raised. Resolution values did not change with increasing EM-equivalent iteration number and were higher than those obtained with FBP. CONCLUSION: The major findings of the present work are the demonstration of additivity of subset and iteration in OSEM over noise, with the possibility of defining an EM equivalent iteration number, and the superiority of OSEM with respect to FBP in terms of spatial resolution.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Funções Verossimilhança , Modelos Biológicos , Modelos Estatísticos , Distribuição Normal , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
10.
Radiat Oncol ; 5: 10, 2010 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-20137093

RESUMO

BACKGROUND: FDG-PET/CT imaging has an emerging role in staging and treatment planning of various tumor locations and a number of literature studies show that also the carcinoma of the anal canal may benefit from this diagnostic approach. We analyzed the potential impact of FDG-PET/CT in stage definition and target volume delineation of patients affected by carcinoma of the anal canal and candidates for curative radiotherapy. METHODS: Twenty seven patients with biopsy proven anal carcinoma were enrolled. Pathology was squamous cell carcinoma in 20 cases, cloacogenic carcinoma in 3, adenocarcinoma in 2, and basal cell carcinoma in 2. Simulation was performed by PET/CT imaging with patient in treatment position. Gross Tumor Volume (GTV) and Clinical Target Volume (CTV) were drawn on CT and on PET/CT fused images. PET-GTV and PET-CTV were respectively compared to CT-GTV and CT-CTV by Wilcoxon rank test for paired data. RESULTS: PET/CT fused images led to change the stage in 5/27 cases (18.5%): 3 cases from N0 to N2 and 2 from M0 to M1 leading to change the treatment intent from curative to palliative in a case.Based on PET/CT imaging, GTV and CTV contours changed in 15/27 (55.6%) and in 10/27 cases (37.0%) respectively. PET-GTV and PET-CTV resulted significantly smaller than CT-GTV (p = 1.2 x 10(-4)) and CT-CTV (p = 2.9 x 10(-4)). PET/CT-GTV and PET/CT-CTV, that were used for clinical purposes, were significantly greater than CT-GTV (p = 6 x 10(-5)) and CT-CTV (p = 6 x 10(-5)). CONCLUSIONS: FDG-PET/CT has a potential relevant impact in staging and target volume delineation of the carcinoma of the anal canal. Clinical stage variation occurred in 18.5% of cases with change of treatment intent in 3.7%. The GTV and the CTV changed in shape and in size based on PET/CT imaging.


Assuntos
Neoplasias do Ânus/patologia , Carcinoma/patologia , Estadiamento de Neoplasias/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
11.
Technol Cancer Res Treat ; 9(4): 393-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20626204

RESUMO

To analyze the inter-observer variability and the potential impact of (18)F-fluorodeoxyglucose (FDG)-positron emission tomography/computed tomography (PET/CT) imaging for target volume delineation in preoperative radiotherapy of rectal cancer. Gross tumor volume (GTV) and clinical target volume (CTV) in 2 cases of rectal cancer were contoured by 10 radiation oncologists, 5 on CT and 5 on PET/CT images. Resulting volumes were analyzed by coefficient of variation (CV) and concordance index (CI). Mean GTV was 120 cc +/- 20.4 cc in case A and 119 cc +/- 35.7 cc in case B. Mean CTV was 723 cc +/- 147.5 cc in case A and 739 cc +/- 195.6 cc in case B. CV was lower and CI was similar or higher across the observers contouring GTV on PET/CT. CTV variability was less influenced by the use of PET/CT. PET/CT may allow reducing inter-observer variability in GTV delineation.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Retais/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Variações Dependentes do Observador , Cuidados Pré-Operatórios , Prognóstico , Compostos Radiofarmacêuticos , Neoplasias Retais/radioterapia
12.
Int J Radiat Oncol Biol Phys ; 66(4): 1100-4, 2006 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16965862

RESUMO

PURPOSE: This study aims to investigate the in vivo drainage of lymphatic spread by using the sentinel node (SN) technique and single-photon emission computed tomography (SPECT)-computed tomography (CT) image fusion, and to analyze the impact of such information on conformal pelvic irradiation. METHODS AND MATERIALS: Twenty-three prostate cancer patients, candidates for radical prostatectomy already included in a trial studying the SN technique, were enrolled. CT and SPECT images were obtained after intraprostate injection of 115 MBq of 99mTc-nanocolloid, allowing identification of SN and other pelvic lymph nodes. Target and nontarget structures, including lymph nodes identified by SPECT, were drawn on SPECT-CT fusion images. A three-dimensional conformal treatment plan was performed for each patient. RESULTS: Single-photon emission computed tomography lymph nodal uptake was detected in 20 of 23 cases (87%). The SN was inside the pelvic clinical target volume (CTV2) in 16 of 20 cases (80%) and received no less than the prescribed dose in 17 of 20 cases (85%). The most frequent locations of SN outside the CTV2 were the common iliac and presacral lymph nodes. Sixteen of the 32 other lymph nodes (50%) identified by SPECT were found outside the CTV2. Overall, the SN and other intrapelvic lymph nodes identified by SPECT were not included in the CTV2 in 5 of 20 (25%) patients. CONCLUSIONS: The study of lymphatic drainage can contribute to a better knowledge of the in vivo potential pattern of lymph node metastasis in prostate cancer and can lead to a modification of treatment volume with consequent optimization of pelvic irradiation.


Assuntos
Linfonodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/radioterapia , Biópsia de Linfonodo Sentinela/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Pelve/patologia , Pelve/efeitos da radiação , Prognóstico , Técnica de Subtração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA