RESUMO
BACKGROUND: Nonfluoroscopic mapping systems have demonstrated significant reduction of radiation exposure in radiofrequency (RF) catheter ablation procedures. However, their use as only imaging guide is still limited. OBJECTIVE: To evaluate the usefulness of a completely nonfluoroscopic approach to catheter ablation of supraventricular arrhythmias using the Ensite-NavX™ electroanatomical navigation system. METHODS: During 6 years, all consecutive patients referred for RF catheter ablation of regular supraventricular tachycardia (SVT) were admitted for a "zero-fluoroscopy" approach and studied prospectively. The only exclusion criterion was the need to perform a transseptal puncture. RESULTS: A total of 340 procedures were performed on 328 patients (179 men, age 55.7 ± 18.6 years). One hundred fifty-three patients had typical atrial flutter (AFL), 146 had AV nodal reentrant tachycardia (AVNRT), 35 had AV reciprocating tachycardia (AVRT), 4 patients had incisional atrial flutter (IAF), and 2 had focal atrial tachycardia (AT). Procedural success was achieved in 337 of the cases (99.1%). In 322 (94.7%), the procedure was completed without any fluoroscopy use. Mean procedure time was 110.5 ± 51.8 minutes. Mean RF application time was 9.8 ± 12.8 minutes and the number of RF lesions was 16.43 ± 15.8. Only 1 major complication related to vascular access was recorded. During follow-up, there were 12 recurrences (3.5%) (8 patients from the AVNRT group, 4 patients from the AP group). CONCLUSION: RF catheter ablation of SVT with an approach completely guided by the NavX system and without use of fluoroscopy is feasible, safe, and effective.