Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Paediatr Dent ; 2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38881275

RESUMO

BACKGROUND: Motivational interviewing (MI) is an approach to increase parental compliance to follow up and recall of their children. It has proven to be successful in motivating parents to adopt and maintain preventive child oral health behaviors. AIM: To assess the effectiveness of motivational interviewing on prevention strategies for parents of children who have received full-mouth dental rehabilitation under general anesthesia (GA). DESIGN: This is a parallel-arm randomized controlled trial. Parents in the treatment arm were randomized and received a combination of motivational interviewing, individualized goal setting, visual aids, and verbal education post-GA. Those in the control arm received the same information by verbal and written education. Both groups were evaluated at 2-week follow-up and 3-month recall. Differences in attendance, oral health knowledge, readiness to change, and parental self-efficacy (PSE) were compared between groups and at return visits. RESULTS: Of 74 parents of children randomly allocated in this study, 22 (61%) and 13 (38%) from the intervention group, and 21 (55%) and 16 (46%) from the control group attended the 2-week, and 3-month follow-up, respectively. The average PSE for participants in the intervention group was significantly higher than that of the control group at the follow-up visit (p = .0050). CONCLUSION: Readiness to change dietary habits and average PSE for parents in the intervention group were significantly higher than that of the control group after receiving the modified preventive strategy.

2.
Am J Orthod Dentofacial Orthop ; 165(6): 671-679, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38506775

RESUMO

INTRODUCTION: Clear aligner technology based on a machine learning algorithm is currently available for orthodontic treatment. Treatment planning on the basis of 3-dimensional crown, root, and bone imaging is claimed to provide accurate diagnosis and better treatment outcomes for adult patients with complex needs. This study aimed to answer the following questions: (1) would practitioners modify their original treatment plan once provided with the crown, root, and bone view? and (2) does practitioner satisfaction regarding treatment outcomes change once the crown, root, and bone view is provided? METHODS: An online questionnaire was emailed to members of the American Association of Orthodontists (n = 2300) and the Virginia Orthodontic Education and Research Foundation (n = 211). The survey consisted of videos of 4 patients shown in 2 presentations: crown-only and crown, root, and bone views, generated by artificial intelligence-driven treatment planning software (3D Predict aligner system; 3D Predict, New York, NY). Respondents were asked to answer treatment-related questions and rate the treatment outcomes using a visual analog scale. Statistical analyses were completed to determine the significance of crown, root, and bone view on treatment planning with clear aligners. RESULTS: A total of 70 orthodontists participated in the survey. There were significant differences in responses when viewing patients in crown-only and crown, root, and bone presentations. Across the 4 patients, 33%-43% of practitioners changed their sentiment toward the treatment plan (P <0.001). When rating satisfaction on the 100-point scale, average ratings changed by 10.6 to 21.0 points; both increases and decreases in satisfaction were seen across the patients (P <0.001). CONCLUSIONS: When given 3-dimensional information on the position of a patient's crowns, root, and bone coverage, orthodontists are likely to change their clear aligner treatment plan. This study showed that a confirmation of dehiscence and fenestrations using the root and bone view resulted in practitioner dissatisfaction despite an initial satisfaction with the crown-only view.


Assuntos
Imageamento Tridimensional , Raiz Dentária , Humanos , Raiz Dentária/diagnóstico por imagem , Imageamento Tridimensional/métodos , Planejamento de Assistência ao Paciente , Coroa do Dente/diagnóstico por imagem , Inquéritos e Questionários , Tomada de Decisão Clínica , Adulto , Resultado do Tratamento
3.
Gen Dent ; 72(4): 54-57, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38905606

RESUMO

The purpose of this study was to determine the most effective method for bonding composite resin to artificially aged amalgam. A spherical amalgam alloy was triturated and condensed by hand into cylindrical plastic molds (6 mm in diameter and 4 mm in height) to create 90 specimens, which were then aged for 2 weeks in closed plastic containers at 23°C. The amalgam surfaces underwent 1 of 3 surface treatments (n = 30 per treatment): (1) air particle abrasion (APA) with 50-µm aluminum oxide particles applied with a force of 45 psi from a 10-mm distance, followed by rinsing with deionized water for 60 seconds; (2) APA following the same protocol with subsequent application of a metal primer (Alloy Primer); or (3) coating with 30-µm silica (CoJet) at a force of 45 psi from a 10-mm distance until the surface turned black. Specimens were then treated with 1 of 3 adhesives (n = 10 per adhesive per surface treatment): (1) 2-step total-etch adhesive (OptiBond Solo Plus), (2) 1-step self-etching adhesive (Scotchbond Universal), or (3) dual-cured resin cement (Panavia F 2.0). Each adhesive was applied to the treated amalgam surfaces following its manufacturer's instructions. The specimens were placed in a bonding clamp, and nanocomposite resin columns, 2.38 mm in diameter and 2.00 mm in height, were photocured (40 seconds, 500 mW/cm2) against the treated amalgam surfaces. The specimens were stored for 24 hours in 37°C deionized water and underwent shear bond strength testing at a crosshead speed of 0.5 mm/min. Data were analyzed using 2-way analysis of variance and post hoc analysis with the Tukey test at 95% confidence. The mean (SD) shear bond strength values ranged from 12.3 (1.2) MPa for aluminum oxide-treated surfaces bonded with OptiBond Solo Plus to 25.9 (4.6) MPa for silicoated surfaces bonded with Panavia F 2.0. All bonding agents produced the highest shear bond strength when the amalgam surface was silicoated. These results indicate that composite can be effectively bonded to amalgam via silicoating.


Assuntos
Resinas Compostas , Amálgama Dentário , Colagem Dentária , Amálgama Dentário/uso terapêutico , Resinas Compostas/uso terapêutico , Colagem Dentária/métodos , Propriedades de Superfície , Reparação de Restauração Dentária/métodos , Humanos , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Teste de Materiais , Resistência ao Cisalhamento , Metacrilatos , Tionas
4.
J Clin Periodontol ; 50(12): 1658-1669, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37855275

RESUMO

AIM: To determine the effects of RVX-208, a selective bromodomain and extra-terminal domain (BET) inhibitor targeting bromodomain 2 (BD2), on periodontal inflammation and bone loss. MATERIALS AND METHODS: Macrophage-like cells (RAW264.7) and human gingival epithelial cells were challenged by Porphyromonas gingivalis (Pg) with or without RVX-208. Inflammatory gene expression and cytokine production were measured by reverse transcription polymerase chain reaction and enzyme-linked immunosorbent assay, respectively. RAW264.7 cells were induced to osteoclast differentiation. After RVX-208 treatment, osteoclast differentiation was evaluated by histology, tartrate-resistant-acid-phosphatase (TRAP) activity and the expression of osteoclast-specific genes. The effect of RVX-208 on osteoclast transcriptome was studied by RNA sequencing. Periodontitis was induced in rats by ligature and local RVX-208 treatment was administered every other day. Alveolar bone loss was measured by micro-computed tomography. RESULTS: RVX-208 inhibited inflammatory gene expression and cytokine production in Pg-infected cells. Osteoclast differentiation was inhibited by RVX-208, as evidenced by reduced osteoclast number, TRAP activity and osteoclast-specific gene expression. RVX-208 displayed a more selective and less profound suppressive impact on transcriptome compared with pan-BET inhibitor, JQ1. RVX-208 administration prevented the alveolar bone loss in vivo. CONCLUSIONS: RVX-208 regulated both upstream (inflammatory cytokine production) and downstream (osteoclast differentiation) events that lead to periodontal tissue destruction, suggesting that it may be a promising 'epi-drug' for the prevention of periodontitis.


Assuntos
Perda do Osso Alveolar , Periodontite , Ratos , Humanos , Animais , Perda do Osso Alveolar/tratamento farmacológico , Perda do Osso Alveolar/prevenção & controle , Perda do Osso Alveolar/patologia , Microtomografia por Raio-X , Inflamação/tratamento farmacológico , Periodontite/tratamento farmacológico , Periodontite/prevenção & controle , Periodontite/patologia , Osteoclastos , Citocinas
5.
Am J Orthod Dentofacial Orthop ; 163(3): 328-337, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36411229

RESUMO

INTRODUCTION: Teledentistry in orthodontics is growing, yet patient preferences for its use is unknown. This study aimed to determine the perceived value of doctor-to-patient face-to-face interaction, convenience, and attitudes toward specific uses of teledentistry among orthodontic patients. METHODS: Private practice orthodontists emailed an electronic survey to active patients. Patients aged ≥18 years completed the survey regarding their treatment. Parents of patients aged <18 years completed a separate survey regarding their child's treatment. Responses were compared on the basis of patient characteristics (adult vs child, braces vs clear aligners, etc). RESULTS: Three hundred and seventy-seven respondents from 8 orthodontic practices participated in the survey. Eighty-five percent of parents considered face-to-face interaction important, and 85% said that their child's treatment fit conveniently into their schedule. Adult responses were 86% and 89%, respectively. Adult preference for face-to-face was significantly higher than parents of adolescent patients (83% vs 78%; P = 0.038). Adults treated with clear aligners were less likely to strongly agree that their treatment fitted conveniently in their schedule (51% vs 76% in braces; P = 0.0490) and were more likely to be interested in using teledentistry (27% vs 18% in braces; P = 0.0429). CONCLUSIONS: Most orthodontic patients prefer to be seen face-to-face. This is due to the high value placed on face-to-face interaction with the orthodontist. Most patients do not consider their treatment inconvenient. Patients prefer that teledentistry be used to enhance communication as opposed to replacing face-to-face interaction. Implementing teledentistry in orthodontics should be applied on a patient-to-patient basis with continued emphasis on the doctor-patient relationship.


Assuntos
Braquetes Ortodônticos , Ortodontia , Adulto , Criança , Adolescente , Humanos , Relações Médico-Paciente , Ortodontistas , Assistência Odontológica , Inquéritos e Questionários
6.
Am J Orthod Dentofacial Orthop ; 163(2): 252-259, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36376173

RESUMO

INTRODUCTION: This study aimed to assess the perceived efficacy of aligners (Invisalign; Align Technology, Santa Clara, Calif) at performing extrusive movements of maxillary lateral incisors and to evaluate and compare differences in treatment planning protocols and other interventions used when required between orthodontists and general dentists with various degrees of experience. METHODS: An original 18-question survey was sent by mail to a randomized and geographically proportionate selection of orthodontic specialists (N = 400) and general dentists (N = 400) listed as providers on the Invisalign Web site. The data were analyzed using analysis of variance and chi-square tests. RESULTS: One hundred twenty-six providers responded to the survey (15.8% response rate), including 36 general dentists and 90 orthodontists. Overall, the average perceived efficacy was 4.71 out of 10 (95% confidence interval, 4.28-5.14). The threshold for identification of tracking issues was significantly associated with provider type (P = 0.0305). General dentists were significantly more likely to prefer an optimized attachment (P = 0.0001), whereas orthodontists were significantly more likely to prefer a gingivally-beveled horizontal rectangular attachment (P <0.0001). A refinement scan was the most common intervention method, followed by the bootstrap technique. CONCLUSIONS: The average perceived efficacy for extruding maxillary lateral incisors with aligners was 4.71 out of 10. Orthodontists had a lower tolerance than general dentists for tracking issues. A refinement scan was the most common method of intervention. General dentists and orthodontists differed in their treatment planning preferences and timing of intervention.


Assuntos
Aparelhos Ortodônticos Removíveis , Ortodontia , Humanos , Incisivo , Ortodontistas , Inquéritos e Questionários
7.
Am J Orthod Dentofacial Orthop ; 164(1): 45-56, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36841666

RESUMO

INTRODUCTION: This study aimed to determine adaptations orthodontists made during the coronavirus disease 2019 pandemic to maintain safety and determine which adaptations will remain after the pandemic. METHODS: An original 34-question survey was sent by mail to a randomized selection of practicing orthodontic specialists (n = 1000). Questions included the changes made during the pandemic in 4 categories (infection control, social distancing, appliance type, and teleorthodontics) and whether those changes will remain postpandemic. RESULTS: The use of personal protective equipment increased during the pandemic, with a significant decrease anticipated after the pandemic. The most common aerosol modification during the pandemic and predicted after the pandemic was using an assistant with high-volume suction (61% and 49%, respectively; P = 0.0013). Ninety-six percent of orthodontists changed their waiting room protocol during the pandemic, but only 23% plan to continue that practice (P <0.0001). Forty-two percent of orthodontists increased clear aligners during the pandemic in response to patient demand (91%). The use of teleorthodontics increased from 8% to 68% during the pandemic and is expected to decrease significantly postpandemic. Virtual appointments are anticipated to be used for screening and consultations of new patients and monitoring active patients in clear aligners but not fixed appliances. CONCLUSIONS: The specialty recommended patient safety modifications during the coronavirus disease 2019 pandemic. Postpandemic, enhanced personal protective equipment is expected to decrease, and high-volume suction will likely be continued for aerosol-producing procedures. Teleorthodontics will likely remain in limited use.


Assuntos
COVID-19 , Ortodontia , Humanos , COVID-19/prevenção & controle , Ortodontistas , Encaminhamento e Consulta , Aparelhos Ortodônticos Fixos , Inquéritos e Questionários
8.
Am J Orthod Dentofacial Orthop ; 164(6): 879-888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37656070

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the accuracy of 3-dimensional (3D) printed aligners compared to conventional vacuum-formed thermoplastic aligners with varying levels of dental crowding. METHODS: Digital intraoral scans of 10 cases were assigned to their respective groups (n = 10, each, 30 total) as follows: no crowding (control), moderate crowding, and severe crowding. Digital images of these models were created in standard tessellation language (STL) file format using 3Shape software and randomly 3D printed. The STL files of each case were also sent to a dental laboratory to fabricate vacuum-formed samples, the current technology used for manufacturing aligners. The intaglio surfaces of fabricated aligners in both groups were scanned using cone beam computed tomography to create STL files, which were then compared to the original STL files of the cases using Geomagic Control X software. Absolute deviations from the original file and root mean square values were recorded. A Kruskal-Wallis test was conducted to analyze the difference in average deviation, and a t-test was repeated for the RMS measure. The significance level was set at 0.05. RESULTS: The crowding did not affect the trueness of aligners manufactured using 3D printing or conventional vacuum-forming techniques (P = 0.79). 3D-printed aligners showed less deviation than the vacuum-formed samples (0.1125 mm vs 0.1312 mm; P <0.01). Aligners manufactured with the vacuum-forming technique had significantly higher variation than those with the 3D printing process (P = 0.04). CONCLUSIONS: 3D aligners printed directly from an STL file exhibited better precision and trueness than those fabricated using the conventional vacuum-forming technique. Since accuracy is defined as a combination of precision and trueness, it is concluded that direct printing from an STL file can be used to manufacture aligners.


Assuntos
Desenho Assistido por Computador , Modelos Dentários , Humanos , Impressão Tridimensional , Software , Tomografia Computadorizada de Feixe Cônico
9.
Am J Orthod Dentofacial Orthop ; 164(2): 172-182, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36898898

RESUMO

INTRODUCTION: This study evaluated current trends and perspectives among orthodontists regarding clear aligner therapy in the mixed dentition (CAMD), including insights into perceived indications, compliance, oral hygiene, and other factors. METHODS: An original, 22-item survey was mailed to a randomized, nationally representative sample of practicing orthodontists (n = 800) and a specific, randomized subsample of high-aligner-prescribing orthodontists (n = 200). Questions assessed respondents' demographic information, experience with clear aligner therapy, and perceived advantages and disadvantages of CAMD compared with fixed appliances (FAs). Responses were compared using McNemar's chi-square and paired t tests to assess CAMD vs FAs. RESULTS: One thousand orthodontists were surveyed, and 181 (18.1%) responded over 12 weeks. CAMD use was less common than mixed dentition FAs, but most respondents predicted an increase in their future CAMD use (57.9%). Among respondents using CAMD, the number of patients with mixed dentition treated with clear aligners was significantly lower than the number of total patients with clear aligners (23.7% vs 43.8%; P <0.0001). Fewer respondents considered skeletal expansion, growth modification, sagittal correction, and habit cessation feasible indications for CAMD compared with FAs (P <0.0001). Perceived compliance was similar for CAMD and FAs (P = 0.5841), but perceived oral hygiene was significantly better with CAMD (P <0.0001). CONCLUSIONS: CAMD is an increasingly common treatment modality for children. Most surveyed orthodontists reported limited indications for CAMD compared with FAs but perceived noticeable benefits for oral hygiene with CAMD.


Assuntos
Dentição Mista , Aparelhos Ortodônticos Removíveis , Criança , Humanos , Ortodontistas , Projetos de Pesquisa , Aparelhos Ortodônticos Fixos
10.
Am J Orthod Dentofacial Orthop ; 164(5): 618-627, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37610383

RESUMO

INTRODUCTION: Extrusion of maxillary lateral incisors during aligner treatment is a difficult movement to achieve accurately. Despite recommendations regarding attachment design, few studies and no prospective trials compare predictability among attachments. This study aimed to compare the efficacy between optimized and horizontal attachment designs for achieving maxillary lateral incisor extrusion during clear aligner treatment. METHODS: The study included maxillary lateral incisors in 3 orthodontic practices requiring at least 0.3 mm of extrusion during the first series of 20-25 aligners in patients aged ≥16 years who were scheduled to begin clear aligner treatment (Invisalign; Align Technology, San Jose, Calif). Teeth were randomly assigned to receive optimized (O), rectangular horizontal nonbeveled (H), rectangular horizontal incisally-beveled (HIB), or rectangular horizontal gingivally-beveled (HGB) attachments. After the first series, a blinded evaluator measured extrusion using superimpositions with initial and predicted models. Linear models determined the difference in the predicted extrusion percentage achieved on the basis of attachment design. Other covariates were patient age, sex, number of trays, and self-reported compliance. RESULTS: Forty patients (74 teeth) were enrolled, and 38 patients (71 teeth) completed the study. Intraexaminer and interexaminer reliability for extrusion measurements was high (intraclass correlation coefficient, 0.985 and 0.991, respectively). The achieved extrusion was significantly less than predicted (mean, 73%; P <0.0001). The average achieved extrusion was 62%, 79%, 78%, and 78% for O, H, HIB, and HGB attachments, respectively, with H significantly more effective than O (P = 0.0403). Horizontal attachments (H, HIB, and HGB combined) were significantly more effective than O attachments (P = 0.0060), with an average difference in achieved extrusion of 14% of the predicted amount (95% confidence interval, 4-23; estimated 76% vs 62%). Horizontal attachments were an estimated 22% more effective than O attachments for extruding maxillary lateral incisors. CONCLUSIONS: Horizontal attachments are more effective than O attachments for predicted maxillary lateral incisor extrusion between 0.3 and 2.5 mm. The 3 horizontal attachment designs evaluated performed similarly for achieving predicted extrusion. TRIAL REGISTRATION: This randomized clinical trial was registered and reported at clinicaltrials.gov (NCT04968353). PROTOCOL: The protocol was not published before trial commencement. FUNDING: This study was funded in part by the Alexander Fellowship of the Virginia Commonwealth University School of Dentistry, the Southern Association of Orthodontists, and the Virginia Orthodontic Education and Research Foundation. No funding source influenced the study design, the collection, analysis or interpretation of data, writing of the report, or the decision to submit the article for publication.


Assuntos
Incisivo , Aparelhos Ortodônticos Removíveis , Adolescente , Adulto , Humanos , Reprodutibilidade dos Testes , Método Simples-Cego , Técnicas de Movimentação Dentária/métodos , Masculino , Feminino
11.
J Oral Maxillofac Surg ; 80(9): 1557-1563, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35594907

RESUMO

PURPOSE: Oral and maxillofacial surgeons frequently encounter patients who require extractions following exposure to head and neck radiation, and they must assess the risk of extraction and consider alternatives such as deliberate root retention. The purpose of this study was to determine whether dose volume would be a better predictor for osteoradionecrosis (ORN) than total dose. METHODS: This is a retrospective cohort study of patients diagnosed with ORN following head and neck radiation (administered between January 2006 and December 2018) and a comparison group selected based on site and dosage who did not develop ORN. The predictor variables were total radiation dose and mandibular dose volume, and the outcome variable was ORN occurrence. Covariates included age, sex, cancer stage and site, radiation therapy type, smoking status, alcohol use, adjuvant chemotherapy use, medical comorbidities, and concomitant tumor surgery. Logistic regression models were employed and area under receiver operating characteristic curve (AUROC) and model accuracy (Acc) were used to determine the better predictor. RESULTS: A total of 56 patients were included in the study: 27 ORN positive (ORN+) and 29 matched controls who did not develop ORN (ORN-). Most patients were male (76.8%), considered smokers (78.6%), used alcohol (80.4%), were in stage IV (66.1%), received chemotherapy (75.0%), and received intensity modulated radiation therapy radiation (55.4%). The statistical models with V50 Gy (cc) and V65 Gy (cc) dosage variables exhibited greater predictability of ORN occurrence than total dose (AUROC: 0.90 vs 0.76 and model accuracy: 0.82 vs 0.75, respectively). CONCLUSIONS: The results suggest that following head and neck radiation, dose volume may be a better predictor of ORN risk than total dose. This finding is significant, both for the oral and maxillofacial surgeon who is preoperatively assessing ORN risk following radiation exposure, and for the radiation oncologist striving to minimize the risk associated with their treatment.


Assuntos
Neoplasias de Cabeça e Pescoço , Doenças Mandibulares , Osteorradionecrose , Radioterapia de Intensidade Modulada , Feminino , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Masculino , Doenças Mandibulares/cirurgia , Osteorradionecrose/etiologia , Osteorradionecrose/cirurgia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos
12.
Int J Mol Sci ; 23(24)2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36555374

RESUMO

(1) Lasers have been used for the treatment of dentinal hypersensitivity and bacterial reductions in periodontology. The purpose of this in vitro study was to evaluate the effect of Carbon Dioxide (CO2) and Erbium-doped Yttrium Aluminum Garnet (Er:YAG) lasers with chlorhexidine (CHX), hydrogen peroxide (H2O2), sodium hypochlorite (NaOCl), or sodium fluoride (NaF) on the viability of oral bacteria associated with root caries. (2) Streptococcus mutans, Streptococcus sanguinis, and Enterococcus faecalis were grown in Brain Heart Infusion (BHI) broth, diluted to an OD660 of 0.5, and treated with antiseptics with or without simultaneous irradiation with the Er:YAG and CO2 lasers for 30 s repeated three times. The treatment groups consisted of 1: no treatment, 2: 0.5% H2O2 alone, 3: 0.5% NaOCl alone, 4: 0.12% CHX alone, 5: 2% NaF alone, 6: laser alone, 7: laser with 0.5% H2O2, 8: laser with 0.5% NaOCl, 9: laser with 0.12% CHX, and 10: laser with 2% NaF for both lasers. The microbial viability was determined through plating and viable colonies were counted, converted into CFU/mL, and transformed into log form. The statistical analysis was performed using a two-tailed paired t-test. (3) The use of CO2 and Er:YAG lasers alone failed to show statistically significant antibacterial activity against any of the bacteria. The only effective monotreatment was CHX for S. mutans. The combined treatment of 0.5% NaOCl with Er:YAG produced the greatest reduction in overall viability. (4) The combination of the Er:YAG laser with 0.5% NaOCl resulted in the largest reduction in bacterial survival when compared to monotherapies with antimicrobial solutions or lasers.


Assuntos
Lasers de Estado Sólido , Cárie Radicular , Humanos , Hipoclorito de Sódio/farmacologia , Peróxido de Hidrogênio/farmacologia , Clorexidina/farmacologia , Fluoreto de Sódio/farmacologia , Dióxido de Carbono/farmacologia , Lasers de Estado Sólido/uso terapêutico , Bactérias , Enterococcus faecalis
13.
Am J Orthod Dentofacial Orthop ; 161(3): 355-363.e3, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34776320

RESUMO

INTRODUCTION: The aims of this study were to (1) investigate and compare the educational value of the most popular YouTube (www.youtube.com; Google, San Bruno, Calif) orthodontic patient testimonials between braces, in-office aligners (IOA), and direct-to-consumer aligners (DTCA), and (2) classify the emotional response of the viewers through sentiment analysis of the video comments. METHODS: Three different phrases relevant to braces, IOA, and DTCA were searched on YouTube. The 20 most popular patient testimonial videos meeting the criteria for each group were selected for a total of 60 videos. Using the YouTube application program interface for each video, 13 video metrics were extracted. An information completeness score was assigned, and the video comments were analyzed using sentiment analysis software. RESULTS: The 60 videos included were viewed 34.4 million times by internet users. Braces videos had significantly more likes, comments, and a higher viewer interaction score than the IOA and DTCA videos. IOA videos had a higher median information completeness score than braces and DTCA videos. Of the 5149 video comments with polarity, 53.6% were positive, and 46.4% were negative (P <0.0001). There was no significant association between the treatment modality and positive or negative comments (P = 0.5679). CONCLUSIONS: There is high user engagement on YouTube with orthodontic patient testimonials. YouTube users interact with braces patient testimonials the most. YouTube viewers' comments on orthodontic patient testimonials express more positive sentiment than negative sentiment. There was no significant difference in positive and negative sentiment between the video comments for the 3 different treatment modalities.


Assuntos
Braquetes Ortodônticos , Mídias Sociais , Assistência Odontológica , Humanos , Aparelhos Ortodônticos Fixos , Gravação em Vídeo
14.
Am J Orthod Dentofacial Orthop ; 161(1): 133-139, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35012743

RESUMO

INTRODUCTION: The study aimed to (1) compare the accuracy and precision of 3-dimensional (3D) printed retainers at various angulations and (2) evaluate the effect of angulation on printing time and the amount of resin consumed. METHODS: Using a stereolithography 3D printer, 60 clear retainers were printed at 5 angulations (n = 12, each): 15°, 30°, 45°, 60°, and 90°. Samples for each group were randomly printed in a batch of 6 retainers at all print angulations as print 1 and print 2 cycles. Digital images of the original and printed samples were superimposed. Discrepancies on 8 landmarks were measured by 2 independent examiners, and 0.25 mm was set as the clinically acceptable threshold to determine the accuracy of the retainers. RESULTS: Deviations ranged from 0.074 mm to 0.225 mm from the reference retainer at the cusp tips and incisal edges at all angulations, falling within the threshold of clinical acceptance. However, smooth surface measurements with deviations up to 0.480 mm were deemed clinically not acceptable. Three-dimensional printing at 15° was estimated to be the most time-efficient, whereas 3D printing at 45° was shown to be the most cost-effective setting. CONCLUSIONS: Three-dimensional printed retainers, using a stereolithography printer, were found to be accurate within 0.25 mm at all print angulations at the cusp tips and incisal edges compared with the digital reference file. Smooth facial surfaces did not meet clinical acceptability. Print angulations were shown to affect the cost and amount of resin used.


Assuntos
Contenções Ortodônticas , Estereolitografia , Humanos , Impressão Tridimensional
15.
Am J Orthod Dentofacial Orthop ; 161(4): 582-591, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35337648

RESUMO

INTRODUCTION: This study aimed to evaluate the differences in the precision, trueness, and accuracy of 3-dimensional (3D) printed clear orthodontic retainers fabricated using printer systems with different printing technologies. METHODS: Retainers (n = 15) were 3D printed using 4 different printers: stereolithography (SLA), digital light processing (DLP), continuous DLP, and polyjet photopolymer (PPP) printers. Printed retainers were transformed into a digital image through a cone-beam computed tomography scan and compared with the original image using 3D superimposition analysis software. At previously chosen landmarks (R6, L6, R3, L3, R1, and L1), intaglio surfaces of the retainers were compared to that of the reference model. The intercanine and the intermolar width measurements were also assessed. A discrepancy of up to 0.25 mm between the printed retainer and the reference retainer intaglio surfaces indicated accuracy and clinical acceptability. Precision and trueness were also determined. Root mean square and percent of points within the tolerance level were calculated for precision and trueness for each retainer. Statistical significance was set at P <0.05. RESULTS: Interrater correlation coefficient indicated good agreement. Statistically significant differences were found between printer types among the 6 landmarks and the arch width measurements. When evaluating tolerance level and root mean square, statistically significant differences in median precision and trueness among each printer type were found. CONCLUSION: Retainers fabricated by SLA, DLP, continuous DLP, and PPP technologies were shown to be clinically acceptable and accurate compared to the standard reference file. Based on both high precision and trueness, SLA and PPP printers yielded the most accurate retainers.


Assuntos
Modelos Dentários , Impressão Tridimensional , Humanos , Contenções Ortodônticas , Software , Estereolitografia
16.
J Oral Implantol ; 48(6): 562-572, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35503961

RESUMO

Various guiding methods are used to place implants. This ex vivo pilot study used a convenience sample to examine time and accuracy for placement of 2 dental implants supporting a 3-unit fixed prosthesis on a simulation model using freehand and 3 guided placement techniques. Four operators with no prior implant placement experiences were randomly assigned placement of 2 maxillary or mandibular implants for a fixed prosthesis. Techniques included dynamic navigation (DN), static guide (SG), template-based guide (TBG), and freehand placement (FH). Preoperative and operative times were recorded. Discrepancies between the planned and placed implant positions were assessed by superimposing preoperative and postoperative cone beam computerized tomography scans. Data were analyzed with repeated-measures regression with Tukey's adjusted pairwise comparisons (α = 0.05). Dynamic navigation was associated with the longest operative time (13.5 minutes vs 5-10.2, P = .0001) but overall fastest when incorporating preoperative time (32.1 minutes vs 143-181.5, P < .0001). All deviation measures were significantly associated with the placement method (P < .05) except apex vertical deviation (P = .3925). Implants placed by SG had significantly lower entry 2-dimensional deviation than the other methods, particularly on the mandible. The DN and SG methods had significantly lower Apex 3D and overall angle deviations, again particularly on the mandible. The mandible had significantly higher deviations than maxilla. Within limitations of this study, implant placement by novice operators is more accurate when using dynamic and static guidance compared to freehand and template-based techniques.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Prótese Parcial Fixa , Imageamento Tridimensional , Projetos Piloto , Cirurgia Assistida por Computador/métodos
17.
J Oral Implantol ; 47(3): 199-204, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32780820

RESUMO

The aim of this randomized in vitro study was to compare the time and accuracy of implant-site preparation and implant placement using a trephine drill versus a conventional drilling technique under dynamic navigation. In total, 42 implants were placed in simulation jaw models with the 2 drilling techniques by 2 operators who had previous experience with dynamic navigation. The timing of each implant placement was recorded, and horizontal, vertical, and angulation discrepancies between the planned and placed implants were compared. There was no significant difference in time or accuracy between the trephine and conventional drilling techniques. Implant-site preparation with a single trephine drill using dynamic navigation was as accurate under in vitro experimental conditions as a conventional drilling sequence.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Implantação Dentária Endóssea
18.
J Oral Maxillofac Surg ; 78(2): 275-283, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31574260

RESUMO

PURPOSE: Studies have shown that an asymmetrical smile is a relatively common problem. Yet, many patients are unaware of having this condition. Because having an asymmetrical smile can affect the final esthetic result of orthodontic therapy or orthognathic surgery, such patients need to be aware of the problem. The purpose of this study was to determine what amount of smile asymmetry is clinically evident to orthodontists, oral and maxillofacial surgeons (OMSs), and the lay public. MATERIALS AND METHODS: A total of 56 OMSs, 117 orthodontists, and 123 laypersons participated in the study. They were asked to view a randomly arranged series of computer-generated male and female facial photographs with the smile symmetrical or altered in 0.5-mm increments from 1 to 4 mm and to indicate whether the person had an asymmetrical smile. RESULTS: The OMSs and orthodontists were able to recognize relatively smaller amounts of asymmetry than the laypersons (2 mm vs 3 to 3.5 mm). CONCLUSIONS: Although the clinicians performed better than the laypersons, both groups were able to recognize relatively small amounts of asymmetry. Because such a condition is generally not correctable and can affect the esthetic result, patients undergoing orthodontic therapy or orthognathic surgery need to be made aware of the situation before treatment.


Assuntos
Ortodontistas , Procedimentos Cirúrgicos Ortognáticos , Atitude do Pessoal de Saúde , Estética Dentária , Feminino , Humanos , Masculino , Cirurgiões Bucomaxilofaciais , Sorriso
19.
J Prosthet Dent ; 123(6): 821-828, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31653399

RESUMO

STATEMENT OF PROBLEM: Implant guided surgery systems promise implant placement accuracy and precision beyond straightforward nonguided surgery. Recently introduced in-office stereolithography systems allow clinicians to produce implant surgical guides themselves. However, different implant designs and osteotomy preparation protocols may produce accuracy and precision differences among the different implant systems. PURPOSE: The purpose of this in vitro study was to measure the accuracy and precision of 3 implant systems, Tapered Internal implant system (BioHorizons) (BH), NobelReplace Conical (Nobel Biocare) (NB), and Tapered Screw-Vent (Zimmer Biomet) (ZB) when in-office fabricated surgical guides were used. MATERIAL AND METHODS: A cone beam computed tomography (CBCT) data set of an unidentified patient missing a maxillary right central incisor and intraoral scans of the same patient were used as a model. A software program (3Shape Implant Studio) was used to plan the implant treatment with the 3 implant systems. Three implant surgical guides were fabricated by using a 3D printer (Form 2), and 30 casts were printed. A total of 10 implants for each system were placed in the dental casts by using the manufacturer's recommended guided surgery protocols. After implant placement, postoperative CBCT images were made. The CBCT cast and implant images were superimposed onto the treatment-planning image. The implant positions, mesiodistal, labiopalatal, and vertical, as well as implant angulations were measured in the labiolingual and mesiodistal planes. The displacements from the planning in each dimension were recorded. ANOVA with the Tukey adjusted post hoc pairwise comparisons were used to examine the accuracy and precision of the 3 implant systems (α=.05). RESULTS: The overall implant displacements were -0.02 ±0.13 mm mesially (M), 0.07 ±0.14 mm distally (D), 0.43 ±0.57 mm labially (L), and 1.26 ±0.80 mm palatally (P); 1.20 ±3.01 mm vertically in the mesiodistal dimension (VMD); 0.69 ±2.03 mm vertically in the labiopalatal dimension (VLP); 1.69 ±1.02 degrees in mesiodistal angulation (AMD); and 1.56 ±0.92 degrees in labiopalatal angulation (ALP). Statistically significant differences (ANOVA) were found in M (P=.026), P (P=.001), VMD (P=.009), AMD (P=.001), and ALP (P=.001). ZB showed the most displacements in the M and vertical dimensions and the least displacements in the P angulation (P<.05), suggesting statistically significant differences among the M, VMD, VLP, AMD, and ALP. NB had the most M variation. ZB had the least P deviation. NB had the fewest vertical dimension variations but the most angulation variations. CONCLUSIONS: Dimensional and angulation displacements of guided implant systems by in-office 3D-printed fabrication were within clinically acceptable limits: <0.1 mm in M-D, 0.5 to 1 mm in L-P, and 1 to 2 degrees in angulation. However, the vertical displacement can be as much as 2 to 3 mm. Different implant guided surgery systems have strengths and weaknesses as revealed in the dimensional and angulation implant displacements.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Humanos , Imageamento Tridimensional , Impressão Tridimensional
20.
Am J Orthod Dentofacial Orthop ; 157(4): 526-532.e2, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32241359

RESUMO

INTRODUCTION: This study aimed to evaluate the factors that influence potential orthodontic patients choosing an orthodontist, general dentist, or direct-to-consumer (DTC) aligners for their treatment, and to determine the level of interest in each provider type. METHODS: An electronic survey was administered to 249 adults among the general population in the United States to determine and evaluate the level of interest in pursuing orthodontic treatment with each provider type. RESULTS: When asked their preference for provider type, 44% of respondents selected orthodontist, 34% selected DTC aligners, and 22% selected general dentist. Among respondents with the highest level of interest in pursuing orthodontic treatment, 50% selected orthodontist, and 27% selected DTC aligners (P = 0.002). For respondents with a moderate interest in pursuing treatment, only 21% selected orthodontist, and 48% selected DTC aligners (P = 0.002). The biggest perceived advantage of treatment with orthodontists was the quality of treatment, and for DTC aligners, it was convenience, followed by cost. Among adults with children, 34% selected DTC aligners for themselves, and only 16% selected DTC aligners when selecting for their children (P = 0.0001). CONCLUSIONS: There is a high level of interest among adults in pursuing treatment with both orthodontists and DTC aligners. Patients with the highest level of interest in pursuing orthodontic care tend to prefer orthodontists, whereas those with a moderate interest in pursuing treatment prefer DTC aligners. Patients tend to select orthodontists primarily because of treatment quality, whereas they select DTC aligners for convenience and then cost. Parents tend to select an orthodontist for their child's treatment, even when selecting DTC aligners for themselves.


Assuntos
Assistência Odontológica , Ortodontistas , Adulto , Criança , Humanos , Pais , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA