Antimicrob Agents Chemother ; 63(12)2019 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-31527037

RESUMO

Globally, more people die annually from tuberculosis than from any other single infectious agent. Unfortunately, there is no commercially-available vaccine that is sufficiently effective at preventing acquisition of pulmonary tuberculosis in adults. In this study, pre-exposure prophylactic pulmonary delivery of active aerosolized anti-tuberculosis bacteriophage D29 was evaluated as an option for protection against Mycobacterium tuberculosis infection. An average bacteriophage concentration of approximately 1 PFU/alveolus was achieved in the lungs of mice using a nose-only inhalation device optimized with a dose simulation technique and adapted for use with a vibrating mesh nebulizer. Within 30 minutes of bacteriophage delivery, the mice received either a low dose (∼50-100 CFU), or an ultra-low dose (∼5-10 CFU), of M. tuberculosis H37Rv aerosol to the lungs. A prophylactic effect was observed with bacteriophage aerosol pre-treatment significantly decreasing M. tuberculosis burden in mouse lungs 24 hours and 3 weeks post-challenge (p < 0.05). These novel results indicate that a sufficient dose of nebulized mycobacteriophage aerosol to the lungs may be a valuable intervention to provide extra protection to health care professionals and other individuals at risk of exposure to M. tuberculosis.

2.
Pharm Res ; 34(10): 2084-2096, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28646325

RESUMO

PURPOSE: To compare titer reduction and delivery rate of active anti-tuberculosis bacteriophage (phage) D29 with three inhalation devices. METHODS: Phage D29 lysate was amplified to a titer of 11.8 ± 0.3 log10(pfu/mL) and diluted 1:100 in isotonic saline. Filters captured the aerosolized saline D29 preparation emitted from three types of inhalation devices: 1) vibrating mesh nebulizer; 2) jet nebulizer; 3) soft mist inhaler. Full-plate plaque assays, performed in triplicate at multiple dilution levels with the surrogate host Mycobacterium smegmatis, were used to quantify phage titer. RESULTS: Respective titer reductions for the vibrating mesh nebulizer, jet nebulizer, and soft mist inhaler were 0.4 ± 0.1, 3.7 ± 0.1, and 0.6 ± 0.3 log10(pfu/mL). Active phage delivery rate was significantly greater (p < 0.01) for the vibrating mesh nebulizer (3.3x108 ± 0.8x108 pfu/min) than for the jet nebulizer (5.4x104 ± 1.3x104 pfu/min). The soft mist inhaler delivered 4.6x106 ± 2.0x106 pfu per 11.6 ± 1.6 µL ex-actuator dose. CONCLUSIONS: Delivering active phage requires a prudent choice of inhalation device. The jet nebulizer was not a good choice for aerosolizing phage D29 under the tested conditions, due to substantial titer reduction likely occurring during droplet production. The vibrating mesh nebulizer is recommended for animal inhalation studies requiring large amounts of D29 aerosol, whereas the soft mist inhaler may be useful for self-administration of D29 aerosol.


Assuntos
Bacteriófagos , Nebulizadores e Vaporizadores , Tuberculose/terapia , Administração por Inalação , Aerossóis/química , Animais , Liberação Controlada de Fármacos , Estabilidade de Medicamentos , Desenho de Equipamento/métodos , Equipamentos e Provisões , Humanos , Terapia por Fagos
3.
Pharm Res ; 33(6): 1486-96, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26928668

RESUMO

PURPOSE: The potential of aerosol phage therapy for treating lung infections has been demonstrated in animal models and clinical studies. This work compared the performance of two dry powder formation techniques, spray freeze drying (SFD) and spray drying (SD), in producing inhalable phage powders. METHOD: A Pseudomonas podoviridae phage, PEV2, was incorporated into multi-component formulation systems consisting of trehalose, mannitol and L-leucine (F1 = 60:20:20 and F2 = 40:40:20). The phage titer loss after the SFD and SD processes and in vitro aerosol performance of the produced powders were assessed. RESULTS: A significant titer loss (~2 log) was noted for droplet generation using an ultrasonic nozzle employed in the SFD method, but the conventional two-fluid nozzle used in the SD method was less destructive for the phage (~0.75 log loss). The phage were more vulnerable during the evaporative drying process (~0.75 log further loss) compared with the freeze drying step, which caused negligible phage loss. In vitro aerosol performance showed that the SFD powders (~80% phage recovery) provided better phage protection than the SD powders (~20% phage recovery) during the aerosolization process. Despite this, higher total lung doses were obtained for the SD formulations (SD-F1 = 13.1 ± 1.7 × 10(4) pfu and SD-F2 = 11.0 ± 1.4 × 10(4) pfu) than from their counterpart SFD formulations (SFD-F1 = 8.3 ± 1.8 × 10(4) pfu and SFD-F2 = 2.1 ± 0.3 × 10(4) pfu). CONCLUSION: Overall, the SD method caused less phage reduction during the powder formation process and the resulted powders achieved better aerosol performance for PEV2.


Assuntos
Liofilização/métodos , Pulmão/virologia , Terapia por Fagos/métodos , Podoviridae/patogenicidade , Infecções por Pseudomonas/terapia , Pseudomonas/virologia , Infecções Respiratórias/terapia , Administração por Inalação , Aerossóis , Leucina/química , Pulmão/microbiologia , Manitol/química , Viabilidade Microbiana , Nebulizadores e Vaporizadores , Pós , Pseudomonas/patogenicidade , Infecções por Pseudomonas/microbiologia , Infecções por Pseudomonas/virologia , Infecções Respiratórias/microbiologia , Infecções Respiratórias/virologia , Trealose/química , Ultrassom
4.
J Control Release ; 336: 522-536, 2021 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-34229002

RESUMO

The formation of trileucine-containing spray-dried microparticles intended for pulmonary delivery was studied in depth. A single-particle method was employed to study the shell formation characteristics of trileucine in the presence of trehalose as a glass former, and an empirical correlation was proposed to predict the instance of shell formation. A droplet chain instrument was used to produce and collect monodisperse particles to examine morphology and calculate particle density for different levels of trileucine. It was observed that the addition of only 0.5 mg/mL (10% w/w) trileucine to a trehalose system could lower dried particle densities by approximately 1 g/cm3. In addition, a laboratory-scale spray dryer was used to produce batches of trileucine/trehalose powders in the respirable range. Raman spectroscopy demonstrated that both components were completely amorphous. Scanning electron microscopy and time-of-flight secondary ion mass spectrometry were used to study the particle morphologies and surface compositions. For all cases with trileucine, highly rugose particles with trileucine coverages of more than 60% by mass were observed with trileucine feed fractions of as little as 2% w/w. Moreover, it was seen that at lower trileucine content, smaller and larger particles of a polydisperse powder had slightly different surface compositions. The surface activity of trileucine was also modeled via a modified form of the diffusion equation inside an evaporating droplet that took into account initial surface adsorption and eventual surface desorption due to droplet shrinkage. Finally, using the Flory-Huggins theory, it was estimated that at room temperature, liquid-liquid phase separation would start when the trileucine reached an aqueous concentration of about 18 mg/mL. Besides the surface activity of trileucine, this low concentration was assumed to explain the substantial effect of trileucine on the morphology of spray-dried particles due to early phase separation. The methodology proposed in this study can be used in the rational design of trileucine-containing microparticles.


Assuntos
Oligopeptídeos , Administração por Inalação , Aerossóis , Tamanho da Partícula , Pós
5.
Adv Drug Deliv Rev ; 176: 113864, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34271022

RESUMO

Bacteriophages (Phages) are antibacterial viruses that are unaffected by antibiotic drug resistance. Many Phase I and Phase II phage therapy clinical trials have shown acceptable safety profiles. However, none of the completed trials could yield data supporting the promising observations noted in the experimental phage therapy. These trials have mainly focused on phage suspensions without enough attention paid to the stability of phage during processing, storage, and administration. This is important because in vivo studies have shown that the effectiveness of phage therapy greatly depends on the ratio of phage to bacterial concentrations (multiplicity of infection) at the infection site. Additionally, bacteria can evade phages through the development of phage-resistance and intracellular residence. This review focuses on the use of phage therapy against bacteria that survive within the intracellular niches. Recent research on phage behavior reveals that some phage can directly interact with, get internalized into, and get transcytosed across mammalian cells, prompting further research on the governing mechanisms of these interactions and the feasibility of harnessing therapeutic phage to target intracellular bacteria. Advances to improve the capability of phage attacking intracellular bacteria using formulation approaches such as encapsulating/conjugating phages into/with vector carriers via liposomes, polymeric particles, inorganic nanoparticles, and cell penetrating peptides, are summarized. While promising progress has been achieved, research in this area is still in its infancy and warrants further attention.


Assuntos
Infecções Bacterianas/terapia , Terapia por Fagos , Animais , Bacteriófagos , Humanos
6.
Eur J Pharm Biopharm ; 163: 23-37, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33753213

RESUMO

Spray drying is a technique that can be used to stabilize biopharmaceuticals, such as vaccines, within dry particles. Compared to liquid pharmaceutical products, dry powder has the potential to reduce costs associated with refrigerated storage and transportation. In this study, spray drying was investigated for processing an adjuvanted tuberculosis subunit vaccine, formulated as an oil-in-water nanoemulsion, into a dry powder composed of microparticles. Applying in-silico approaches to the development of formulation and processing conditions, successful encapsulation of the adjuvanted vaccine within amorphous microparticles was achieved in only one iteration, with high retention (>90%) of both the antigen and adjuvant system. Moisture-controlled stability studies on the powder were conducted over 26 months at temperatures up to 40 °C. Results showed that the powder was physically stable after 26 months of storage for all tested temperatures. Adjuvant system integrity was maintained at temperatures up to 25 °C after 26 months and after one month of storage at 40 °C. The spray-dried product demonstrated improved antigen thermostability when stored above refrigerated temperatures as compared to the liquid product. These results demonstrate the feasibility of spray drying as a method of encapsulating and stabilizing an adjuvanted vaccine.


Assuntos
Adjuvantes Imunológicos/química , Composição de Medicamentos/métodos , Secagem por Atomização , Vacinas contra a Tuberculose/química , Tuberculose/prevenção & controle , Adjuvantes Imunológicos/administração & dosagem , Química Farmacêutica , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Emulsões , Excipientes , Humanos , Nanopartículas/química , Tamanho da Partícula , Pós , Vacinas contra a Tuberculose/administração & dosagem , Vacinas de Subunidades Antigênicas/administração & dosagem
7.
Int J Pharm ; 593: 120121, 2021 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-33278492

RESUMO

Protection against primarily respiratory infectious diseases, such as tuberculosis (TB), can likely be enhanced through mucosal immunization induced by direct delivery of vaccines to the nose or lungs. A thermostable inhalable dry powder vaccine offers further advantages, such as independence from the cold chain. In this study, we investigate the formulation for a stable, inhalable dry powder version of ID93 + GLA-SE, an adjuvanted subunit TB vaccine candidate, containing recombinant fusion protein ID93 and glucopyranosyl lipid A (GLA) in a squalene emulsion (SE) as an adjuvant system, via spray drying. The addition of leucine (20% w/w), pullulan (10%, 20% w/w), and trileucine (3%, 6% w/w) as dispersibility enhancers was investigated with trehalose as a stabilizing agent. Particle morphology and solid state, nanoemulsion droplet size, squalene and GLA content, ID93 presence, and aerosol performance were assessed for each formulation. The results showed that the addition of leucine improved aerosol performance, but increased aggregation of the emulsion droplets was demonstrated on reconstitution. Addition of pullulan preserved emulsion droplet size; however, the antigen could not be detected after reconstitution. The trehalose-trileucine excipient formulations successfully stabilized the adjuvant system, with evidence indicating retention of the antigen, in an inhalable dry powder format suitable for lung delivery.


Assuntos
Vacinas contra a Tuberculose , Tuberculose , Adjuvantes Imunológicos , Administração por Inalação , Aerossóis , Excipientes , Humanos , Tamanho da Partícula , Pós
8.
Front Pharmacol ; 12: 799034, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35126135

RESUMO

Converting a vaccine into a thermostable dry powder is advantageous as it reduces the resource burden linked with the cold chain and provides flexibility in dosage and administration through different routes. Such a dry powder presentation may be especially useful in the development of a vaccine towards the respiratory infectious disease tuberculosis (TB). This study assesses the immunogenicity and protective efficacy of spray-dried ID93+GLA-SE, a promising TB vaccine candidate, against Mycobacterium tuberculosis (Mtb) in a murine model when administered via different routes. Four administration routes for the spray-dried ID93+GLA-SE were evaluated along with relevant controls-1) reconstitution and intramuscular injection, 2) reconstitution and intranasal delivery, 3) nasal dry powder delivery via inhalation, and 4) pulmonary dry powder delivery via inhalation. Dry powder intranasal and pulmonary delivery was achieved using a custom nose-only inhalation device, and optimization using representative vaccine-free powder demonstrated that approximately 10 and 44% of the maximum possible delivered dose would be delivered for intranasal delivery and pulmonary delivery, respectively. Spray-dried powder was engineered according to the different administration routes including maintaining approximately equivalent delivered doses of ID93 and GLA. Vaccine properties of the different spray-dried lots were assessed for quality control in terms of nanoemulsion droplet diameter, polydispersity index, adjuvant content, and antigen content. Our results using the Mtb mouse challenge model show that both intranasal reconstituted vaccine delivery as well as pulmonary dry powder vaccine delivery resulted in Mtb control in infected mice comparable to traditional intramuscular delivery. Improved protection in these two vaccinated groups over their respective control groups coincided with the presence of cytokine-producing T cell responses. In summary, our results provide novel vaccine formulations and delivery routes that can be harnessed to provide protection against Mtb infection.

9.
Microorganisms ; 8(2)2020 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-32093083

RESUMO

Bacteriophages are a sustainable alternative to control pathogenic bacteria in the post-antibiotic era. Despite promising reports, there are still obstacles to phage use, notably titer stability and transport-associated expenses for applications in food and agriculture. In this study, we have developed a lyophilization approach to maintain phage titers, ensure efficacy and reduce transport costs of Campylobacter bacteriophages. Lyophilization methods were adopted with various excipients to enhance stabilization in combination with packaging options for international transport. Lyophilization of Eucampyvirinae CP30A using tryptone formed a cake that limited processing titer reduction to 0.35 ± 0.09 log10 PFU mL-1. Transmission electron microscopy revealed the initial titer reduction was associated with capsid collapse of a subpopulation. Freeze-dried phages were generally stable under refrigerated vacuum conditions and showed no significant titer changes over 3 months incubation at 4 °C (p = 0.29). Reduced stability was observed for lyophilized phages that were incubated either at 30 °C under vacuum or at 4 °C at 70% or 90% relative humidity. Refrigerated international transport and rehydration of the cake resulted in a total phage titer reduction of 0.81 ± 0.44 log10 PFU mL-1. A significantly higher titer loss was observed for phages that were not refrigerated during transport (2.03 ± 0.32 log10 PFU mL-1). We propose that lyophilization offers a convenient method to preserve and transport Campylobacter phages, with minimal titer reduction after the drying process.

10.
Ann Biomed Eng ; 48(4): 1169-1180, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31845128

RESUMO

Spray drying biologics into a powder can increase thermal stability and shelf-life relative to liquid formulations, potentially eliminating the need for cold chain infrastructure for distribution in developing countries. In this study, process modelling, microparticle engineering, and a supplemented phase diagram were used to design physically stable fully amorphous spray-dried powder capable of stabilizing biological material. A greater proportion of anti-Campylobacter bacteriophage CP30A remained biologically active after spray drying using excipient formulations containing trehalose and a high glass transition temperature amorphous shell former, either trileucine or pullulan, as compared to the commonly used crystalline shell former, leucine, or a low glass transition temperature amorphous shell former, pluronic F-68. Particle formation models suggest that the stabilization was achieved by protecting the bacteriophages against the main inactivating stress, desiccation, at the surface. The most promising formulation contained a combination of trileucine and trehalose for which the combined effects of feedstock preparation, spray drying, and 1-month dry room temperature storage resulted in a titer reduction of only 0.6 ± 0.1 log10(PFU mL-1). The proposed high glass transition temperature amorphous formulation platform may be advantageous for stabilizing biologics in other spray drying applications in the biomedical engineering industry.


Assuntos
Bacteriófagos , Campylobacter/virologia , Glucanos , Oligopeptídeos , Dessecação , Excipientes , Pós , Temperatura , Trealose , Vitrificação
11.
Front Microbiol ; 10: 488, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30949139

RESUMO

Therapeutic bacteriophages offer a potential alternative approach in the treatment of drug resistant bacteria. In the present study, we examine the ability of atmospheric spray freeze-drying (ASFD) to process bacteriophage D29 into a solid dry formulation. Bacteriophage D29 is of particular interest due to its ability to infect Mycobacterium tuberculosis. A sugar solution containing bacteriophage D29 was sprayed and instantly frozen in a cold chamber. Cold drying gas was then passed through the chamber at a high flow rate and atmospheric pressure. Convective transport combined with the low temperature of the drying gas results in sublimation of ice, yielding a free-flowing, porous powder. The bacteriophages were atmospheric spray freeze-dried in solutions with varying concentrations of trehalose and mannitol. A solution of trehalose and mannitol at a mass ratio of 7:3 and a total mass concentration of 100 mg/mL led to powder with 4.9 ± 0.1% moisture content and an acceptable titer reduction of ∼0.6 logs. In comparison, a pure trehalose solution and a 1:1 ratio of trehalose and mannitol both had titer reductions of >1.5 logs. Spectroscopic analysis showed that trehalose in the powder was amorphous while mannitol completely crystallized during the drying process, both of which are desirable for preserving phage viability and storage in powders. The results highlight the potential for using ASFD as an alternative process in preserving biopharmaceutical products.

12.
Int J Pharm ; 569: 118601, 2019 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-31394183

RESUMO

Campylobacter jejuni is a leading cause of foodborne illness globally. In this study, a spray drying and packaging process was developed to produce a thermally-stable dry powder containing bacteriophages that retains biological activity against C. jejuni after long distance shipping at ambient temperature. Spray drying using a twin-fluid atomizer resulted in significantly less (p < 0.05) titer reduction than spray drying using a vibrating mesh nebulizer. The use of centrifugation and dilution of filtered bacteriophage lysate in the formulation step resulted in a significantly greater (p < 0.05) proportion of bacteriophages remaining active relative to use of no centrifugation and dilution. The spray-dried bacteriophage powder generated using leucine and trehalose as excipients was flowable, non-cohesive, and exhibited a high manufacturing yield. The powder retained its titer with no significant differences (p > 0.05) in biological activity after storage in suitable packaging for at least 3 weeks at room temperature and after ambient temperature shipping a total distance of approximately 19,800 km, including with a 38 °C temperature excursion. The bacteriophage powder therefore appears suitable for global distribution without the need for cold chain infrastructure.


Assuntos
Bacteriófagos , Campylobacter/virologia , Química Farmacêutica , Dessecação , Excipientes/química , Leucina/química , Pós , Trealose/química
13.
Int J Pharm ; 554: 322-326, 2019 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-30445174

RESUMO

It was previously demonstrated that the loss of infectivity of a myovirus PEV44 after jet nebulization was closely related to a change in bacteriophage (phage) structure. In this follow-up study, we further examined the impact of jet nebulization on tailed phages, which constitute 96% of all known phages, from three different families, Podoviridae (PEV2), Myoviridae (PEV40) andSiphoviridae (D29). Transmission electron microscopy (TEM) identified major changes in phage structures after jet nebulization, correlating with their loss of infectivity. For the podovirus PEV2, jet nebulization had a negligible impact on its activity (0.04 log10 pfu/mL loss) and structural change. On the other hand, the proportion of intact phages in the nebulized samples dropped from 50% to ∼27% for PEV40 and from 15% to ∼2% for D29. Phage deactivation of PEV40 measured by the TEM structural damage (0.52 log10 pfu/mL) was lower than that obtained by plaque assay (1.02 log10 pfu/mL), but within the range of variation (±0.5 log10 pfu/mL). However, TEM quantification considerably underestimated the titer reduction of D29 phage, ∼2 log pfu/mL lower than that obtained in plaque assay (3.25 log10 pfu/mL loss). In conclusion, nebulization-induced titre loss was correlated with morphological damage to phages and in particular, the tail length may be an important consideration for selection of phages in inhaled therapy using jet nebulization.


Assuntos
Bacteriófagos/química , Myoviridae/química , Podoviridae/química , Siphoviridae/química , Bacteriófagos/fisiologia , Microscopia Eletrônica de Transmissão , Myoviridae/fisiologia , Nebulizadores e Vaporizadores , Podoviridae/fisiologia , Siphoviridae/fisiologia
14.
Int J Pharm ; 563: 156-168, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-30951858

RESUMO

Spray drying biologics and small-molecule drugs can increase their thermal stability relative to liquid dosage forms and allow for widespread distribution to developing countries without cold chain infrastructure. In this study, pullulan trehalose powder is spray dried for inhalation. The powder is characterized in terms of manufacturability, physical stability, device compatibility, and aerosol performance. The manufacturability is demonstrated by reasonable spray drying yield and powder flowability. The powder has relatively low cohesiveness and high compressibility without semi-elastic deformation. Short-term physical stability for ambient temperature dry storage and 40 °C storage in commercial pressurized metered-dose inhaler propellants HFA 134a and HFA 227 is shown. A theoretical model predicts a high glass transition temperature near the surface of the microparticles where biologics are expected to reside. Emission from a commercial dry powder inhaler demonstrates high dispersibility, optimal size for inhalation, and adequate total lung dose, exceeding many commercial inhalation devices. The powder can be filled, stored, and actuated from a pressurized metered-dose inhaler without changes in particle morphology or solid phase. The pullulan trehalose platform thus appears promising for respiratory delivery.


Assuntos
Glucanos/química , Trealose/química , Administração por Inalação , Propelentes de Aerossol , Aerossóis , Dessecação , Estabilidade de Medicamentos , Inaladores de Pó Seco , Hidrocarbonetos Fluorados , Inaladores Dosimetrados , Pós , Temperatura de Transição , Vitrificação
15.
Eur J Pharm Biopharm ; 127: 213-222, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29486303

RESUMO

This study aimed to assess the robustness of using a spray drying approach and formulation design in producing inhalable phage powders. Two types of Pseudomonas phages, PEV2 (Podovirus) and PEV40 (Myovirus) in two formulations containing different amounts of trehalose (70% and 60%) and leucine (30% and 40%) were studied. Most of the surface of the produced powders was found to be covered in crystalline leucine. The powders were stored at 4 °C and 20 °C under vacuum. The phage stability and in vitro aerosol performance of the phage powders were examined on the day of production and after 1, 3 and 12 months of storage. A minor titer loss during production was observed for both phages (0.2-0.8 log10 pfu/ml). The storage stability of the produced phage powders was found to be phage and formulation dependent. No further reduction in titer occurred for PEV2 powders stored at 4 °C across the study. The formulation containing 30% leucine maintained the viability of PEV2 at 20 °C, while the formulation containing 40% leucine gradually lost titer over time with a storage reduction of ∼0.9 log10 pfu/ml measured after 12 months. In comparison, the PEV40 phage powders generally had a ∼ 0.5 log10 pfu/ml loss upon storage regardless of temperature. When aerosolized, the total in vitro lung doses of PEV2 were of the order of 107 pfu, except the formulation containing 40% leucine stored at 20 °C which had a lower lung dose. The PEV40 powders also had lung doses of 106-107 pfu. The results demonstrate that spray dried Myoviridae and Podoviridae phage in a simple formulation of leucine and trehalose can be successfully stored for one year at 4 °C and 20 °C with vacuum packaging.


Assuntos
Bacteriófagos/química , Pós/química , Administração por Inalação , Aerossóis/química , Química Farmacêutica/métodos , Dessecação/métodos , Estabilidade de Medicamentos , Inaladores de Pó Seco/métodos , Excipientes/química , Pulmão/efeitos dos fármacos , Tamanho da Partícula , Temperatura , Trealose/química
16.
Int J Pharm ; 521(1-2): 141-149, 2017 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-28163231

RESUMO

This study aimed to develop inhalable powders containing phages active against antibiotic-resistant Pseudomonas aeruginosa for pulmonary delivery. A Pseudomonas phage, PEV2, was spray dried into powder matrices comprising of trehalose (0-80%), mannitol (0-80%) and l-leucine (20%). The resulting powders were stored at various relative humidity (RH) conditions (0, 22 and 60% RH) at 4°C. The phage stability and in vitro aerosol performance of the phage powders were examined at the time of production and after 1, 3 and 12 months storage. After spray drying, a total of 1.3 log titer reduction in phage was observed in the formulations containing 40%, 60% and 80% trehalose, whereas 2.4 and 5.1 log reductions were noted in the formulations containing 20% and no trehalose, respectively. No further reduction in titer occurred for powders stored at 0 and 22% RH even after 12 months, except the formulation containing no trehalose. The 60% RH storage condition had a destructive effect such that no viable phages were detected after 3 and 12 months. When aerosolised, the total lung doses for formulations containing 40%, 60% and 80% trehalose were similar (in the order of 105 pfu). The results demonstrated that spray drying is a suitable method to produce stable phage powders for pulmonary delivery. A powder matrix containing ≥40% trehalose provided good phage preservation and aerosol performances after storage at 0 and 22% RH at 4°C for 12 months.


Assuntos
Bacteriófagos/química , Dessecação , Pseudomonas aeruginosa/química , Administração por Inalação , Cristalização , Dessecação/métodos , Estabilidade de Medicamentos , Armazenamento de Medicamentos/métodos , Umidade/efeitos adversos , Tamanho da Partícula , Pós , Pseudomonas aeruginosa/fisiologia , Difração de Raios X
17.
Artigo em Inglês | MEDLINE | ID: mdl-26213804

RESUMO

Quantifying the contribution of passive mechanical deformation in the human pharynx to upper airway collapse is fundamental to understanding the competing biomechanical processes that maintain airway patency. This study uses finite element analysis to examine deformation in the passive human pharynx using an intricate 3D anatomical model based on computed tomography scan images. Linear elastic properties are assigned to bone, cartilage, ligament, tendon, and membrane structures based on a survey of values reported in the literature. Velopharyngeal and oropharyngeal cross-sectional area versus airway pressure slopes are determined as functions of Young's moduli of muscle and adipose tissue. In vivo pharyngeal mechanics for small deformations near atmospheric pressure are matched by altering Young's moduli of muscle and adipose tissue. The results indicate that Young's moduli ranging from 0.33 to 14 kPa for muscle and adipose tissue matched the in vivo range of area versus pressure slopes. The developed anatomical model and determined Young's moduli range are expected to be useful as a starting point for more complex simulations of human upper airway collapse and obstructive sleep apnea therapy.


Assuntos
Tecido Adiposo/fisiologia , Simulação por Computador , Músculos/fisiologia , Faringe/fisiologia , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Modelos Anatômicos , Modelos Biológicos
18.
Curr Pharm Des ; 21(27): 3984-92, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26290196

RESUMO

The lung dose of inhaled pharmaceutical aerosol that an individual will receive from an inhaler can now be more accurately estimated in light of recent extrathoracic deposition modeling that has correlated characteristic airway dimensions with deposition. This paper first summarizes the current state of extrathoracic deposition models, including recent developments that have quantified the effects of aerosol electrostatics and inhaler mouthpiece diameter on deposition. A generalized equation for predicting extrathoracic deposition in different subjects is then developed and average characteristic airway dimensions representative of different age groups are indicated. A methodology is then presented to predict the lung dose per unit body surface area individuals will receive from an inhaler. A sample calculation shows that a typical 10-year-old child subject would receive a lower lung dose per unit body surface area than an adult subject inhaling through the same inhaler at the same 90 L min-1 flow rate, due to greater extrathoracic deposition in the child. In order to provide an equivalent lung dose per unit body surface area to the child as to the adult, an inhaler particle size adjustment is specified. Finally, the use of idealized geometries for developing inhaler-specific empirical correlations and improving upon inhaler design is outlined.


Assuntos
Desenho Assistido por Computador , Laringe/fisiopatologia , Pneumopatias/fisiopatologia , Modelos Teóricos , Nebulizadores e Vaporizadores , Preparações Farmacêuticas/administração & dosagem , Traqueia/fisiopatologia , Administração por Inalação , Adulto , Relação Dose-Resposta a Droga , Desenho de Equipamento , Humanos , Laringe/efeitos dos fármacos , Pneumopatias/tratamento farmacológico , Traqueia/efeitos dos fármacos
19.
J Aerosol Med Pulm Drug Deliv ; 28(6): 452-61, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25844950

RESUMO

BACKGROUND: Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which does not require any inhalation training from the pediatric subject, is reported here. It uses an external source of compressed air to disperse mannitol powder into a commercial holding chamber. Then the subject uses tidal breathing to inhale the aerosol. METHOD: The setup consists of a commercially available powder disperser and Volumatic™ holding chamber. Taguchi experimental design was used to identify the effect of dispersion parameters (flow rate of compressed air, time compressed air is applied, mass of powder, and the time between dispersion and inhalation) on the fine particle dose (FPD). The prototype was tested in vitro using a USP throat connected to a next generation impactor. The aerosols from the holding chamber were drawn at 10 L/min. A scaling factor for estimating the provoking dose to induce a 15% reduction in forced expiratory volume in 1 second (FEV1) (PD15) was calculated using anatomical dimensions of the human respiratory tract at various ages combined with known dosing values from the adult BPT. RESULTS: Consistent and doubling FPDs were successfully generated based on the Taguchi experimental design. The FPD was reliable over a range of 0.8 (±0.09) mg to 14 (±0.94) mg. The calculated PD15 for children aged 1-6 years ranged from 7.1-30 mg. The FPDs generated from the proposed set up are lower than the calculated PD15 and therefore are not expected to cause sudden bronchoconstriction. CONCLUSION: A prototype aerosol delivery system has been developed that is consistently able to deliver doubling doses suitable for bronchial provocation testing in young children.


Assuntos
Asma/diagnóstico , Testes de Provocação Brônquica , Broncoconstritores/administração & dosagem , Sistemas de Liberação de Medicamentos/instrumentação , Manitol/administração & dosagem , Nebulizadores e Vaporizadores , Administração por Inalação , Aerossóis , Fatores Etários , Asma/fisiopatologia , Broncoconstritores/química , Química Farmacêutica , Pré-Escolar , Desenho de Equipamento , Humanos , Lactente , Manitol/química , Modelos Anatômicos , Modelos Biológicos , Pós , Valor Preditivo dos Testes , Respiração , Sistema Respiratório/crescimento & desenvolvimento , Sistema Respiratório/fisiopatologia
20.
J Aerosol Med Pulm Drug Deliv ; 27(3): 149-69, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24870701

RESUMO

Respiratory tract deposition models provide a useful method for optimizing the design and administration of inhaled pharmaceutical aerosols, and can be useful for estimating exposure risks to inhaled particulate matter. As aerosol must first pass through the extrathoracic region prior to reaching the lungs, deposition in this region plays an important role in both cases. Compared to adults, much less extrathoracic deposition data are available with pediatric subjects. Recently, progress in magnetic resonance imaging and computed tomography scans to develop pediatric extrathoracic airway replicas has facilitated addressing this issue. Indeed, the use of realistic replicas for benchtop inhaler testing is now relatively common during the development and in vitro evaluation of pediatric respiratory drug delivery devices. Recently, in vitro empirical modeling studies using a moderate number of these realistic replicas have related airway geometry, particle size, fluid properties, and flow rate to extrathoracic deposition. Idealized geometries provide a standardized platform for inhaler testing and exposure risk assessment and have been designed to mimic average in vitro deposition in infants and children by replicating representative average geometrical dimensions. In silico mathematical models have used morphometric data and aerosol physics to illustrate the relative importance of different deposition mechanisms on respiratory tract deposition. Computational fluid dynamics simulations allow for the quantification of local deposition patterns and an in-depth examination of aerosol behavior in the respiratory tract. Recent studies have used both in vitro and in silico deposition measurements in realistic pediatric airway geometries to some success. This article reviews the current understanding of pediatric in vitro and in silico deposition modeling via oral and nasal inhalation.


Assuntos
Simulação por Computador , Modelos Anatômicos , Preparações Farmacêuticas/administração & dosagem , Sistema Respiratório/anatomia & histologia , Administração por Inalação , Administração Intranasal , Administração Oral , Aerossóis , Fatores Etários , Criança , Pré-Escolar , Desenho Assistido por Computador , Desenho de Equipamento , Feminino , Humanos , Lactente , Exposição por Inalação/efeitos adversos , Masculino , Nebulizadores e Vaporizadores , Tamanho da Partícula , Material Particulado/efeitos adversos , Preparações Farmacêuticas/química , Sistema Respiratório/crescimento & desenvolvimento , Reologia , Medição de Risco