Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Aging Clin Exp Res ; 35(4): 763-773, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36752950

RESUMO

BACKGROUND: Accurate estimation of the imminent fragility fracture risk currently represents a challenging task. The novel Fragility Score (FS) parameter, obtained during a Radiofrequency Echographic Multi Spectrometry (REMS) scan of lumbar or femoral regions, has been developed for the non-ionizing estimation of skeletal fragility. AIMS: The aim of this study was to assess the performance of FS in the early identification of patients at risk for incident fragility fractures with respect to bone mineral density (BMD) measurements. METHODS: Data from 1989 Caucasians of both genders were analysed and the incidence of fractures was assessed during a follow-up period up to 5 years. The diagnostic performance of FS to discriminate between patients with and without incident fragility fracture in comparison to that of the BMD T-scores measured by both Dual X-ray Absorptiometry (DXA) and REMS was assessed through ROC analysis. RESULTS: Concerning the prediction of generic osteoporotic fractures, FS provided AUC = 0.811 for women and AUC = 0.780 for men, which resulted in AUC = 0.715 and AUC = 0.758, respectively, when adjusted for age and body mass index (BMI). For the prediction of hip fractures, the corresponding values were AUC = 0.780 for women and AUC = 0.809 for men, which became AUC = 0.735 and AUC = 0.758, respectively, after age- and BMI-adjustment. Overall, FS showed the highest prediction ability for any considered fracture type in both genders, resulting always being significantly higher than either T-scores, whose AUC values were in the range 0.472-0.709. CONCLUSION: FS displayed a superior performance in fracture prediction, representing a valuable diagnostic tool to accurately detect a short-term fracture risk.


Assuntos
Fraturas do Quadril , Fraturas por Osteoporose , Feminino , Humanos , Masculino , Densidade Óssea , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Absorciometria de Fóton/métodos , Fraturas do Quadril/epidemiologia , Análise Espectral
2.
Respir Med ; 189: 106644, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34653873

RESUMO

OBJECTIVE: To assess the effectiveness of 3 novel lung ultrasound (LUS)-based parameters: Pneumonia Score and Lung Staging for pneumonia staging and COVID Index, indicating the probability of SARS-CoV-2 infection. METHODS: Adult patients admitted to the emergency department with symptoms potentially related to pneumonia, healthy volunteers and clinical cases from online accessible databases were evaluated. The patients underwent a clinical-epidemiological questionnaire and a LUS acquisition, following a 14-zone protocol. For each zone, a Pneumonia score from 0 to 4 was assigned by the algorithm and by an expert operator (kept blind with respect to the algorithm results) on the basis of the identified imaging signs and the patient Lung Staging was derived as the highest observed score. The output of the operator was considered as the ground truth. The algorithm calculated also the COVID Index by combining the automatically identified LUS markers with the questionnaire answers and compared with the nasopharyngeal swab results. RESULTS: Overall, 556 patients were analysed. A high agreement between the algorithm assignments and the expert operator evaluations was observed, both for Pneumonia Score and Lung Staging, with the latter having sensitivity and specificity over 92% both in the discrimination between healthy/sick patients and between sick patients with mild/severe pneumonia. Regarding the COVID Index, an area under the curve of 0.826 was observed for the classification of patients with/without SARS-CoV-2. CONCLUSION: The proposed methodology allowed the identification and staging of patients suffering from pneumonia with high accuracy. Moreover, it provided the probability of being infected by SARS-CoV-2.


Assuntos
COVID-19/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Projetos de Pesquisa/normas , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/complicações , Bases de Dados Factuais , Feminino , Humanos , Doenças Pulmonares Intersticiais/classificação , Doenças Pulmonares Intersticiais/complicações , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Inquéritos e Questionários , Adulto Jovem
3.
J Mater Sci Mater Med ; 20(4): 983-9, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19052848

RESUMO

Tissue mimicking phantoms have been widely reported to be an important tool for development, optimisation and performance testing of ultrasound-based diagnostic techniques. In particular, modern applications of tissue mimicking phantoms often include characterisation of the nonlinear behaviour of experimental ultrasound contrast agents. In such cases, the tissue-mimicking materials should be chosen not only based on the values of their density, speed of sound and attenuation coefficient, but also considering their effect on the appearance of "native harmonics" due to nonlinear distortion of ultrasound signal during propagation. In a previous paper it was demonstrated that a cellulose-based hydrogel is suitable to simulate nonlinear acoustical behaviour of liver tissue for thicknesses up to 8 cm. In this paper we present the experimental characterisation of the nonlinear acoustical behaviour of a different polyethylene glycol diacrylate (PEGDA)-based hydrogel, in order to assess whether and how it can improve the performances and overcome some limitations of the cellulose-based hydrogel as liver tissue-mimicking material. Samples of pig liver tissue, cellulose-based hydrogel and PEGDA-based hydrogel were insonified in a through-transmission set-up, employing 2.25-MHz pulses with different mechanical index (MI) values. Second harmonic and first harmonic amplitudes were extracted from the spectra of received signals and their difference was then used to compare sample behaviours. Obtained results show how a new more accurate and combined experimental model of linear and nonlinear acoustical behaviour of liver tissue is feasible. In fact, a further confirmation of the cellulose-based hydrogel effectiveness to precisely simulate the liver tissue for penetration depths up to 8 cm was provided, and it was also shown that the employment of the PEGDA-based hydrogel can extend the range of useful tissue-mimicking material thicknesses up to 11 cm, moreover allowing a considerable improvement of the time stability and behaviour reliability of the corresponding manufactured phantoms.


Assuntos
Hidrogéis , Fígado , Imagens de Fantasmas , Ultrassonografia , Animais , Polietilenoglicóis , Suínos
4.
World J Orthop ; 7(3): 171-81, 2016 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-27004165

RESUMO

Osteoporosis is a silent disease without any evidence of disease until a fracture occurs. Approximately 200 million people in the world are affected by osteoporosis and 8.9 million fractures occur each year worldwide. Fractures of the hip are a major public health burden, by means of both social cost and health condition of the elderly because these fractures are one of the main causes of morbidity, impairment, decreased quality of life and mortality in women and men. The aim of this review is to analyze the most important factors related to the enormous impact of osteoporotic fractures on population. Among the most common risk factors, low body mass index; history of fragility fracture, environmental risk, early menopause, smoking, lack of vitamin D, endocrine disorders (for example insulin-dependent diabetes mellitus), use of glucocorticoids, excessive alcohol intake, immobility and others represented the main clinical risk factors associated with augmented risk of fragility fracture. The increasing trend of osteoporosis is accompanied by an underutilization of the available preventive strategies and only a small number of patients at high fracture risk are recognized and successively referred for therapy. This report provides analytic evidences to assess the best practices in osteoporosis management and indications for the adoption of a correct healthcare strategy to significantly reduce the osteoporosis burden. Early diagnosis is the key to resize the impact of osteoporosis on healthcare system. In this context, attention must be focused on the identification of high fracture risk among osteoporotic patients. It is necessary to increase national awareness campaigns across countries in order to reduce the osteoporotic fractures incidence.

5.
Nanomaterials (Basel) ; 6(4)2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-28335194

RESUMO

Aim of this work was to investigate the automatic echographic detection of an experimental drug delivery agent, halloysite clay nanotubes (HNTs), by employing an innovative method based on advanced spectral analysis of the corresponding "raw" radiofrequency backscatter signals. Different HNT concentrations in a low range (5.5-66 × 1010 part/mL, equivalent to 0.25-3.00 mg/mL) were dispersed in custom-designed tissue-mimicking phantoms and imaged through a clinically-available echographic device at a conventional ultrasound diagnostic frequency (10 MHz). The most effective response (sensitivity = 60%, specificity = 95%), was found at a concentration of 33 × 1010 part/mL (1.5 mg/mL), representing a kind of best compromise between the need of enough particles to introduce detectable spectral modifications in the backscattered signal and the necessity to avoid the losses of spectral peculiarity associated to higher HNT concentrations. Based on theoretical considerations and quantitative comparisons with literature-available results, this concentration could also represent an optimal concentration level for the automatic echographic detection of different solid nanoparticles when employing a similar ultrasound frequency. Future dedicated studies will assess the actual clinical usefulness of the proposed approach and the potential of HNTs for effective theranostic applications.

6.
Ann Ist Super Sanita ; 41(4): 493-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16569919

RESUMO

A checking form was introduced in order to test the completeness of electronic and paper patient's charts in a radiotherapy department which had introduced record-and-verify system (RVS) and to improve tha staff performance. The chosen items for the electronic chart were 9 and 5 for paper chart. 223 patients were reviewed in two phases. The data analysis was based on a scoring method, attributing a positive score (+1) to the operator's good behaviour, a negative score (-1) to the lack of data input and a neutral score (0) to the inapplicable situation. The average global score increased from 0.4 to 0.7: in A (lowest complexity) category from 0.37 to 0.64, in B category from 0.4 to 0.89, in C category from 0.48 to 0.61.


Assuntos
Sistemas Computadorizados de Registros Médicos , Prontuários Médicos , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia , Controle de Formulários e Registros/métodos , Fidelidade a Diretrizes , Humanos , Imageamento Tridimensional , Redes Locais , Prontuários Médicos/normas , Sistemas Computadorizados de Registros Médicos/normas , Sistemas Computadorizados de Registros Médicos/estatística & dados numéricos , Patologia Clínica/métodos , Radioterapia Conformacional , Reprodutibilidade dos Testes
7.
Ultrasound Med Biol ; 41(1): 281-300, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25438845

RESUMO

We investigated the possible clinical feasibility and accuracy of an innovative ultrasound (US) method for diagnosis of osteoporosis of the spine. A total of 342 female patients (aged 51-60 y) underwent spinal dual X-ray absorptiometry and abdominal echographic scanning of the lumbar spine. Recruited patients were subdivided into a reference database used for US spectral model construction and a study population for repeatability and accuracy evaluation. US images and radiofrequency signals were analyzed via a new fully automatic algorithm that performed a series of spectral and statistical analyses, providing a novel diagnostic parameter called the osteoporosis score (O.S.). If dual X-ray absorptiometry is assumed to be the gold standard reference, the accuracy of O.S.-based diagnoses was 91.1%, with k = 0.859 (p < 0.0001). Significant correlations were also found between O.S.-estimated bone mineral densities and corresponding dual X-ray absorptiometry values, with r(2) values up to 0.73 and a root mean square error of 6.3%-9.3%. The results obtained suggest that the proposed method has the potential for future routine application in US-based diagnosis of osteoporosis.


Assuntos
Densidade Óssea , Densitometria/métodos , Osteoporose/diagnóstico por imagem , Osteoporose/fisiopatologia , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/fisiopatologia , Ultrassonografia/métodos , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Comput Math Methods Med ; 2013: 278978, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24106524

RESUMO

Labor progression is routinely assessed through transvaginal digital inspections, meaning that the clinical decisions taken during the most delicate phase of pregnancy are subjective and scarcely supported by technological devices. In response to such inadequacies, we combined intrapartum echographic acquisitions with advanced tracking algorithms in a new method for noninvasive, quantitative, and automatic monitoring of labor. Aim of this work is the preliminary clinical validation and accuracy evaluation of our automatic algorithm in assessing progression angle (PA) and fetal head station (FHS). A cohort of 10 parturients underwent conventional labor management, with additional translabial echographic examinations after each uterine contraction. PA and FHS were evaluated by our automatic algorithm on the acquired images. Additionally, an experienced clinical sonographer, blinded regarding the algorithm results, quantified on the same acquisitions of the two parameters through manual contouring, which were considered as the standard reference in the evaluation of automatic algorithm and routine method accuracies. The automatic algorithm (mean error ± 2SD) provided a global accuracy of 0.9 ± 4.0 mm for FHS and 4° ± 9° for PA, which is far above the diagnostic ability shown by the routine method, and therefore it resulted in a reliable method for earlier identification of abnormal labor patterns in support of clinical decisions.


Assuntos
Apresentação no Trabalho de Parto , Ultrassonografia Pré-Natal/estatística & dados numéricos , Algoritmos , Feminino , Monitorização Fetal/estatística & dados numéricos , Cabeça/diagnóstico por imagem , Humanos , Trabalho de Parto , Monitorização Fisiológica/estatística & dados numéricos , Gravidez
9.
World J Radiol ; 5(11): 398-410, 2013 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-24349644

RESUMO

Effective prevention and management of osteoporosis would require suitable methods for population screenings and early diagnosis. Current clinically-available diagnostic methods are mainly based on the use of either X-rays or ultrasound (US). All X-ray based methods provide a measure of bone mineral density (BMD), but it has been demonstrated that other structural aspects of the bone are important in determining fracture risk, such as mechanical features and elastic properties, which cannot be assessed using densitometric techniques. Among the most commonly used techniques, dual X-ray absorptiometry (DXA) is considered the current "gold standard" for osteoporosis diagnosis and fracture risk prediction. Unfortunately, as other X-ray based techniques, DXA has specific limitations (e.g., use of ionizing radiation, large size of the equipment, high costs, limited availability) that hinder its application for population screenings and primary care diagnosis. This has resulted in an increasing interest in developing reliable pre-screening tools for osteoporosis such as quantitative ultrasound (QUS) scanners, which do not involve ionizing radiation exposure and represent a cheaper solution exploiting portable and widely available devices. Furthermore, the usefulness of QUS techniques in fracture risk prediction has been proven and, with the last developments, they are also becoming a more and more reliable approach for assessing bone quality. However, the US assessment of osteoporosis is currently used only as a pre-screening tool, requiring a subsequent diagnosis confirmation by means of a DXA evaluation. Here we illustrate the state of art in the early diagnosis of this "silent disease" and show up recent advances for its prevention and improved management through early diagnosis.

10.
World J Radiol ; 5(10): 356-71, 2013 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-24179631

RESUMO

Fetal malformations are very frequent in industrialized countries. Although advanced maternal age may affect pregnancy outcome adversely, 80%-90% of fetal malformations occur in the absence of a specific risk factor for parents. The only effective approach for prenatal screening is currently represented by an ultrasound scan. However, ultrasound methods present two important limitations: the substantial absence of quantitative parameters and the dependence on the sonographer experience. In recent years, together with the improvement in transducer technology, quantitative and objective sonographic markers highly predictive of fetal malformations have been developed. These markers can be detected at early gestation (11-14 wk) and generally are not pathological in themselves but have an increased incidence in abnormal fetuses. Thus, prenatal ultrasonography during the second trimester of gestation provides a "genetic sonogram", including, for instance, nuchal translucency, short humeral length, echogenic bowel, echogenic intracardiac focus and choroid plexus cyst, that is used to identify morphological features of fetal Down's syndrome with a potential sensitivity of more than 90%. Other specific and sensitive markers can be seen in the case of cardiac defects and skeletal anomalies. In the future, sonographic markers could limit even more the use of invasive and dangerous techniques of prenatal diagnosis (amniocentesis, etc.).

11.
Artigo em Inglês | MEDLINE | ID: mdl-23221218

RESUMO

Prototypal software algorithms for advanced spectral analysis of echographic images were developed to perform automatic detection of simulated tumor masses at two different pathological stages. Previously published works documented the possibility of characterizing macroscopic variation of mechanical properties of tissues through elastographic techniques, using different imaging modalities, including ultrasound (US); however, the accuracy of US-based elastography remains affected by the variable manual modality of the applied compression and several attempts are under investigation to overcome this limitation. Quantitative US (QUS), such as Fourier- and wavelet-based analyses of the RF signal associated with the US images, has been developed to perform a microscopic-scale tissue-type imaging offering new solutions for operator-independent examinations. Because materials able to reproduce the harmonic behavior of human liver can be realized, in this study, tissue-mimicking structures were US imaged and the related RF signals were analyzed using wavelet transform through an in-house-developed algorithm for tissue characterization. The classification performance and reliability of the procedure were evaluated on two different tumor stiffnesses (40 and 130 kPa) and with two different applied compression levels (0 and 3.5 N). Our results demonstrated that spectral components associated with different levels of tissue stiffness within the medium exist and can be mapped onto the original US images independently of the applied compressive forces. This wavelet-based analysis was able to identify different tissue stiffness with satisfactory average sensitivity and specificity: respectively, 72.01% ± 1.70% and 81.28% ± 2.02%.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Algoritmos , Humanos , Hidrogéis , Modelos Biológicos , Imagens de Fantasmas , Álcool de Polivinil , Sensibilidade e Especificidade , Software
12.
Int J Nanomedicine ; 7: 4373-89, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22927756

RESUMO

PURPOSE: To evaluate the diagnostic performance of gold nanorod (GNR)-enhanced optoacoustic imaging employing a conventional echographic device and to determine the most effective operative configuration in order to assure optoacoustic effectiveness, nanoparticle stability, and imaging procedure safety. METHODS: The most suitable laser parameters were experimentally determined in order to assure nanoparticle stability during the optoacoustic imaging procedures. The selected configuration was then applied to a novel tissue-mimicking phantom, in which GNR solutions covering a wide range of low concentrations (25-200 pM) and different sample volumes (50-200 µL) were exposed to pulsed laser irradiation. GNR-emitted optoacoustic signals were acquired either by a couple of single-element ultrasound probes or by an echographic transducer. Off-line analysis included: (a) quantitative evaluation of the relationships between GNR concentration, sample volume, phantom geometry, and amplitude of optoacoustic signals propagating along different directions; (b) echographic detection of "optoacoustic spots," analyzing their intensity, spatial distribution, and clinical exploitability. MTT measurements performed on two different cell lines were also used to quantify biocompatibility of the synthesized GNRs in the adopted doses. RESULTS: Laser irradiation at 30 mJ/cm(2) for 20 seconds resulted in the best compromise among the requirements of effectiveness, safety, and nanoparticle stability. Amplitude of GNR-emitted optoacoustic pulses was proportional to both sample volume and concentration along each considered propagation direction for all the tested boundary conditions, providing an experimental confirmation of isotropic optoacoustic emission. Average intensity of echographically detected spots showed similar behavior, emphasizing the presence of an "ideal" GNR concentration (100 pM) that optimized optoacoustic effectiveness. The tested GNRs also exhibited high biocompatibility over the entire considered concentration range. CONCLUSION: An optimal configuration for GNR-enhanced optoacoustic imaging was experimentally determined, demonstrating in particular its feasibility with a conventional echographic device. The proposed approach can be easily extended to quantitative performance evaluation of different contrast agents for optoacoustic imaging.


Assuntos
Ouro/química , Nanotubos/química , Técnicas Fotoacústicas/métodos , Polietilenoglicóis/química , Ultrassonografia/métodos , Sobrevivência Celular/efeitos dos fármacos , Ouro/farmacologia , Células HeLa , Humanos , Lasers , Células MCF-7 , Teste de Materiais , Tamanho da Partícula , Imagens de Fantasmas , Técnicas Fotoacústicas/instrumentação , Polietilenoglicóis/farmacologia , Processamento de Sinais Assistido por Computador , Transdutores , Ultrassonografia/instrumentação
13.
Artigo em Inglês | MEDLINE | ID: mdl-21989874

RESUMO

Current imaging methods for catheter position monitoring during minimally invasive surgery do not provide an effective support to surgeons, often resulting in the choice of more invasive procedures. This study was conducted to demonstrate the feasibility of non-ionizing monitoring of endovascular devices through embedded quantitative ultrasound (QUS) methods, providing catheter self-localization with respect to selected anatomical structures. QUS-based algorithms for real-time automatic tracking of device position were developed and validated on in vitro and ex vivo phantoms. A trans-esophageal ultrasound probe was adapted to simulate an endovascular device equipped with an intravascular ultrasound probe. B-mode images were acquired and processed in real time by means of a new algorithm for accurate measurement of device position. After off-line verification, automatic position calculation was found to be correct in 96% and 94% of computed frames in the in vitro and ex vivo phantoms, respectively. The average errors of distance measurements (bias ± 2SD) in a 41-step 10-cm-long parabolic pathway were 0.76 ± 3.75 mm or 0.52 ± 3.20 mm, depending on algorithm implementations. Our results showed the effectiveness of QUS-based tracking algorithms for real-time automatic calculation and display of endovascular system position. The method, validated for the case of an endoclamp balloon catheter, can be easily extended to most endovascular surgical systems.


Assuntos
Cateterismo/métodos , Processamento de Imagem Assistida por Computador/métodos , Cirurgia Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Algoritmos , Animais , Aorta Torácica/diagnóstico por imagem , Cateterismo/instrumentação , Bovinos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/instrumentação , Ultrassonografia de Intervenção/instrumentação
14.
Magn Reson Imaging ; 28(4): 511-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20117897

RESUMO

To improve vessel contrast in high-resolution susceptibility-based brain venography, an automatic phase contrast enhancing procedure is proposed, based on a new phase mask filter suitable for maximizing contrast of venous MR signals. The effectiveness of the new approach was assessed both on digital phantoms and on acquired MR human brain images, and then compared with venographic results of phase masking methods in recent literature. The digital phantom consisted of a simulated MR dataset with given signal-to-noise ratios (SNRs), while real human data were collected by scanning healthy volunteers with a 3.0-T MR system and a 3D gradient echo pulse sequence. The new phase mask (NM) was more effective than the conventional mask (CM) both on the digital phantoms and on the acquired MR images. A quantitative comparison based on phantom venograms indicates how this phase enhancement can lead to a significant increase in the contrast-to-noise ratio (CNR) for all considered phase values as well as for all vessel sizes of clinical interest. Likewise, the in vivo brain venograms reveal a better depiction of the smallest venous vessels and the enhancement of many details undetectable in conventional venograms.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/patologia , Circulação Cerebrovascular , Imageamento por Ressonância Magnética/métodos , Flebografia/métodos , Adulto , Automação , Veias Cerebrais/patologia , Meios de Contraste/farmacologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Teóricos , Distribuição Normal , Imagens de Fantasmas
15.
J Mater Sci Mater Med ; 19(2): 899-906, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17665125

RESUMO

Native harmonics generated by nonlinear distortion of ultrasound during propagation in a medium may cause misinterpretations in spectral analysis when studying contrast agents. The aim of this paper is to quantitatively evaluate nonlinear propagation effects of diagnostic ultrasound pulses in biological tissues and to assess whether a cellulose-based hydrogel can be a suitable material for tissue mimicking purposes. Hydrogel and pig liver tissue samples of various thicknesses were insonified in a through-transmission set-up, employing 2.25-MHz pulses with different mechanical index (MI) values (range 0.06-0.60). Second harmonic and first harmonic amplitudes were extracted from spectra of received signals and their ratio was then used to compare hydrogel and liver behaviours. Resulting trends are very similar for sample thicknesses up to 8 cm and highlight a significant increase in nonlinearity for MI > 0.3, for both liver and hydrogel. A numerical procedure was also employed to calculate pressure distribution along the beam axis: these theoretical results showed a very good agreement with experimental data in the low pressure range, though failed in predicting the MI threshold. In conclusion, the hydrogel resulted to be a suitable material for manufacturing tissue mimicking phantoms, in particular to study contrast agent behaviour with a "low power approach".


Assuntos
Materiais Biomiméticos/química , Hidrogéis/química , Fígado/fisiologia , Modelos Biológicos , Acústica , Animais , Fenômenos Biomecânicos , Celulose/química , Suínos , Fatores de Tempo , Ultrassom
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA