Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(6): 1132-1139, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668083

RESUMO

BACKGROUND: Limited data are available on transcatheter heart valves (THVs) durability in bicuspid aortic valve (BAV) stenosis. AIMS: To evaluate evaluating 4-year clinical and echocardiographic outcomes of patients with BAV undergoing transcatheter aortic valve implantation (TAVI). METHODS: The bicuSpid TAvi duraBILITY (STABILITY) registry is an Italian multicentre registry including all consecutive patients with BAV and severe aortic stenosis (AS), treated by means of TAVI between January 2011 and December 2017. Outcomes of interest were all-cause death at 4-year, over time changes in echocardiographic measurements, and THV durability according to the valve aortic research consortium (VARC)-3 update definitions. RESULTS: Study population included 109 patients (50% females; mean age 78 ± 7.5 years) with a mean Society of Thoracic Surgeons Predicted Risk of Mortality score of 5.1 ± 4.3%. Median follow-up (FU) duration was 4.1 years [interquartile range: 2.8-5.1]. The overall cumulative incidence of all-cause death by Kaplan-Meier estimates at 4 years was 32%. Compared to baseline, a significant decrease in transprosthetic mean gradient was obtained after TAVI (54 ± 16 vs. 10 ± 5 mmHg; p < 0.001), whereas a significant increase was observed at 4-year (13 ± 6.4 mmHg, p = 0.03). Cumulative incidence of hemodynamic valve dysfunction (HVD) was 4%. Six patients met HVD criteria: three moderate and three severe HVD. All three cases of severe HVD were clinically relevant (bioprosthetic valve failure [BVF]) with two patients receiving a reintervention (TAVI in TAVI), and one patient experiencing a valve-related death due to endocarditis. CONCLUSIONS: The STABILITY registry suggests that in patients with severe AS and BAV undergoing TAVI, postprocedural clinical benefits might last, over time, up to 4-year FU. The low rates of severe HVD and BVF may support the hypothesis of good THV durability also in BAV recipient.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Sistema de Registros
2.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36841945

RESUMO

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Angiografia Coronária , Cálcio , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Stents
3.
J Interv Cardiol ; 2019: 8586927, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772548

RESUMO

OBJECTIVES: The aim of this study is to assess long-term-outcomes of patients with concomitant CAD and COD treated with different revascularization strategies. BACKGROUND: Multisite artery disease is common and patients with combined disease have poor prognosis. The best therapeutic strategy for patients with concomitant carotid obstructive disease (COD) and coronary artery disease (CAD) remains controversial. METHODS: This observational registry enrolled, between January 2006 and December 2012, 1022 consecutive patients from high volume institutions with concomitant CAD and COD suitable for endovascular, surgical, or hybrid revascularization in both territories selected by consensus of a multidisciplinary team. RESULTS: The cumulative incidence of 5-year major cardiovascular events (MACCE) including cardiovascular death, myocardial infarction (MI), or stroke in the overall population was 12%. The incidence of 5-year MACCE was not statistically different in the surgical, endovascular, or hybrid patients group (10.1% vs. 13.0% vs. 13.2%, P = .257, respectively). However, the hybrid group exhibited rates of myocardial infarction, chronic kidney disease, and cumulative incidence of all clinical events higher than the surgical group. After propensity score matching, the incidence of 5-year MACCE was similar in the three groups (13.0% vs. 15.0% vs. 16.0%, p = .947, respectively). CONCLUSIONS: An individualized revascularization approach of patients with combined CAD and COD yields very good results at long-term follow-up, despite the high risk of this multilevel population even when the baseline clinical features are equalized.


Assuntos
Doenças das Artérias Carótidas/cirurgia , Revascularização Cerebral , Doença da Artéria Coronariana/cirurgia , Efeitos Adversos de Longa Duração , Revascularização Miocárdica , Idoso , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/epidemiologia , Revascularização Cerebral/efeitos adversos , Revascularização Cerebral/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/estatística & dados numéricos , Feminino , Humanos , Incidência , Itália/epidemiologia , Efeitos Adversos de Longa Duração/classificação , Efeitos Adversos de Longa Duração/epidemiologia , Efeitos Adversos de Longa Duração/etiologia , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/efeitos adversos , Revascularização Miocárdica/métodos , Avaliação de Resultados em Cuidados de Saúde , Sistema de Registros/estatística & dados numéricos , Fatores de Risco
4.
Catheter Cardiovasc Interv ; 91(1): 169-174, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27143596

RESUMO

Bioprosthesis degeneration is a relevant clinical issue that is increasingly developing with the higher expectancy of life. Its treatment may be further complicated by the presence of paravalvular leaks, which are usually consequence of tissue friability, annular calcification, and infection. The surgical treatment of such complex conditions may be too risky, so percutaneous techniques in selected centers are becoming an attracting option. We report the case of a 65-year-old gentleman with a previous aortic valve replacement (Perimount n.25) who was admitted with worsening heart failure and transoesophageal evidence of severe intraprosthetic regurgitation and a large paravalvular leak. Since he was judged at too high risk for surgery, he was treated by a fully percutaneous approach. First, he had his large paravalvular leak closed by implantation of two plugs from both retrograde and anterograde routes (arterial-venous loop created). After one month, he underwent a "valve-in-valve" transcatheter aortic valve implantation with a fully repositionable Lotus 23 mm valve, which was able to restore a completely normal aortic valve function and let to a dramatic improvement of his functional status at 6-month follow-up (from NYHA IV to NYHA I), when a transthoracic echocardiogram also confirmed the absence of any aortic regurgitation. This case shows how a tailored step-by-step fully percutaneous strategy is safe and feasible in high-risk patients with both bioprosthesis degeneration and large paravalvular leaks. This novel opportunity would need to be better evaluated in properly addressed long-term clinical studies. © 2016 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Radiografia Intervencionista , Recuperação de Função Fisiológica , Resultado do Tratamento
5.
J Transl Med ; 15(1): 98, 2017 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-28472949

RESUMO

BACKGROUND: The lack of early diagnosis, progression markers and effective pharmacological treatment has dramatic unfavourable effects on clinical outcomes in patients with peripheral artery disease (PAD). Addressing these issues will require dissecting the molecular mechanisms underlying this disease. We sought to characterize the Notch signaling and atherosclerosis relevant markers in lesions from femoral arteries of symptomatic PAD patients. METHODS: Plaque material from the common femoral, superficial femoral or popliteal arteries of 20 patients was removed by directional atherectomy. RNA was obtained from 9 out of 20 samples and analysed by quantitative reverse transcriptase-polymerase chain reaction (qRT-PCR). RESULTS: We detected expression of Notch ligands Delta-like 4 (Dll4) and Jagged1 (Jag1), of Notch target genes Hes1, Hey1, Hey2, HeyL and of markers of plaque inflammation and stability such as vascular cell adhesion molecule 1 (VCAM1), smooth muscle 22 (SM22), cyclooxygenase 2 (COX2), Bcl2, CD68 and miRNAs 21-5p, 125a-5p, 126-5p,146-5p, 155-5p, 424-5p. We found an "inflamed plaque" gene expression profile characterized by high Dll4 associated to medium/high CD68, COX2, VCAM1, Hes1, miR126-5p, miR146a-5p, miR155-5p, miR424-5p and low Jag1, SM22, Bcl2, Hey2, HeyL, miR125a-5p (2/9 patients) and a "stable plaque" profile characterized by high Jag1 associated to medium/high Hey2, HeyL, SM22, Bcl2, miR125a and low Dll4, CD68, COX2, VCAM1, miR126-5p, miR146a-5p, miR155-5p, miR424-5p (3/9 patients). The remaining patients (4/9) showed a plaque profile with intermediate characteristics. CONCLUSIONS: This study reveals the existence of a gene signature associated to Notch activation by specific ligands that could be predictive of PAD progression.


Assuntos
Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Proteína Jagged-1/metabolismo , Doença Arterial Periférica/genética , Doença Arterial Periférica/patologia , Placa Aterosclerótica/patologia , Transcriptoma , Proteínas Adaptadoras de Transdução de Sinal , Idoso , Animais , Proteínas de Ligação ao Cálcio , Colesterol/metabolismo , Feminino , Seguimentos , Humanos , Inflamação/patologia , Ligantes , Masculino , MicroRNAs/genética , MicroRNAs/metabolismo , Miócitos de Músculo Liso/metabolismo , Projetos Piloto , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Ratos , Receptores Notch/metabolismo , Transdução de Sinais/genética
6.
Catheter Cardiovasc Interv ; 90(7): 1206-1211, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28145039

RESUMO

OBJECTIVES: We report procedural and 30-day clinical outcomes following transcatheter aortic valve replacement (TAVR) with Lotus Valve system in a high-risk population. BACKGROUND: Lotus valve is a second-generation TAVR fully repositionable and retrievable device. RELEVANT (REgistry of Lotus valvE for treatment of aortic VAlve steNosis with Tavr) study is an Italian prospective multicentre registry. METHODS: Five major centers performing TAVR using Lotus participated. All high-risk symptomatic patients with severe aortic stenosis were evaluated by a heart team and screened for eligibility for TAVR. Primary end-points were procedural and 30-day mortality. Secondary endpoints included procedural and 30-day safety/effectiveness metrics according to Valve Academic Research Consortium (VARC)-2 criteria. RESULTS: Two hundred and twenty-five patients undergoing TAVR with Lotus were enrolled. Mean age was 82.6 ± 6.3 years, 51.6% females. Mean STS score for mortality was 8.3 ± 5.6. Procedural success was achieved in 98.7% of patients. All-cause mortality was 2.2% at discharge and 2.7% at 30-day. Stroke rate was 2.2% at discharge and 3.1% at 30-day. Patients requiring a new permanent pacemaker implantation were 30.7% at discharge and 31.8% at 30-day. Paravalvular regurgitation (PVR) was trace/mild in 99.1% of patients at discharge. Only two patients (0.9%) had moderate PVR at discharge and at 30-day, whereas none had severe PVR. CONCLUSIONS: RELEVANT study showed that TAVR using Lotus, in a real-world population of patients with severe aortic stenosis at high surgical risk, was associated with excellent device success implantation and early safety according to VARC-2 definition. The pacemaker implantation rate was about a third of patients. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Itália , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 90(4): 566-575, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28295990

RESUMO

OBJECTIVES: Assess clinical consequences of acute stent malapposition (ASM) in the context of the multicenter Centro per la Lotta Contro l'Infarto-Optimization of Percutaneous Coronary Intervention (CLI-OPCI) registry. BACKGROUND: ASM as important determinant of stent thrombosis (ST) risk remains controversial. METHODS: From 2009 to 2013, we retrospectively analyzed postprocedural optical coherence tomography (OCT) findings in 864 patients undergoing percutaneous coronary intervention, assessing prevalence and magnitude of ASM and exploring correlation with outcome, especially ST. RESULTS: Postprocedural OCT revealed a variable grade of ASM in 72.3% of stents without correlation between maximal strut-vessel distance and longitudinal extension (R = 0.164, P < 0.01). At a median follow up of 302 (IQ 127-567) days, ASM did not affect risk of following major cardiac adverse events (MACE); residual ASM was comparable in terms of thickness (median [quartiles] 0.21[IQ 0.1-0.4] vs. 0.20[IQ 0.0-0.3], P = 0.397) and length (2.0[IQ 0.5-4.1] vs. 2.2[IQ 0.0-5.2], P = 0.640) in patients with versus without MACE. The predictive accuracy for outcome was low (C-statistic 0.52, CI 95% 0.47-0.58, P = 0.394) as well for target lesion revascularization (HR 0.80, CI 95% 0.5-1.4) and ST (HR 0.71, CI 95% 0.3-1.5). Likewise, timing to MACE was not influenced by presence of such an ASM with similar rate of acute-subacute (HR 1.09, CI 95% 0.6-1.9), late (HR 0.91, CI 95% 0.5-1.8), and very late (HR 1.23, CI 95% 0.5-2.9) events. CONCLUSIONS: Limited ASM was a common finding after stent implantation, but was not associated to increased risk of stent failure or ST during mid-term follow-up. © 2017 Wiley Periodicals, Inc.


Assuntos
Doença das Coronárias/terapia , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Reestenose Coronária/epidemiologia , Trombose Coronária/epidemiologia , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Prevalência , Falha de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 90(3): 380-386, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28109036

RESUMO

OBJECTIVES: To compare the long-term clinical outcomes of paclitaxel drug-coated-balloons (DCB) and everolimus-eluting-stents (EES) following the treatment of de novo small vessel coronary artery disease. BACKGROUND: It is currently unclear whether treatment of de novo small vessel coronary disease with DCB is comparable to second generation drug-eluting stents, which are the current standard of care. METHODS: The present study enrolled 90 patients with small vessel coronary disease from the DCB treatment arm of the BELLO (Balloon Elution and Late Loss Optimization) trial and 2,000 patients treated with EES at the San Raffaele Scientific Institute. Propensity score matching was performed to adjust for differences in baseline clinical and angiographic characteristics, yielding a total of 181 patients: 90 patients with 94 lesions receiving DCB and 91 patients with 94 lesions receiving EES. Major adverse cardiac events (MACE) were defined as the composite of cardiac death, recurrent non-fatal myocardial infarction, and target vessel revascularization. RESULTS: After propensity score matching, baseline clinical and angiographic characteristics were similar between the two groups. The cumulative MACE rate at 1-year was 12.2% with DCB and 15.4% with EES (P = 0.538). Patients in the DCB group had similar TLR rates as compared to EES over the same interval (4.4% vs. 5.6%; P = 0.720). There were no cases of definite or probable stent or vessel thrombosis. CONCLUSIONS: The use of paclitaxel-DCB appears to be associated with similar clinical outcomes when compared to second-generation-EES in small coronary artery disease. The findings of this study should be confirmed with larger prospective randomized studies with longer follow-up. © 2017 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários , Stents Farmacológicos , Everolimo/administração & dosagem , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Everolimo/efeitos adversos , Feminino , Humanos , Itália , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Paclitaxel/efeitos adversos , Pontuação de Propensão , Modelos de Riscos Proporcionais , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
J Heart Valve Dis ; 26(3): 361-364, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-29092125

RESUMO

The effect of a highly elevated level of right atrial filling pressure on fractional flow reserve (FFR) measurement remains unclear. Transcatheter tricuspid valve intervention, a recently introduced option for inoperable or high-risk patients, represents a unique model of in-vivo physiology to investigate the eventual influence of central venous pressure on coronary FFR measurements. The case is reported of a patient with a degenerated tricuspid surgical bioprosthesis who underwent transcatheter tricuspid valve-in-valve replacement and concomitant coronary functional assessment with FFR. In an experimental model, the significant fall in right atrial pressure did not influence FFR measurements in the presence of angiographically proven mild coronary artery disease.


Assuntos
Função do Átrio Direito , Pressão Atrial , Reserva Fracionada de Fluxo Miocárdico , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide/fisiopatologia , Estenose da Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Cateterismo Cardíaco , Angiografia Coronária , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/terapia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/etiologia , Estenose da Valva Tricúspide/terapia
10.
Eur Heart J ; 36(1): 13-21, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25535085

RESUMO

In patients with carotid disease, the purpose of carotid artery revascularization is stroke prevention. For >50 years, carotid endarterectomy has been considered the standard treatment for severe asymptomatic and symptomatic carotid stenoses. Carotid artery stenting (CAS) has emerged in the last 15 years as minimally invasive alternative to surgery. However, the value of the endovascular approach in the management of carotid disease patients remains highly controversial. The aims of this review are to elucidate the current role of CAS, to describe the major technology advancements in the field, and to speculate about the future of this therapy.


Assuntos
Estenose das Carótidas/cirurgia , Stents , Tecnologia Biomédica/tendências , Endarterectomia das Carótidas/instrumentação , Endarterectomia das Carótidas/métodos , Previsões , Humanos , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Reperfusão/instrumentação , Reperfusão/métodos , Acidente Vascular Cerebral/prevenção & controle
11.
EuroIntervention ; 20(7): e445-e452, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38562068

RESUMO

BACKGROUND: Technological and surgical approaches to carotid artery stenting (CAS) have evolved. Modern randomised controlled trials comparing CAS and carotid endarterectomy (CEA) are limited, and information about updated post-intervention outcomes are mostly from retrospective, small studies. AIMS: This study aims to compare the 30-day outcomes of stroke, transient ischaemic attack (TIA), acute myocardial infarction (AMI) and death with propensity-matched groups of CEA and CAS in asymptomatic and symptomatic patients over a recent study period of new CAS technologies and approaches. METHODS: A retrospective, observational, multicentre analysis was conducted including consecutive symptomatic and asymptomatic patients treated with either primary CEA or CAS for internal carotid artery stenosis, between 2015 and 2022. Patients were propensity score-matched based on comorbidities and assessed according to symptom status. Primary endpoints include composite ipsilateral stroke, TIA, AMI and death within 30 days. Secondary endpoints include technical success and length of hospital stay. RESULTS: From a cohort of 1,110 patients, propensity matching produced 269 distinct treatment pairs (n=538). Most patients were asymptomatic (n=456, 85%). All 6 strokes were minor (CEA=2; CAS=4) and registered among asymptomatic patients. One AMI (CEA) and 1 patient death (CAS) were reported among symptomatic patients. Composite stroke/AMI/death were not significantly different between both types of symptom status and both revascularisation techniques (p=0.44 and p=1, respectively). Technical success was 100%. The length of hospital stay was significantly shorter in asymptomatic patients treated with CAS compared to those treated with CEA (p=0.05), but no difference was registered among symptomatic patients (p=0.32). CONCLUSIONS: Propensity-matched analysis suggests that CAS has similar postprocedural outcomes for stroke, AMI and death at 30 days compared to CEA.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Ataque Isquêmico Transitório , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Endarterectomia das Carótidas/efeitos adversos , Estenose das Carótidas/cirurgia , Ataque Isquêmico Transitório/etiologia , Estudos Retrospectivos , Pontuação de Propensão , Resultado do Tratamento , Stents , Acidente Vascular Cerebral/etiologia , Infarto do Miocárdio/etiologia , Artérias Carótidas , Fatores de Risco
12.
J Pers Med ; 14(3)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38540992

RESUMO

AIMS: To describe through emblematic images rare but clinically relevant carotid artery stenting complications that occurred at two high-volume centres for carotid artery stenting (CAS). BACKGROUND: CAS is an alternative to carotid endarterectomy (CEA) for the treatment of carotid artery stenosis in patients judged to be at high risk for CEA. CAS complications range between 1 and 9% and are higher in older patients complaining of neurological symptoms at the time of presentation. Besides periprocedural or early-after-procedure stroke, which remains the true Achilles' heel of CAS, other dramatic complications might compromise the clinical outcomes of this procedure. METHODS: Five infrequent complications, out of more than 1000 CAS performed in the years 2016-2021, have been described. RESULTS: Among CAS complications, acute carotid stent thrombosis, rescue retrieval of a disconnected distal cerebral embolic protection device, plaque prolapse after carotid stenting, cerebral hyperperfusion syndrome (CHS), and radial artery long sheath entrapment requiring surgical intervention were found to account for 0.3% of the total number of procedures performed by operators with high CAS volume. CONCLUSIONS: Unusual CAS complications may infrequently occur, even in hands of expert operators. To know how to deal with such complications might help interventionalists to improve CAS performance.

13.
Eur Heart J Cardiovasc Pharmacother ; 10(2): 158-169, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-37960983

RESUMO

AIMS: Randomized controlled trials (RCTs) testing bleeding reduction strategies using antiplatelet treatment regimens (BRATs) in acute coronary syndromes (ACS) have shown promising results, but the generalizability of these findings may be significantly influenced by the ethnicity of the patients enrolled, given that East Asian (EA) patients show different ischaemic-bleeding risk profile compared to non-EA patients. METHODS AND RESULTS: RCTs comparing a BRAT vs. standard 12-month dual antiplatelet therapy (DAPT) in patients with ACS undergoing percutaneous coronary intervention (PCI) were selected. The primary efficacy endpoint was major adverse cardiovascular events (MACE) as defined in each trial and the primary safety endpoint was minor or major bleeding. Twenty-six RCTs testing seven different BRATs were included. The only strategy associated with a trade-off in MACE was 'upfront unguided de-escalation' in the subgroup of non-EAs (risk ratio 1.16, 95% confidence interval 1.09-1.24). All but aspirin monotherapy-based strategies (i.e. 'short and very short DAPT followed by aspirin') were associated with reduced bleeding compared with standard DAPT in both EA and non-EA patients. There were no significant differences between subgroups, but the lack of RCTs in some of the included strategies and the difference in the certainty of evidence between EA and non-EA patients revealed that the evidence in support of different BRATs in ACS undergoing PCI is influenced by ethnicity. Moreover, absolute risk reduction estimation revealed that some BRATs might be more effective than others in reducing bleeding according to ethnicity. CONCLUSION: The majority of BRATs are associated with reduced bleeding without any trade-off in hard ischaemic endpoints regardless of ethnicity. However, the supporting evidence and relative safety profiles of different BRATs might be significantly affected by ethnicity, which should be taken into account in clinical practice. STUDY REGISTRATION: This study is registered in PROSPERO (CRD42023416710).


Assuntos
Síndrome Coronariana Aguda , Inibidores da Agregação Plaquetária , Humanos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/tratamento farmacológico , Etnicidade , Hemorragia/induzido quimicamente , Aspirina , Isquemia/tratamento farmacológico
14.
Artigo em Inglês | MEDLINE | ID: mdl-38754988

RESUMO

BACKGROUND: Carriers of cytochrome 2C19 (CYP2C19) loss of function (LoF) alleles treated with clopidogrel have impaired drug metabolism resulting in reduced active metabolite levels, high platelet reactivity (HPR), and an increased risk of thrombotic events. Several alternative antiplatelet therapies have been proposed to overcome HPR in these patients, but their comparative effects remain poorly explored. METHODS: Randomized controlled trials (RCTs) comparing different oral antiplatelet therapies in carriers of CYP2C19 LoF alleles undergoing percutaneous coronary interventions (PCI) were included. A frequentist network meta-analysis was conducted to estimate mean difference (MD) or odds ratios (OR) and 95% confidence intervals (CI). The primary outcome was platelet reactivity assessed by VerifyNow and reported as P2Y12 reaction unit (PRU). The secondary outcome was the rate of HPR. Standard-dose of clopidogrel (75 mg daily) was used as reference treatment. RESULTS: A total of 12 RCTs testing 6 alternative strategies (i.e., clopidogrel 150 mg, prasugrel 3.75 mg, 5 mg, and 10 mg, ticagrelor 90 mg bid, and adjunctive cilostazol 100 mg bid) were included in the network. Compared with standard-dose clopidogrel, the greatest reduction in PRU was observed with prasugrel 10 mg (MD -127.91; 95% CI -141.04; -114.78) and ticagrelor 90 mg bid (MD -124.91; 95% CI -161.78; -88.04), followed by prasugrel 5 mg (MD -76.33; 95% CI -98.01; -54.65) and prasugrel 3.75 mg (MD -73.00; 95% CI -100.28; -45.72). Among other strategies, adjunctive cilostazol (MD-42.64; 95% CI -64.72; -20.57) and high-dose clopidogrel (MD -32.11; 95% CI -51.33; -12.90) were associated with a modest reduction in PRU compared with standard-dose clopidogrel. CONCLUSION: Among carriers of CYP2C19 LoF alleles undergoing PCI, standard-dose prasugrel or ticagrelor are most effective in reducing platelet reactivity, while double-dose clopidogrel and additional cilostazol showed modest effects. Reduced-dose of prasugrel may represent a balanced strategy to overcome HPR without a significant increase in bleeding. The clinical implications of these pharmacodynamic findings warrant further investigation.

15.
Cardiovasc Revasc Med ; 62: 85-94, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38160130

RESUMO

Valve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.


Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos
16.
J Invasive Cardiol ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38598251

RESUMO

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.

17.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38742523

RESUMO

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Masculino , Feminino , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Itália/epidemiologia , Idoso de 80 Anos ou mais , Readmissão do Paciente/estatística & dados numéricos , Falha de Tratamento , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia
18.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506737

RESUMO

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Catéteres , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valvas Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos
19.
Circulation ; 125(16): 2015-26, 2012 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-22438530

RESUMO

BACKGROUND: The optimal duration of dual-antiplatelet therapy and the risk-benefit ratio for long-term dual-antiplatelet therapy after coronary stenting remain poorly defined. We evaluated the impact of up to 6 versus 24 months of dual-antiplatelet therapy in a broad all-comers patient population receiving a balanced proportion of Food and Drug Administration-approved drug-eluting or bare-metal stents. METHODS AND RESULTS: We randomly assigned 2013 patients to receive bare-metal, zotarolimus-eluting, paclitaxel-eluting, or everolimus-eluting stent implantation. At 30 days, patients in each stent group were randomly allocated to receive up to 6 or 24 months of clopidogrel therapy in addition to aspirin. The primary end point was a composite of death of any cause, myocardial infarction, or cerebrovascular accident. The cumulative risk of the primary outcome at 2 years was 10.1% with 24-month dual-antiplatelet therapy compared with 10.0% with 6-month dual-antiplatelet therapy (hazard ratio, 0.98; 95% confidence interval, 0.74-1.29; P=0.91). The individual risks of death, myocardial infarction, cerebrovascular accident, or stent thrombosis did not differ between the study groups; however, there was a consistently greater risk of hemorrhage in the 24-month clopidogrel group according to all prespecified bleeding definitions, including the recently proposed Bleeding Academic Research Consortium classification. CONCLUSIONS: A regimen of 24 months of clopidogrel therapy in patients who had received a balanced mixture of drug-eluting or bare-metal stents was not significantly more effective than a 6-month clopidogrel regimen in reducing the composite of death due to any cause, myocardial infarction, or cerebrovascular accident. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00611286.


Assuntos
Vasos Coronários/cirurgia , Stents Farmacológicos , Inibidores da Agregação Plaquetária/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Aspirina/uso terapêutico , Causas de Morte , Clopidogrel , Reestenose Coronária/mortalidade , Reestenose Coronária/prevenção & controle , Quimioterapia Combinada , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Paclitaxel/uso terapêutico , Risco , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/prevenção & controle , Trombose/mortalidade , Trombose/prevenção & controle , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Resultado do Tratamento
20.
Am J Cardiol ; 198: 1-8, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37182254

RESUMO

Debulking lesions with severe coronary artery calcification (CAC) is highly recommended to obtain good procedural and long-term success. Utilization and performance of coronary intravascular lithotripsy (IVL) after rotational atherectomy (RA) has not been thoroughly studied. This study aimed to evaluate the efficacy and safety of IVL with the Shockwave Coronary Rx Lithotripsy System in lesions with severe CAC as elective or bail-out strategy after RA. This observational, prospective, single-arm, multicenter, international, open-label Rota-Shock registry included patients with symptomatic coronary artery disease and lesions with severe CAC treated by percutaneous coronary intervention, including lesion preparation with RA and IVL, at 23 high-volume centers. Primary efficacy end point was procedural success, defined as final diameter stenosis <30% by quantitative coronary angiography. Primary safety end point was freedom from serious angiographic complications, which included >National Heart, Lung and Blood Institute type B dissection, perforation, abrupt closure, slow or no flow, final thrombolysis in myocardial infarction flow <3, and acute thrombosis. A total of 160 patients were enrolled between June 2020 and June 2022. The primary efficacy end point was observed in 155 patients (96.9%). The primary safety end point occurred in 145 cases (90.6%). Dissections >National Heart, Lung and Blood Institute type B occurred in 3 patients (1.9%), whereas slow or no flow occurred in 8 (5.0%), final thrombolysis in myocardial infarction flow <3 in 3 (1.9%), and perforation in 4 patients (2.5%). Free from inhospital major adverse cardiac and cerebrovascular events, including cardiac death, target vessel myocardial infarction, target lesion revascularization, cerebrovascular accident, definite/probable stent thrombosis, and major bleeding, occurred in 158 patients (98.7%). In conclusion, IVL after RA in lesions with severe CAC was effective and safe, with a very low incidence of complications as either elective or bail-out strategy.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Litotripsia , Infarto do Miocárdio , Trombose , Calcificação Vascular , Humanos , Aterectomia Coronária/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Calcificação Vascular/cirurgia , Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/epidemiologia , Angiografia Coronária , Trombose/etiologia , Litotripsia/efeitos adversos , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA