Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Langmuir ; 28(32): 11858-65, 2012 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-22783994

RESUMO

Meibum is the primary component of the tear film lipid layer. Thought to play a role in tear film stabilization, understanding the physical properties of meibum and how they change with disease will be valuable in identifying dry eye treatment targets. Grazing incidence X-ray diffraction and X-ray reflectivity were applied to meibum films at an air-water interface to identify molecular organization. At room temperature, interfacial meibum films formed two coexisting scattering phases with rectangular lattices and next-nearest neighbor tilts, similar to the Ov phase previously identified in fatty acids. The intensity of the diffraction peaks increased with compression, although the lattice spacing and molecular tilt angle remained constant. Reflectivity measurements at surface pressures of 18 mN/m and above revealed multilayers with d-spacings of 50 Å, suggesting that vertical organization rather than lateral was predominantly affected by meibum-film compression.


Assuntos
Metabolismo dos Lipídeos , Lipídeos/química , Glândulas Tarsais/química , Glândulas Tarsais/metabolismo , Feminino , Humanos , Difração de Raios X
2.
Curr Eye Res ; 39(6): 580-95, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24502301

RESUMO

PURPOSE: Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. MATERIALS AND METHODS: Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. RESULTS: Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). CONCLUSIONS: The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.


Assuntos
Síndromes do Olho Seco/metabolismo , Voluntários Saudáveis , Lágrimas/química , Lágrimas/fisiologia , Piscadela/fisiologia , Dessecação , Humanos , Hidrodinâmica , Aparelho Lacrimal/fisiologia , Concentração Osmolar , Volatilização , Água/química , Equilíbrio Hidroeletrolítico
3.
Adv Colloid Interface Sci ; 206: 250-64, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23842140

RESUMO

Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink.


Assuntos
Córnea , Lágrimas/química , Fenômenos Biofísicos , Humanos , Volatilização
4.
Adv Colloid Interface Sci ; 197-198: 33-57, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23694847

RESUMO

Water-evaporation reduction by duplex-oil films is especially important to understand the physiology of the human tear film. Secreted lipids, called meibum, form a duplex film that coats the aqueous tear film and purportedly reduces tear evaporation. Lipid-layer deficiency is correlated with the occurrence of dry-eye disease; however, in-vitro experiments fail to show water-evaporation reduction by tear-lipid duplex films. We review the available literature on water-evaporation reduction by duplex-oil films and outline the theoretical underpinnings of spreading and evaporation kinetics that govern behavior of these systems. A dissolution-diffusion model unifies the data reported in the literature and identifies dewetting of duplex films into lenses as a key challenge to obtaining significant evaporation reduction. We develop an improved apparatus for measuring evaporation reduction by duplex-oil films including simultaneous assessment of film coverage, stability, and temperature, all under controlled external mass transfer. New data reported in this study fit into the larger body of work conducted on water-evaporation reduction by duplex-oil films. Duplex-oil films of oxidized mineral oil/mucin (MOx/BSM), human meibum (HM), and bovine meibum (BM) reduce water evaporation by a dissolution-diffusion mechanism, as confirmed by agreement between measurement and theory. The water permeability of oxidized-mineral-oil duplex films agrees with those reported in the literature, after correction for the presence of mucin. We find that duplex-oil films of bovine and human meibum at physiologic temperature reduce water evaporation only 6-8% for a 100-nm film thickness pertinent to the human tear film. Comparison to in-vivo human tear-evaporation measurements is inconclusive because evaporation from a clean-water surface is not measured and because the mass-transfer resistance is not characterized.


Assuntos
Lágrimas/química , Água/química , Humanos , Óleos/química , Oxirredução , Propriedades de Superfície , Temperatura , Volatilização
5.
Invest Ophthalmol Vis Sci ; 54(4): 2720-32, 2013 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-23513065

RESUMO

PURPOSE: We explore the unique rheological and structural properties of human and bovine meibomian lipids to provide insight into the physical behavior of the human tear-film lipid layer (TFLL). METHODS: Bulk rheological properties of pooled meibomian lipids were measured by a commercial stress-controlled rheometer; a home-built interfacial stress rheometer (ISR) probed the interfacial viscoelasticity of spread layers of meibomian lipids. Small- and wide-angle x-ray scattering detected the presence and melting of dispersed crystal structures. Microscope examination under cross polarizers provided confirmation of ordered crystals. A differential scanning calorimeter (DSC) analyzed phase transitions in bulk samples of bovine meibum. RESULTS: Bulk and interfacial rheology measurements show that meibum is extremely viscous and highly elastic. It is also a non-Newtonian, shear-thinning fluid. Small- and wide-angle x-ray diffraction (SAXS and WAXS), as well as differential scanning calorimetry (DSC) and polarizing microscopy, confirm the presence of suspended lamellar-crystal structures at physiologic temperature. CONCLUSIONS: We studied meibum architecture and its relation to bulk and interfacial rheology. Bovine and human meibomian lipids exhibit similar physical properties. From all structural probes utilized, we find a melt transition near eye temperature at which lamellar crystals liquefy. Our proposed structure for the tear-film lipid layer at physiologic temperature is a highly viscoelastic, shear-thinning liquid suspension consisting of lipid lamellar-crystallite particulates immersed in a continuous liquid phase with no long-range order. When spread over on-eye tear, the TFLL is a duplex film that exhibits bulk liquid properties and two separate interfaces, air/lipid and water/lipid, with aqueous protein and surfactantlike lipids adsorbed at the water/lipid surface.


Assuntos
Lipídeos/química , Glândulas Tarsais/química , Animais , Varredura Diferencial de Calorimetria , Bovinos , Ciclotrons , Humanos , Microscopia de Polarização , Reologia , Espalhamento de Radiação , Lágrimas/química , Substâncias Viscoelásticas , Viscosidade , Difração de Raios X
6.
Cont Lens Anterior Eye ; 35(6): 260-5, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22840754

RESUMO

In addition to improving oxygen permeability, modern silicone-hydrogel (SiHy) soft contact lenses (SCLs) exceed a limiting diffusive ion permeability to aqueous sodium chloride. Below the ion-permeability threshold, siloxane-based SCLs are prone to bind against the corneal epithelium. Salt permeability is argued to reflect indirectly water hydraulic permeability. However, no quantitative explanation is available to date for a threshold salt permeability. We hypothesize that molecular salt diffusion through a SCL supports the postlens tear film (PoLTF) by enhancing water flow into the PoLTF from the cornea. Higher salt concentrations in the PoLTF raise the osmotic pressure there relative to that in the cornea increasing osmotic water withdrawal from the cornea. The proposed osmotic-withdrawal mechanism successfully predicts a self-consistent threshold lens salt permeability when thin-film attractive binding forces are introduced. For the first time, we present a quantitative picture for the possible origin of a threshold salt permeability in SCL manufacture.


Assuntos
Lentes de Contato Hidrofílicas , Membranas Artificiais , Modelos Químicos , Osmose , Géis de Silicone/química , Cloreto de Sódio/química , Adesividade , Simulação por Computador , Difusão , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA