Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(6)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38534991

RESUMO

(1) Background: Hepatitis C virus (HCV) screening mostly uses a one-assay anti-HCV testing approach, which has a higher probability of false-positive results in populations with low HCV prevalence. (2) Methods: In this investigation, 17,926 participants were screened for HCV, and the reactives were tested using a two-assay anti-HCV approach: Elecsys ElectroChemiLuminescence (ECL) and a ChemiLuminescence ImmunoAssay (CLIA), respectively. A recombinant immunoblot assay (RIBA) was performed to confirm anti-HCV positivity. Statistical analysis was performed. (3) Results: A total of 350 specimens were reactive in the ECL screening, of which CLIA retesting showed that 292 (83.4%) were anti-HCV reactive (283 positives, 9 indeterminate, none negative by RIBA), but 58 (16.6%) were not anti-HCV reactive (15 positive, 12 indeterminate, 31 negatives by RIBA). The two-assay strategy significantly improved the positive predictive value (PPV: 95.00%) with χ2: 7.59 (p < 0.01) compared to the PPV assessed by one assay (PPV: 90.6%) with χ2: 34.51 (p < 0.001). The ROC curve defined a sensibility and specificity for the dual approach of 99.66% and 100.00%. (4) Conclusions: Compared with a one-assay testing strategy, the two-assay testing strategy may significantly reduce false positives in anti-HCV testing and identify inactive HCV infection in low seroprevalence populations.

2.
Diseases ; 10(3)2022 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-35997354

RESUMO

Background: SARS-CoV-2 T-cells are crucial for long-term protection against reinfection. The aim was to demonstrate the Interferon-gamma Release Assay (IGRA) test could be useful for vaccination monitoring. Methods: In a prospective cohort of 98 vaccinated healthcare workers for SARS-CoV-2, we selected 23 people in low-antibodies (Group 1, N = 8), high-antibodies (Group 2, N = 9), and negative control groups (Group 3, N = 6). SARS-CoV-2-specific humoral and cellular responses were analyzed at 8 months after two doses of Pfizer BioNTech, evaluating anti-RBD (Receptor Binding Domain) and RBD-ACE2 (Angiotensin Converting Enzyme-2) blocking antibodies in sera through a Chemiluminescence Immunoassay (CLIA) and T-cells through the IGRA test in heparinized plasma. Moreover, lymphocyte subtyping was executed by a flow cytometer. Statistical analysis was performed. Results: The data confirmed that RBD and RBD-ACE2 blocking ACE2 antibody levels of Group 1 were significantly lower than Group 2; p < 0.001. However, T-cells showed no significant difference between Group 1 and Group 2. Conclusions: This work suggests the need for new strategies for booster doses administration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA