RESUMO
The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls-individually and in combination-on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.
Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados , Controle de Doenças Transmissíveis , Doenças Transmissíveis , Aerossóis , COVID-19/prevenção & controle , HumanosRESUMO
This paper presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM2.5 ), nitrogen dioxide (NO2 ), formaldehyde and carbon dioxide (CO2 ) and time-integrated formaldehyde, NO2 and nitrogen oxides (NOX ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM2.5 , formaldehyde, NO2 , and CO2 were 7.7 µg/m3 , 14.1, 18.8, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM2.5 above the California annual outdoor standard of 12 µg/m3 and also discrete days above the World Health Organization 24-hour guideline of 25 µg/m3 . Two apartments had weekly NO2 above the California annual outdoor standard of 30 ppb.
Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Gás Natural , Material Particulado , Ventilação , Poluentes Atmosféricos , California , Culinária , Monitoramento Ambiental , Formaldeído , Dióxido de Nitrogênio , Pobreza , Respiração Artificial , Emissões de VeículosRESUMO
In this paper, we report on the indoor concentrations from a suite of full-scale outdoor tracer-gas point releases conducted in the downtown area of Oklahoma City in 2003. A point release experiment consisted of releases of sulfur hexafluoride (SF6 ) in multiple buildings and from different outdoor locations. From the measurements, we are able to estimate the concentration variations indoors for a building operating under "typical" operating conditions. The mean indoor spatial coefficients of variation are 30% to 45% from a daytime outdoor release are around 80% during an outdoor evening release. Having estimates of the spatial coefficient of variation provides stakeholders, including first responders, with the likely range of concentrations in the building when little is known about the building characteristics and operating behavior, such as developing urban-scale hazard and consequence analyses. We show differences in indoor measurements at different distances to the release points, floors of the building, and heating, ventilation, and air conditioning system (HVAC) operation. We also show estimates at different time resolutions. The statistics show that in the studied medium to large commercial buildings, spatial differences would result in peak indoor concentrations in certain parts of the buildings that may be substantially higher than the building average. To our knowledge, very few tracer gas measurements have been conducted in buildings of this scope, particularly with measurements on multiple floors and within a floor. The resulting estimates of spatial variability provide a unique opportunity for hazard assessment, and comparison to multi-zone models.
Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Local de Trabalho , Ar Condicionado , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Humanos , VentilaçãoRESUMO
Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO2 ) indoors. Time-integrated measurements were made for formaldehyde, NO2 , and nitrogen oxides (NOX ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.
Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Monitoramento Ambiental , Habitação/estatística & dados numéricos , Material Particulado , Ventilação , California , HumanosRESUMO
This paper provides meta-analyses of the published findings relating the respiratory health of occupants of schools with visible dampness, water damage, visible mold, and/or mold odor. Random effects models were used to develop central estimates and confidence limits for the associations of respiratory health effects with school dampness and mold. Eleven studies, all with cross-sectional designs, were included in the meta-analyses; however, analyses for some health outcomes were based on as few as four studies. Analyses were performed using data from adults and children combined, using only data from children, and using data from adults and children after excluding two studies. The central estimates of odds ratios from the meta-analyses were consistently above unity. The evidence of adverse health effects was strongest for cough and wheeze, which had confidence limits excluding unity in some or all analyses. The odds ratios of 1.32 for cough and 1.68 for wheeze suggest moderate increases in health risk. Studies not included in the meta-analyses provide additional evidence that dampness and mold in schools are associated with adverse health outcomes. These meta-analyses and the published literature not included in the meta-analyses suggest that dampness and mold in schools are associated with adverse respiratory health effects.
Assuntos
Poluição do Ar em Ambientes Fechados/análise , Tosse/etiologia , Fungos , Umidade/efeitos adversos , Sons Respiratórios/etiologia , Instituições Acadêmicas , Adolescente , Adulto , Criança , Estudos Transversais , Feminino , Humanos , MasculinoRESUMO
We estimate postmeter methane (CH4) emissions from California's residential natural gas (NG) system using measurements and analysis from a sample of homes and appliances. Quiescent whole-house emissions (i.e., pipe leaks and pilot lights) were measured using a mass balance method in 75 California homes, while CH4 to CO2 emission ratios were measured for steady operation of individual combustion appliances and, separately, for transient operation of three tankless water heaters. Measured quiescent whole-house emissions are typically <1 g CH4/day, though they exhibit long-tailed gamma distributions containing values >10 g CH4/day. Most operating appliances yield undetectable CH4 to CO2 enhancements in steady operation (<0.01% of gas consumed), though storage water heaters and stovetops exhibit long-tailed gamma distributions containing high values (â¼1-3% of gas consumed), and transients are observed for the tankless heaters. Extrapolating results to the state-level using Bayesian Markov chain Monte Carlo sampling combined with California housing statistics and gas use information suggests quiescent house leakage of 23.4 (13.7-45.6, at 95% confidence) Gg CH4, with pilot lights contributing â¼30%. Emissions from steady operation of appliances and their pilots are 13.3 (6.6-37.1) Gg CH4/yr, an order of magnitude larger than current inventory estimates, with transients likely increasing appliance emissions further. Together, emissions from residential NG are 35.7 (21.7-64.0) Gg CH4/yr, equivalent to â¼15% of California's NG CH4 emissions, suggesting leak repair, improvement of combustion appliances, and adoption of nonfossil energy heating sources can help California meet its 2050 climate goals.
Assuntos
Poluentes Atmosféricos , Gás Natural , Teorema de Bayes , California , MetanoRESUMO
Poor air quality affects the health and wellbeing of large populations around the globe. Although source controls are the most effective approaches for improving air quality and reducing health risks, individuals can also take actions to reduce their personal exposure by staying indoors, reducing physical activity, altering modes of transportation, filtering indoor air, and using respirators and other types of face masks. A synthesis of available evidence on the efficacy, effectiveness, and potential adverse effects or unintended consequences of personal interventions for air pollution is needed by clinicians to assist patients and the public in making informed decisions about use of these interventions. To address this need, the American Thoracic Society convened a workshop in May of 2018 to bring together a multidisciplinary group of international experts to review the current state of knowledge about personal interventions for air pollution and important considerations when helping patients and the general public to make decisions about how best to protect themselves. From these discussions, recommendations were made regarding when, where, how, and for whom to consider personal interventions. In addition to the efficacy and safety of the various interventions, the committee considered evidence regarding the identification of patients at greatest risk, the reliability of air quality indices, the communication challenges, and the ethical and equity considerations that arise when discussing personal interventions to reduce exposure and risk from outdoor air pollution.
Assuntos
Poluição do Ar , Poluição do Ar/efeitos adversos , Poluição do Ar/prevenção & controle , Humanos , Reprodutibilidade dos Testes , Meios de Transporte , Estados UnidosRESUMO
Venting range hoods can control indoor air pollutants emitted during residential cooktop and oven cooking. To quantify their potential benefits, it is important to know how frequently and under what conditions range hoods are operated during cooking. We analyzed data from 54 single family houses and 17 low-income apartments in California in which cooking activities, range hood use, and fine particulate matter (PM2.5) were monitored for one week per home. Range hoods were used for 36% of cooking events in houses and 28% in apartments. The frequency of hood use increased with cooking frequency across homes. In both houses and apartments, the likelihood of hood use during a cooking event increased with the duration of cooktop burner use, but not with the duration of oven use. Actual hood use rates were higher in the homes of participants who self-reported more frequent use in a pre-study survey, but actual use was far lower than self-reported frequency. Residents in single family houses used range hoods more often when cooking caused a discernible increase in PM2.5. In apartments, residents used their range hood more often only when high concentrations of PM2.5 were generated during cooking.