Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

País de afiliação
Intervalo de ano de publicação
1.
Biochem J ; 416(2): 255-61, 2008 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-18643777

RESUMO

AGEs (advanced glycation end-products) accumulate in collagen molecules during uraemia and diabetes, two diseases associated with high susceptibility to bacterial infection. Because neutrophils bind to collagen during their locomotion in extravascular tissue towards the infected area we investigated whether glycoxidation of collagen (AGE-collagen) alters neutrophil migration. Type I collagen extracted from rat tail tendons was used for in vitro glycoxidation (AGE-collagen). Neutrophils were obtained from peripheral blood of healthy adult volunteers and were used for the in vitro study of adhesion and migration on AGE- or control collagen. Glycoxidation of collagen increased adhesion of neutrophils to collagen surfaces. Neutrophil adhesion to AGE-collagen was inhibited by a rabbit anti-RAGE (receptor for AGEs) antibody and by PI3K (phosphoinositide 3-kinase) inhibitors. No effect was observed with ERK (extracellular-signal-regulated kinase) or p38 MAPK (mitogen-activated protein kinase) inhibitors. AGE-collagen was able to: (i) induce PI3K activation in neutrophils, and (ii) inhibit chemotaxis and chemokinesis of chemoattractant-stimulated neutrophils. Finally, we found that blocking RAGE with anti-RAGE antibodies or inhibiting PI3K with PI3K inhibitors restored fMLP (N-formylmethionyl-leucyl-phenylalanine)-induced neutrophil migration on AGE-collagen. These results show that RAGE and PI3K modulate adhesion and migration rate of neutrophils on AGE-collagen. Modulation of adhesiveness may account for the change in neutrophil migration rate on AGE-collagen. As neutrophils rely on their ability to move to perform their function as the first line of defence against bacterial invasion, glycoxidation of collagen may participate in the suppression of normal host defence in patients with diabetes and uraemia.


Assuntos
Matriz Extracelular/fisiologia , Neutrófilos/fisiologia , Receptores Imunológicos/fisiologia , Adulto , Animais , Anticorpos/farmacologia , Adesão Celular , Movimento Celular , Citosol/fisiologia , Glicosilação , Humanos , Ativação do Canal Iônico/fisiologia , Peptídeos/farmacologia , Coelhos , Ratos , Receptor para Produtos Finais de Glicação Avançada , Receptores Imunológicos/efeitos dos fármacos , Valores de Referência , Tendões
2.
Biomaterials ; 29(9): 1139-46, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18078988

RESUMO

The combination of negatively-charged membranes and angiotensin I-converting enzyme inhibitors (ACEi) evokes hypersensitivity reactions (HSR) during hemodialysis and bradykinin (BK)-related peptides have been hypothesized as being responsible for these complications. In this study, we tested the effects of neutralizing the membrane electronegativity (zeta potential) of polyacrylonitrile AN69 membranes by coating a polyethyleneimine layer (AN69-ST membranes) over the generation of kinins induced by blood contact with synthetic membranes. We used minidialyzers with AN69 or AN69-ST membranes in an ex vivo model of plasma and we showed that plasma dialysis with AN69 membranes led to significant BK and des-Arg(9)-BK release, which was potentiated by ACEi. This kinin formation was dramatically decreased by AN69-ST membranes, even in the presence of an ACEi, and kinin recovery in the dialysates was also significantly lower with these membranes. High molecular weight kininogen and factor XII detection by immunoblotting of the protein layer coating both membranes corroborated the results: binding of these proteins and contact system activation on AN69-ST membranes were reduced. This ex vivo experimental model applied to the plasma, dialysate and dialysis membrane could be used for the characterization of the kinin-forming capacity of any biomaterial potentially used in vivo in combination with drugs which modulate the pharmacological activity of kinins.


Assuntos
Resinas Acrílicas , Acrilonitrila/análogos & derivados , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Cininas/sangue , Membranas Artificiais , Diálise Renal/instrumentação , Resinas Acrílicas/efeitos adversos , Acrilonitrila/efeitos adversos , Bradicinina/análogos & derivados , Bradicinina/sangue , Eletroquímica , Feminino , Humanos , Técnicas In Vitro , Masculino , Teste de Materiais , Potenciais da Membrana , Diálise Renal/efeitos adversos
3.
Nephrol Dial Transplant ; 23(6): 2003-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18156457

RESUMO

BACKGROUND: The AN69 ST haemodialysis membrane, a new membrane resulting from coating polyethyleneimine upon the polyacrylonitrile surface, binds heparin. In patients at risk of bleeding, a pilot study has demonstrated the efficient anticoagulant effect of this heparin-coated membrane. Study design. In chronic haemodialyzed patients, we evaluated whether this anticoagulant effect can be validated in a controlled, prospective, open study. Pragmatically, we tested the hypothesis of no difference of the massive clotting rate in two groups of patients haemodialyzed either with 50% reduced standard doses of nonfractionated heparin using the heparin-coated AN69 ST or with a full dose of heparin (100%) using another type of dialysis membrane that does not bind heparin. Secondary objectives included evaluation of partial clotting, changes in haemoglobin levels, erythropoietin consumption and dialyzer performances. RESULTS: One hundred and eighty-four patients were elected and 170 finally included in an 18-month follow-up study. They were allocated to one of the two arms of the study. In the heparin-reduced group (n = 85, mean age: 73 +/- 11 years), 12 472 sessions were performed after priming the AN69 ST dialyzer with 2 L of heparinized saline (5000 IU/L heparin) and using 50% reduced doses of previously administered heparin. In the control group with standard heparin (n = 85, mean age: 74 +/- 13 years), 14 154 sessions were analysed (NS), and mean heparin doses were 2718 +/- 1388 and 4800 +/- 1564 IU per session, respectively (P < 0.001). In the heparin-reduced group, massive clotting occurred in 1.4 per 1000 sessions, whereas it occurred in 1.6 per 1000 sessions in the standard heparin group (P < 0.05). Mild to moderate partial clotting in the venous drip chamber and in the dialyzer was evaluated in a subset of patients, on a visual scale. It was more frequent in the experimental group than in the control group (P < 0.001). Platelets, haemoglobin levels, erythropoietin needs and dialyzer performances remained unchanged in both groups. The global mean death rate was 16.8% per year and did not differ significantly between groups. CONCLUSION: The use of the heparin-coated AN69 ST membrane allows a 50% reduction of standard doses of nonfractionated heparin administration for routine haemo- dialysis without increasing the risk of massive clotting of the extracorporeal circuit. This result needs confirmation since massive clotting questions clinical practice and is team dependent.


Assuntos
Heparina de Baixo Peso Molecular/administração & dosagem , Falência Renal Crônica/terapia , Membranas Artificiais , Diálise Renal/instrumentação , Resinas Acrílicas , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Materiais Revestidos Biocompatíveis , Relação Dose-Resposta a Droga , Falha de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/mortalidade , Masculino , Pessoa de Meia-Idade , Probabilidade , Estudos Prospectivos , Diálise Renal/métodos , Medição de Risco , Distribuição por Sexo , Estatísticas não Paramétricas , Análise de Sobrevida , Resultado do Tratamento
4.
ASAIO J ; 51(4): 348-51, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16156297

RESUMO

Binding polyanionic unfractionated heparin over the modified AN69 polyacrylonitrile membrane, the surface electronegativity of which has been neutralized by polyethyleneimine (AN69-ST), renders the membrane more hemocompatible. This property was tested in two groups of long-term hemodialysis patients. Results were rated as massive or partial clotting of a dialyzer at the end of the session. Group I patients were included in a prospective, cross-over study comparing standard dialysis with hemodialysis without systemic administration of unfractionated heparin (n = 12, 123 sessions). In all instances, priming was made with 2 I saline containing 5,000 IU/l heparin. Only patchy or partial clotting was observed in 11% and 39% of the sessions with standard and heparin-free administration, respectively. Group II patients were included in an open, observational pilot study testing the effects of the heparin-coated membrane, without systemic administration of heparin, in patients at high risk of bleeding (n = 68, 331 sessions). Massive clotting was observed in six sessions only (less than 2%) and normal or slightly patchy dialyzers were found in 88% of the sessions. It is concluded that the dialysis AN69 ST membrane, after adequate priming at bedside, can be used without systemic administration of heparin for hemodialysis in patients at high risk of bleeding.


Assuntos
Anticoagulantes/metabolismo , Heparina/metabolismo , Membranas Artificiais , Diálise Renal/instrumentação , Resinas Acrílicas , Materiais Biocompatíveis , Coagulação Sanguínea , Estudos Cross-Over , Ensaio de Imunoadsorção Enzimática , Fator Xa/metabolismo , Inibidores do Fator Xa , Humanos , Tempo de Tromboplastina Parcial , Projetos Piloto , Polietilenoimina , Estudos Prospectivos , Diálise Renal/métodos , Trombina/biossíntese , Fatores de Tempo
5.
ASAIO J ; 51(4): 342-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16156296

RESUMO

The AN69 ST membrane was designed to render the surface of the native polyacrylonitrile polymer less cationic. This was achieved by layering the membrane with the polycationic biopolymer polyethyleneimine. This new membrane is able to bind heparin to its surface, through electrical interactions, without altering the reactivity of the sulfonate groups of the membrane, regularly distributed in the membrane bulk. The kinetics of unfractionated or low-molecular-weight heparins were studied in vitro and in vivo in sheep. Encouraging results were obtained indicating that heparin-coated hemodialyzers are potent anticoagulants. Priming the AN69 ST membrane-equipped hemodialyzer with heparin, as in regular hemodialysis, could allow drastic reduction of heparin consumption in hemodialysis.


Assuntos
Anticoagulantes/farmacologia , Heparina de Baixo Peso Molecular/farmacologia , Heparina/metabolismo , Membranas Artificiais , Diálise Renal/instrumentação , Resinas Acrílicas , Adsorção , Anafilatoxinas/metabolismo , Animais , Antitrombina III/metabolismo , Materiais Biocompatíveis , Colorimetria , Ativação do Complemento , Complemento C3/biossíntese , Citocinas/classificação , Citocinas/farmacocinética , Dalteparina/farmacologia , Enoxaparina/farmacologia , Circulação Extracorpórea , Fator Xa/metabolismo , Inibidores do Fator Xa , Cinética , Nadroparina/farmacologia , Tempo de Tromboplastina Parcial , Polietilenoimina , Ligação Proteica , Diálise Renal/métodos , Ovinos
6.
ASAIO J ; 50(1): 81-4, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14763496

RESUMO

Continuous venovenous hemodialysis (CVVHD) or hemofiltration conducted with pre- (CVVHpre) or post- (CVVHpost) dilution modes are recommended to treat patients with acute renal failure (ARF) and cardiovascular instability. The efficiency of the three techniques was compared in a study including 18 critically ill patients with ARF. Their mean age was 62.1 +/- 16.7 years, and their mean SAPS II score was 59.5 +/- 14.3. They were treated sequentially with the three techniques for periods of 24 hours each (randomized assignment to one technique the first 24 hours followed by the two others). The PRISMA device and M 100 (AN69S) membrane were used in all instances. Blood and replacement (or dialysis) flow rates were kept at 150 and 25 ml/min, respectively. Urea, creatinine, uric acid, inorganic phosphorus, beta2 microglobulin (beta2m), and retinol binding protein (RBP) were measured every 12 hours in plasma and in 12 hours filtrate collection for 3 days. The results are expressed as filtrate/mean plasma (F/P) ratio for the 12 hour period. Removal of small molecules was 16% higher using CVVHD and CVVHpost than CVVHpre. For beta2m and RBP, CVVHpre was, respectively, 43% and 26% more efficient than CVVHD. CVVHpost gave higher but statistically different removal than CVVHpre only for beta2m. CVVHpost was the most efficient technique for removal of small proteins, but this advantage could be easily counterbalanced using higher volume substitution.


Assuntos
Injúria Renal Aguda/sangue , Injúria Renal Aguda/terapia , Proteínas Sanguíneas/isolamento & purificação , Hemofiltração/métodos , Idoso , Proteínas Sanguíneas/química , Humanos , Pessoa de Meia-Idade , Peso Molecular , Proteínas de Ligação ao Retinol/isolamento & purificação , Proteínas Plasmáticas de Ligação ao Retinol , Microglobulina beta-2/sangue , Microglobulina beta-2/isolamento & purificação
9.
Lancet ; 368(9546): 1491; author reply 1492, 2006 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-17071276
11.
Nephrol Ther ; 6(3): 158-61, 2010 Jun.
Artigo em Francês | MEDLINE | ID: mdl-20359975

RESUMO

The molecular process that occurs at the interface between blood and a haemodialysis membrane determines the host response. The resulting reactions define the degree of membrane biocompatibility. These reactions are triggered by plasma protein adsorption onto the membrane and blood cell stress. Over the past decade, atomic force microscopy (AFM) has provided mechanistic insights into the molecular level of interactions that occur at the biomaterial surface. AFM provides tridimentional images produced by both changes in applied shear nanoforces and dynamic imaging through the molecular analysis of attraction and repulsion forces. The aim of the present brief review is to shortly present the technique of AFM and its emerging applications in haemodialysis, comparing hydrophilic and hydrophobic structures. Dialysis membrane roughness and protein adsorption mapping can be quantitatively estimated, since AFM resolution power is in the range of a nanometer. It is suggested that estimation of roughness and force mapping determining structure/function relationship should be proposed for the best understanding of membrane biocompatibility.


Assuntos
Membranas Artificiais , Diálise Renal , Propriedades de Superfície
12.
Transplantation ; 89(4): 440-5, 2010 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-20177346

RESUMO

BACKGROUND: Plasma clearance of iohexol (PCI) is becoming a commonly used standard tool in many clinical trials to evaluate the glomerular filtration rate (GFR). However, most studies performing PCI use only early plasma samples (2, 3, and 4 hr). This study aims to evaluate the role of early and late plasma sampling in the precision of PCI calculation in transplant recipients. METHODS: We evaluated 342 renal transplant recipients for both renal clearance (RC) and plasma clearance, using iohexol and six blood samples (2, 3, 4, 5, 6, and 24 hr). Patients were divided into three subgroups according to RC: <30, 30 to 60, and >60 mL/min/1.75 m(2). RESULTS: A simplified technique using early plasma samples overestimated GFR with a mean difference between plasma clearance and RC of 53.3%, 25.7%, and 12.5% for the three subgroups, respectively. This difference decreased to 8.8%, 6.3%, and 5.5%, respectively, when the 24-hr sample was included in plasma clearance calculation. CONCLUSION: These results demonstrate that GFR evaluation by PCI in renal transplant recipients requires a late plasma sample.


Assuntos
Análise Química do Sangue/métodos , Meios de Contraste/metabolismo , Iohexol/metabolismo , Transplante de Rim/fisiologia , Adulto , Área Sob a Curva , Viés , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade
14.
Nephrol Ther ; 5(6): 542-9, 2009 Nov.
Artigo em Francês | MEDLINE | ID: mdl-19553166

RESUMO

UNLABELLED: The plasma concentration of 25(OH) D - calcidiol - is low in most of stage 5 renal patients. Due to the lack of renal 1alpha-hydroxylase, no supplementation is recommended. However, calcidiol also displays many extraosseous beneficial antiproliferative effects. It may be useful to correct its deficiency in dialysis patients. The efficacy of an oral supplementation for 6 months with ergocalciferol, (Sterogyl), was evaluated in a monocentric cohort of 107 prevalent hemodialysis patients. Plasma levels of 25(OH) D, parathormone, total and ionized calcium, phosphates, were measured at month 0, 3 and 6 in all patients and plasma levels of 1-25(OH) D at month 0 and 6 in 38 patients with the lowest 25(OH) D levels at baseline. Patients were divided into four groups according to their initial 25(OH) D plasma levels and received ergocalciferol supplementation in accordance to the KDOQI Guidelines for stage 3 and 4 renal patients. RESULTS: 101/107 patients display low levels of 25(OH) D at baseline: mean 11.8+/-11.6 microg/l (normal> 30 microg/l). At the end of the initial three months correction period, the plasma levels of 25(OH) D rose significantly. However, only 60% of patients reach a normal plasma concentration of calcidiol with the highest - 600,000UI - ergocalciferol cumulative dosage. At the end of the three months maintenance period, plasma 25(OH) D concentrations fell in all patients. No significant change was observed in parathormone, calcium, phosphates and 1-25(OH) D plasma levels. There was no hypercalcemic episode. CONCLUSION: KDOQI ergocalciferol recommended doses for stages 3 and 4 renal patients did not correct calcidiol deficiency in hemodialysis patients. New prospective studies are required for defining the modalities of an efficient vitamin D supplementation with ergocalciferol or cholecalciferol.


Assuntos
Deficiência de Vitaminas/tratamento farmacológico , Calcifediol/deficiência , Ergocalciferóis/uso terapêutico , Diálise Renal , Vitaminas/uso terapêutico , Idoso , Deficiência de Vitaminas/sangue , Calcifediol/sangue , Humanos
15.
Am J Transplant ; 5(10): 2441-7, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16162193

RESUMO

The aim of this study was to examine the clinical characteristics, the histological features and the renal expression of vascular endothelial growth factor (VEGF) of five patients with sirolimus-associated thrombotic microangiopathy (TMA). Sirolimus-induced TMA occurs preferentially in kidneys with concomitant endothelial injury: it was observed in three patients with acute cellular rejection on calcineurin inhibitor-free regimen, in one patient with chronic graft rejection on a calcineurin inhibitor-free protocol and in one patient with chronic calcineurin inhibitor nephrotoxicity. We found that renal VEGF expression during sirolimus-induced TMA was significantly lower than VEGF expression in normal transplanted kidneys (p < 0.01). Decreased expression of VEGF seems to be a consequence of sirolimus treatment since (i) analysis of two biopsies performed after the switch of sirolimus to calcineurin inhibitor showed reappearance of VEGF expression, (ii) no decreased expression of VEGF was found in five kidneys with classical TMA and, (iii) an increased expression of VEGF was observed in seven kidneys with acute cellular rejection on a sirolimus-free immunosuppressive regimen (p < 0.01). The potential role of sirolimus-induced downregulation of VEGF as a predisposing factor to the development of TMA is discussed.


Assuntos
Inibidores de Calcineurina , Imunossupressores/farmacologia , Rim/metabolismo , Sirolimo/farmacologia , Trombose/induzido quimicamente , Doenças Vasculares/induzido quimicamente , Fator A de Crescimento do Endotélio Vascular/biossíntese , Adulto , Biópsia , Regulação para Baixo , Endotélio Vascular/patologia , Feminino , Rejeição de Enxerto , Humanos , Citometria por Imagem , Imuno-Histoquímica , Rim/efeitos dos fármacos , Rim/patologia , Glomérulos Renais/metabolismo , Transplante de Rim/métodos , Masculino , Pessoa de Meia-Idade , Circulação Renal , Fator A de Crescimento do Endotélio Vascular/metabolismo
16.
Am J Hum Genet ; 77(4): 617-26, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16175507

RESUMO

Angiotensin I-converting enzyme inhibitors (ACEi), which are used to treat common cardiovascular diseases, are associated with a potentially life-threatening adverse reaction known as angioedema (AE-ACEi). We have previously documented a significant association between AE-ACEi and low plasma aminopeptidase P (APP) activity. With eight large pedigrees, we hereby demonstrate that this quantitative trait is partially regulated by genetic factors. We tested APP activity using a variance-component QTL analysis of a 10-cM genomewide microsatellite scan enriched with seven markers over two candidate regions. We found significant linkage (LOD = 3.75) to a locus that includes the XPNPEP2 candidate gene encoding membrane-bound APP. Mutation screening of this QTL identified a large coding deletion segregating in one pedigree and an upstream single-nucleotide polymorphism (C-2399A SNP), which segregates in the remaining seven pedigrees. Measured genotype analysis strongly suggests that the linkage signal for APP activity at this locus is accounted for predominantly by the SNP association. In a separate case-control study (20 cases and 60 controls), we found significant association of this SNP to ACEi-induced AE (P=.0364). In conclusion, our findings provide supporting evidence that the C-2399A variant in XPNPEP2 is associated with reduced APP activity and a higher incidence of AE-ACEi.


Assuntos
Aminopeptidases/genética , Angioedema/induzido quimicamente , Angioedema/genética , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Aminopeptidases/sangue , Estudos de Coortes , Feminino , Ligação Genética , Humanos , Masculino , Mutação , Linhagem , Locos de Características Quantitativas
17.
Nephrol Dial Transplant ; 18(10): 2147-53, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-13679494

RESUMO

BACKGROUND: Hypertension and hyperuricaemia are common side-effects of cyclosporin A (CsA) treatment in renal transplant recipients. While it is well established that the calcium channel blocker amlodipine can control CsA-induced hypertension effectively in this patient population, recent evidence suggests amlodipine might also reduce hyperuricaemia. The present study was designed to compare the effects of the calcium channel blocker amlodipine (5-10 mg/day) and the beta-adrenoceptor antagonist tertatolol (5-10 mg/day) on CsA-induced hyperuricaemia in post-renal transplant recipients with hypertension. METHODS: Forty-eight hypertensive renal transplant recipients on a stable dose of CsA were randomized in a double-blind, parallel-group manner to receive either amlodipine (n = 24) or tertatolol (n = 24) for 60 days. The primary outcome measure was the change from baseline in serum uric acid concentration. Secondary analyses of efficacy were based on changes in renal function and blood pressure. RESULTS: Amlodipine significantly decreased serum uric acid levels from 483 +/- 99 to 431 +/- 110 microM/l (P < 0.001), while tertatolol significantly increased uric acid from 450 +/- 98 to 476 +/-84 microM/l (P = 0.006). Amlodipine also significantly increased glomerular filtration rate (P = 0.0048) and the clearance rate of uric acid (P = 0.023) and it reduced the fractional proximal tubular reabsorption of sodium (P < 0.001), compared with tertatolol. Renal plasma flow and filtered fraction were unaffected by both treatments, as was trough CsA blood concentration. Amlodipine lowered systolic blood pressure to a significantly greater extent than did tertatolol (P = 0.007). The time-dependent profile of diastolic blood pressure did not differ significantly between treatment groups. Both drugs were well tolerated. CONCLUSIONS: Amlodipine could be more appropriate than tertatolol for CsA-induced hypertension and hyperuricaemia in renal transplant recipients.


Assuntos
Anlodipino/administração & dosagem , Ciclosporina/efeitos adversos , Hipertensão/tratamento farmacológico , Hiperuricemia/tratamento farmacológico , Transplante de Rim , Propanolaminas/administração & dosagem , Tiofenos/administração & dosagem , Adulto , Ciclosporina/administração & dosagem , Método Duplo-Cego , Feminino , Seguimentos , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Hipertensão/induzido quimicamente , Hiperuricemia/induzido quimicamente , Imunossupressores/administração & dosagem , Imunossupressores/efeitos adversos , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Valores de Referência , Medição de Risco , Imunologia de Transplantes , Resultado do Tratamento , Vasodilatadores/administração & dosagem
18.
Nephrol Dial Transplant ; 18(10): 2097-104, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-13679486

RESUMO

BACKGROUND: Binding of polycationic unfractionated heparin onto the modified AN69 polyacrylonitrile membrane, whose surface electronegativity has been neutralized by layering polyethyleneimine (AN69ST), produces stable coating. We investigated whether the heparin-coated membrane was suitable for regular haemodialysis with low heparin doses. METHODS: Sheep were instrumented for extracorporeal circulation perfusing a dialyser equipped with either the AN69ST or the original AN69 membrane. Dialysis sessions were performed after priming the dialyser with heparinized saline. The session was conducted without systemic administration of heparin. In chronic haemodialysis patients, the AN69ST membrane was tested for safety, clotting and thrombin generation according to protocols of 4-h haemodialysis sessions with tapered heparin doses. The goal was to define optimal heparin requirements with the heparin-coated membrane in the setting of continuous or intermittent administration of heparin. Both unfractionated and low molecular weight heparin (LMWH) (enoxaparin) were tested. RESULTS: In sheep, systemic heparin-free haemodialysis was conducted for 6 h without clotting using the heparin-coated dialyser. In the same conditions, massive clotting was observed within 90 min of dialysis with the native AN69 membrane. In man, through kinetic measurements of activated partial thromboplastin time (APTT), heparin anti-Xa concentration and thrombin-anti-thrombin complexes levels (TAT), significant dialyser clotting was avoided when APTT and anti-Xa concentration at 180 min of dialysis, were maintained at >40 s and >0.2 IU/ml, respectively. With the AN69ST heparin-coated membrane, thrombin generation was reduced then suppressed, as compared with the original AN69, primed in the same conditions. Safety of haemodialysis conducted with the AN69ST heparin-coated membrane and low doses of unfractionated heparin (50% reduction of the reference dose) was validated by a survey of 2590 sessions in 32 patients. Doses of LMWH were also safely reduced by 50%. In addition, haemodialysis without systemic administration of heparin was possible with minor risk of clotting. CONCLUSION: During the rinsing phase, the ionic interactions between the new AN69ST polyacrylonitrile membrane and unfractionated heparin induce stable heparin coating. This allows a significant reduction of systemic anticoagulant requirements without increasing the risk of clotting, both in the experimental setting and in the chronic haemodialysis patients. Further studies are required to assess this advantage in patients with acute renal failure and at risk of bleeding and to reduce the metabolic consequences of long-term treatment with heparin.


Assuntos
Anticoagulantes/administração & dosagem , Heparina/farmacologia , Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Resinas Acrílicas , Animais , Materiais Biocompatíveis , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Esquema de Medicação , Enoxaparina/farmacologia , Feminino , Humanos , Masculino , Membranas Artificiais , Diálise Renal/métodos , Medição de Risco , Estudos de Amostragem , Sensibilidade e Especificidade , Ovinos
19.
Kidney Int ; 65(2): 654-60, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14717938

RESUMO

BACKGROUND: An epidemic of aseptic peritonitis related to the presence of peptidoglycan contaminant in some batches of icodextrin solution (Extraneal, Baxter Healthcare Corporation) occurred in Europe in the first six months of 2002. METHODS: By case-control study we examined the clinical and biologic features of 5 patients with icodextrin-induced peritonitis (group AP) and compared them with 7 patients with bacterial peritonitis (group BP) recruited in our clinical center between January and June 2002. RESULTS: Diagnosis of icodextrin-induced peritonitis was confirmed in all cases by a positive reintroduction test with contaminated batches of icodextrin. No recurrence was observed on re-exposure to icodextrin free of peptidoglycan. Skin tests were positive with contaminated icodextrin in 2 of 5 patients, while they were negative with icodextrin solution free of peptidoglycan (<0.6 ng/mL). During peritonitis, serum level of C-reactive protein (CRP) was lower in group AP (42.4 +/- 34 mg/L) than in group BP (135 +/- 59 mg/L) (P= 0.01). Leukocyte number in peritoneal dialysis effluent was lower in group AP (284 +/- 101/mm3), with a lower neutrophil/monocyte ratio (N/M = 0.67) than in group BP (1410 +/- 973/mm3; N/M = 4) (P < 0.05). A low number of peritoneal fluid eosinophilia (11 +/- 8%) was detected in group AP. CONCLUSION: Icodextrin-induced peritonitis was associated with a burst of intraperitoneal cytokines. The phenotype of peritoneal neutrophils was different between aseptic and bacterial peritonitis, indicating that inflammatory stimuli that activate neutrophils in both types of peritonitis are clearly distinct. Finally, peritoneal injury measured by weight gain, peritoneal permeability, and CA125 concentration seemed to be less severe during icodextrin-induced peritonitis than during bacterial peritonitis.


Assuntos
Infecções Bacterianas/imunologia , Soluções para Diálise/efeitos adversos , Glucanos/efeitos adversos , Glucose/efeitos adversos , Falência Renal Crônica/complicações , Diálise Peritoneal , Peritonite/induzido quimicamente , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Citocinas/metabolismo , Feminino , Glucanos/imunologia , Glucose/imunologia , Humanos , Icodextrina , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Ativação de Neutrófilo , Peptidoglicano/imunologia , Peritonite/imunologia , Peritonite/microbiologia
20.
Nephrol Dial Transplant ; 21(12): 3600-1; author reply 3601, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17105823
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA