Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 49(2): 517-526, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34232350

RESUMO

PURPOSE: In PSMA-ligand PET/CT imaging, standardized evaluation frameworks and image-derived parameters are increasingly used to support prostate cancer staging. Clinical applicability remains challenging wherever manual measurements of numerous suspected lesions are required. Deep learning methods are promising for automated image analysis, typically requiring extensive expert-annotated image datasets to reach sufficient accuracy. We developed a deep learning method to support image-based staging, investigating the use of training information from two radiotracers. METHODS: In 173 subjects imaged with 68Ga-PSMA-11 PET/CT, divided into development (121) and test (52) sets, we trained and evaluated a convolutional neural network to both classify sites of elevated tracer uptake as nonsuspicious or suspicious for cancer and assign them an anatomical location. We evaluated training strategies to leverage information from a larger dataset of 18F-FDG PET/CT images and expert annotations, including transfer learning and combined training encoding the tracer type as input to the network. We assessed the agreement between the N and M stage assigned based on the network annotations and expert annotations, according to the PROMISE miTNM framework. RESULTS: In the development set, including 18F-FDG training data improved classification performance in four-fold cross validation. In the test set, compared to expert assessment, training with 18F-FDG data and the development set yielded 80.4% average precision [confidence interval (CI): 71.1-87.8] for identification of suspicious uptake sites, 77% (CI: 70.0-83.4) accuracy for anatomical location classification of suspicious findings, 81% agreement for identification of regional lymph node involvement, and 77% agreement for identification of metastatic stage. CONCLUSION: The evaluated algorithm showed good agreement with expert assessment for identification and anatomical location classification of suspicious uptake sites in whole-body 68Ga-PSMA-11 PET/CT. With restricted PSMA-ligand data available, the use of training examples from a different radiotracer improved performance. The investigated methods are promising for enabling efficient assessment of cancer stage and tumor burden.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Ácido Edético , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
3.
Sci Rep ; 14(1): 5001, 2024 02 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424177

RESUMO

To explore the feasibility of combined radiomics of post-treatment I-131 total body scan (TBS) and clinical parameter to predict successful ablation in low-risk papillary thyroid carcinoma (PTC) patients. Data of low-risk PTC patients who underwent total/near total thyroidectomy and I-131 ablation 30 mCi between April 2015 and July 2021 were retrospectively reviewed. The clinical factors studied included age, sex, and pre-ablative serum thyroglobulin (Tg). Radiomic features were extracted via PyRadiomics, and radiomic feature selection was performed. The predictive performance for successful ablation of the clinical parameter, radiomic, and combined models (radiomics combined with clinical parameter) was calculated using the area under the receiver operating characteristic curve (AUC). One hundred and thirty patients were included. Successful ablation was achieved in 77 patients (59.2%). The mean pre-ablative Tg in the unsuccessful group (15.50 ± 18.04 ng/ml) was statistically significantly higher than those in the successful ablation group (7.12 ± 7.15 ng/ml). The clinical parameter, radiomic, and combined models produced AUCs of 0.66, 0.77, and 0.87 in the training sets, and 0.65, 0.69, and 0.78 in the validation sets, respectively. The combined model produced a significantly higher AUC than that of the clinical parameter (p < 0.05). Radiomic analysis of the post-treatment TBS combined with pre-ablative serum Tg showed a significant improvement in the predictive performance of successful ablation in low-risk PTC patients compared to the use of clinical parameter alone.Thai Clinical Trials Registry TCTR identification number is TCTR20230816004 ( https://www.thaiclinicaltrials.org/show/TCTR20230816004 ).


Assuntos
Neoplasias da Glândula Tireoide , Humanos , Câncer Papilífero da Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/radioterapia , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/cirurgia , Radioisótopos do Iodo/uso terapêutico , Estudos Retrospectivos , Radiômica
4.
Nucl Med Mol Imaging ; 57(3): 126-136, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37187950

RESUMO

Purpose: We assessed the lesion detection performance of the dual-tracer parathyroid SPECT imaging using the joint reconstruction method. Materials and Methods: Thirty-six noise realizations were created from SPECT projections collected from an in-house neck phantom to emulate 99mTc-pertechnetate/99mTc-sestamibi parathyroid SPECT datasets. Difference images representing parathyroid lesions were reconstructed using the subtraction and the joint methods whose corresponding optimal iteration was defined as the iteration which maximized the channelized Hotelling observer signal-to-noise ratio (CHO-SNR). The joint method whose initial estimate was derived from the subtraction method at optimal iteration (the joint-AltInt method) was also assessed. In a study of 36 patients, a human-observer lesion-detection study was performed using difference images from the three methods at optimal iteration and the subtraction method with four iterations. The area under the receiver operating characteristic curve (AUC) was calculated for each method. Results: In the phantom study, both the joint-AltInt method and the joint method improved SNR compared to the subtraction method at their optimal iteration by 444% and 81%, respectively. In the patient study, the joint-AltInt method yielded the highest AUC of 0.73 as compared with 0.72, 0.71, and 0.64 from the joint method, the subtraction method at optimal iteration, and the subtraction method at four iterations. At a specificity of at least 0.70, the joint-AltInt method yielded significantly higher sensitivity than the other methods (0.60 vs 0.46, 042, and 0.42; p < 0.05). Conclusions: The joint reconstruction method yielded higher lesion detectability than the conventional method and holds promise for dual-tracer parathyroid SPECT imaging.

5.
J Nucl Med ; 64(6): 896-901, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36581373

RESUMO

This study was performed to assess the prognostic utility of conventional biochemical and imaging response criteria and 68Ga-PSMA11 PET-adapted or -specific systems regarding overall survival (OS) in men with metastatic hormone-sensitive and castration-resistant prostate cancer (PC) treated with taxane-based chemotherapy. Methods: A total of 103 patients (metastatic hormone-sensitive PC, n = 57; castration-resistant PC, n = 46) underwent taxane-based chemotherapy. All patients had a minimum of 2 prostate-specific membrane antigen (PSMA) PET scans (at baseline and up to 3 mo after treatment). PSMA PET response was assessed by RECIST 1.1, adapted Prostate Cancer Working Group Criteria 3 (using PSMA PET instead of bone scan), aPERCIST, and PSMA PET progression (PPP) criteria. Response by each criterion was stratified by either progressive disease (PD) or non-PD. For aPERCIST, stratification by PD, stable disease (SD), and partial/complete remission (PR/CR) was performed. Biochemical response was determined by a prostate-specific antigen decrease of at least 50%. Subgroup analyses were performed by castration status. Univariable Cox proportional hazards regression analyses including Harrell's concordance indices were calculated to investigate the association of PD by response criteria and OS. Kaplan-Meier tests including log-rank statistics were calculated for survival analyses. Results: Twenty-six (25%) patients had unmeasurable disease by RECIST 1.1. PD by any response criterion was associated with an at least 2.5-fold increased risk of death and was highest for PD versus CR/PR by aPERCIST (hazard ratio, 11.4) on univariable regression. Stratified by castration status, a similar pattern was observed. PD by any criterion as associated with significantly shortened OS across overall and subgroup analyses. PR/CR by aPERCIST identified patients with lower risk of death and longer OS compared with patients with PD or SD. Conclusion: PSMA PET-based response criteria (PPP, aPERCIST, adapted Prostate Cancer Working Group Criteria 3) have high prognostic utility in men with metastatic PC undergoing taxane-based chemotherapy. PPP is simple to use, identified most patients with PD, and showed best prognostic utility regarding OS. PR/CR by aPERCIST identifies a subgroup of responders (PR/CR) showing better outcomes than patients with PD or SD. Future studies are warranted to amend the current paradigm relying on mere differentiation of PD versus non-PD in metastatic PC and to identify true treatment responders by imaging criteria.


Assuntos
Radioisótopos de Gálio , Neoplasias de Próstata Resistentes à Castração , Masculino , Humanos , Prognóstico , Radioisótopos de Gálio/uso terapêutico , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Taxoides/uso terapêutico , Hormônios , Antígeno Prostático Específico , Resultado do Tratamento , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Lutécio/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico
6.
J Nucl Med ; 64(7): 1036-1042, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37230531

RESUMO

Our objective was to compare the ability to detect histopathologically confirmed lymph node metastases by early and delayed [99mTc]Tc-PSMA-I&S SPECT/CT in early biochemically recurrent prostate cancer. Methods: We retrospectively analyzed 222 patients selected for radioguided surgery using [99mTc]Tc-PSMA-I&S SPECT/CT at different time points after injection (≤4 h and >15 h). In total, 386 prostate-specific membrane antigen (PSMA) PET predetermined lesions were analyzed on SPECT/CT using a 4-point scale, and the results were compared between early and late imaging groups, with uni- and multivariate analyses performed including prostate-specific antigen, injected [99mTc]Tc-PSMA-I&S activity, Gleason grade group, initial TNM stage, and, stratified by size, PSMA PET/CT-positive lymph nodes. PSMA PET/CT findings served as the standard of reference. Results: [99mTc]Tc-PSMA-I&S SPECT/CT had a significantly higher positivity rate for detecting lesions in the late than the early imaging group (79%, n = 140/178, vs. 27%, n = 12/44 [P < 0.05] on a patient basis; 60%, n = 195/324, vs. 21%, n = 13/62 [P < 0.05] on a lesion basis). Similar positivity rates were found when lesions were stratified by size. Multivariate analysis found that SUVmax on PSMA PET/CT and the uptake time of [99mTc]Tc-PSMA-I&S were independent predictors for lesion detectability on SPECT/CT. Conclusion: Late imaging (>15 h after injection) should be preferred when [99mTc]Tc-PSMA-I&S SPECT/CT is used for lesion detection in early biochemical recurrence of prostate cancer. However, the performance of PSMA SPECT/CT is clearly inferior to that of PSMA PET/CT.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Recidiva Local de Neoplasia , Neoplasias da Próstata/patologia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Gálio
7.
Mol Imaging Radionucl Ther ; 31(2): 130-138, 2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35771002

RESUMO

Objectives: Myocardial perfusion scintigraphy (MPS) is an important diagnostic test for detecting of coronary artery stenosis (CAS); however, tissue attenuation can lead to a difference in accuracy. We evaluated the diagnostic accuracy of attenuation-corrected (AC) and non-attenuation-corrected (NC) MPS for the detection of CAS. Methods: We retrospectively recruited patients who underwent invasive coronary angiography within 10 months after Tc-99m sestamibi MPS. The AC and NC perfusion images were analyzed separately, and each myocardial segment was scored based on relative uptake from 0 to 4. The summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) were calculated. The diagnostic performances were analyzed using the area under the curve (AUC) of the receiver operating characteristic curve. Results: From 117 patients, significant coronary stenosis was present in 66 patients (56%). The SSS and SRS obtained from NC-images were higher than those from AC, supporting the presence of attenuation artifacts in NC images. The AUC of SSS and SDS were significantly higher than those of SRS in both AC- and NC-images, but no significant difference was found between the AUC of SSS, and those of SDS. The optimal cut-offs were >12 for AC-SSS, >15 for NC-SSS, >4 for AC-SDS and >3 for NC-SDS. There was no statistically significant difference in the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy among AC-SSS, NC-SSS, AC-SDS, and NC-SDS. Conclusion: NC-based Tc-99m-sestamibi MPS promised comparable accuracy to AC images by using different cut-off values for diagnosis.

8.
Ann Nucl Med ; 36(1): 24-32, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34559366

RESUMO

PURPOSE: Previously, a joint ictal/inter-ictal SPECT reconstruction was proposed to reconstruct a differential image representing the change of brain SPECT image from an inter-ictal to an ictal study. The so-called joint method yielded better performance for epileptic foci localization than the conventional subtraction method. In this study, we evaluated the performance of different reconstruction settings of the joint reconstruction of ictal/inter-ictal SPECT data, which creates a differential image showing the difference between ictal and inter-ictal images, in lesion detection and localization in epilepsy imaging. METHODS: Differential images reconstructed from phantom data using the joint and the subtraction methods were compared based on lesion detection performance (channelized Hotelling observer signal-to-noise ratio (SNRCHO) averaged across four lesion-to-background contrast levels) at the optimal iteration. The joint-initial method which was the joint method that was initialized by the subtraction method at optimal iteration was also used to reconstruct differential images. These three methods with respective optimal iteration and the subtraction method with four iterations were applied to epileptic patient datasets. A human observer lesion localization study was performed based on localization receiver operating characteristic (LROC) analysis. RESULTS: From the phantom study, at their respective optimal iteration, the joint method yielded an improvement in lesion detection performance over the subtraction method of 26%, which increased to 145% when using the joint-initial method. From the patient study, the joint-initial method yielded the highest area under the LROC curve as compared with those of the joint and the subtraction methods with optimal iteration and with 4 iterations (0.44 vs 0.41, 0.39 and 0.36, respectively). CONCLUSIONS: In lesion detection and localization, the joint method at optimal iteration outperformed the subtraction method at optimal iteration and at iteration typically used in clinical practice. Furthermore, initialization by the subtraction method improved the performance of the joint method.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único
9.
J Nucl Med ; 63(6): 833-839, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34531260

RESUMO

Radiohybrid prostate-specific membrane antigen (rhPSMA) ligands allow for labeling with 18F and radiometals for endoradiotherapy. rhPSMA-7.3 has been designated as a lead compound with promising preclinical data for 177Lu-rhPSMA-7.3, which has shown higher tumor uptake than 177Lu-PSMA I&T. In this retrospective analysis, we compared pretherapeutic clinical dosimetry data of both PSMA ligands. Methods: Six patients with metastatic castration-resistant prostate cancer underwent both 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T pretherapeutic dosimetry. Whole-body scintigraphy was performed at 1 h, 4 h, 24 h, 48 h, and 7 d after injection. Regions of interest covering the whole body, organs, bone marrow, and tumor lesions were drawn for each patient. Absorbed doses for individual patients and pretherapeutic applications were calculated using OLINDA/EXM. To facilitate the comparison of both ligands, we introduced the therapeutic index (TI), defined as the ratio of mean pretherapeutic doses to tumor lesions over relevant organs at risk. Results: Mean whole-body pretherapeutic effective doses for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T were 0.12 ± 0.07 and 0.05 ± 0.03 Sv/GBq, respectively. Mean absorbed organ doses for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T were, for example, 1.65 ± 0.28 and 0.73 ± 0.18 Gy/GBq for the kidneys, 0.19 ± 0.09 and 0.07 ± 0.03 Gy/GBq for the liver, 2.35 ± 0.78 and 0.80 ± 0.41 Gy/GBq for the parotid gland, and 0.67 ± 0.62 and 0.30 ± 0.27 Gy/GBq for the bone marrow, respectively. Tumor lesions received mean absorbed doses of 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T of 6.44 ± 6.44 and 2.64 ± 2.24 Gy/GBq, respectively. The mean TIs for the kidneys were 3.7 ± 2.2 and 3.6 ± 2.2 for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T, respectively, and those for the bone marrow were 15.2 ± 10.2 and 15.1 ± 10.2 for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T, respectively. Conclusion: Pretherapeutic clinical dosimetry confirmed preclinical results of mean absorbed doses for tumors that were 2-3 times higher for 177Lu-rhPSMA-7.3 than for 177Lu-PSMA I&T. Absorbed doses to normal organs also tended to be higher for 177Lu-rhPSMA-7.3, resulting overall in similar average TIs for both radiopharmaceuticals with considerable interpatient variability. 177Lu-rhPSMA-7.3 has promise for a therapeutic efficacy similar to that of 177Lu-PSMA I&T at smaller amounts of injected activity, simplifying radiation safety measurements (especially for large patient numbers or dose escalation regimens).


Assuntos
Neoplasias de Próstata Resistentes à Castração , Dipeptídeos/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Humanos , Ligantes , Lutécio/uso terapêutico , Masculino , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/patologia , Compostos Radiofarmacêuticos/efeitos adversos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ureia/análogos & derivados
10.
J Nucl Med ; 63(3): 415-423, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34168013

RESUMO

Fibroblast activation protein (FAP) is a promising target for diagnosis and therapy of numerous malignant tumors. FAP-2286 is the conjugate of a FAP-binding peptide, which can be labeled with radionuclides for theranostic applications. We present the first-in-humans results using 177Lu-FAP-2286 for peptide-targeted radionuclide therapy (PTRT). Methods: PTRT using 177Lu-FAP-2286 was performed on 11 patients with advanced adenocarcinomas of the pancreas, breast, rectum, or ovary after prior confirmation of uptake on 68Ga-FAP-2286 or 68Ga-FAPI-04 PET/CT. Results: Administration of 177Lu-FAP-2286 (5.8 ± 2.0 GBq; range, 2.4-9.9 GBq) was well tolerated, with no adverse symptoms or clinically detectable pharmacologic effects being noticed or reported in any of the patients. The whole-body effective dose was 0.07 ± 0.02 Gy/GBq (range, 0.04-0.1 Gy/GBq). The mean absorbed doses for kidneys and red marrow were 1.0 ± 0.6 Gy/GBq (range, 0.4-2.0 Gy/GBq) and 0.05 ± 0.02 Gy/GBq (range, 0.03-0.09 Gy/GBq), respectively. Significant uptake and long tumor retention of 177Lu-FAP-2286 resulted in high absorbed tumor doses, such as 3.0 ± 2.7 Gy/GBq (range, 0.5-10.6 Gy/GBq) in bone metastases. No grade 4 adverse events were observed. Grade 3 events occurred in 3 patients-1 with pancytopenia, 1 with leukocytopenia, and 1 with pain flare-up; 3 patients reported a pain response. Conclusion:177Lu-FAP-2286 PTRT, applied in a broad spectrum of cancers, was relatively well tolerated, with acceptable side effects, and demonstrated long retention of the radiopeptide. Prospective clinical studies are warranted.


Assuntos
Adenocarcinoma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos de Viabilidade , Feminino , Radioisótopos de Gálio , Humanos , Peptídeos , Estudos Prospectivos , Radioisótopos/uso terapêutico , Distribuição Tecidual
11.
Mol Imaging Radionucl Ther ; 30(2): 69-78, 2021 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-34082499

RESUMO

Objectives: Early detection is essential for the treatment approaches of Parkinson's disease (PD). Clinical criteria alone may be insufficient to distinguish early PD from other conditions. This study aimed to investigate the transfer rate constants of 6-18F-fluoro-L-dopa (18F-FDOPA) in positron emission tomography (PET) brain images as a sensitive parameter to detect early PD. Methods: Retrospective 18F-FDOPA PET data of five patients with early PD were collected. PET data were acquired for 90 min after intravenous injection of 306-379 MBq 18F-FDOPA, and reconstructed into a series of 18 five-minute frames. Reoriented PET images were coregistered and normalized with the PET brain template on the statistical parametric mapping. The 18F-FDOPA activity concentrations were measured in the striatum, caudate, and putamen on both sides: Contralateral (as PD) and ipsilateral (as control) to the main motor symptoms. The pharmacokinetic model was generated using the SAAM II simulation software. The transfer rate constants across the blood-brain barrier (forward, K1 and reverse, k2) and decarboxylation rate constants (k3) were estimated in these regions. Results: The activity uptakes in the contralateral striatum (0.0323%±0.0091%) and putamen (0.0169%±0.0054%) were significantly lower than the control (0.0353%±0.0086%, 0.0199%±0.0054%, respectively). The K1 and k3 were significantly lower in the contralateral striatum and putamen (p<0.05). There were no significant differences in any transfer rate constants in the caudate. Conclusion: The transfer rate constants (K1 and k3) of 18F-FDOPA on the contralateral striatum and putamen were significantly lower than the control. These biokinetic data could be potential indicators for quantitative detection of early PD diagnosis.

12.
J Nucl Med ; 62(7): 968-974, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33188151

RESUMO

The objective of this retrospective study was to assess the detection rate (DR), positive predictive value (PPV), and correct detection rate (CDR) of 18F-rhPSMA-7 PET/CT in biochemical recurrence (BCR) of prostate cancer (PCa) after radical prostatectomy (RP) using composite validation. Methods:18F-rhPSMA-7 PET/CT scans of patients with BCR between July 2017 and June 2018 were retrospectively reviewed. All suspicious lesions were recorded. The reference standard was histopathology or combinations of histopathology, imaging, or prostate-specific antigen (PSA) follow up, defined as composite reference standard. DR was calculated as the proportion of PSMA PET-positive patients to all patients independent of the reference standard, whereas the CDR was the percentage of patients who had at least 1 true-positive PSMA PET lesion localized that corresponded with the reference standard. The PPV was defined as the proportion of patients who had true-positive to all positive findings. The correlation between DR and patient characteristics was evaluated. Results: A total of 532 patients with a median PSA level of 0.97 ng/mL (interquartile range: 0.41-2.46 ng/mL) were included. Of these, 162 patients had composite follow-up at a median duration of 5.6 mo (range: 1.1-14.2 mo). The proportion of patients who had no lesion visualized on PET/CT, localized disease, and any distant metastases (M1) were 20%, 43%, and 37%, respectively. PET DR among all patients was 80%. On a per-patient basis, the PPV of 18F-rhPSMA-7 PET/CT in the composite cohort was 88%, and the CDR was 70%. The PPV in the histopathology-proven cohort was 91%, and the CDR in this subgroup was 73%. In patients with PSA levels ≥ 1 ng/mL the DR and PPV were 90% and 91%, respectively, resulting in a CDR of 82%. In patients with PSA levels < 1 ng/mL, the DR and PPV were 69% and 85%, respectively, resulting in a CDR of 59%. There was a significant positive correlation between 18F-rhPSMA-7 PET/CT detection efficacy and stratified PSA levels (P = 0.005), as well as PSA nadir after prostatectomy (P < 0.001). Conclusion:18F-rhPSMA-7 PET/CT offers high PPV in BCR after RP. Its CDR is dependent on the prescan PSA value with excellent CDR in patients with PSA ≥ 1 ng/mL.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Neoplasias da Próstata , Estudos Retrospectivos
13.
Int Urol Nephrol ; 53(2): 359-371, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33128722

RESUMO

PURPOSE: The mortality of dialysis patients treated with high-volume online hemodiafiltration (OL-HDF) is better than hemodialysis, but is still higher than healthy population. Low daily physical activity increases cardiovascular mortality. Addition of intradialytic exercise (IDX) program might improve physical activity and health status in OL-HDF patients. This pilot open-labeled randomized-controlled trial was conducted to evaluate the effects of IDX on physical activity and other clinical parameters in OL-HDF patients. METHODS: Twelve OL-HDF patients were randomized into control (n = 6) or IDX (n = 6) groups. The subjects in IDX group were trained to exercise using a cycle ergometer for 60 min during each OL-HDF session. Physical activity measured as daily step count using a wrist-worn triaxial accelerometer, physical fitness, or cardiorespiratory fitness assessed by VO2max and other physical performance tests, lean body mass determined by the Dual-energy X-ray absorptiometry (DXA), quality of life (QOL), and various parameters were compared between baseline and 6 months. RESULTS: The baseline physical activity status was comparable. Following 6-month IDX, the physical activity was significantly improved in IDX group [+ 1048.79 (+ 741.50, + 2792.54) vs. - 362.06 (- 1626.82, - 167.47) steps/day, p = 0.01], while physical fitness and QOL were unchanged. The lean body mass parameters were preserved in the IDX group while seemed to decrease in the control group. Serum albumin was significantly increased in the IDX group (p = 0.01). The hemoglobin changes were significantly better (p = 0.01) and the erythropoietin resistance index was significantly lower in the IDX group (p = 0.03). Phosphate reduction was significantly greater in the IDX group (p = 0.04). CONCLUSIONS: IDX could improve physical activity and other metabolic parameters in OL-HDF patients and these might contribute to further improvement in clinical and survival outcomes. TRIAL REGISTRATION: ClinicalTrials.gov Registration: NCT03353844.


Assuntos
Composição Corporal , Terapia por Exercício , Exercício Físico , Hemodiafiltração/métodos , Aptidão Física , Adulto , Idoso , Ciclismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
14.
Ann Nucl Med ; 28(7): 674-82, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24889127

RESUMO

OBJECTIVE: The aim of the study was to evaluate the usefulness of (99m)Tc-pertechnetate whole body scan (WBS) with neck and chest SPECT/CT for detection of post-surgical thyroid remnant and metastasis in differentiated thyroid cancer (DTC) patients. METHODS: Fifty-six post total thyroidectomy patients were included. All patients were prospectively imaged with (99m)Tc-pertechnetate WBS with neck and chest SPECT/CT before (131)I ablation. The post-ablative (131)I WBS with SPECT/CT was performed at 5-7 days after receiving (131)I. Both scans were directly compared to determine the concordance of sites and number of remnant and metastasis. RESULTS: Overall per-patient analysis, the percentage of concordance between two scans was 96.4%. In thyroid bed, lymph node, lung and bone subgroups, the percentage of concordance between two scans was 96.4, 92.9, 98.2 and 100%, respectively. All of them show good correlation with unweighted kappa between 0.7 and 1. Overall per-lesion analysis, the percentage of concordance between two scans was 84%. In thyroid bed, lymph node, lung and bone subgroups, the percentage of concordance between two scans was 89.5, 55, 82.6 and 50%, respectively. CONCLUSIONS: Pre-ablative pertechnetate WBS with neck and chest SPECT/CT has good correlation for the detection of post-surgical thyroid remnant, cervical node and discrete lung nodule metastasis as compared to (131)I WBS with SPECT/CT per-patient basis. Because (131)I therapeutic activity is desired base on metastatic site and less concerning about the number of lesions, pre-ablative (99m)Tc-pertechnetate WBS with SPECT/CT was a good alternative tool to avoid radioiodine stunning in post-surgical DTC patients.


Assuntos
Imagem Multimodal , Pertecnetato Tc 99m de Sódio , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/patologia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Imagem Corporal Total , Adulto , Idoso , Feminino , Humanos , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Metástase Neoplásica , Período Pós-Operatório , Radiografia Torácica , Tórax/diagnóstico por imagem , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA