Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 24(1): 37, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-38191302

RESUMO

BACKGROUND: Catheter ablation is recommended in patients with frequent and symptomatic ventricular arrhythmias (VAs) in an otherwise normal heart. Right or left outflow tract (OT) are the most common origins, and catheter ablation is highly effective with low complication rates. However, outcome of catheter ablation of VAs other than the OT (non-OTVAs) is limited. The aim of this single-center study was to assess the safety and mid-term outcome of catheter ablation for non-OTVAs. METHOD AND RESULTS: From 2013 to 2018, 251 patients who underwent catheter ablation for idiopathic non-OTVAs were enrolled and grouped according to the origins including His-Purkinje system (HPS, n = 108), papillary muscle / moderator band (PM/MB, n = 47), tricuspid annulus (TA, n = 70), and mitral annulus (MA, n = 26), 244 (97.2%) had acute elimination of VAs. The time of VAs recurrence of the single procedure was 1.69 (0.12,9.72) months, with 66% occurring within the first 3 months. The recurrence rate was significantly higher in the PM/MB group than in the TA (p = 0.025) and MA groups (p = 0.023). The single procedure success rate in all patients was 70.1%, in which 66.7%, 59.6%, 80%, and 76.9% were achieved in the HPS, PM/MB, TA, and MA groups, respectively (p = 0.284). After multiple procedures, the total success rate was 76.5% at the follow-up of 4.38 ± 2.42 years. The rate was significantly lower in the PM/MB group than in the TA group (p = 0.035). In subgroup analysis, no significant difference was observed in the recurrence rate of single procedure in patients with different VA origins within the PM/MB (log-rank test, p = 0.546). CONCLUSION: Despite a certain percentage of recurrences observed in the mid-term follow-up, catheter ablation remained feasible and effective for idiopathic non-OTVAs.


Assuntos
Ablação por Cateter , Músculos Papilares , Humanos , Ventrículos do Coração , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Valva Mitral
2.
Circ Arrhythm Electrophysiol ; 11(11): e006243, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30571180

RESUMO

BACKGROUND: Several algorithms have been proposed to predict the origin of outflow tract (OT) ventricular arrhythmias (VAs) using standard 12-lead ECG. However, the additive value of right precordial and posterior leads is unknown. METHODS: Standard 12-lead ECG, right precordial leads ECG (V3R, V4R, V5R) and posterior leads ECG (V7, V8, V9) were recorded and analyzed in a development cohort of consecutive patients undergoing OT-VAs ablation at a single center. These findings informed the development of a novel algorithm incorporating right precordial and posterior leads to discriminate between left ventricular OT (LVOT) and right ventricular OT (RVOT) foci. The performance of this novel algorithm which includes the V3R/V7 index was prospectively tested in a validation cohort of consecutive patients undergoing OT-VA ablation at 4 centers and compared with published algorithms. The location of the foci was determined by the successful ablation site. RESULTS: One hundred ninety-one patients were recruited, of which 94 formed the validation cohort (mean age of 45.7±15.6, 39% male, 79% RVOT foci). During OT-VAs, a QS pattern in lead V3R and an S wave in lead V7 were exclusively recorded in RVOT and LVOT foci, respectively. The V3R/V7 index of LVOT origin was significantly greater than that of RVOT (1.05±0.83 versus 0.28±0.23, P<0.001). The V3R/V7 index ≥0.85 predicted an LVOT origin with 87% sensitivity and 96% specificity. In the prospective evaluation, when the V3R/V7 index ≥0.85, an RVOT origin could be excluded with 98.6% accuracy. The area under the curve of V3R/V7 index (0.954) was larger than that of previously reported ECG criteria, including V2S/V3R (0.896), V2 transition ratio (0.792), and transition zone index (0.666). This novel index was also accurate in both patients without obvious LVOT or RVOT origins and subgroups with cardiac rotation or lead V3 R/S transition. CONCLUSIONS: The V3R/V7 index is a novel and accurate ECG criterion that predicts OT-VAs origin.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Ablação por Cateter , Feminino , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA