Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 62(16): E70-E77, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37706891

RESUMO

A phase sensitive optical time domain reflectometry sensing scheme employing a two-stage nonlinear optical preamplification system is proposed to reduce the blind spot effect in Rayleigh scattering by improving the optical power distribution and to enhance the resolution at locations of low-backscatter intensity measurements, providing a higher signal-to-noise ratio for distributed acoustic measurements; the developed system has been tested in-laboratory and on in-field monitoring of a survey well in Cottessen, The Netherlands. The characterization shows strain noise levels below 1 nɛ for a 10 kHz sampling rate.

2.
Br J Surg ; 105(7): 907-917, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29656582

RESUMO

BACKGROUND: Recovery after colonic surgery is invariably delayed by disturbed gut motility. It is commonly assumed that colonic motility becomes quiescent after surgery, but this hypothesis has not been evaluated rigorously. This study quantified colonic motility through the early postoperative period using high-resolution colonic manometry. METHODS: Fibre-optic colonic manometry was performed continuously before, during and after surgery in the left colon and rectum of patients undergoing right hemicolectomy, and in healthy controls. Motor events were characterized by pattern, frequency, direction, velocity, amplitude and distance propagated. RESULTS: Eight patients undergoing hemicolectomy and nine healthy controls were included in the study. Colonic motility became markedly hyperactive in all operated patients, consistently dominated by cyclic motor patterns. Onset of cyclic motor patterns began to a minor extent before operation, occurring with increasing intensity nearer the time of surgery; the mean(s.d.) active duration was 12(7) per cent over 3 h before operation and 43(17) per cent within 1 h before surgery (P = 0.024); in fasted controls it was 2(4) per cent (P < 0·001). After surgery, cyclic motor patterns increased markedly in extent and intensity, becoming nearly continuous (active duration 94(13) per cent; P < 0·001), with peak frequency 2-4 cycles per min in the sigmoid colon. This postoperative cyclic pattern was substantially more prominent than in non-operative controls, including in the fed state (active duration 27(20) per cent; P < 0·001), and also showed higher antegrade velocity (P < 0·001). CONCLUSION: Distal gut motility becomes markedly hyperactive with colonic surgery, dominated by cyclic motor patterns. This hyperactivity likely represents a novel pathophysiological aspect of the surgical stress response. Hyperactive motility may contribute to gut dysfunction after surgery, potentially offering a new therapeutic target to enhance recovery.


Assuntos
Colectomia/efeitos adversos , Colo/fisiopatologia , Motilidade Gastrointestinal , Manometria/métodos , Adolescente , Adulto , Idoso , Colo/cirurgia , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Feminino , Tecnologia de Fibra Óptica , Humanos , Íleus/etiologia , Masculino , Pessoa de Meia-Idade , Periodicidade , Complicações Pós-Operatórias/fisiopatologia , Estresse Fisiológico , Adulto Jovem
3.
Am J Physiol Gastrointest Liver Physiol ; 313(3): G265-G276, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28546283

RESUMO

Slow waves play a central role in coordinating gastric motor activity. High-resolution mapping of extracellular potentials from the stomach provides spatiotemporal detail on normal and dysrhythmic slow-wave patterns. All mapping studies to date have focused exclusively on tissue activation; however, the recovery phase contains vital information on repolarization heterogeneity, the excitable gap, and refractory tail interactions but has not been investigated. Here, we report a method to identify the recovery phase in slow-wave mapping data. We first developed a mathematical model of unipolar extracellular potentials that result from slow-wave propagation. These simulations showed that tissue repolarization in such a signal is defined by the steepest upstroke beyond the activation phase (activation was defined by accepted convention as the steepest downstroke). Next, we mapped slow-wave propagation in anesthetized pigs by recording unipolar extracellular potentials from a high-resolution array of electrodes on the serosal surface. Following the simulation result, a wavelet transform technique was applied to detect repolarization in each signal by finding the maximum positive slope beyond activation. Activation-recovery (ARi) and recovery-activation (RAi) intervals were then computed. We hypothesized that these measurements of recovery profile would differ for slow waves recorded during normal and spatially dysrhythmic propagation. We found that the ARi of normal activity was greater than dysrhythmic activity (5.1 ± 0.8 vs. 3.8 ± 0.7 s; P < 0.05), whereas RAi was lower (9.7 ± 1.3 vs. 12.2 ± 2.5 s; P < 0.05). During normal propagation, RAi and ARi were linearly related with negative unit slope indicating entrainment of the entire mapped region. This relationship was weakened during dysrhythmia (slope: -0.96 ± 0.2 vs -0.71 ± 0.3; P < 0.05).NEW & NOTEWORTHY The theoretical basis of the extracellular gastric slow-wave recovery phase was defined using mathematical modeling. A novel technique utilizing the wavelet transform was developed and validated to detect the extracellular slow-wave recovery phase. In dysrhythmic wavefronts, the activation-to-recovery interval (ARi) was shorter and recovery-to-activation interval (RAi) was longer compared with normal wavefronts. During normal activation, RAi vs. ARi had a slope of -1, whereas the weakening of the slope indicated a dysrhythmic propagation.


Assuntos
Fenômenos Eletrofisiológicos/fisiologia , Motilidade Gastrointestinal/fisiologia , Modelos Biológicos , Músculo Liso/fisiologia , Membrana Serosa/fisiologia , Estômago/fisiologia , Animais , Eletromiografia , Membrana Serosa/citologia , Suínos
4.
Pol J Vet Sci ; 20(2): 277-284, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28865219

RESUMO

Streptococcus suis serotype 2 (SS2) is considered as a major pathogen that causes sepsis and meningitis in piglets and humans, but knowledge of its antigenic proteins remains limited so far. The surface-related proteins of pathogens often play significant roles in bacterium-host interactions and infection. Here, we obtained the elongation factor Tu (EF-Tu) gene of Streptococcus suis and constructed the recombinant expression plasmid successfully. The target recombinant plasmid was then expressed in Escherichia coli and the immuno-protection of the recombinant protein was subsequently evaluated as well. The EF-Tu gene of Streptococcus suis is 1197 bp in length, encodes 398 amino acids. The target recombinant EF-Tu (rEF-Tu) protein can recognize the antiserum of Streptococcus suis and can provoke obvious humoral immune responses in rabbits and conferred protection to rabbits against Streptococcus suis ear-vein challenge, implying that the EF-Tu may be used as an attractive candidate antigen for a component of subunit vaccine.


Assuntos
Proteínas de Bactérias/metabolismo , Regulação Bacteriana da Expressão Gênica/fisiologia , Fator Tu de Elongação de Peptídeos/metabolismo , Streptococcus suis/metabolismo , Animais , Anticorpos Antibacterianos/sangue , Proteínas de Bactérias/genética , Vacinas Bacterianas/imunologia , Clonagem Molecular , Fator Tu de Elongação de Peptídeos/genética , Coelhos , Sorogrupo , Infecções Estreptocócicas/microbiologia , Infecções Estreptocócicas/prevenção & controle , Streptococcus suis/genética , Streptococcus suis/imunologia
5.
Br J Surg ; 103(4): 451-61, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26780492

RESUMO

BACKGROUND: Colorectal resections alter colonic motility, including disruption of control by neural or bioelectrical cell networks. The long-term impact of surgical resections and anastomoses on colonic motor patterns has, however, never been assessed accurately. Fibreoptic high-resolution colonic manometry was employed to define motility in patients who had undergone distal colorectal resection. METHODS: Recruited patients had undergone distal colorectal resections more than 12 months previously, and had normal bowel function. Manometry was performed in the distal colon (36 sensors; 1-cm intervals), with 2-h recordings taken before and after a meal, with comparison to controls. Analysis quantified all propagating events and frequencies (cyclical, short single, and long single motor patterns), including across anastomoses. RESULTS: Fifteen patients and 12 controls were recruited into the study. Coordinated propagating events directly traversed the healed anastomoses in nine of 12 patients with available data, including antegrade and retrograde cyclical, short single and long single patterns. Dominant frequencies in the distal colon were similar in patients and controls (2-3 cycles/min) (antegrade P = 0·482; retrograde P = 0·178). Compared with values before the meal, the mean(s.d.) number of dominant cyclical retrograde motor patterns increased in patients after the meal (2·1(2·7) versus 32·6(31·8) in 2 h respectively; P < 0·001), similar to controls (P = 0·178), although the extent of propagation was 41 per cent shorter in patients, by a mean of 3·4 cm (P = 0·003). Short and long single propagating motor patterns were comparable between groups in terms of frequency, velocity, extent and amplitude. CONCLUSION: Motility patterns and meal responses are restored after distal colorectal resection in patients with normal bowel function. Coordinated propagation across healed anastomoses may indicate regeneration of underlying cellular networks.


Assuntos
Colectomia , Colo/fisiologia , Neoplasias Colorretais/cirurgia , Motilidade Gastrointestinal/fisiologia , Recuperação de Função Fisiológica/fisiologia , Adolescente , Adulto , Idoso , Colonoscopia , Neoplasias Colorretais/fisiopatologia , Feminino , Humanos , Masculino , Manometria , Pessoa de Meia-Idade , Pressão , Prognóstico , Adulto Jovem
6.
Am J Physiol Gastrointest Liver Physiol ; 309(1): G52-8, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25930082

RESUMO

Chronic mesenteric ischemia (CMI) is a challenging clinical problem that is difficult to diagnose noninvasively. Diagnosis early in the disease process would enable life-saving early surgical intervention. Previous studies established that superconducting quantum interference device (SQUID) magnetometers detect the slow wave changes in the magnetoenterogram (MENG) noninvasively following induction of mesenteric ischemia in animal models. The purpose of this study was to assess functional physiological changes in the intestinal slow wave MENG of patients with chronic mesenteric ischemia. Pre- and postoperative studies were conducted on CMI patients using MENG and intraoperative recordings using invasive serosal electromyograms (EMG). Our preoperative MENG recordings showed that patients with CMI exhibited a significant decrease in intestinal slow wave frequency from 8.9 ± 0.3 cpm preprandial to 7.4 ± 0.1 cpm postprandial (P < 0.01) that was not observed in postoperative recordings (9.3 ± 0.2 cpm preprandial and 9.4 ± 0.4 cpm postprandial, P = 0.86). Intraoperative recording detected multiple frequencies from the ischemic portion of jejunum before revascularization, whereas normal serosal intestinal slow wave frequencies were observed after revascularization. The preoperative MENG data also showed signals with multiple frequencies suggestive of uncoupling and intestinal ischemia similar to intraoperative serosal EMG. Our results showed that multichannel MENG can identify intestinal slow wave dysrhythmias in CMI patients.


Assuntos
Eletrodiagnóstico/métodos , Motilidade Gastrointestinal , Jejuno/fisiopatologia , Magnetometria/métodos , Isquemia Mesentérica/diagnóstico , Doença Crônica , Ingestão de Alimentos , Eletromiografia , Humanos , Jejuno/cirurgia , Isquemia Mesentérica/fisiopatologia , Isquemia Mesentérica/cirurgia , Período Pós-Prandial , Valor Preditivo dos Testes , Fatores de Tempo
7.
Physiology (Bethesda) ; 28(5): 310-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23997190

RESUMO

A key discovery in gastrointestinal motility has been the central role played by interstitial cells of Cajal (ICC) in generating electrical slow waves that coordinate contractions. Multielectrode mapping and multiscale modeling are two emerging interdisciplinary strategies now showing translational promise to investigate ICC function, electrophysiology, and contractions in the human gut.


Assuntos
Motilidade Gastrointestinal , Células Intersticiais de Cajal/fisiologia , Intestinos/fisiologia , Modelos Biológicos , Estômago/fisiologia , Pesquisa Translacional Biomédica , Animais , Simulação por Computador , Humanos , Intestinos/citologia , Complexo Mioelétrico Migratório , Estômago/citologia
8.
J Voice ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38614894

RESUMO

PURPOSE: This study investigates (1) the presence of frequency transmission of oscillation from an external whole-body vibration (WBV) platform to the larynx; and (2) the factors that influence this frequency transmission. METHODS: Thirty participants (mean age=22.3years) with normal voice were exposed to four frequency-intensity levels of WBV (10 Hz-10%, 10 Hz-20%, 20 Hz-10%, 20 Hz-20%) and were instructed to produce the natural vowel /a/ three times during each WBV setting. The frequency was extracted from the middle 1-second of each electroglottographic (EGG) signal after passing through a Hann band filter with a range of 6-24 Hz. Linear mixed-effects models were applied to determine the factors that influenced the absolute deviation of the frequency transmission. RESULTS: All participants exhibit an extracted EGG frequency that aligns with the external WBV frequency, deviating by - 0.6 to 1.2 Hz. The absolute deviation of WBV frequency transmission is consistent for both sexes across various WBV settings, except the 10 Hz-10% setting where men tend to exhibit significantly higher deviations (P = 0.018). CONCLUSION: Oscillations at a specific frequency are transmitted from an external WBV platform to the larynx. This study proposes the use of a "spring" system to investigate the effect of WBV on the larynx, and recommends further research to explore the potential of WBV in managing voice disorders.

9.
IEEE Trans Biomed Eng ; 70(10): 2964-2971, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37130253

RESUMO

OBJECTIVE: Abnormal slow-wave activity has been associated with functional motility disorders. Gastric pacing has been investigated to correct slow-wave abnormalities, but clinical therapies are yet to be established. This study aimed to define optimal parameters to advance the application of gastric pacing. METHODS: High-resolution gastric mapping was utilized to evaluate four pacing parameters in in-vivo pig studies: (i) orientation of the pacing electrodes (longitudinal vs circumferential), (ii) pacing energy (900 vs 10,000 ms mA2), (iii) the pacing location (corpus vs antrum), and (iv) pacing period (between 12 and 36 s). RESULTS: The probability of slow-wave initiation and entrainment with the pacing electrodes oriented longitudinally was significantly higher than with electrodes orientated circumferentially (86 vs 10%). High-energy pacing accelerated entrainment over the entire mapped field compared to low-energy pacing (3.1±1.5 vs 7.3±2.4 impulses, p < 0.001). Regardless of the location of the pacing site, the new site of slow-wave initiation was always located 4-12 mm away from the pacing site, between the greater curvature and negative pacing electrode. A pacing period between 14-30 s resulted in stable slow-wave initiation and entrainment. CONCLUSION: These data will now inform effective application of gastric pacing in future studies, including human translation.


Assuntos
Motilidade Gastrointestinal , Estômago , Humanos , Animais , Suínos , Eletrodos , Cognição
10.
Exp Physiol ; 102(1): 135, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28044406
11.
Clin Anat ; 23(3): 287-96, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20169612

RESUMO

The aim of this study was to obtain detailed information regarding the three-dimensional structure of the gastro-oesophageal region, and, in particular, the fiber orientation of the different muscle layers of the junction. This was achieved by a study of an en bloc resection of the gastro-oesophageal junction (GOJ) harvested from a human cadaver. The excised tissue block was suspended in a cage to preserve anatomical relationships, fixed in formalin and embedded in wax. The tissue block was then processed by a custom-built extended-volume imaging system to obtain the microstructural information using a digital camera which acquires images at a resolution of 8.2 microm/pixel. The top surface of the tissue block was sequentially stained and imaged. At each step, the imaged surface was milled off at a depth of 50 microm. The processing of the tissue block resulted in 650 images covering a length of 32.25 mm of the GOJ. Structures, including the different muscle and fascial layers, were then traced out from the cross-sectional images using color thresholding. The traced regions were then aligned and assembled to provide a three-dimensional representation of the GOJ. The result is the detailed three-dimensional microstructural anatomy of the GOJ represented in a new way. The next stage will be to integrate key physiological events, including peristalsis and relaxation, into this model using mathematical modeling to allow accurate visual tools for training health professionals and patients.


Assuntos
Junção Esofagogástrica/ultraestrutura , Humanos , Imageamento Tridimensional , Masculino , Adulto Jovem
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4787-4790, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33019061

RESUMO

Control schemes that rely on electromyography (EMG) pattern classification have shown to improve their accuracy when coupled with an increasing number of electrodes. In this study, HD-EMG signals from the hand and forearm of volunteers performing a series of movements were recorded. Different amounts of input EMG channels were selected and time-domain features were extracted to train several SVM classifiers. Detailed comparisons were made to evaluate the impact of electrode count and feature selection over the overall classification accuracy of 17 different movements. The increased resolution achieved from higher electrode counts yielded significant improvements in classification accuracy; however, these improvements were marginal when the number of channels utilized surpassed 100 electrodes.Clinical relevance- Pattern-based EMG classification is a widely used control method for a range of prosthetic devices and robotic interfaces. This work studies the optimal number of simultaneous HD-EMG channels and features that must be considered for accurate myoelectric control using this method.


Assuntos
Algoritmos , Reconhecimento Automatizado de Padrão , Eletrodos , Eletromiografia , Humanos , Movimento
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 2504-2507, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018515

RESUMO

A potential treatment option for chronic and severe motility disorders such as gastroparesis is the implantation of a Gastric Electrical Stimulator (GES), which is designed to modulate the bio-electric slow waves. However, the effectiveness of current GESs remains uncertain since they do not work in a closed-loop by sensing, processing, and modulating the dysrhythmic patterns. This work presents the design of a GES model working in closed-loop with the network of the Interstitial Cells of Cajal (ICC). A pre-existing two-dimensional ICC network is enhanced by proposing an extracellular potential generation model, which can precisely capture the timing behaviour of slow wave propagation pattern of the simulated ICC network. The GES senses the extracellular potential, detects bradygastric patterns and finally modulates the activity to ensure normal conduction. The GES is designed to be practical for ease of validation and implementation.


Assuntos
Gastroparesia , Arritmias Cardíacas , Eletricidade , Gastroparesia/terapia , Humanos , Masculino , Próteses e Implantes
14.
Am J Physiol Gastrointest Liver Physiol ; 297(4): G672-80, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19661149

RESUMO

Gastric electrical stimulation (GES) involves the delivery of electrical impulses to the stomach for therapeutic purposes. New GES protocols are needed that are optimized for improved motility outcomes and energy efficiency. In this study, a biophysically based smooth muscle cell (SMC) model was modified on the basis of experimental data and employed in conjunction with experimental studies to define the effects of a large range of GES protocols on individual SMCs. For the validation studies, rat gastric SMCs were isolated and subjected to patch-clamp analysis during stimulation. Experimental results were in satisfactory agreement with simulation results. The results define the effects of a wide range of GES parameters (pulse width, amplitude, and pulse-train frequency) on isolated SMCs. The minimum pulse width required to invoke a supramechanical threshold response from SMCs (defined at -30 mV) was 65 ms (at 250-pA amplitude). The minimum amplitude required to invoke this threshold was 75 pA (at 1,000-ms pulse width). The amplitude of the invoked response beyond this threshold was proportional to the stimulation amplitude. A high-frequency train of stimuli (40 Hz; 10 ms, 150 pA) could invoke and maintain the SMC plateau phase while requiring 60% less power and accruing approximately 30% less intracellular Ca(2+) concentration during the plateau phase than a comparable single-pulse protocol could in a demonstrated example. Validated computational simulations are an effective strategy for efficiently identifying effective minimum-energy GES protocols, and pulse-train protocols may also help to reduce the power consumption of future GES devices.


Assuntos
Simulação por Computador , Terapia por Estimulação Elétrica , Esvaziamento Gástrico , Modelos Biológicos , Miócitos de Músculo Liso/fisiologia , Estômago/fisiologia , Animais , Cálcio/metabolismo , Terapia por Estimulação Elétrica/métodos , Potenciais Evocados , Masculino , Técnicas de Patch-Clamp , Ratos , Estômago/citologia , Fatores de Tempo
15.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6229-6232, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947266

RESUMO

Electromyography (EMG) based control systems rely on the accurate identification of patterns extracted from signal features to predict the corresponding movement. The selection of segmentation window parameters and their impact on overall accuracy of classifiers has been previously studied for systems with a low number of EMG channels (<; 16). In this study a High-density EMG electrode array was used to evaluate the impact of the parameters when a high number of channels (128) was recorded. Findings show that in combination with high channel counts the impact of window length and overlap were marginal (<; 2% and <; 1% respectively). The number of channels was found to have direct correlation with achieved accuracy, with an improvement of up to 19.5 ± 4.5% in classification accuracy when increasing from 4 to 128 channels.


Assuntos
Algoritmos , Eletromiografia , Reconhecimento Automatizado de Padrão , Eletrodos , Humanos , Movimento
16.
Neurogastroenterol Motil ; 30(7): e13310, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29493080

RESUMO

BACKGROUND: Bioelectrical slow waves are a coordinating mechanism of small intestine motility, but extracellular human studies have been restricted to a limited number of sparse electrode recordings. High-resolution (HR) mapping has offered substantial insights into spatiotemporal intestinal slow wave dynamics, but has been limited to animal studies to date. This study aimed to translate intra-operative HR mapping to define pacemaking and conduction profiles in the human small intestine. METHODS: Immediately following laparotomy, flexible-printed-circuit arrays were applied around the serosa of the proximal jejunum (128-256 electrodes; 4-5.2 mm spacing; 28-59 cm2 ). Slow wave propagation patterns were mapped, and frequencies, amplitudes, downstroke widths, and velocities were calculated. Pacemaking and propagation patterns were defined. KEY RESULTS: Analysis comprised nine patients with mean recording duration of 7.6 ± 2.8 minutes. Slow waves occurred at a frequency of 9.8 ± 0.4 cpm, amplitude 0.3 ± 0.04 mV, downstroke width 0.5 ± 0.1 seconds, and with faster circumferential velocity than longitudinal (10.1 ± 0.8 vs 9.0 ± 0.7 mm/s; P = .001). Focal pacemakers were identified and mapped (n = 4; mean frequency 9.9 ± 0.2 cpm). Disordered slow wave propagation was observed, including wavefront collisions, conduction blocks, and breakout and entrainment of pacemakers. CONCLUSIONS & INFERENCES: This study introduces HR mapping of human intestinal slow waves, and provides first descriptions of intestinal pacemaker sites and velocity anisotropy. Future translation to other intestinal regions, disease states, and postsurgical dysmotility holds potential for improving the basic and clinical understanding of small intestine pathophysiology.


Assuntos
Motilidade Gastrointestinal/fisiologia , Jejuno/fisiologia , Laparotomia/métodos , Monitorização Intraoperatória/métodos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Eletrodos , Estudos de Viabilidade , Feminino , Humanos , Jejuno/cirurgia , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação
17.
Artigo em Inglês | MEDLINE | ID: mdl-28695661

RESUMO

BACKGROUND: Gastric slow wave dysrhythmias are accompanied by deviations in frequency, velocity, and extracellular amplitude, but the inherent association between these parameters in normal activity still requires clarification. This study quantified these associations using a joint experimental-theoretical approach. METHODS: Gastric pacing was conducted in pigs with simultaneous high-resolution slow wave mapping (32-256 electrodes; 4-7.6 mm spacing). Relationships between period, velocity, and amplitude were quantified and correlated for each wavefront. Human data from two existing mapping control cohorts were analyzed to extract and correlate these same parameters. A validated biophysically based ICC model was also applied in silico to quantify velocity-period relationships during entrainment simulations and velocity-amplitude relationships from membrane potential equations. KEY RESULTS: Porcine pacing studies identified positive correlations for velocity-period (0.13 mm s-1 per 1 s, r2 =.63, P<.001) and amplitude-velocity (74 µV per 1 mm s-1 , r2 =.21, P=.002). In humans, positive correlations were also quantified for velocity-period (corpus: 0.11 mm s-1 per 1 s, r2 =.16, P<.001; antrum: 0.23 mm s-1 per 1 s, r2 =.55; P<.001), and amplitude-velocity (94 µV per 1 mm s-1 , r2 =.56; P<.001). Entrainment simulations matched the experimental velocity-period relationships and demonstrated dependence on the slow wave recovery phase. Simulated membrane potential relationships were close to these experimental results (100 µV per 1 mm s-1 ). CONCLUSIONS AND INFERENCES: These data quantify the relationships between slow wave frequency, velocity, and extracellular amplitude. The results from both human and porcine studies were in keeping with biophysical models, demonstrating concordance with ICC biophysics. These relationships are important in the regulation of gastric motility and will help to guide interpretations of dysrhythmias.


Assuntos
Motilidade Gastrointestinal , Células Intersticiais de Cajal/fisiologia , Modelos Biológicos , Estômago/fisiologia , Animais , Fenômenos Biofísicos , Feminino , Humanos , Suínos
18.
Opt Express ; 15(19): 12529-38, 2007 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-19547623

RESUMO

An important measuring technique under study for the DARWIN planet finding mission, is nulling interferometry, enabling the detection of the weak infrared emission lines of an orbiting planet. This technique requires a perfect wavefront of the light beams to be combined in the interferometer. By using a single mode waveguide before detection, wavefront errors are filtered and a virtually perfect plane wavefront is obtained. In this paper the results on the development and the optical characterisation of suitable infrared transmitting chalcogenide glasses and mid-IR guiding optical fibers are reported. Two different perform techniques for manufacturing core-cladding chalcogenide fibers are described. Two types of step index fibers, prepared with Te(2)As(3)Se(5) chalcogenide glasses, offer single mode guidance at 10.6 mum.

19.
Artigo em Inglês | MEDLINE | ID: mdl-28035728

RESUMO

BACKGROUND: Gastric motility is coordinated by bioelectrical slow waves, and gastric dysrhythmias are reported in motility disorders. High-resolution (HR) mapping has advanced the accurate assessment of gastric dysrhythmias, offering promise as a diagnostic technique. However, HR mapping has been restricted to invasive surgical serosal access. This study investigates the feasibility of HR mapping from the gastric mucosal surface. METHODS: Experiments were conducted in vivo in 14 weaner pigs. Reference serosal recordings were performed with flexible-printed-circuit (FPC) arrays (128-192 electrodes). Mucosal recordings were performed by two methods: (i) FPC array aligned directly opposite the serosal array, and (ii) cardiac mapping catheter modified for gastric mucosal recordings. Slow-wave propagation and morphology characteristics were quantified and compared between simultaneous serosal and mucosal recordings. KEY RESULTS: Slow-wave activity was consistently recorded from the mucosal surface from both electrode arrays. Mucosally recorded slow-wave propagation was consistent with reference serosal activation pattern, frequency (P≥.3), and velocity (P≥.4). However, mucosally recorded slow-wave morphology exhibited reduced amplitude (65-72% reduced, P<.001) and wider downstroke width (18-31% wider, P≤.02), compared to serosal data. Dysrhythmias were successfully mapped and classified from the mucosal surface, accorded with serosal data, and were consistent with known dysrhythmic mechanisms in the porcine model. CONCLUSIONS & INFERENCES: High-resolution gastric electrical mapping was achieved from the mucosal surface, and demonstrated consistent propagation characteristics with serosal data. However, mucosal signal morphology was attenuated, demonstrating necessity for optimized electrode designs and analytical algorithms. This study demonstrates feasibility of endoscopic HR mapping, providing a foundation for advancement of minimally invasive spatiotemporal gastric mapping as a clinical and scientific tool.


Assuntos
Eletrofisiologia/métodos , Motilidade Gastrointestinal , Mucosa/fisiologia , Membrana Serosa/fisiologia , Animais , Eletrodos , Fenômenos Eletrofisiológicos , Eletrofisiologia/instrumentação , Feminino , Processamento de Sinais Assistido por Computador , Suínos
20.
Neurogastroenterol Motil ; 28(6): 837-48, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26839980

RESUMO

BACKGROUND: Gastroparesis is characterized by delayed gastric emptying without mechanical obstruction, but remains difficult to diagnose and distinguish from other gastrointestinal (GI) disorders. Gastroparesis affects the gastric slow wave, but non-invasive assessment has been limited to the electrogastrogram (EGG), which reliably characterizes temporal dynamics but does not provide spatial information. METHODS: We measured gastric slow wave parameters from the EGG and magnetogastrogram (MGG) in patients with gastroparesis and in healthy controls. In addition to dominant frequency (DF) and percentage power distribution (PPD), we measured the propagation velocity from MGG spatiotemporal patterns and the percentage of slow wave coupling (%SWC) from EGG. KEY RESULTS: No significant difference in DF was found between patients and controls. Gastroparesis patients had lower percentages of normogastric frequencies (60 ± 6% vs 78 ± 4%, p < 0.05), and higher brady (9 ± 2% vs 2 ± 1%, p < 0.05) and tachygastric (31 ± 2% vs 19 ± 1%, p < 0.05) frequency content postprandial, indicative of uncoupling. Propagation patterns were substantially different in patients and longitudinal propagation velocity was retrograde at 4.3 ± 2.9 mm/s vs anterograde at 7.4 ± 1.0 mm/s for controls (p < 0.01). No difference was found in %SWC from EGG. CONCLUSIONS & INFERENCES: Gastric slow wave parameters obtained from MGG recordings distinguish gastroparesis patients from controls. Assessment of slow wave propagation may prove critical to characterization of underlying disease processes. Future studies should determine pathologic indicators from MGG associated with other functional gastric disorders, and whether multichannel EGG with appropriate signal processing also reveals pathology.


Assuntos
Diabetes Mellitus/diagnóstico , Diabetes Mellitus/fisiopatologia , Motilidade Gastrointestinal/fisiologia , Gastroparesia/diagnóstico , Gastroparesia/fisiopatologia , Adulto , Feminino , Esvaziamento Gástrico/fisiologia , Gastroparesia/complicações , Humanos , Magnetometria/métodos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA