Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Geriatr Nurs ; 53: 247-254, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37598428

RESUMO

This study aimed to examine the relationship between self-perceived quality of transitional care and functional outcome among patients with stroke and fractures. The Care Transition Measure (CTM-15) was used to survey patient's self-perceived transitional care quality before discharge. General estimating equations were used to investigate the influences of transitional care quality on patient's functional outcomes at before, 1 week after, and 1 or 3 months after discharge. Among stroke patients, higher CTM-15 scores were positively associated with greater outcome in Instrumental Activities of Daily Living (IADL) following discharge. Higher scores for "reader-friendly written care plan," "consideration of patient's preferences," and "understanding of health management" had significantly positive effects on functional recovery in IADL among both patient groups following discharge. These findings suggest that heterogeneity in transitional care needs between medical and surgical patients shall not be overlooked. A one-size-fits-all strategy may be insufficient for ensuring patient care continuity following discharge.


Assuntos
Acidente Vascular Cerebral , Cuidado Transicional , Humanos , Atividades Cotidianas , Taiwan , Alta do Paciente , Acidente Vascular Cerebral/terapia , Percepção
2.
J Orthop Traumatol ; 23(1): 40, 2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-35978204

RESUMO

BACKGROUND: The aim of this study was to compare two techniques for the surgical treatment of diaphyseal fractures in the adult humerus: double-crossed retrograde elastic stable intramedullary nailing (DCR-ESIN) and limited-contact dynamic compression plate (LC-DCP). METHODS: This was a retrospective study conducted at a single hospital. We included 122 patients with diaphyseal fractures of the humerus who had received DCR-ESIN or LC-DCP from January 2011 to January 2017. We compared union rates, union times, disabilities of the arm, shoulder, and hand (DASH) scores at the postoperative 1-year follow-up, and complications between the two groups. RESULTS: Plating management was performed in 63 patients, while DCR-ESIN was performed in 59 patients. The union rate was higher in the DCR-ESIN group than in the LC-DCP group (100% vs. 90.5%; p = 0.052). The union time was shorter in the DCR-ESIN group than in the LC-DCP group (12.0 weeks vs. 14.8 weeks; p < 0.001). The intraoperative blood loss and operative time were less in the DCR-ESIN group than in the LC-DCP group (76.4 min vs. 129.5 min; p < 0.001; 60.9 ml vs. 244.8 ml; p < 0.001, respectively). The DCR-ESIN had superior results for the rate of overall complications (p = 0.006). At the 1-year follow-up, the DCR-ESIN group had better DASH scores than the LC-DCP group (p = 0.014). CONCLUSIONS: The DCR-ESIN technique, used to treat diaphyseal fractures of the humerus, has shorter operative times, less intra-operative blood loss, shorter union times, and better functional outcomes at 1-year follow-up than the LC-DCP technique. DCR-ESIN may be an alternative method for the surgical treatment of diaphyseal humeral fractures in adults.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Úmero , Adulto , Pinos Ortopédicos , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
Arthroscopy ; 36(10): 2738-2747, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32497657

RESUMO

PURPOSE: To evaluate the surgical outcome in terms of radiographic measurements, functional outcomes, and complications following arthroscopic ankle arthrodesis (AAA) in patients 60 years of age or older, and to compare the results of patients with mildly deformed ankle with those of patients with severely deformed ankle. METHODS: We retrospectively reviewed patients who underwent AAA with 3 cannulated screws between January 2008 and December 2017 and followed postoperatively for at least 24 months. All included patients were 60 years of age or older. Demographic data and radiographic and functional outcomes were compared between patients with coronal deformity of less than 15° (group I) and those with a deformity equal to or greater than 15 degrees (group II). RESULTS: A total of 41 patients with a mean age of 70.6 years were included (group I, n = 26; group II, n = 15) and mean follow-up was 51.4 months. Group II had significantly more severe preoperative coronal deformity of tibiotalar angle than group I (20.1 ± 2.9 vs 6.6 ± 4.1°, P < .01). Near-normal tibiotalar alignment was achieved postoperatively in both groups (group I, 3.4 ± 3.3 vs group II, 4.7 ± 3.1°, P = .227). Union was achieved in 39 (95.1%) patients with 2 cases in group I experiencing non-union. Union rate, mean American Orthopaedic Foot and Ankle Society ankle-hindfoot scale, and visual analog scale pain scores were not significantly different between the 2 groups at final follow-up. CONCLUSIONS: AAA is a reliable procedure for end-stage ankle arthritis in patients 60 years of age or older resulting in a high union rate, encouraging radiographic and functional outcomes, and a low complication rate, even in cases with severe preoperative deformity. In addition, arthroscopic intra-articular malleolar osteotomy was a useful technique for correcting severe coronal deformity in our series. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Assuntos
Articulação do Tornozelo/cirurgia , Tornozelo/diagnóstico por imagem , Tornozelo/cirurgia , Artrite/cirurgia , Artrodese/métodos , Artroscopia/métodos , Idoso , Tornozelo/anormalidades , Articulação do Tornozelo/diagnóstico por imagem , Artrite/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteotomia/métodos , Satisfação do Paciente , Estudos Retrospectivos , Resultado do Tratamento
4.
Foot Ankle Surg ; 26(2): 193-197, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30796000

RESUMO

BACKGROUND: The aim of this study was to compare the radiographic and functional results between fixation and non-fixation in the Cotton osteotomy for the treatment of adult acquired flatfoot. METHODS: A retrospective, case-controlled study of consecutive stage IIB posterior tibial tendon dysfunction (PTTD) patients treated with the same bony reconstructive surgery including cotton osteotomy between 2013 and 2017. Meary's angle, the medial arch sag angle (MASA), and medial cuneiform cobb angle (MCCA) were evaluated pre-operation, at first weight bearing after surgery, and 12 months post operation. RESULTS: Forty feet were included in the study. The cotton osteotomy utilized screw fixation (n = 20) or non-fixation technique (n = 20). No significant differences between groups were found in pre-operative and follow-up radiographic parameters, union rate, and functional results. CONCLUSION: The non-fixation with press fit technique is a reliable procedure for Cotton osteotomy and as effective as screw fixation. LEVEL OF EVIDENCE: Level III, case control study.


Assuntos
Artrodese/métodos , Parafusos Ósseos , Pé Chato/cirurgia , Osteotomia , Disfunção do Tendão Tibial Posterior/cirurgia , Ossos do Tarso/cirurgia , Adulto , Idoso , Artrodese/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Suporte de Carga
5.
Arthroscopy ; 35(9): 2671-2683, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31500754

RESUMO

PURPOSE: To describe an algorithm for arthroscopic reduction and minimally invasive surgery (ARMIS) and compare the surgical outcomes with standard open reduction-internal fixation (ORIF) for the treatment of supination-external rotation (SER) ankle fractures. METHODS: The inclusion criteria for this study were patients aged 16 years or older, the presence of a unilateral SER fracture, and injuries less than 2 weeks old. We retrospectively identified patients with SER fractures who underwent ORIF from January 2008 to December 2011 or ARMIS from January 2012 to December 2015. Data collected in December 2013 for the ORIF group and in December 2017 for the ARMIS group were compared. The algorithm for ARMIS was minimally invasive plating for lateral malleolar fractures first, followed by ankle arthroscopy for detection of syndesmotic injuries and then arthroscopic reduction of medial malleolar fractures or mini-open repair of the deltoid ligament. The talocrural angle, fibular length, tibiomedial malleolar angle, medial clear space, and tibiofibular clear space were measured radiographically. Functional evaluations included the visual analog scale pain score, American Orthopaedic Foot & Ankle Society ankle-hindfoot scales, and range of motion of bilateral ankles. Complications and reoperations were recorded for comparison. RESULTS: A total of 105 patients with SER fractures, 65 in the ARMIS group and 40 in the ORIF group, were included. Significantly lower incidences of complications (7.7% vs 27.5%, P = .006) and reoperations (1.5% vs 12.5%, P = .029) were found in the ARMIS group than in the ORIF group. More syndesmotic injuries were detected in the ARMIS group than in the ORIS group (80% vs 57.5%, P = .021). The visual analog scale pain score was significantly lower on day 3 postoperatively in the ARMIS group than in the ORIS group (1.96 ± 1.18 vs 2.83 ± 1.07, P = .027). The postoperative stay was shorter in the ARMIS group than in the ORIF group (3.66 ± 1.39 days vs 4.46 ± 2.23 days, P = .024). The operative time was longer in the ARMIS group than in the ORIS group (105.22 ± 27.13 minutes vs 93.59 ± 22.79 minutes, P = .038). A longer fluoroscopic time (0.43 ± 0.25 minutes vs 0.17 ± 0.07 minutes, P < .001) and a higher dose of irradiation (1,216.46 ± 603.99 µGy vs 389.38 ± 217.89 µGy, P < .001) were observed in the ARMIS group. No significant differences in radiographic measurements were found between the operative and nonoperative ankles in both groups. CONCLUSIONS: Our algorithm and the ARMIS techniques may be a safe, reliable, and effective option in the treatment of SER fractures. ARMIS achieves promising surgical outcomes with less early postoperative pain, a shorter postoperative stay, and lower incidences of complications and reoperations compared with ORIF. However, the operative time is longer and the irradiation dose is higher with the ARMIS techniques. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Assuntos
Fraturas do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artroscopia/métodos , Fixação Interna de Fraturas/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Redução Aberta/métodos , Amplitude de Movimento Articular/fisiologia , Adolescente , Adulto , Idoso , Fraturas do Tornozelo/diagnóstico , Fraturas do Tornozelo/fisiopatologia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiopatologia , Placas Ósseas , Parafusos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Supinação , Resultado do Tratamento
6.
J Shoulder Elbow Surg ; 27(2): 224-230, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29054381

RESUMO

BACKGROUND: Treatment of displaced distal clavicular fractures is still controversial. This study reports the utility of a new coracoclavicular (CC) loop technique for acute displaced distal clavicular fractures and compared its surgical outcomes with those of the hook plate method. METHODS: In this retrospective study, a total of 23 patients with acute displaced distal clavicular fractures were treated with a new CC loop technique at a single institution from 2010 to 2014. Another group comprising 49 patients treated with a hook plate was compared with the CC loop group regarding clinical and radiologic outcomes. RESULTS: Seventy-two patients with at least 1 year of follow-up after both operations were included in this study. The Constant score was significantly greater in the CC loop group (95 vs 87, P = .009) at final follow-up. Moreover, the complication rate was significantly lower in the CC loop group (0% vs 24.5%, P = .007). The University of California, Los Angeles shoulder score and radiologic nonunion rate revealed no significant differences between the 2 groups. CONCLUSIONS: The new CC loop technique had better clinical outcomes and lower complication rates compared with the hook plate technique.


Assuntos
Placas Ósseas , Clavícula/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Adulto , Clavícula/lesões , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
7.
Phys Chem Chem Phys ; 18(30): 20371-80, 2016 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-27401818

RESUMO

This paper reports on the fabrication of low-k (amorphous) silica thin films cast from solutions without and with two different types of surfactants (TWEEN® 80 and Triton™ X-100) to elucidate the relationships between the structural/morphological features of the casting solutions and the physical properties of the resulting thin films. Cryogenic transmission microscopy (cryo-TEM), static/dynamic light scattering (SLS/DLS), and small-angle X-ray scattering (SAXS) revealed contrasting colloidal dispersion states and phase behavior among the three casting solutions. Casting solution with the Triton™ X-100 surfactant produced stable (>90 days) nanoparticles with good dispersion in solution (mean particle size ∼10 nm) as well as good mesopore volume (characterized by nitrogen physisorption) in powder and thin films of high mechanical strength (characterized by the nanoindentation test). The longer main chain and bulkier side units of the TWEEN® 80 surfactant led to stable micelle-nanoparticle coexisting dispersion, which resulted in the highest mesopore volume in powder and thin films with the lowest dielectric constant (∼3) among the samples in this study. The casting solution without the surfactant failed to produce a stabilized solution or thin films of acceptable uniformity. These findings demonstrate the possibility of fine-tuning low-k silica film properties by controlling the colloidal state of casting solutions.

8.
Arch Phys Med Rehabil ; 96(12): 2120-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26340807

RESUMO

OBJECTIVES: To investigate the effects of ultrasound-guided injections of hyaluronic acid (HA) versus steroid for trigger fingers in adults. DESIGN: Prospective, double-blinded, randomized controlled study. SETTING: Tertiary care center. PARTICIPANTS: Subjects with a diagnosis of trigger finger (N=36; 39 affected digits) received treatment and were evaluated. INTERVENTIONS: Subjects were randomly assigned to HA and steroid injection groups. Both study medications were injected separately via ultrasound guidance with 1 injection. MAIN OUTCOME MEASURES: The classification of trigger grading, pain, functional disability, and patient satisfaction were evaluated before the injection and 3 weeks and 3 months after the injection. RESULTS: At 3 months, 12 patients (66.7%) in the HA group and 17 patients (89.5%) in the steroid group exhibited no triggering of the affected fingers (P=.124). The treatment results at 3 weeks and 3 months showed similar changes in the Quinnell scale (P=.057 and .931, respectively). A statistically significant interaction effect between group and time was found for visual analog scale (VAS) and Michigan Hand Outcome Questionnaire (MHQ) evaluation (P<.05). The steroid group had a lower VAS at 3 months after injection (steroid 0.5±1.1 vs HA 2.7±2.4; P<.001). The HA group demonstrated continuing significant improvement in MHQ at 3 months (change from 3wk: steroid -2.6±14.1 vs HA 19.1±37.0; P=.023; d=.78). CONCLUSIONS: Ultrasound-guided injection of HA demonstrated promising results for the treatment of trigger fingers. The optimal frequency, dosage, and molecular weight of HA injections for trigger fingers deserve further investigation for future clinical applications.


Assuntos
Anti-Inflamatórios/uso terapêutico , Ácido Hialurônico/uso terapêutico , Triancinolona/uso terapêutico , Dedo em Gatilho/tratamento farmacológico , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios/administração & dosagem , Método Duplo-Cego , Feminino , Humanos , Ácido Hialurônico/administração & dosagem , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Estudos Prospectivos , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Triancinolona/administração & dosagem
10.
Micromachines (Basel) ; 15(4)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38675265

RESUMO

In this study, the fabrication of microfluidic chips through the bonding of poly (methyl methacrylate) (PMMA) boards featuring designed patterns to create a three-dimensional sandwich structure with embedded microchannels was explored. A key focus was optimization of the interface quality of bonded PMMA pairs by adjusting the solvent, such as such as acetone, alcohol, and their mixture. Annealing was conducted below 50 °C to leverage the advantages of low-temperature bonding. Because of the differences in the chemical reactivity of PMMA toward acetone, alcohol, and their combinations, the resulting defect densities at the bonding interfaces differed significantly under low-temperature annealing conditions. To achieve the optimal sealing integrity, bonding pressures of 30 N, 40 N, and 50 N were evaluated. The interface was analyzed through microstructural examination via optical microscopy and stress measurements were determined using digital photoelasticity, while the bonding strength was assessed through tensile testing.

11.
Biosensors (Basel) ; 14(6)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38920585

RESUMO

Oral cancer represents a significant global public health challenge, contributing substantially to the incidence and mortality of cancer. Despite established risk factors such as tobacco use and alcohol consumption, early detection remains crucial for effective treatment. This study introduces a novel approach using a transistor-based biosensor system for detecting the P90 (CIP2A) protein. We tested the presence of CIP2A in human leukoplakia samples, which can undergo malignant conversion into aggressive oral squamous cell carcinoma. The method used commercially available glucose test strips functionalized with P90 antibodies, providing high sensitivity and a low limit of detection which was five orders lower than that of commercial ELISA kits. A specially designed printed circuit board (PCB) facilitated accurate measurements, and the device's performance was optimized through characteristic tests. Human sample testing validated the biosensor's effectiveness in distinguishing samples after cell lysis. This study contributes to advancing accurate and cost-effective diagnostic approaches for oral pre-cancer and cancer tissues.


Assuntos
Técnicas Biossensoriais , Leucoplasia Oral , Saliva , Humanos , Leucoplasia Oral/diagnóstico , Saliva/química , Biomarcadores Tumorais/análise , Proteínas de Membrana , Neoplasias Bucais/diagnóstico , Ensaio de Imunoadsorção Enzimática
12.
Artigo em Inglês | MEDLINE | ID: mdl-38362284

RESUMO

The prevalence of breast cancer in women underscores the urgent need for innovative and efficient detection methods. This study addresses this imperative by harnessing salivary biomarkers, offering a noninvasive and accessible means of identifying breast cancer. In this study, commercially available disposable based strips similar to the commonly used glucose detection strips were utilized and functionalized to detect breast cancer with biomarkers of HER2 and CA15-3. The results demonstrated limits of detection for these two biomarkers reached as low as 1 fg/ml much lower than those of conventional enzyme-linked immunosorbent assay in the range of 1∼4 ng/ml. By employing a synchronized double-pulse method to apply 10 of 1.2 ms voltage pulses to the electrode of sensing strip and drain electrode of the transistor for amplifying the detected signal, and the detected signal was the average of 10 digital output readings corresponding to those 10 voltage pulses. The sensor sensitivities were achieved approximately 70/dec and 30/dec for HER2 and CA15-3, respectively. Moreover, the efficiency of this novel technique is underscored by its swift testing time of less than 15 ms and its minimal sample requirement of only 3 µl of saliva. The simplicity of operation and the potential for widespread public use in the future position this approach as a transformative tool in the early detection of breast cancer. This research not only provides a crucial advancement in diagnostic methodologies but also holds the promise of revolutionizing public health practices.

14.
Foot Ankle Int ; 34(4): 550-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23463777

RESUMO

BACKGROUND: Tricortical autograft has been commonly used in subtalar distraction arthrodesis (SDA) for severe calcaneal malunion. Structural allograft enriched with orthobiological agents is an alternative. This study was performed to evaluate the results of SDA using fresh-frozen allogeneic femoral head without the addition of orthobiological agents. MATERIALS AND METHODS: We retrospectively reviewed 15 consecutive SDA procedures (13 patients) with allogeneic femoral head augmented with local autograft for the treatment of severe calcaneal malunion. Clinical outcome was evaluated with the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot score, visual analog scale (VAS) pain score, Short Form-12 (SF-12), range of motion (ROM) of the ankle joint, and patient satisfaction rate. Radiographic assessment included the talar declination angle (TDA), calcaneal inclination angle (CIA), lateral talocalcaneal angle (LTCA), heel height, calcaneal length, and union time. RESULTS: At a median follow-up of 36.0 months (range, 24-47 months), all 15 feet (100%) achieved union, at a median of 13.0 weeks (range, 12-18 weeks). The AOFAS score and VAS pain score improved significantly, with a satisfaction rate of 93.3%. The TDA, CIA, LTCA, and heel height improved significantly. The median increase in heel height was 8.6 mm (range, 1.9-20.1 mm). There was a significant reduction in calcaneal length. Complications included 1 varus malalignment, 1 complex regional pain syndrome, 1 hardware irritation, and 1 sural neuralgia. CONCLUSION: This study found that SDA using fresh-frozen femoral head allograft without an orthobiological agent was cost-effective and may have outcomes comparable to those using autograft or allograft enriched with orthobiological agents.


Assuntos
Artrodese/métodos , Calcâneo/lesões , Cabeça do Fêmur/transplante , Fraturas Ósseas/cirurgia , Fraturas Intra-Articulares/cirurgia , Articulação Talocalcânea/cirurgia , Articulação do Tornozelo/fisiopatologia , Transplante Ósseo , Humanos , Processamento de Imagem Assistida por Computador , Medição da Dor , Satisfação do Paciente , Estudos Retrospectivos , Transplante Autólogo , Transplante Homólogo
15.
Materials (Basel) ; 16(15)2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37570022

RESUMO

The application of surface coatings is a popular technique to improve the performance of materials used for medical and dental implants. Ternary silicon carbon nitride (SiCN), obtained by introducing nitrogen into SiC, has attracted significant interest due to its potential advantages. This study investigated the properties of SiCN films deposited via PECVD for dental implant coatings. Chemical composition, optical, and tribological properties were analyzed by adjusting the gas flow rates of NH3, CH4, and SiH4. The results indicated that an increase in the NH3 flow rate led to higher deposition rates, scaling from 5.7 nm/min at an NH3 flow rate of 2 sccm to 7 nm/min at an NH3 flow rate of 8 sccm. Concurrently, the formation of N-Si bonds was observed. The films with a higher nitrogen content exhibited lower refractive indices, diminishing from 2.5 to 2.3 as the NH3 flow rate increased from 2 sccm to 8 sccm. The contact angle of SiCN films had minimal differences, while the corrosion rate was dependent on the pH of the environment. These findings contribute to a better understanding of the properties and potential applications of SiCN films for use in dental implants.

16.
Foot Ankle Int ; 44(5): 431-442, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36946569

RESUMO

BACKGROUND: Currently, the standard of treatment for trimalleolar (TM) fracture is osteosynthesis through open reduction and internal fixation (ORIF). This study assessed whether arthroscopically assisted reduction and minimally invasive surgery (AARMIS) can be an alternative surgical method for TM fractures. METHODS: This retrospective cohort study included 49 patients with TM that were surgically treated. 27 patients received ORIF and 22 patients underwent AARMIS . At baseline, we recorded the patient's demographic features, fracture pattern (AO-OTA and Haraguchi classification), and surgical method. For postoperative results, we examined the patient's radiographic outcome, including time to union, quality of fracture reduction, as well as functional outcomes (American Orthopaedic Foot & Ankle Society ankle hindfoot score, ankle range of motion, and visual analog scale of pain) and perioperative complications. RESULTS: At mean follow-up of 46.6±24.6 (ORIF) and 36.4±18.5 months (AARMIS), both groups had comparable radiographic outcomes. No significant difference in rates of early ankle OA were detected. In terms of functional outcome, VAS pain and AOFAS score at postoperative day 3, postoperative month 3, and at final follow-up were not different. In terms of range of motion, we did not find a significant difference in mean range of motion. CONCLUSION: Patients with TM fractures treated with AARMIS achieved satisfactory results and was not significantly different in radiographic and functional performance compared with ORIF. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Fraturas do Tornozelo , Humanos , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Dor/etiologia
17.
Micromachines (Basel) ; 15(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38258140

RESUMO

Blood testing is a crucial application in the field of clinical studies for disease diagnosis and screening, biomarker discovery, organ function assessment, and the personalization of medication. Therefore, it is of the utmost importance to collect precise data in a short time. In this study, we utilized Raman spectroscopy to analyze blood samples for the extraction of comprehensive biological information, including the primary components and compositions present in the blood. Short-wavelength (532 nm green light) Raman scattering spectroscopy was applied for the analysis of the blood samples, plasma, and serum for detection of the biological characteristics in each sample type. Our results indicated that the whole blood had a high hemoglobin content, which suggests that hemoglobin is a major component of blood. The characteristic Raman peaks of hemoglobin were observed at 690, 989, 1015, 1182, 1233, 1315, and 1562-1649 cm-1. Analysis of the plasma and serum samples indicated the presence of ß-carotene, which exhibited characteristic peaks at 1013, 1172, and 1526 cm-1. This novel 3D silicon micro-channel device technology holds immense potential in the field of medical blood testing. It can serve as the basis for the detection of various diseases and biomarkers, providing real-time data to help medical professionals and patients better understand their health conditions. Changes in biological data collected in this manner could potentially be used for clinical diagnosis.

18.
Artigo em Inglês | MEDLINE | ID: mdl-36531804

RESUMO

Oral squamous cell carcinoma (OSCC) is one of the most common lip and oral cavity cancer types. It requires early detection via various medical technologies to improve the survival rate. While most detection techniques for OSCC require testing in a centralized lab to confirm cancer type, a point of care detection technique is preferred for on-site use and quick result readout. The modular biological sensor utilizing transistor-based technology has been leveraged for testing CIP2A, and optimal transistor gate voltage and load resistance for sensing setup was investigated. Sensitivities of 1 × 10-15 g/ml have been obtained for both detections of pure CIP2A protein and HeLa cell lysate using identical test conditions via serial dilution. The superior time-saving and high accuracy testing provides opportunities for rapid clinical diagnosis in the medical space.

19.
Materials (Basel) ; 16(17)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37687444

RESUMO

Peri-implantitis is a major cause of dental implant failure. This disease is an inflammation of the tissues surrounding the implant, and, while the cause is multi-factorial, bacteria is the main culprit in initiating an inflammatory reaction. Dental implants with silicon carbonitride (SiCN) coatings have several potential advantages over traditional titanium implants, but their antibacterial efficiency has not yet been evaluated. The purpose of this study was to determine the anti-bacterial potential of SiCN by modifying the surface of SiCN-coated implants to have a positive charge on the nitrogen atoms through the quaternization of the surface atoms. The changes in surface chemistry were confirmed using contact angle measurement and XPS analysis. The modified SiCN surfaces were inoculated with Streptococcus mutans (S. mutans) and compared with a silicon control. The cultured bacterial colonies for the experimental group were 80% less than the control silicon surface. Fluorescent microscopy with live bacteria staining demonstrated significantly reduced bacterial coverage after 3 and 7 days of incubation. Scanning electron microscopy (SEM) was used to visualize the coated surfaces after bacterial inoculation, and the mechanism for the antibacterial properties of the quaternized SiCN was confirmed by observing ruptured bacteria membrane along the surface.

20.
J Cell Biochem ; 113(5): 1733-43, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22213051

RESUMO

Silibinin, an effective chemo-preventive agent in various cancer types, suppresses cancer cell growth, but its effects on cancer stem-like cells (CSLCs) remain unclear. This study aimed to examine whether silibinin inhibited the development of CSLCs and disclose the underlying signaling. The colorectal cancer spheroid culture system was used for enriching CSLCs. The effects of silibinin on CSLCs were evaluated by counting sphere numbers, and calculating the percentage of CD133+ cells by flow cytometry and immunofluorescence both in the absence and presence of different concentrations of silibinin. The results showed the sphere number of CCS was 36 ± 9.6 after 15 days of CSLC enrichment in spheroid culture, and the percentage of CD133+ cells increased to 18 ± 6.4% compared to 3 ± 0.8% before enrichment. Treatment with silibinin reduced the sphere formation to 5 ± 3.3 and decreased the CD133+ percentage to 8 ± 2.3%. Interestingly, treatment of silibinin suppressed the activation of the AKT Ser473/mTOR pathway in spheroid culture through suppressing the activity of protein phosphatase 2Ac subunit (PP2Ac). In a xenograft tumor model, treatment with silibinin also inhibited tumor formation rate and tumor growth. Silibinin, which inhibits colon CSLCs self-renewal and sphere formation by suppressing the PP2Ac/AKT Ser473/mTOR pathway, may be a compound for developing new strategies in modulating CSLCs in cancer therapy.


Assuntos
Antineoplásicos/farmacologia , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Células-Tronco Neoplásicas/efeitos dos fármacos , Células-Tronco Neoplásicas/patologia , Silimarina/farmacologia , Antígeno AC133 , Animais , Antígenos CD/metabolismo , Apoptose/efeitos dos fármacos , Neoplasias Colorretais/metabolismo , Glicoproteínas/metabolismo , Células HT29 , Humanos , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Células-Tronco Neoplásicas/metabolismo , Peptídeos/metabolismo , Proteína Fosfatase 2/metabolismo , Proteínas Proto-Oncogênicas c-akt/metabolismo , Transdução de Sinais/efeitos dos fármacos , Silibina , Esferoides Celulares/efeitos dos fármacos , Esferoides Celulares/metabolismo , Esferoides Celulares/patologia , Serina-Treonina Quinases TOR/metabolismo , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA