Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 16(4): 435, 2016 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-27023556

RESUMO

In recent years, there has been an increase in the number of mobile robots controlled by a smart phone or tablet. This paper proposes a visual control interface for a mobile robot with a single camera to easily control the robot actions and estimate the 3D position of a target. In this proposal, the mobile robot employed an Arduino Yun as the core processor and was remote-controlled by a tablet with an Android operating system. In addition, the robot was fitted with a three-axis robotic arm for grasping. Both the real-time control signal and video transmission are transmitted via Wi-Fi. We show that with a properly calibrated camera and the proposed prototype procedures, the users can click on a desired position or object on the touchscreen and estimate its 3D coordinates in the real world by simple analytic geometry instead of a complicated algorithm. The results of the measurement verification demonstrates that this approach has great potential for mobile robots.

2.
Sensors (Basel) ; 15(3): 6174-95, 2015 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-25781508

RESUMO

Magnetic suspension systems are mechatronic systems and crucial in several engineering applications, such as the levitation of high-speed trains, frictionless bearings, and wind tunnels. Magnetic suspension systems are nonlinear and unstable systems; therefore, they are suitable educational benchmarks for testing various modeling and control methods. This paper presents the digital modeling and control of magnetic suspension systems. First, the magnetic suspension system is stabilized using a digital proportional-derivative controller. Subsequently, the digital model is identified using recursive algorithms. Finally, a digital mixed linear quadratic regulator (LQR)/H∞ control is adopted to stabilize the magnetic suspension system robustly. Simulation examples and a real-world example are provided to demonstrate the practicality of the study results. In this study, a digital magnetic suspension system model was developed and reviewed. In addition, equivalent state and output feedback controls for magnetic suspension systems were developed. Using this method, the controller design for magnetic suspension systems was simplified, which is the novel contribution of this study. In addition, this paper proposes a complete digital controller design procedure for magnetic suspension systems.

3.
Sensors (Basel) ; 15(12): 31781-93, 2015 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-26694404

RESUMO

The purpose of this paper is to propose a GSA-tuning IPD control technique for magnetic suspension systems. An educational demonstration on a magnetic-field sensed magnetic suspension system is examined for effectiveness. For the magnetic-field sensed magnetic suspension system (FSMSS), the current transducer is employed for measuring the electromagnetic coil current, and a Hall effect device is used for detecting the position of the suspended object. To achieve optimal performance, the gravitational search algorithm (GSA) is adopted for tuning the integral-proportional-derivative (IPD) controller. The IPD control includes the specified PD controller and an integrator. The specified PD control is employed for stabilizing the inherently unstable FSMSS, whereas the integral control is utilized for eliminating the steady-state error. The GSA can tune the IPD control parameters to enable optimal FSMSS performance. We achieved excellent results from the simulations and hands-on experiments for the proposed control strategies and structures.

4.
Sensors (Basel) ; 15(8): 18934-49, 2015 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-26247947

RESUMO

This paper proposes a resonant electric cradle design with infant cries recognition, employing an Arduino UNO as the core processor. For most commercially available electric cradles, the drive motor is closely combined with the bearing on the top, resulting in a lot of energy consumption. In this proposal, a ball bearing design was adopted and the driving force is under the cradle to increase the distance from the object to fulcrum and torque. The sensors are designed to detect the oscillation state, and then the force is driven at the critical time to achieve the maximum output response while saving energy according to the principle of resonance. As for the driving forces, the winding power and motors are carefully placed under the cradle. The sensors, including the three-axis accelerometer and infrared sensor, are tested and applied under swinging amplitude control. In addition, infant cry recognition technology was incorporated in the design to further develop its functionality, which is a rare feature in this kind of hardware. The proposed nonlinear operator of fundamental frequency (f0) analysis is able to identify different types of infant cries. In conclusion, this paper proposes an energy-saving electric cradle with infant cries recognition and the experimental results demonstrate the effectiveness of this approach.


Assuntos
Choro , Microcomputadores , Reconhecimento Automatizado de Padrão/métodos , Amplificadores Eletrônicos , Humanos , Lactente , Som , Análise de Ondaletas , Vento
5.
ScientificWorldJournal ; 2014: 587238, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24790573

RESUMO

This paper presents the design and evaluation of the hardware circuit for electronic stethoscopes with heart sound cancellation capabilities using field programmable gate arrays (FPGAs). The adaptive line enhancer (ALE) was adopted as the filtering methodology to reduce heart sound attributes from the breath sounds obtained via the electronic stethoscope pickup. FPGAs were utilized to implement the ALE functions in hardware to achieve near real-time breath sound processing. We believe that such an implementation is unprecedented and crucial toward a truly useful, standalone medical device in outpatient clinic settings. The implementation evaluation with one Altera cyclone II-EP2C70F89 shows that the proposed ALE used 45% resources of the chip. Experiments with the proposed prototype were made using DE2-70 emulation board with recorded body signals obtained from online medical archives. Clear suppressions were observed in our experiments from both the frequency domain and time domain perspectives.


Assuntos
Desenho de Equipamento , Ruídos Cardíacos , Estetoscópios/normas , Algoritmos , Humanos
6.
Micromachines (Basel) ; 7(9)2016 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-30404342

RESUMO

Due to the rapid development of science and technology in recent times, many effective controllers are designed and applied successfully to complicated systems. The significant task of controller design is to determine optimized control gains in a short period of time. With this purpose in mind, a combination of the particle swarm optimization (PSO)-based algorithm and the evolutionary programming (EP) algorithm is introduced in this article. The benefit of this integration algorithm is the creation of new best-parameters for control design schemes. The proposed controller designs are then demonstrated to have the best performance for nonlinear micro air vehicle models.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA