Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 10(6): 560-565, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28963365

RESUMO

BACKGROUND: Stent assisted coil embolization (SACE) of bifurcation aneurysms is challenging. Heterogeneous results have been achieved to date, but largely for laser cut stents. While braided stents offer multiple technical advantages, their long term efficacy has yet to be validated. OBJECTIVE: To report the first long term 18 month results for the durability of bifurcation aneurysms treated with braided stents. MATERIALS AND METHODS: Over a 4 year period, 59 consecutive patients with 60 bifurcation aneurysms underwent elective braided SACE across three Australian neurovascular centers. 17 of these aneurysms underwent T- or Y-shaped stent constructs. All patients had immediate, 6 month and 18 month clinical and radiological follow-up. Radiological assessment was made on modified Raymond-Roy occlusion scores while clinical assessment was based on the modified Rankin Scale. Subgroup analysis of 17 aneurysms treated with multi-stent constructs was conducted. RESULTS: 6 month follow-up data were available for 59 aneurysms and 18 month follow-up data for 58 aneurysms. Satisfactory aneurysm occlusion was achieved in 97% at inception and at 6 months, and 98% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Similar satisfactory results were achieved with the multi-stent construct cohort. Intraprocedural thromboembolic events were recorded in 5% and delayed events in 2%. Technical complications were found in 5%. All complication rate was 13%. CONCLUSION: Braided SACE was safe, efficacious, and durable at the long term 18 month follow-up, including for multi-stent constructs. Preliminary results indicate favorable clinical and radiological outcomes compared with laser cut stents.


Assuntos
Prótese Vascular , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents , Adulto , Idoso , Austrália/epidemiologia , Prótese Vascular/estatística & dados numéricos , Angiografia Cerebral/métodos , Procedimentos Endovasculares/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Stents/estatística & dados numéricos , Fatores de Tempo , Resultado do Tratamento
2.
J Neurointerv Surg ; 10(7): 669-674, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29246908

RESUMO

BACKGROUND: Preliminary short-term results for stent-assisted coil embolization (SACE) using woven/braided stents have been promising. However, evidence supporting mid- to long-term efficacy and durability is lacking. OBJECTIVE: To report the long-term results for the durability of elective intracranial aneurysms treated with woven stents. MATERIALS AND METHODS: Between May 2012 and May 2015, 98 consecutive patients with 103 aneurysms underwent elective woven SACE across three Australian neurovascular centres. All patients had immediate, 6- and 18-month clinical and radiological follow-up. Radiological assessment was performed with modified Raymond-Roy occlusion scores based on angiography results, while clinical assessment was based on the modified Rankin Scale. RESULTS: Six-month follow-up was available in 100 aneurysms, and an 18-month follow-up in 97 aneurysms. Total occlusion rates of 82% were achieved at inception, 82% at 6 months, and 90% at 18 months. Satisfactory occlusion with small neck remnants was present in 17% at inception, 16% at 6 months, and 9% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Intraprocedural thromboembolic events were recorded in 3% and delayed events in 1% (all in patients taking clopidogrel). Aneurysm recurrence occurred in one patient (1%). Technical complications occurred in 5%. The total complication rate was 10%. CONCLUSIONS: Woven SACE is safe, efficacious, and durable at long-term 18-month follow-up, with very low recurrence and re-treatment rates. Preliminary results appear better than those for traditional laser-cut stents.


Assuntos
Procedimentos Cirúrgicos Eletivos/tendências , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents Metálicos Autoexpansíveis/tendências , Adulto , Idoso , Austrália/epidemiologia , Prótese Vascular/tendências , Procedimentos Cirúrgicos Eletivos/instrumentação , Procedimentos Cirúrgicos Eletivos/métodos , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tromboembolia/diagnóstico por imagem , Tromboembolia/epidemiologia , Tromboembolia/cirurgia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA