Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Amino Acids ; 55(10): 1279-1284, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35701570

RESUMO

This paper describes the development of a voltammetric assay of insulin using a DNA immobilized onto a carbon nanotube paste electrode (CNPE), the peak potential of which was 0.2 V, vs. Ag/AgCl on the CNPE. The cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry parameters of the optimized conditions were determined. Low analytical working ranges of 10-80 ugL-1 CV and 0.01-0.1 ngL-1 SW were attained. The precision of the insulin concentration of 0.01 ugL-1 was 0.14 (n = 15) RSD using the optimum conditions, in which the detection limit was 0.004 ngL-1 (6.9 × 10-12 M) (S/N = 3) using only an accumulation time of 400 s. The developed method was applied to determine insulin in a pharmacy drug from analytical-grade chemicals (from Aldrich).


Assuntos
Nanotubos de Carbono , Farmácia , Insulina , Eletrodos
2.
Molecules ; 27(6)2022 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-35335199

RESUMO

Staphylococcus aureus bacteria is a ubiquitous Gram-positive microorganism that causes infections related to the sudden infant death syndrome. Recently, basic detection methods depend on complicated PCR amplification, electric separation, spectric adsorption and other detection systems. However, in this study, simplified sensitive voltammetric skills are developed. To identify an effective diagnostic method for Staphylococcus aureus (SA), a voltammetric sensing probe was sought using mercury immobilized on a carbon nanotube sensor (MCN). The voltammetric MCN conditions were optimized through stripping and cyclic voltammetry. Diagnostic electrolyte was used on non-treated blood sera as an electrolyte solution. The optimum cyclic and stripping analytical working range was 0.5-4.0 mL (3 × 102~5 × 102 CFU/0.5 mL) SA. The statistic relative standard deviation of 0.1 mL SA was observed to be 0.0078 (n = 5). Using the optimum parameters, a diagnostic test was performed by the direct assay of SA in non-treated human blood and patient sera. Here, the developed results can be used for the direct assay of non-treated blood sera, organ monitoring, in-vivo diagnosis, and other assays requiring SA detection.


Assuntos
Técnicas Biossensoriais , Mercúrio , Nanotubos de Carbono , Infecções Estafilocócicas , Técnicas Biossensoriais/métodos , Humanos , Staphylococcus aureus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA