Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1231-1243, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37930443

RESUMO

PURPOSE: To evaluate the baseline intraocular pressure (IOP)-related risk of severe steroid-induced ocular hypertension (SIOH). We hypothesized that the incidence and severity of SIOH may differ according to baseline IOP in patients who received intravitreal dexamethasone implants. METHODS: A total of 889 eyes treated with intravitreal dexamethasone implants and a baseline IOP of ≤ 23 mmHg were enrolled. Enrolled patients were divided into two groups: the steroid-responders (127 eyes) and the non-steroid-responders (762 eyes). The steroid-responders group was subdivided into post-injection IOP of ≥ 25, > 30, or > 35 mmHg or IOP elevation of ≥ 10 mmHg over the baseline value. The odds ratio of SIOH was calculated using univariable logistic regression analysis, and significant variables were analyzed with a multivariable model. IOP was measured before (baseline IOP) and after dexamethasone implant injection at 1 week and 1, 2, 3, 6, and 12 months. RESULTS: Although baseline IOP was significantly associated with the development of SIOH in logistic regression analysis, the results from the subgroup analysis differed. In the group with IOP elevation of ≥ 10 mmHg over the baseline, SIOH was not significantly associated with baseline IOP, but it was significantly related to higher baseline IOP in the severe SIOH group (IOP > 30 and > 35 mmHg). CONCLUSIONS: Higher baseline IOP is a risk factor for severe SIOH. Clinicians should be aware of the risk of SIOH when administering steroids intravitreally to patients with high baseline IOP (IOP > 19 mmHg).


Assuntos
Glaucoma , Edema Macular , Hipertensão Ocular , Humanos , Pressão Intraocular , Dexametasona , Edema Macular/etiologia , Hipertensão Ocular/induzido quimicamente , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/tratamento farmacológico , Glaucoma/complicações , Fatores de Risco , Injeções Intravítreas , Glucocorticoides , Estudos Retrospectivos
2.
Sci Rep ; 13(1): 9143, 2023 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-37277443

RESUMO

It is important to identify at-risk patients prior to administering steroid injections to prevent avoidable irreversible blindness inducted by steroid-induced ocular hypertension (SIOH). We aimed to investigate the association of SIOH following intravitreal dexamethasone implantation (OZURDEX) using anterior segment optical coherence tomography (AS-OCT). We conducted a retrospective case control study to assess the association between trabecular meshwork and SIOH. A total of 102 eyes that underwent both AS-OCT and intravitreal dexamethasone implant injection were divided into the post-steroid ocular hypertension and normal intraocular pressure groups. Ocular parameters that can contribute to intraocular pressure were measured using AS-OCT. Univariable logistic regression analysis was used to calculate the odds ratio of the SIOH and significant variables were further analyzed using a multivariable model. Trabecular meshwork (TM) height was significantly shorter in the ocular hypertension group (716.13 ± 80.55 µm) than that in the normal intraocular pressure group (784.27 ± 82.33 µm) (p < 0.001). The receiver operating characteristic curve technique analysis showed that the optimal cut-off of ≥ 802.13 µm for TM height specificity was 96.2%, and TM height with < 646.75 µm had a sensitivity of 94.70%. The odds ratio of the association was 0.990 (p = 0.001). TM height was identified as a newly observed association with SIOH. TM height can be assessed using AS-OCT, with acceptable sensitivity and specificity. Caution must be exercised while injecting steroids in patients with short TM height (especially < 646.75 µm) as it may cause SIOH and irreversible blindness.


Assuntos
Glaucoma , Hipertensão Ocular , Humanos , Malha Trabecular , Estudos Retrospectivos , Estudos de Casos e Controles , Hipertensão Ocular/induzido quimicamente , Pressão Intraocular , Dexametasona/efeitos adversos , Cegueira
3.
J Clin Med ; 11(17)2022 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-36078987

RESUMO

The most significant factor for endothelial cell loss should be readily identified, since prevention is the most crucial treatment. Here, we investigate risk factors for corneal endothelial cell density (ECD) decline following Ahmed glaucoma valve (AGV) implantation and determine the optimal cut-off values. This study included 103 eyes (95 patients) with glaucoma that underwent AGV implantation between January 2006 and January 2021 at a single medical center (Severance Hospital). We conducted consecutive t-tests between two groups separated by the ECD change rate to determine the survival state of the enrolled patients. Associations were evaluated using univariable and multivariable linear regressions. Optimal cut-off values for identified risk factors were analyzed using a Cox proportional hazards model and a receiver operating characteristic (ROC) curve based on logistic regression. Mean follow-up duration was 4.09 ± 2.20 years. After implementing consecutive t-tests, only patients with an ECD change rate greater than -6.1%/year were considered to have survived. Tube-iris distance (TID) was the only statistically significant factor identified in both the univariable and multivariable linear regressions. The cut-off value determined from the consecutive Cox regression method was 0.33 mm (smallest p-value of 0.0087), and the cut-off value determined from the ROC method was 0.371 mm (area under the receiver operating characteristic curve [AUC], 0.662). Patients with short TIDs showed a better ECD prognosis following AGV surgery; we suggest optimal TID cut-off values of 0.33 mm and 0.371 mm based on the implemented Cox regression and ROC methodology, respectively.

4.
NPJ Breast Cancer ; 7(1): 13, 2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33579950

RESUMO

Although Ki67 labeling index is a potential predictive marker for chemotherapy benefit, its clinical utility has been limited by the lack of a standard scoring method resulting in poor interobserver reproducibility. Especially, there is no consensus on the use of average versus hotspot score for reporting. In order to determine the best method for Ki67 scoring and validate manual scoring method proposed by the International Ki67 Working Group (IKWG), we systematically compared average versus hotspot score in 240 cases with a public domain image analysis program QuPath. We used OncotypeDx Recurrence Score (RS) as a benchmark to compare the potential clinical utility of each scoring methods. Both average and hotspot scores showed statistically significant but only modest correlation with OncotypeDx RS. Only hotspot score could meaningfully distinguish RS low-risk versus high-risk patients. However, hotspot score was less reproducible limiting its clinical utility. In summary, our data demonstrate that utility of the Ki67 labeling index is influenced by the choice of scoring method.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA